Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 33
Filtrar
1.
Int J Prosthodont ; 34(4): 441­447, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-33651041

RESUMEN

PURPOSE: To assess the impact of different types of dental prostheses, including definitive and interim restorations, on oral health-related quality of life (OHRQoL) before and after prosthetic treatment. MATERIALS AND METHODS: A total of 151 patients received prosthetic treatment at one of two German departments of prosthetic dentistry. The patients' OHRQoL was assessed using the German version of the Oral Health Impact Profile (OHIP-G53) at baseline (T0) and at 1 week (T1) and 3 months (T2) after treatment. Patients were divided into 10 subgroups according to their pre- and posttreatment status. The effect of the type (no prosthesis; fixed prosthesis; removable prosthesis) and duration of wear (definitive; interim) of the restorations was evaluated. Results were analyzed using Kolmogorov-Smirnov, Kruskal-Wallis, and Mann-Whitney U tests with a significance level of P = .05. RESULTS: The highest OHRQoL was recorded for patients with fixed restorations, as indicated by the fact that their OHIP scores were lowest. A significant improvement in OHRQoL (P ≤ .034) was observed for patients who needed prostheses and were then treated with removable or fixed restorations. The OHIP score was affected by a change in restoration type. Rehabilitation with definitive prostheses had a significant effect on posttreatment OHRQoL (P ≤ .006). CONCLUSION: In general, prosthetic rehabilitation by use of fixed or removable prostheses resulted in an improvement in OHRQoL. The use of the same type of restoration before and after treatment had a positive effect on OHRQoL. If possible, a change of restoration type should be avoided. For patients who require permanent prostheses, the use of fixed and removable restorations is recommended. For oral rehabilitation, fixed restorations should be preferred in order to achieve best possible improvement of OHIP score.


Asunto(s)
Salud Bucal , Calidad de Vida , Prótesis Dental de Soporte Implantado , Humanos , Estudios Prospectivos , Encuestas y Cuestionarios
2.
Clin Oral Investig ; 25(4): 2191-2201, 2021 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-32852596

RESUMEN

OBJECTIVES: To analyze the oral health-related impact profile in patients treated with three different types of dental prosthesis in student courses. MATERIALS AND METHODS: This prospective bicenter clinical trial was conducted with 151 patients being treated with fixed (n = 70), removable (n = 61), or telescopic dental prostheses (n = 20) in clinical student courses of two German universities from October 2018 to October 2019. All patients completed three standardized German versions of the Oral Health Impact Profile (OHIP-G49/53) before prosthetic treatment (T0), at control after 1 week (T1), and after 3 months (T2), divided into five dimensions: (a) appearance, (b) oral function, (c) psychosocial impact, (d) linguistic limitations, and (e) orofacial pain. Data were analyzed with Kolmogorov-Smirnov, Wilcoxon signed-rank, Kruskal-Wallis, Mann-Whitney, and Cronbach's alpha tests. RESULTS: Within T0-T1 and T0-T2, greater improvements were determined for removable compared with fixed dental prostheses for the dimensions' oral function (p ≤ 0.014), linguistic limitations (p ≤ 0.016), and appearance (p ≤ 0.003). No significant differences were found between fixed and telescopic dental prostheses (p ≥ 0.104) or between removable (partial dental prosthesis with clasps and complete dental prosthesis) and telescopic dental prostheses (p ≥ 0.100). Within T1-T2, a significant improvement in orofacial pain could be determined (p = 0.007). CONCLUSIONS: Restorations presented an improvement in oral health-related quality of life. Removable dental prostheses showed better improvement than fixed ones in various dimensions. CLINICAL RELEVANCE: Knowledge about the influence of oral health-related quality of life on the three different types of prosthesis used in student courses can be of decisive help in dental consultations.


Asunto(s)
Prótesis Dental , Dentadura Parcial Removible , Prótesis Dental de Soporte Implantado , Humanos , Salud Bucal , Estudios Prospectivos , Calidad de Vida , Estudiantes
3.
J Oral Rehabil ; 45(9): 669-676, 2018 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-29855069

RESUMEN

This study was to compare the short-term therapeutic efficacy of device-supported sensorimotor training with that of standard splint therapy for patients with myofascial temporomandibular disorder (TMD) pain over a treatment period of 3 months. We tested the hypothesis that both types of intervention are equally effective for pain reduction. In addition, the electromyographic (EMG) activity of the temporal and masseter muscles was recorded under conditions of force-controlled submaximum and maximum biting in intercuspation. Of consecutive patients seeking treatment for non-odontogenic oro-facial pain, 45 patients with myofascial TMD pain (graded chronic pain status, GCPS, I and II) were randomly assigned to 2 treatment groups (sensorimotor training and conventional splint treatment). Patients were evaluated 4 times (initial examination, 2, 6 and 12 weeks later) by use of the Research Diagnostic Criteria for Temporomandibular Disorders (RDC/TMD). Electromyographic activity was recorded at the initial session and after 3 months. Ease-of-use of the treatment options was also evaluated. Significant (P < .0001) pain reduction (sensorimotor training 53%, splint therapy 40%) was achieved for both groups, with no significant differences (P > .05) between the groups. Force-controlled sub-maximum normalized electromyographic activity was significantly different between T0 and T3 for group A (sensorimotor training, P < .05) but was not significantly different for group B (splint, P > .05). For normalized maximum-biting EMG activity in intercuspation, however, a significant increase in EMG activity was observed for group A for the masseter and temporal muscles (P < .001) and for group B for the masseter muscle only (P < .001). Moreover, sensorimotor training was significantly (P < .05) less easy to use than the splint. The results of this study confirm the pain-reducing effect of sensorimotor training for patients with myofascial TMD pain (GCPS I and II). This innovative active treatment might be a promising option for TMD pain patients.


Asunto(s)
Electromiografía , Dolor Facial/fisiopatología , Músculos Masticadores/fisiopatología , Trastornos de la Articulación Temporomandibular/fisiopatología , Adulto , Análisis de Varianza , Fuerza de la Mordida , Dolor Facial/rehabilitación , Dolor Facial/terapia , Femenino , Humanos , Registro de la Relación Maxilomandibular , Masculino , Contracción Muscular , Ferulas Oclusales , Dimensión del Dolor , Trastornos de la Articulación Temporomandibular/rehabilitación , Trastornos de la Articulación Temporomandibular/terapia , Resultado del Tratamiento , Adulto Joven
4.
J Oral Rehabil ; 45(6): 467-475, 2018 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-29663492

RESUMEN

The selection of local anaesthetic in dental practice is essential to the patient's comfort and the success of the treatment. Many patients prefer anaesthesia even for short treatments. Articaine is a local anaesthetic commonly used for dental practice. The duration of the effect of articaine on the nerve fibres is not yet precisely reported. This study was aimed to evaluate the clinical efficacy of 4% articaine with and without epinephrine in treatment of occlusal caries. Thirty healthy patients were included in this randomised double-blind study. Each subject received 4% articaine with and without epinephrine (1:100 000). Maxillary infiltration was used for occlusal caries of the maxillary premolars on right and left sides. Quantitative sensory testing (QST) was performed in the innervation area of the infraorbital nerve, and pulp vitality test was performed on restoration-free canines. Duration of anaesthesia was longer when articaine with epinephrine was used. Articaine without epinephrine showed faster recovery of sensory blockade compared to articaine with epinephrine. The epinephrine-containing agent, when compared to the plain articaine solution, showed significantly stronger and longer anaesthetic efficacy on the soft tissue by all parameters of QST. Articaine with epinephrine caused a more reliable pulpal analgesia. A pain-free treatment of the soft tissue up to 15 minutes can be performed under the vasoconstrictor-free anaesthetic without causing long-lasting numbness. Epinephrine-containing articaine delivers a longer, more effective anaesthesia and is preferable for caries treatments and longer invasive treatments of the soft tissue.


Asunto(s)
Anestesia Dental , Anestésicos Locales/farmacología , Carticaína/farmacología , Pulpa Dental/efectos de los fármacos , Epinefrina/farmacología , Administración Bucal , Adulto , Anestésicos Locales/administración & dosificación , Carticaína/administración & dosificación , Método Doble Ciego , Epinefrina/administración & dosificación , Femenino , Humanos , Masculino , Dimensión del Dolor , Resultado del Tratamiento
5.
J Oral Rehabil ; 44(5): 375-384, 2017 May.
Artículo en Inglés | MEDLINE | ID: mdl-28258640

RESUMEN

Although knowledge of short-range kinetic interactions between antagonistic teeth during mastication is of essential importance for ensuring interference-free fixed dental reconstructions, little information is available. In this study, the forces on and displacements of the teeth during kinetic molar biting simulating the power stroke of a chewing cycle were investigated by use of a finite-element model that included all the essential components of the human masticatory system, including an elastic food bolus. We hypothesised that the model can approximate the loading characteristics of the dentition found in previous experimental studies. The simulation was a transient analysis, that is, it considered the dynamic behaviour of the jaw. In particular, the reaction forces on the teeth and joints arose from contact, rather than nodal forces or constraints. To compute displacements of the teeth, the periodontal ligament (PDL) was modelled by use of an Ogden material model calibrated on the basis of results obtained in previous experiments. During the initial holding phase of the power stroke, bite forces were aligned with the roots of the molars until substantial deformation of the bolus occurred. The forces tilted the molars in the bucco-lingual and mesio-distal directions, but as the intrusive force increased the teeth returned to their initial configuration. The Ogden material model used for the PDL enabled accurate prediction of the displacements observed in experimental tests. In conclusion, the comprehensive kinetic finite element model reproduced the kinematic and loading characteristics of previous experimental investigations.


Asunto(s)
Restauración Dental Permanente/métodos , Análisis de Elementos Finitos , Masticación/fisiología , Músculos Masticadores/anatomía & histología , Articulación Temporomandibular/anatomía & histología , Adulto , Vías Aferentes , Fenómenos Biomecánicos , Fuerza de la Mordida , Simulación por Computador , Restauración Dental Permanente/instrumentación , Dentición , Humanos , Imagenología Tridimensional , Cinética , Masculino , Modelos Anatómicos , Ajuste Oclusal , Ligamento Periodontal/anatomía & histología , Estrés Mecánico , Articulación Temporomandibular/fisiología
6.
J Oral Rehabil ; 43(8): 621-9, 2016 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-27198539

RESUMEN

The purpose of this study was to measure enamel wear caused by antagonistic monolithic zirconia crowns and to compare this with enamel wear caused by contralateral natural antagonists. Twenty monolithic zirconia full molar crowns were placed in 20 patients. Patients with high activity of the masseter muscle at night (bruxism) were excluded. For analysis of wear, vinylpolysiloxane impressions were prepared after crown incorporation and at 6-, 12-, and 24-month follow-up. Wear of the occlusal contact areas of the crowns, of their natural antagonists, and of two contralateral natural antagonists (control teeth) was measured by use of plaster replicas and a 3D laser-scanning device. Differences of wear between the zirconia crown antagonists and the control teeth were investigated by means of two-sided paired Student's t-tests and linear regression analysis. After 2 years, mean vertical loss was 46 µm for enamel opposed to zirconia, 19-26 µm for contralateral control teeth and 14 µm for zirconia crowns. Maximum vertical loss was 151 µm for enamel opposed to zirconia, 75-115 µm for control teeth and 60 µm for zirconia crowns. Statistical analysis revealed significant differences between wear of enamel by zirconia-opposed teeth and by control teeth. Gender, which significantly affected wear, was identified as a possible confounder. Monolithic zirconia crowns generated more wear of opposed enamel than did natural teeth. Because of the greater wear caused by other dental ceramics, the use of monolithic zirconia crowns may be justified.


Asunto(s)
Coronas/efectos adversos , Esmalte Dental/patología , Materiales Dentales/efectos adversos , Desgaste de los Dientes/patología , Circonio/efectos adversos , Adulto , Anciano , Femenino , Humanos , Masculino , Ensayo de Materiales , Persona de Mediana Edad , Propiedades de Superficie , Adulto Joven
7.
Dent Mater ; 31(12): 1552-60, 2015 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-26547870

RESUMEN

OBJECTIVES: The purpose of this study was to assess the effect of surface treatment on the fracture resistance of zirconia-based all-ceramic anterior crowns. METHODS: Sixty-four zirconia-based all-ceramic anterior crowns, veneered by use of a press-on technique, were produced. For 48 crowns intraoral adjustment was simulated (A-group), 16 crowns remained unadjusted (WA-group). The adjusted area was then treated in three ways: 1. no further surface treatment; 2. polishing, with irrigation, using polishers interspersed with diamond grit for ceramics; and 3. polishing and glaze firing. Half of the specimens were loaded until fracture in an universal testing device without artificial ageing; the other crowns underwent thermocycling and chewing simulation before ultimate-load testing. Explorative statistical analysis was performed by use of non-parametric and parametric tests. In addition, fracture-strength tests according to ISO 6872 were performed for veneer ceramic subjected to the different surface treatments. Finite element analysis was also conducted for the crowns, and surface roughness was measured. RESULTS: Crowns in the A-group were more sensitive to aging than crowns in the WA-group (p=0.038). Although both polishing and glaze firing slightly improved the fracture resistance of the specimens, the fracture resistance in the WA-group (initial fracture resistance (IFR): 652.0 ± 107.7N, remaining fracture resistance after aging (RFR): 560.6 ± 233.3N) was higher than the fracture resistance in the A-group (polished: IFR: 477.9 ± 108.8N, RFR: 386.0 ± 218.5N; glaze firing: IFR: 535.5 ± 128.0N, RFR: 388.6 ± 202.2N). Surface roughness without adjustment was Ra=0.1 µm; for adjustment but without further treatment it was Ra=1.4 µm; for adjustment and polishing it was Ra=0.3 µm; and for adjustment, polishing, and glazing it was Ra=0.6 µm. Stress distributions obtained by finite element analysis in combination with fracture strength tests showed that fractures most probably originated from the occlusal surface. SIGNIFICANCE: To improve fracture resistance and reduce the incidence of failure, extensive occlusal adjustment of veneered anterior zirconia restorations should be avoided. Neither polishing nor glazing could restore the fracture resistance to the level maintained with unadjusted crowns.


Asunto(s)
Coronas , Diseño de Prótesis Dental , Fracaso de la Restauración Dental , Circonio/química , Análisis del Estrés Dental , Análisis de Elementos Finitos , Ensayo de Materiales , Propiedades de Superficie
8.
J Oral Rehabil ; 41(12): 920-7, 2014 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-25155353

RESUMEN

To evaluate the in vitro fracture load of extensively damaged vital teeth after either direct or indirect restauration, severe tooth substance loss was simulated for 96 molars. Subsequently, two cavities were prepared with little (design 1) or more substantial (design 2) residual tooth support. All molars were provided with a 2-mm ferrule design and then divided into 12 test groups based on their occlusal surface size. They were restored with composite or with either of two types of single crown (cast metal or milled zirconia). After thermal ageing (10,000 cycles at 6.5 and 60 °C), 1.2 million cycles of chewing simulation were applied (64 N). Maximum fracture load was determined with a loading angle of 45°. Statistical analysis was performed by use of Kaplan-Meier modelling, Student's t-tests, one-way anova, post hoc Tukey's HSD tests and linear regression analysis. Regarding mean fracture load without ageing, the indirect restorations outperformed composite (design 1: direct: 508 ± 123 N, indirect: 741 ± 248 N; design 2: direct: 554 ± 167 N, indirect: 903 ± 221 N). After artificial ageing, however, these differences were no longer significant (design 1: direct: 328 ± 189 N, indirect: 506 ± 352 N; design 2: direct 399 ± 208 N, indirect 577 ± 292 N). Instead, the fracture load of the aged composite restorations was comparable with that for zirconia (design 1) and cast metal (design 2) crowns. Fracture loads of direct composite restorations after artificial ageing might fulfil clinical requirements.


Asunto(s)
Restauración Dental Permanente/métodos , Fracturas de los Dientes/prevención & control , Diente no Vital/fisiopatología , Coronas , Fracaso de la Restauración Dental , Análisis del Estrés Dental , Cementos de Ionómero Vítreo , Humanos , Técnicas In Vitro , Ensayo de Materiales , Diente Molar , Circonio
9.
J Oral Rehabil ; 41(4): 314-22, 2014 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-24447258

RESUMEN

The purpose of this study was to evaluate enamel wear caused by monolithic zirconia crowns and to compare this with enamel wear caused by contralateral natural antagonists. Twenty monolithic zirconia crowns were placed in 20 patients requiring full molar crowns. For measurement of wear, impressions of both jaws were made at baseline after crown cementation and at 6-month follow-up. Mean and maximum wear of the occlusal contact areas of the crowns, of their natural antagonists and of the two contralateral natural antagonists were measured by the use of plaster replicas and 3D laser scanning methods. Wear differences were investigated by the use of two-sided paired Student's t-tests and by linear regression analysis. Mean vertical loss (maximum vertical loss in parentheses) was 10 (43) µm for the zirconia crowns, 33 (112) µm for the opposing enamel, 10 (58) µm for the contralateral teeth and 10 (46) µm for the contralateral antagonists. Both mean and maximum enamel wear were significantly different between the antagonists of the zirconia crowns and the contralateral antagonists. Gender and activity of the masseter muscle at night (bruxism) were identified as possible confounders which significantly affected wear. Under clinical conditions, monolithic zirconia crowns seem to be associated with more wear of opposed enamel than are natural teeth. With regard to wear behaviour, clinical application of monolithic zirconia crowns is justifiable because the amount of antagonistic enamel wear after 6 months is comparable with, or even lower than, that caused by other ceramic materials in previous studies.


Asunto(s)
Coronas/efectos adversos , Materiales Dentales/efectos adversos , Alisadura de la Restauración Dental , Desgaste de los Dientes , Circonio/efectos adversos , Adulto , Anciano , Esmalte Dental , Electromiografía , Femenino , Estudios de Seguimiento , Humanos , Masculino , Músculo Masetero/fisiología , Persona de Mediana Edad , Diente Molar , Resultado del Tratamiento , Adulto Joven
10.
Dent Mater ; 30(2): 122-30, 2014 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-24246472

RESUMEN

OBJECTIVES: This in vitro study should assess the fracture resistance of veneered zirconia-based crowns with either luted or fused veneer. METHODS: Thirty-two identical zirconia frameworks (IPS e.max ZirCAD; Ivoclar/Vivadent), were constructed (inLab 3.80; Sirona Dental Systems). All frameworks were veneered with CAD/CAM-fabricated lithium disilicate ceramic (IPS e.max CAD; Ivoclar/Vivadent). For half the crowns (n=16) the veneer was luted to the framework (Multilink Implant; Ivoclar/Vivadent); for the other it was fused (IPS e.max Crystall./Connect; Ivoclar/Vivadent). Half of the specimens were then loaded until failure without artificial aging; the other half underwent artificial aging before assessment of the ultimate load. To compare the two techniques further, finite element analysis (FEA) and fractographic assessment using SEM and EDX analysis were conducted. Statistical assessment was performed by use of non-parametric tests. RESULTS: Initial fracture forces were higher in the fusion group (mean: 1388±190 N versus 1211±158 N). All specimens were insensitive to artificial aging. FEA showed that tensile stresses in the veneer at the frame-veneer interface were much higher for crowns with luted veneer; this may be the reason for their lower fracture resistance. Fractographic analysis revealed that both fused and luted specimens had cohesive and adhesive fracture patterns which resulted in partial delamination of the veneer. SIGNIFICANCE: Fused crowns are superior to luted crowns. Comparison of fracture resistance with the maximum loads which may occur clinically (Fmax=600 N on one tooth) suggests both techniques might be used clinically, however.


Asunto(s)
Cerámica , Porcelana Dental/química , Coronas con Frente Estético , Fracturas de los Dientes/prevención & control , Circonio/química , Humanos , Técnicas In Vitro
11.
Arch Oral Biol ; 58(12): 1751-60, 2013 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-24200301

RESUMEN

OBJECTIVE: The purpose of this study was to test the hypothesis that jaw clenching induces co-contraction and low-level long-lasting tonic activation (LLTA) of neck muscles in the supine position. DESIGN: Ten healthy subjects developed various feedback-controlled submaximum bite forces in different bite-force directions in supine position. The electromyographic (EMG) activity of the semispinalis capitis, semispinalis cervicis, multifidi, splenius capitis, levator scapulae, trapezius, sternocleidomastoideus, masseter and infra/supra-hyoidal muscles was recorded. For normalization of EMG data, maximum-effort tasks of the neck muscles were performed. RESULTS: Co-contractions of the posterior neck muscles varied between 2% and 11% of their maximum voluntary contraction. Different bite forces and bite-force directions resulted in significant (p<.05) activity differences between the co-contraction levels of the neck muscles. In addition, LLTA of specific neck muscles, provoked by the jaw clenching tasks, was observed. CONCLUSIONS: This study demonstrated for the first time moderate co-contractions of jaw and neck muscles in the supine position under controlled submaximum jaw clenching forces. LLTA of most neck muscles was observed, outlasting clenching episodes and indicating an additional neuromuscular interaction between the two muscle groups.


Asunto(s)
Fuerza de la Mordida , Bruxismo/fisiopatología , Maxilares/fisiología , Músculo Masetero/fisiología , Contracción Muscular/fisiología , Músculos del Cuello/fisiología , Electromiografía/métodos , Femenino , Humanos , Imagen por Resonancia Magnética , Masculino , Posición Supina , Adulto Joven
12.
J Oral Rehabil ; 40(7): 519-25, 2013 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-23663118

RESUMEN

The purpose of this in vitro study was to assess the breaking load of zirconia-based crowns veneered with either CAD/CAM-produced or manually layered feldspathic ceramic. Thirty-two identical zirconia frameworks (Sirona inCoris ZI, mono L F1), 0·6 mm thick with an anatomically shaped occlusal area, were constructed (Sirona inLab 3.80). Sixteen of the crowns were then veneered by the use of CAD/CAM-fabricated feldspathic ceramic (CEREC Bloc, Sirona) and 16 by the use of hand-layered ceramic. The CAD/CAM-manufactured veneer was attached to the frameworks by the use of Panavia 2.0 (Kuraray). Half of the specimens were loaded until failure without artificial ageing; the other half of the specimens underwent thermal cycling and cyclic loading (1·2 million chewing cycles, force magnitude F(max) = 108 N) before the assessment of the ultimate load. To investigate the new technique further, finite element (FE) computations were conducted on the basis of the original geometry. Statistical assessment was made by the use of non-parametric tests. Initial breaking load was significantly higher in the hand-layered group than in the CAD/CAM group (mean: 1165·86 N versus 395·45 N). During chewing simulation, however, 87·5% (7/8) of the crowns in the hand-layered group failed, whereas no crown in the CAD/CAM group failed. The CAD/CAM-produced veneer was significantly less sensitive to ageing than the hand-layered veneer.


Asunto(s)
Coronas/normas , Materiales Dentales/química , Diseño de Prótesis Dental/métodos , Fracaso de la Restauración Dental , Coronas con Frente Estético/normas , Envejecimiento , Cerámica/química , Diseño Asistido por Computadora , Análisis del Estrés Dental , Análisis de Elementos Finitos , Humanos , Masticación , Ensayo de Materiales , Estrés Mecánico , Circonio/química
13.
Dentomaxillofac Radiol ; 42(6): 20120199, 2013.
Artículo en Inglés | MEDLINE | ID: mdl-23503807

RESUMEN

OBJECTIVES: To assess the position of the temporomandibular joint (TMJ) disc in patients with TMJ pain and compare it with equivalent published data of asymptomatic volunteers. METHODS: The oblique coronal closed- and open-jaw MR images from 66 patients with TMJ pain were evaluated. Clinical examination followed the research diagnostic criteria for temporomandibular disorders. In all coronal images, the transverse condylar axis and the medial and lateral edges of the disc were determined using special software. Inter-rater agreement was calculated [two raters; inter-rater correlation coefficient (ICC)]. The presence of osteoarthrosis (OA) was determined by two independent raters. The influence of OA was estimated in patients (generalized estimation equation model). The results were compared with those of healthy volunteers (t-test). Differences between closed and open jaw in patients were analysed with the Wilcoxon matched-pair test. RESULTS: The ICC was good for the transverse condylar axis (0.987) and the medial edge of the disc (0.799) and fair for the lateral edge (0.355). On average, the disc projected 5.5% to the medial side; laterally, the condyle was partially uncovered by the disc (-16.6%). In the open-jaw position, both the medial and the lateral edges shifted medially (to 17.6% vs -23.6%, Wilcoxon matched-pair test, p < 0.001). OA had no significant influence (generalized estimation equation model, p = 0.952). The disc position differed significantly from asymptomatic individuals (t-test, p < 0.001) who showed a medial disc position and full coverage of the condyle. CONCLUSIONS: In patients with TMJ pain, the disc seems to be smaller and located less medially than in healthy volunteers. The extent of the medial shift on opening was similar.


Asunto(s)
Dolor Facial/diagnóstico , Imagen por Resonancia Magnética/métodos , Disco de la Articulación Temporomandibular/patología , Trastornos de la Articulación Temporomandibular/diagnóstico , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Procesamiento de Imagen Asistido por Computador/métodos , Imagen por Resonancia Magnética/estadística & datos numéricos , Masculino , Cóndilo Mandibular/patología , Persona de Mediana Edad , Variaciones Dependientes del Observador , Osteoartritis/diagnóstico , Rango del Movimiento Articular/fisiología , Estudios Retrospectivos , Adulto Joven
14.
Clin Oral Investig ; 17(5): 1287-94, 2013 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-23436119

RESUMEN

OBJECTIVES: To help the dental practitioner solve a specific clinical problem, systematic reviews (SRs) are seen as the best guide. In addition to the unmanageable quantity of SRs, however, one should be aware of their variable quality. The present review describes the methodological quality of SRs on postendodontic restorations to work out the value of these reviews for the dental practitioner. METHODOLOGY: SRs were searched in April 2012, independently and in triplicate. Post survival was used as measure of outcome. The methodological quality of included SRs was assessed with the Revised Assessment of Multiple Systematic Reviews (R-AMSTAR) checklist. Kappa statistics were used to assess reviewer agreement. RESULTS: Three hundred sixty-three papers were retrieved from the initial search. Ten SRs were included. One SR achieved a high R-AMSTAR score, whereas the other nine SRs achieved scores that indicate a substantial lack of methodological quality. Especially the items "grey literature," "combination of findings," "likelihood of publication bias," and conflict of interest" showed low R-AMSTAR scores. The three reviews with the highest R-AMSTAR scores tended to conclude that fewer failures occurred when using nonmetal posts. The reviewer agreement was excellent (kappa ranged from 0.79 to 0.85) in the R-AMSTAR classification. CONCLUSION: The approach presented revealed a lack of SRs with high methodological quality. Thus, no decisive conclusion can be drawn with respect to this topic. It appears that there is a trend for the superiority of fiber-reinforced posts. CLINICAL RELEVANCE: SRs must be of high methodological quality. This can be achieved by taking into consideration the results of this review. Improved methodological quality would make SRs more supportive for the general practitioner.


Asunto(s)
Técnica de Perno Muñón/instrumentación , Técnica de Perno Muñón/normas , Garantía de la Calidad de Atención de Salud/métodos , Proyectos de Investigación/normas , Literatura de Revisión como Asunto , Tratamiento del Conducto Radicular/normas , Adulto , Lista de Verificación , Retención de Prótesis Dentales , Fracaso de la Restauración Dental , Vidrio , Humanos , Metales , Variaciones Dependientes del Observador , Retratamiento , Tratamiento del Conducto Radicular/instrumentación , Tratamiento del Conducto Radicular/métodos
15.
Clin Oral Investig ; 17(1): 259-67, 2013 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-22302454

RESUMEN

OBJECTIVES: A key aspect of complex restorative therapy is reconstruction of a new three-dimensional jaw relation. The objective of this study was to test the hypotheses that the initially recorded jaw relation would deviate substantially from the jaw position of the prosthetic reconstruction and that activity ratios of the jaw muscles would be significantly different for each of these jaw positions. MATERIALS AND METHODS: In 41 healthy subjects, 41 examiners incorporated intraoral occlusal devices fabricated with all the technical details and procedures commonly used during prosthetic reconstructions. The jaw positions in centric relation with the incorporated occlusal devices were telemetrically measured in the condylar, first molar and incisal regions, relative to intercuspation. Electromyographic (EMG) activity of the temporalis and masseter muscles was recorded, and activity ratios were calculated for homonymous and heteronymous muscles. RESULTS: The recorded jaw relation differed significantly (p < 0.001) from the jaw position reconstructed with the intraoral occlusal devices. The initially recorded jaw relation was reproduced with the intraoral occlusal device with spatial accuracy of approximately 0.3 mm in the condylar, molar and incisal regions. The EMG ratios between centric relations and the reconstructed positions were significantly different (p < 0.05) for the temporal muscle and the temporalis/masseter ratio. CONCLUSIONS: The findings revealed that three-dimensional jaw-relation recording may be reproduced in a simulated prosthetic reconstruction within the accuracy reported for replicate intraoral bite recordings. CLINICAL RELEVANCE: Centric relation recordings may be reproduced in a prosthetic reconstruction with the spatial accuracy of 0.3 mm.


Asunto(s)
Diseño de Prótesis Dental , Registro de la Relación Maxilomandibular/métodos , Resinas Acrílicas/química , Relación Céntrica , Articuladores Dentales , Materiales de Impresión Dental/química , Oclusión Dental Céntrica , Electromiografía , Femenino , Humanos , Imagenología Tridimensional/métodos , Incisivo/anatomía & histología , Registro de la Relación Maxilomandibular/instrumentación , Masculino , Mandíbula/anatomía & histología , Cóndilo Mandibular/anatomía & histología , Músculo Masetero/fisiología , Metilmetacrilatos/química , Modelos Dentales , Diente Molar/anatomía & histología , Contracción Muscular/fisiología , Telemetría/instrumentación , Músculo Temporal/fisiología , Interfaz Usuario-Computador , Adulto Joven
16.
J Oral Rehabil ; 39(7): 552-7, 2012 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-22574689

RESUMEN

The purpose of this prospective cohort study was to assess the performance of tooth-supported, long-span, zirconia fixed dental prostheses (FDPs). Thirty FDPs with span lengths from 36 to 46 mm (mean 40·33 mm), with 4-7 units and with connector dimensions ∼9 mm(2) were inserted (19 in the posterior region, 11 including anterior teeth) using glass-ionomer cement. The performance of the FDPs was assessed (aesthetic evaluation, failures, hypersensitivity/tooth vitality, secondary caries, pocket depth, decementation, and chipping) at baseline and after 5 years. Cox regression analysis was performed to identify risk factors. There were 16 failures after 5 years. Framework fracture occurred for two FDPs, four FDPs had to be re-cemented, one abutment tooth had to be treated endodontically, one abutment tooth fractured and cohesive failure of the veneer occurred for eight. Four FDPs had to be replaced, so survival was 82%. The aesthetics were rated as excellent by the patients at baseline and good at the 5-year recall. Cox regression analysis showed that both length [P = 0·05, exp(B) = 1·22] and location [P = 0·019, exp(B) = 4·09] of the FDP were risk factors for failure. Compared with the previously published 2-year results, the incidence of complications increased dramatically. Additionally, it was shown that long-span FDPs in the molar region are at greater risk of failure than FDPs in the anterior region.


Asunto(s)
Materiales Dentales/normas , Diseño de Prótesis Dental/normas , Fracaso de la Restauración Dental/estadística & datos numéricos , Dentadura Parcial Fija/normas , Circonio/normas , Adulto , Cementación/métodos , Femenino , Estudios de Seguimiento , Cementos de Ionómero Vítreo , Humanos , Masculino , Persona de Mediana Edad , Satisfacción del Paciente , Estudios Prospectivos , Factores de Riesgo , Resultado del Tratamiento
17.
J Prosthet Dent ; 107(2): 71-4, 2012 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-22304739

RESUMEN

This clinical report describes the use of modern CAD/CAM technology combined with a conventional impression technique to treat a malformed tooth with ceramic veneer in a single appointment. A thin veneer (0.4 mm) made of lithium disilicate ceramic was used to correct the shape of the malformed tooth with a minimally invasive preparation using a chairside CAD/CAM system. Thus the treatment can be performed during one appointment. To facilitate the CAD/CAM process and fabrication of the veneer, a scanable model fabricated on a modified gypsum definitive cast was used. The malformed tooth was corrected on the cast by use of a composite resin and an impression was then made. This trimmed impression was used intraorally during the scanning process to facilitate fabrication of the veneer.


Asunto(s)
Diseño Asistido por Computadora , Porcelana Dental/química , Coronas con Frente Estético , Incisivo/anomalías , Grabado Ácido Dental , Adolescente , Sulfato de Calcio/química , Resinas Compuestas/química , Técnica de Impresión Dental , Materiales Dentales/química , Diseño de Prótesis Dental , Estética Dental , Técnicas de Retracción Gingival , Humanos , Masculino , Modelos Dentales , Cementos de Resina/química , Preparación del Diente/métodos
18.
J Oral Rehabil ; 39(5): 338-48, 2012 May.
Artículo en Inglés | MEDLINE | ID: mdl-22220913

RESUMEN

Aim of this study was to introduce a feasible and valid technique for the assessment of masticatory performance that is comparable to the standard sieving method. Twenty-one chewing samples (Optosil) comminuted by healthy dentate adults were analysed with a sieving and scanning method. Scanning was performed using a conventional flatbed scanner (1200dpi). All scanned images underwent image analysis (ImageJ), which yielded descriptive parameters such as area, best-fitting ellipse for each particle. Of the 2D-image, a volume was estimated for each particle, which was converted into a weight. To receive a discrete distribution of particle sizes comparable to sieving, five chewing samples were used to calculate a size-dependent area-volume-conversion factor. The sieving procedure was carried out with a stack of 10 sieves, and the retained particles per sieve were weighed. The cumulated weights yielded by either method were curve-fitted with the Rosin-Rammler distribution to determine the median particle size x(50) . The Rosin-Rammler distributions for sieving and scanning resemble each other. The distributions show a high correlation (0·919-1·0, n= 21, P<0·01, Pearson's correlation coefficient). The median particle sizes vary between 3·83 and 4·77mm (mean: 4·31) for scanning and 3·53 and 4·55mm (mean: 4·21) for sieving. On average, scanning overestimates the x(50) values by 2·4%. A modified Bland-Altman plot reveals that 95% of the x(50) values fall within 10% of the average x(50) . The scanning method is a valid, simple and feasible method to determine masticatory performance.


Asunto(s)
Masticación/fisiología , Tamaño de la Partícula , Adulto , Estudios de Factibilidad , Femenino , Humanos , Procesamiento de Imagen Asistido por Computador , Masculino , Óptica y Fotónica , Reproducibilidad de los Resultados , Siliconas , Adulto Joven
19.
J Dent ; 40(2): 154-62, 2012 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-22197634

RESUMEN

OBJECTIVES: The aim of this in vitro study was to assess the ultimate load to failure of zirconia based crowns veneered with CAD/CAM manufactured ceramic. METHODS: 32 identical, anatoform zirconia (Sirona inCoris ZI, mono L F1) frameworks (thickness 0.6mm) were constructed (Sirona inLab 3.80). Afterwards, 16 crowns were completed using a CAD/CAM manufactured lithium disilicate ceramic veneer (IPS e.max CAD, Ivoclar Vivadent). The remaining 16 frames were veneered using conventional manual layering technique. For the CAD/CAM manufactured veneers, the connection between framework and veneer was accomplished via a glass fusion ceramics. Before fracture tests, half of the specimens underwent thermocycling and chewing simulation (1.2 million chewing cycles, force magnitude F(max)=108 N). To further investigate the new technique, finite element computations were carried out on the basis of the original geometry. RESULTS: Nearly all (87.5%) conventionally veneered crowns failed already during chewing simulation, whereas crowns with CAD/CAM manufactured veneers were non-sensitive to artificial ageing. Crowns veneered with lithium disilicate ceramic displayed ultimate loads to failure of about 1600 N. CONCLUSION: The CAD/CAM production of veneers for restorations with zirconia framework is a promising way to reduce failures originating from material fatigue.


Asunto(s)
Diseño Asistido por Computadora , Coronas , Materiales Dentales/química , Porcelana Dental/química , Fracaso de la Restauración Dental , Coronas con Frente Estético , Circonio/química , Fenómenos Biomecánicos , Fuerza de la Mordida , Cerámica/química , Simulación por Computador , Módulo de Elasticidad , Análisis de Elementos Finitos , Humanos , Ensayo de Materiales , Estrés Mecánico , Propiedades de Superficie , Temperatura , Factores de Tiempo
20.
Eur J Dent Educ ; 15(3): 172-8, 2011 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-21762322

RESUMEN

INTRODUCTION: An objective structured clinical examination (OSCE) has been implemented in preclinical dentistry. It was taken at an early stage (propaedeutics course). The objectives of this study were to evaluate the reliability, validity, and feasibility of the examination, and the effect of circuit number on OSCE score. METHODS: The OSCE was designed by an expert committee on the basis of pre-reviewed blueprints and checklists. Eleven stations formed an interdisciplinary circuit. Six groups of students (n = 62) passed sequentially round the same circuit. Statistical analysis was performed by using SPSS. Reliability was determined by measurement of internal consistency (Cronbach's α, Guttman's λ(2) ), standard error of measurement (SEM) (comprising generalisability index α, dependability index ϕ and pass 150;fail reliability p(c) ), consistency coefficient κ, item 150;scale correlation (Pearson correlation), and, because the unidimensionality of the stations could not be assumed, factor analysis including varimax rotation. Convergent validity (Pearson correlation, t-test), and predictive validity for future preclinical courses and the final preclinical examination were assessed by analysis of variance (ANOVA). The effect of the circuit number on score improvement was calculated, including a correction for the general competence of the students (ANOVA). Cost was calculated on the basis of the time invested. RESULTS: Fifty-three out of sixty-two students passed the OSCE (mean score: 67%, SD 7.7, range, 47-81). Scores for each station correlated significantly with total scores (r = 0.35-0.54, P < 0.01). For internal consistency, α = 0.75 (relative SEM 3.8) and λ(2) = 0.766. The dependability index was ϕ = 0.694 (absolute SEM 4.4), p(c) = 0.89 and κ = 0.61. Factor analysis yielded two components: dental-materials-oriented stations and all other stations (explained variance 43%). Scores correlated significantly with success in passing practical tests (i.e. performing dental procedures under examination conditions) (known group validity, P < 0.01) and with scores for subsequent courses and the final preclinical examination (Physikum) (predictive validity, P < 0.001). Later groups performed 4% better on average (CI 95%: 1.2-6.8%; P < 0.01). The cost was 181 Euro per student. CONCLUSIONS: The OSCE is reliable and valid in the context of preclinical dentistry. The cost is substantial. The problem of improvement of students' results with ascending circuit number has to be addressed.


Asunto(s)
Educación en Odontología , Evaluación Educacional/métodos , Análisis de Varianza , Costos y Análisis de Costo , Curriculum , Evaluación Educacional/economía , Evaluación Educacional/normas , Estudios de Factibilidad , Humanos , Reproducibilidad de los Resultados , Estadísticas no Paramétricas
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA