1.
Eur Radiol ; 2024 Jan 10.
Artículo en Inglés | MEDLINE | ID: mdl-38195730

RESUMEN

OBJECTIVES: Assessment of myocardial strain by feature tracking magnetic resonance imaging (FT-MRI) in human fetuses with and without congenital heart disease (CHD) using cardiac Doppler ultrasound (DUS) gating. METHODS: A total of 43 human fetuses (gestational age 28-41 weeks) underwent dynamic cardiac MRI at 3 T. Cine balanced steady-state free-precession imaging was performed using fetal cardiac DUS gating. FT-MRI was analyzed using dedicated post-processing software. Endo- and epicardial contours were manually delineated from fetal cardiac 4-chamber views, followed by automated propagation to calculate global longitudinal strain (GLS) of the left (LV) and right ventricle (RV), LV radial strain, and LV strain rate. RESULTS: Strain assessment was successful in 38/43 fetuses (88%); 23 of them had postnatally confirmed diagnosis of CHD (e.g., coarctation, transposition of great arteries) and 15 were heart healthy. Five fetuses were excluded due to reduced image quality. In fetuses with CHD compared to healthy controls, median LV GLS (- 13.2% vs. - 18.9%; p < 0.007), RV GLS (- 7.9% vs. - 16.2%; p < 0.006), and LV strain rate (1.4 s-1 vs. 1.6 s-1; p < 0.003) were significantly higher (i.e., less negative). LV radial strain was without a statistically significant difference (20.7% vs. 22.6%; p = 0.1). Bivariate discriminant analysis for LV GLS and RV GLS revealed a sensitivity of 67% and specificity of 93% to differentiate between fetuses with CHD and healthy fetuses. CONCLUSION: Myocardial strain was successfully assessed in the human fetus, performing dynamic fetal cardiac MRI with DUS gating. Our study indicates that strain parameters may allow for differentiation between fetuses with and without CHD. CLINICAL RELEVANCE STATEMENT: Myocardial strain analysis by cardiac MRI with Doppler ultrasound gating and feature tracking may provide a new diagnostic approach for evaluation of fetal cardiac function in congenital heart disease. KEY POINTS: • MRI myocardial strain analysis has not been performed in human fetuses so far. • Myocardial strain was assessed in human fetuses using cardiac MRI with Doppler ultrasound gating. • MRI myocardial strain may provide a new diagnostic approach to evaluate fetal cardiac function.

2.
Eur Radiol ; 33(10): 6984-6992, 2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-37160424

RESUMEN

OBJECTIVES: To define and compare growth rates of the distal aorta in Marfan patients with and without aortic root replacement using serial MR angiography (MRA). METHODS: We retrospectively included 136 Marfan patients with a total of 645 MRAs who underwent a median of five MRAs (range: 2-13) at 1.5 T and 3 T in annual intervals. Of these, 41 patients (34.8 ± 12 years) had undergone aortic root replacement. The remaining 95 patients (29.0 ± 17 years) still had a native aorta and served as the control group. Thoracic aortic diameters were independently measured at eleven predefined levels. Estimated growth rates were calculated using a mixed effects model adjusted for sex, age, BMI, and medication. RESULTS: Marfan patients with aortic root replacement revealed the highest mean estimated growth rate in the proximal descending aorta (0.77 mm/year, CI: 0.31-1.21). Mean growth rates at all levels of the distal thoracic aorta were significantly higher in patients with aortic root replacement (0.28-0.77 mm/year) when compared to patients without aortic root replacement (0.03-0.07 mm/year) (all p < 0.001). Antihypertensive medication, gender, and BMI had no significant impact on the distal aortic growth rates. CONCLUSION: Distal thoracic aortic diameters increase at a significantly higher rate in Marfan patients with aortic root replacement compared to Marfan patients without aortic root replacement. Further studies are warranted to investigate if the increased growth rate of the distal thoracic aorta after aortic root replacement is caused by altered hemodynamics due to the rigid aortic root graft or due to the general genetic disposition of post-operative Marfan patients. CLINICAL RELEVANCE STATEMENT: High growth rates of the distal aorta after aortic root replacement underline the need for careful life-long aortic imaging of Marfan patients after aortic root replacement. KEY POINTS: • Aortic growth rates in Marfan patients with aortic root replacement are highest in the mid-aortic arch, the proximal- and mid-descending aorta. • Growth rates of the distal thoracic aorta are significantly higher in Marfan patients with aortic root replacement compared to Marfan patients without aortic root replacement. • Antihypertensive medication, gender, and BMI have no significant impact on distal aortic growth rates in Marfan patients.


Asunto(s)
Aneurisma de la Aorta Torácica , Síndrome de Marfan , Humanos , Síndrome de Marfan/complicaciones , Síndrome de Marfan/cirugía , Estudios de Seguimiento , Estudios Retrospectivos , Válvula Aórtica , Antihipertensivos , Dilatación , Aorta/diagnóstico por imagen , Aorta/cirugía , Aorta Torácica/diagnóstico por imagen , Aorta Torácica/cirugía , Angiografía , Dilatación Patológica , Aneurisma de la Aorta Torácica/cirugía
3.
Eur Radiol ; 33(9): 6278-6289, 2023 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-37032365

RESUMEN

OBJECTIVES: The study aimed to investigate the alterations of myocardial deformation responding to long-standing pressure overload and the effects of focal myocardial fibrosis using feature-tracking cardiac magnetic resonance (FT-CMR) in patients with resistant hypertension (RH). METHODS: Consecutive RH patients were prospectively recruited and underwent CMR at a single institution. FT-CMR analyses based on cine images were applied to measure left ventricular (LV) peak systolic global longitudinal (GLS), radial (GRS), and circumferential strain (GCS). Functional and morphological CMR variables, and late gadolinium enhancement (LGE) imaging were also obtained. RESULTS: A total of 50 RH patients (63 ± 12 years, 32 men) and 18 normotensive controls (57 ± 8 years, 12 men) were studied. RH patients had a higher average systolic blood pressure than controls (166 ± 21 mmHg vs. 116 ± 8 mmHg, p < 0.001) with the intake of 5 ± 1 antihypertensive drugs. RH patients showed increased LV mass index (78 ± 15 g/m2 vs. 61 ± 9 g/m2, p < 0.001), decreased GLS (- 16 ± 3% vs. - 19 ± 2%, p = 0.001) and GRS (41 ± 12% vs. 48 ± 8%, p = 0.037), and GCS was reduced by trend (- 17 ± 4% vs. - 19 ± 4%, p = 0.078). Twenty-one (42%) RH patients demonstrated a LV focal myocardial fibrosis (LGE +). LGE + RH patients had higher LV mass index (85 ± 14 g/m2 vs. 73 ± 15 g/m2, p = 0.007) and attenuated GRS (37 ± 12% vs. 44 ± 12%, p = 0.048) compared to LGE - RH patients, whereas GLS (p = 0.146) and GCS (p = 0.961) were similar. CONCLUSION: Attenuation of LV GLS and GRS, and GCS decline by tendency, might be adaptative changes responding to chronic pressure overload. There is a high incidence of focal myocardial fibrosis in RH patients, which is associated with reduced LV GRS. CLINICAL RELEVANCE STATEMENT: Feature-tracking CMR-derived myocardial strain offers insights into the influence of long-standing pressure overload and of a myocardial fibrotic process on cardiac deformation in patients with resistant hypertension. KEY POINTS: • Variations of left ventricular strain are attributable to the degree of myocardial impairment in resistant hypertensive patients. • Focal myocardial fibrosis of the left ventricle is associated with attenuated global radial strain. • Feature-tracking CMR provides additional information on the attenuation of myocardial deformation responding to long-standing high blood pressure.


Asunto(s)
Cardiomiopatías , Hipertensión , Masculino , Humanos , Función Ventricular Izquierda/fisiología , Ventrículos Cardíacos/diagnóstico por imagen , Medios de Contraste/farmacología , Gadolinio , Hipertensión/complicaciones , Hipertensión/diagnóstico por imagen , Imagen por Resonancia Cinemagnética/métodos , Fibrosis , Valor Predictivo de las Pruebas
4.
J Cardiovasc Magn Reson ; 25(1): 9, 2023 02 13.
Artículo en Inglés | MEDLINE | ID: mdl-36775827

RESUMEN

BACKGROUND: Four-dimensional (4D) flow cardiovascular magnetic resonance (CMR) is feasible for portal blood flow evaluation after placement of transjugular intrahepatic portosystemic shunts (TIPS) in patients with liver cirrhosis. However, clinical acceptance of 4D flow CMR in TIPS patients is limited due to the lack of validation studies. The purpose of this study was to validate 4D flow CMR-derived measurements in TIPS stent grafts using a three-dimensional (3D)-printed flow phantom. METHODS: A translucent flow phantom of the portal vasculature was 3D-printed. The phantom consisted of the superior mesenteric vein and the splenic vein draining into the portal vein, the TIPS-tract, and the hepatic vein. A TIPS stent graft (Gore® Viatorr®) was positioned within the TIPS-tract. Superior mesenteric vein and splenic vein served as inlets for blood-mimicking fluid. 4D flow CMR acquisitions were performed at 3T at preset flow rates of 0.8 to 2.8 l/min using velocity encoding of both 1.0 and 2.0 m/s. Flow rates and velocities were measured at predefined levels in the portal vasculature and within the stent graft. Accuracy of 4D flow CMR was assessed through linear regression with reference measurements obtained by flow sensors and two-dimensional (2D) phase contrast (PC) CMR. Intra- and interobserver agreement were assessed through Bland-Altman analyses. RESULTS: At a velocity encoding of 2.0 m/s, 4D flow CMR-derived flow rates and velocities showed an excellent correlation with preset flow rates and 2D PC CMR-derived flow velocities at all vascular levels and within the stent graft (all r ≥ 0.958, p ≤ 0.003). At a velocity encoding of 1.0 m/s, aliasing artifacts were present within the stent graft at flow rates ≥ 2.0 l/min. 4D flow CMR-derived measurements revealed high intra- and interobserver agreement. CONCLUSIONS: The in vitro accuracy and precision of 4D flow CMR is unaffected by the presence of TIPS stent grafts, suggesting that 4D flow CMR may be used to monitor TIPS patency in patients with liver cirrhosis.


Asunto(s)
Cirrosis Hepática , Stents , Humanos , Valor Predictivo de las Pruebas , Espectroscopía de Resonancia Magnética , Impresión Tridimensional
5.
J Magn Reson Imaging ; 58(5): 1499-1506, 2023 11.
Artículo en Inglés | MEDLINE | ID: mdl-36789724

RESUMEN

BACKGROUND: Patients with sickle cell disease (SCD) have a unique form of cardiomyopathy. However, left ventricular ejection fraction (LVEF) is often preserved. Monoplanar long-axis strain (LAS) can be assessed from MRI four-chamber views and may be better at detecting mild systolic dysfunction in these patients. PURPOSE: To compare LAS (monoplanar and biplanar) with LVEF as a marker of systolic dysfunction in SCD patients. STUDY TYPE: Retrospective. SUBJECTS: A total of 20 patients with genetically proven SCD (35 MRI examinations), 39 healthy controls, and 124 patients with systemic iron overload (for validation purposes). FIELD STRENGTH/SEQUENCE: 1.5 T/3 T. Cine balanced steady-state free-precession. ASSESSMENT: Rapidly assessed biplanar LAS from four- and two-chamber views was correlated with age and compared to LVEF by two operators. For validation, biplanar LAS was compared to global longitudinal strain (GLS) using MRI feature-tracking in 124 patients with systemic iron overload. STATISTICAL TESTS: Bland-Altman analysis. Wilcoxon-Mann-Whitney test and Spearman-rank correlation (correlation coefficient, rS ). Receiver-operating-characteristic (ROC) curve analysis (area under the curve, AUC). Bivariate discriminant analysis. Significance level: P < 0.01. RESULTS: There was strong correlation between biplanar LAS and GLS using feature tracking (rS  = 0.73). Interoperator agreement showed nonsignificant bias for biplanar LAS (-0.02%; ±95%-agreement interval -2.2%/2.2%, P = 0.9). Biplanar LAS increased significantly with age in controls (rS  = 0.70). In SCD patients, biplanar LAS was better correlated with age than monoplanar LAS (r2  = 0.53, standard error of estimate, SEE = 1.4% vs. r2  = 0.37;SEE = 2.0%). ROC analysis of LVEF, biplanar LAS, and age-adjusted Z-scores Z (LAS(age)) showed AUCs of 0.69, 0.75, and 0.86 for differentiation between SCD patients and controls. Bivariate discriminant analysis of biplanar Z (LAS(age)) and LVEF revealed a sensitivity of 63% and a specificity of 95%. DATA CONCLUSION: Rapidly assessed biplanar LAS demonstrated high diagnostic accuracy and was an indicator of mild systolic dysfunction in patients with SCD. Biplanar LAS provided more precise measurements than monoplanar, and normalization to age increased diagnostic accuracy. EVIDENCE LEVEL: 3. TECHNICAL EFFICACY: Stage 2.


Asunto(s)
Cardiomiopatías , Sobrecarga de Hierro , Disfunción Ventricular Izquierda , Humanos , Volumen Sistólico , Función Ventricular Izquierda , Estudios Retrospectivos , Imagen por Resonancia Magnética , Sobrecarga de Hierro/diagnóstico por imagen , Disfunción Ventricular Izquierda/diagnóstico por imagen , Disfunción Ventricular Izquierda/etiología
6.
Eur J Radiol ; 158: 110615, 2023 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-36434969

RESUMEN

PURPOSE: To investigate the influence of myocardial fibrosis on left ventricular (LV) diastolic filling patterns in triathletes compared to sedentary controls by cardiac magnetic resonance (CMR) imaging. METHOD: 101 male triathletes (43 ± 11 years) and 28 controls (41 ± 10 years) were recruited and underwent 1.5 T CMR including cine SSFP series, late gadolinium enhancement (LGE) imaging and T1 mapping. Functional and morphological parameters were obtained, and CMR-based LV diastolic filling parameters such as the early peak-filling rate (EPFR), atrial peak-filling rate (APFR) and peak-filling rate ratio (PFRR = EPFR/APFR) were determined by time-volume analysis of the cine series. RESULTS: Non-ischemic LGE was detected in 20 triathletes (20 %) and in none of the controls. Compared to controls LGE-negative (LGE-) triathletes showed similar EPFR (216 ± 58 ml/s/m2 vs 224 ± 69 ml/s/m2, P = 0.52) but lower APFR (120 ± 46 ml/s/m2 vs 147 ± 55 ml/s/m2, P < 0.05), resulting in higher PFRR (2.1 ± 1 vs 1.6 ± 0.5, P < 0.01). LGE-positive (LGE + ) triathletes had similar EPFR (212 ± 73 ml/s/m2, P = 0.798), but higher APFR (149 ± 50 ml/s/m2, P < 0.05) and decreased PFRR (1.6 ± 0.7, P < 0.05) compared to LGE- triathletes. LGE + triathletes had increased LV mass index (88 ± 10 g/m2 vs 80 ± 12 g/m2, P < 0.01) and extracellular volume (ECV) fraction (26.2 ± 2.7 % vs 24.4 ± 1.7 %, P < 0.001) compared to LGE- triathletes. CONCLUSIONS: Athletic activity leads to "supernormal" LV diastolic filling pattern in LGE- triathletes, which may be attributable to increased LV myocardial flexibility and elasticity. However, LGE + triathletes demonstrate a pseudo-normalization characterized by compensatory increase of atrial contraction. Possibly, due to reduced passive elasticity associated myocardial fibrosis.


Asunto(s)
Fibrilación Atrial , Cardiomiopatías , Humanos , Masculino , Medios de Contraste , Imagen por Resonancia Cinemagnética , Gadolinio , Cardiomiopatías/patología , Miocardio/patología , Fibrosis , Espectroscopía de Resonancia Magnética , Función Ventricular Izquierda , Valor Predictivo de las Pruebas
7.
Eur Radiol ; 33(3): 1687-1697, 2023 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-36269370

RESUMEN

OBJECTIVES: To compare the accuracy and precision of 3D-Dixon and 2D-SSFP MR-imaging for assessment of aortic diameter in Marfan patients. METHODS: This prospective single-center study investigated respiratory-gated 3D-Dixon and breath-hold 2D-SSFP non-contrast MR-imaging at 3 T in 47 Marfan patients (36.0 ± 13.2 years, 28♀,19♂). Two radiologists performed individual diameter measurements at five levels of the thoracic aorta and evaluated image quality on a four-grade scale (1 = poor, 4 = excellent) and artifacts (1 = severe, 4 = none). Aortic root diameters acquired by echocardiography served as a reference standard. Intraclass correlation coefficient, Bland-Altman analyses, F-test, t-test, and regression analyses were used to assess agreement between observers and methods. RESULTS: Greatest aortic diameters were observed at the level of the sinuses of Valsalva (SOV) for 3D-Dixon (38.2 ± 6.8 mm) and 2D-SSFP (38.3 ± 7.1 mm) (p = 0.53). Intra- and interobserver correlation of diameter measurements was excellent at all aortic levels for both 3D-Dixon (r = 0.94-0.99 and r = 0.94-0.98) and 2D-SSFP (r = 0.96-1.00 and r = 0.95-0.99). 3D-Dixon-derived and 2D-SSFP-derived diameter measurements at the level of the SOV revealed a strong correlation with echocardiographic measurements (r = 0.92, p < 0.001 and r = 0.93, p < 0.001, respectively). The estimated mean image quality at the level of SOV was higher for 2D-SSFP compared to that for 3D-Dixon (3.3 (95%-CI: 3.1-3.5) vs. 2.9 (95%-CI: 2.7-3.1)) (p < 0.001). Imaging artifacts were less at all aortic levels for 3D-Dixon compared to 2D-SSFP (3.4-3.8 vs. 2.8-3.1) (all p < 0.002). CONCLUSION: Respiratory-gated 3D-Dixon and breath-hold 2D-SSFP MR-imaging provide accurate and precise aortic diameter measurements. We recommend 3D-Dixon imaging for monitoring of aortic diameter in Marfan patients due to fewer imaging artifacts and the possibility of orthogonal multiplanar reformations of the aortic root. KEY POINTS: • Respiratory-gated 3D-Dixon and breath-hold 2D-SSFP imaging provide accurate and precise aortic diameter measurements in patients suffering from Marfan syndrome. • Imaging artifacts are stronger in 2D-SFFP imaging than in 3D-Dixon imaging. • We recommend 3D-Dixon imaging for monitoring of aortic diameter in Marfan patients due to fewer imaging artifacts and the possibility of orthogonal multiplanar reformations.


Asunto(s)
Síndrome de Marfan , Humanos , Síndrome de Marfan/diagnóstico por imagen , Estudios Prospectivos , Angiografía por Resonancia Magnética/métodos , Medios de Contraste , Imagenología Tridimensional/métodos , Imagen por Resonancia Magnética , Reproducibilidad de los Resultados
9.
PLoS One ; 17(12): e0279552, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36584085

RESUMEN

PURPOSE: Adrenal vein sampling (AVS) is the reference standard for evaluation of lateralized hormone production in primary aldosteronism. We aimed to investigate the impact of pre-interventional right renal vein (RRV) to right adrenal vein (RAV) distance measurement on fluoroscopy time, contrast agent exposure and radiation dose during AVS. MATERIALS AND METHODS: Forty-five patients with primary aldosteronism undergoing AVS were enrolled in our retrospective study and divided into three groups. In the group "ruler" (n = 14), RRV-RAV-distances were determined pre-interventionally by cross-sectional imaging (CT/MRI) and AVS was performed by one interventional radiologist with limited experience in AVS. CT/MRI-derived and fluoroscopy-derived RRV-RAV-distances were correlated for aimed cannulation of the RAV. Patients in group "no ruler" (n = 24, three interventional radiologists with limited experience in AVS) and in group "expert", (n = 7, one expert interventional radiologist) underwent AVS without pre-interventional estimation of RRV-RAV-distances. Procedure parameters (fluoroscopy time, contrast agent volume, radiation dose) of group "ruler" were compared to both other groups by Kruskal-Wallis rank-sum test. RESULTS: Correlation of CT/MRI-derived and fluoroscopy-derived RRV-RAV-distances was good (r = 0.74;p = 0.003). The median RRV-RAV-distance was 4.5cm at CT/MRI (95%-CI:4.2-5.0cm) and 4.0cm at fluoroscopy (95%-CI:3.8-4.5cm). Fluoroscopy time (p<0.0001), contrast agent exposure (p = 0.0003) and radiation dose (air kerma and dose area product both p = 0.038) were significantly lower in group "ruler" compared to group "no ruler" (all p<0.05), and similar to group "expert" (all p>0.05). CONCLUSIONS: CT/MRI-derived pre-interventional renal-adrenal vein distance measurements correlate well with angiographic distance measurements. Pre-interventional estimation of the RRV-RAV-distance allows for aimed cannulation of the RAV with potential reduction of fluoroscopy time, contrast agent exposure and radiation-dose during AVS.


Asunto(s)
Medios de Contraste , Hiperaldosteronismo , Humanos , Estudios Retrospectivos , Glándulas Suprarrenales/diagnóstico por imagen , Dosis de Radiación , Aldosterona
10.
J Clin Med ; 11(23)2022 Nov 28.
Artículo en Inglés | MEDLINE | ID: mdl-36498602

RESUMEN

Magnetic Resonance Imaging (MRI) is a reliable method, with a complementary role to Ultrasound (US) Echocardiography, that can be used to fully comprehend and precisely diagnose congenital cardiac malformations. Besides the anatomical study of the fetal cardiovascular system, it allows us to study the function of the fetal heart, remaining, at the same time, a safe adjunct to the classic fetal echocardiography. MRI also allows for the investigation of cardiac and placental diseases by providing information about hematocrit, oxygen saturation, and blood flow in fetal vessels. It is crucial for fetal medicine specialists and pediatric cardiologists to closely follow the advances of fetal cardiac MRI in order to provide the best possible care. In this review, we summarize the advance in techniques and their practical utility to date.

11.
PLoS One ; 17(2): e0262826, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35113893

RESUMEN

BACKGROUND: To identify magnetic resonance (MR) angiography derived predictors of progressive dilatation and surgery of the aortic root in Marfan syndrome. MATERIAL AND METHODS: We retrospectively included 111 patients (32.7±16.5 years, range: 7-75 years) with a total of 446 MR angiographies. Aortic diameter growth rates of the entire thoracic aorta and Z-scores were estimated from annual diameter measurements. Aortic root shape was subdivided into three different types: (T0) normal; (T1) localized dilatation; (T2) generalized aortic root dilatation. Aortic diameter, Z-score, age, and aortic root shape at baseline were tested as predictors of aortic root dilatation using a multivariate logistic regression model. RESULTS: The highest aortic growth rate was observed at the level of the sinuses of Valsalva. Higher aortic root diameters and Z-scores at baseline predicted an increased growth of the aortic root (p = 0.003 and p<0.001). Young age (<30 years) was a predictor for the increase of Z-scores when compared to patients ≥30 years (p = 0.019). 25/111 patients (22.5%) had a T0 aortic root shape, 59/111 patients (53.2%) had a T1 aortic root shape, and 27/111 patients (24.3%) had a T2 aortic root shape. Aortic root shape did not predict further aortic growth (p>0.05). However, significantly more patients undergoing surgery had a generalized aortic dilatation (19/28, 76.9%) than a localized aortic root dilatation (9/28, 32.1%) (p = 0.001). CONCLUSION: Larger baseline aortic root diameter and Z-score as well as young age predict solely progressive aortic root dilatation in Marfan patients. MR angiography derived type of aortic root shape does not predict aortic growth, but patients with generalized aortic root dilatation are referred more frequently for aortic surgery.


Asunto(s)
Síndrome de Marfan
12.
Clin Neuroradiol ; 32(1): 259-267, 2022 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-34709410

RESUMEN

PURPOSE: Anterior pituitary iron overload and volume shrinkage is common in patients with transfusion-dependent anemia and associated with growth retardation and hypogonadotropic hypogonadism. We investigated the accuracy of different MRI-based pituitary volumetric approaches and the relationship between pituitary volume and MRI-R2, particularly with respect to growth and hypogonadism. METHODS: In 43 patients with transfusion-dependent anemia (12-38 years) and 32 healthy controls (12-72 years), anterior pituitary volume was measured by a sagittal T1 GRE 3D sequence at 1.5T and analyzed by 3D semi-automated threshold volumetry (3D-volumetry). This reference method was compared with planimetric 2D-volumetry, approximate volume calculations, and pituitary height. Using a multiple SE sequence, pituitary iron as MRI-R2 was assessed by fitting proton signal intensities to echo times. Growth and hypogonadism were obtained from height percentile tables and patients' medical charts. From body surface area and age adjusted anterior pituitary volumes of controls, Z­scores were calculated for all subjects. Separation of controls and patients with respect to Z and pituitary R2 was performed by bivariate linear discriminant analysis. RESULTS: Tuned 2D volumes showed highest agreement with reference 3D-volumes (bias -4.8%; 95% CI:-8.8%|-0.7%). A linear discriminant equation of Z = -17.8 + 1.45 · R2 revealed optimum threshold sensitivity and specificity of 65% and 100% for discrimination of patients from controls, respectively. Of correctly classified patients 71% and 75% showed hypogonadism and growth retardation, respectively. CONCLUSION: Accurate assessment of anterior pituitary size requires 3D or precise 2D volumetry, with shorter analysis time for the latter. Anterior pituitary volume Z­scores and R2 allow for the identification of patients at risk of pituitary dysfunction.


Asunto(s)
Anemia , Sobrecarga de Hierro , Humanos , Hierro , Imagen por Resonancia Magnética/métodos , Hipófisis/diagnóstico por imagen
13.
Insights Imaging ; 12(1): 159, 2021 Nov 03.
Artículo en Inglés | MEDLINE | ID: mdl-34731305

RESUMEN

BACKGROUND: This cardiovascular magnetic resonance (CMR) study investigates the impact of trabeculae and papillary muscles (TPM) on diastolic function parameters by differentiation of the time-volume curve. Differentiation causes additional problems, which is overcome by standardization. METHODS: Cine steady-state free-precession imaging at 1.5 T was performed in 40 healthy volunteers stratified for age (age range 7-78y). LV time-volume curves were assessed by software-assisted delineation of endocardial contours from short axis slices applying two different methods: (1) inclusion of TPM into the myocardium and (2) inclusion of TPM into the LV cavity blood volume. Diastolic function was assessed from the differentiated time-volume curves defining the early and atrial peaks, their filling rates, filling volumes, and further dedicated diastolic measures, respectively. RESULTS: Only inclusion of TPM into the myocardium allowed precise assessment of early and atrial peak filling rates (EPFR, APFR) with clear distinction of EPFR and APFR expressed by the minimum between the early and atrial peak (EAmin) (100% vs. 36% for EAmin < 0.8). Prediction of peak filling rate ratios (PFRR) and filling volume ratios (FVR) by age was superior with inclusion of TPM into the myocardium compared to inclusion into the blood pool (r2 = 0.85 vs. r2 = 0.56 and r2 = 0.89 vs. r2 = 0.66). Standardization problems were overcome by the introduction of a third phase (mid-diastole, apart from diastole and systole) and fitting of the early and atrial peaks in the differentiated time-volume curve. CONCLUSIONS: Only LV volumetry with inclusion of TPM into the myocardium allows precise determination of diastolic measures and prevents methodological artifacts.

14.
Acta Obstet Gynecol Scand ; 100(1): 67-73, 2021 01.
Artículo en Inglés | MEDLINE | ID: mdl-32649773

RESUMEN

INTRODUCTION: Cardiovascular magnetic resonance imaging (MRI) is established in cardiac evaluation in postnatal life, but its application to the fetus has been hampered by technical limitations. We aimed to investigate the feasibility of dynamic MRI of the fetal aortic isthmus using a magnetic resonance-compatible Doppler ultrasound device for cardiac gating. MATERIAL AND METHODS: This prospective study included 19 fetuses at a median gestational age of 32.3 weeks (range 26-38 weeks). Imaging of the fetal aortic isthmus was assessed by (a) dynamic steady-state free precession MRI using a magnetic resonance-compatible Doppler ultrasound device for cardiac gating and (b) echocardiography. Diameters of the aortic isthmus were compared by two blinded observers. Magnetic resonance image quality was assessed independently by two observers using a four-point scale (1 = low quality, 4 = high quality). Furthermore, we performed four-dimensional flow MRI of the fetal aorta in three of these fetuses. RESULTS: The Doppler ultrasound device for cardiac gating allowed successful dynamic MRI examinations of the aortic isthmus in 18/19 (95%) fetuses. Evaluation of the fetal aortic isthmus was possible by both MRI (15/18, 83%) and echocardiography (16/18, 89%) (P < .05). Diameters of the aortic isthmus were concordant for MRI (3.8 ± 0.9 mm) and echocardiography (4.0 ± 1.1 mm), with a variability of 10.8% (bias -2.3%, 95% limits of agreement -23.9% to 19.3%). Overall magnetic resonance image quality was good (score 4 in 67% and score 3 in 23%) with good inter-observer agreement (κ = 0.75; 95% CI 0.5-1). Fetal four-dimensional flow MRI allowed visualization of aortic flow dynamics. CONCLUSIONS: Doppler ultrasound-gating allows dynamic MRI of the fetal aorta with the potential to serve as a complementary imaging tool in cases where echocardiography is inconclusive.


Asunto(s)
Aorta Torácica/diagnóstico por imagen , Imagen por Resonancia Magnética/métodos , Diagnóstico Prenatal/métodos , Ultrasonografía Prenatal/métodos , Adulto , Estudios de Factibilidad , Femenino , Edad Gestacional , Humanos , Embarazo , Estudios Prospectivos , Ultrasonografía Doppler
15.
J Cancer Res Clin Oncol ; 147(2): 549-559, 2021 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-32809056

RESUMEN

PURPOSE: Controversies exist in regard to surgical neck management in total laryngectomies (TL). International guidelines do not sufficiently discriminate neck sides and sublevels, or minimal neck-dissection nodal yield (NY). METHODS: Thirty-seven consecutive primary TL cases from 2009 to 2019 were retrospectively analyzed in terms of local tumor growth using a previously established imaging scheme, metastatic neck involvement, and NY impact on survival. RESULTS: There was no case of level IIB involvement on any side. For type A and B tumor midline involvement, no positive contralateral lymph nodes were found. Craniocaudal tumor extension correlated with contralateral neck involvement (OR: 1.098, p = 0.0493) and showed increased involvement when extending 33 mm (p = 0.0134). Using a bilateral NY of ≥ 24 for 5-year overall survival (OS) and ≥ 26 for 5-year disease-free survival (DFS) gave significantly increased rate advantages of 64 and 56%, respectively (both p < 0.0001). CONCLUSIONS: This work sheds light on regional metastatic distribution pattern and its influence on TL cases. An NY of n ≥ 26 can be considered a desirable benchmark for bilateral selective neck dissections as it leads to improved OS and DFS. Therefore, an omission of distinct neck levels cannot be promoted at this time.


Asunto(s)
Neoplasias Laríngeas/cirugía , Laringectomía/métodos , Disección del Cuello/métodos , Carcinoma de Células Escamosas de Cabeza y Cuello/cirugía , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Neoplasias Laríngeas/mortalidad , Neoplasias Laríngeas/patología , Masculino , Persona de Mediana Edad , Estadificación de Neoplasias , Estudios Retrospectivos , Carcinoma de Células Escamosas de Cabeza y Cuello/mortalidad , Carcinoma de Células Escamosas de Cabeza y Cuello/patología
17.
J Cardiovasc Magn Reson ; 22(1): 29, 2020 04 30.
Artículo en Inglés | MEDLINE | ID: mdl-32354361

RESUMEN

BACKGROUND: Aortic valve repair has become a treatment option for adults with symptomatic bicuspid (BAV) or unicuspid (UAV) aortic valve insufficiency. Our aim was to demonstrate the feasibility of 4D flow cardiovascular magnetic resonance (CMR) to assess the impact of aortic valve repair on changes in blood flow dynamics in patients with symptomatic BAV or UAV. METHODS: Twenty patients with adult congenital heart disease (median 35 years, range 18-64; 16 male) and symptomatic aortic valve regurgitation (15 BAV, 5 UAV) were prospectively studied. All patients underwent 4D flow CMR before and after aortic valve repair. Aortic valve regurgitant fraction and systolic peak velocity were estimated. The degree of helical and vortical flow was evaluated according to a 3-point scale. Relative flow displacement and wall shear stress (WSS) were quantified at predefined levels in the thoracic aorta. RESULTS: All patients underwent successful aortic valve repair with a significant reduction of aortic valve regurgitation (16.7 ± 9.8% to 6.4 ± 4.4%, p < 0.001) and systolic peak velocity (2.3 ± 0.9 to 1.9 ± 0.4 m/s, p = 0.014). Both helical flow (1.6 ± 0.6 vs. 0.9 ± 0.5, p < 0.001) and vortical flow (1.2 ± 0.8 vs. 0.5 ± 0.6, p = 0.002) as well as both flow displacement (0.3 ± 0.1 vs. 0.25 ± 0.1, p = 0.031) and WSS (0.8 ± 0.2 N/m2 vs. 0.5 ± 0.2 N/m2, p < 0.001) in the ascending aorta were significantly reduced after aortic valve repair. CONCLUSIONS: 4D flow CMR allows assessment of the impact of aortic valve repair on changes in blood flow dynamics in patients with bicuspid aortic valve disease.


Asunto(s)
Aorta Torácica/diagnóstico por imagen , Insuficiencia de la Válvula Aórtica/cirugía , Válvula Aórtica/anomalías , Aortografía , Anuloplastia de la Válvula Cardíaca , Enfermedades de las Válvulas Cardíacas/cirugía , Hemodinámica , Interpretación de Imagen Asistida por Computador , Imagen por Resonancia Cinemagnética , Adulto , Aorta Torácica/fisiopatología , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/fisiopatología , Válvula Aórtica/cirugía , Insuficiencia de la Válvula Aórtica/diagnóstico por imagen , Insuficiencia de la Válvula Aórtica/fisiopatología , Enfermedad de la Válvula Aórtica Bicúspide , Velocidad del Flujo Sanguíneo , Estudios de Factibilidad , Femenino , Enfermedades de las Válvulas Cardíacas/diagnóstico por imagen , Enfermedades de las Válvulas Cardíacas/fisiopatología , Humanos , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Estudios Prospectivos , Recuperación de la Función , Factores de Tiempo , Resultado del Tratamiento , Adulto Joven
18.
Int J Cardiovasc Imaging ; 36(8): 1533-1542, 2020 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-32314122

RESUMEN

Aortic diameter measurements play a crucial role for the indication of aortic root surgery in Marfan patients. However, for magnetic resonance angiography (MRA)-derived measurements, there is no consensus on whether the aortic wall should be included or excluded in the aortic diameter. The purpose of this retrospective study was to compare the reliability of non-contrast bright blood MRA aortic inner-to-inner and outer-to-outer edge measurements in patients with Marfan syndrome. Forty Marfan patients underwent ECG-gated balanced steady-state free-precession MRA of the aorta at 1.5 T. Two readers independently performed inner and outer measurements at different aortic levels. They rated the image quality of the delineation of both inner and outer vessel wall edges on a four-point scale. MRA-derived diameters of the sinuses of Valsalva were compared with echocardiography-derived diameters. Aortic vessel wall delineation score was rated higher at all levels for inner than for outer vessel walls (p < 0.001). Inter- and intraobserver variances of aortic measurements were smaller for inner-to-inner measurements at the sinuses of Valsalva, sinotubular junction and ascending aorta (p < 0.03). There was a difference of 1.1 ± 2.3 mm for inner MRA measurements (p = 0.014) and 6.9 ± 3.1 mm for outer MRA measurements (p < 0.001) when compared to echocardiographic leading-edge measurements. Inner-to-inner vessel wall diameter measurements in non-contrast bright blood MRA provide more reliable diameters when compared to outer-to-outer vessel wall measurements of the aortic root. Therefore, we propose to rely on inner rather than outer aortic wall measurements in non-contrast-MRA when monitoring aortic diameters in patients with Marfan syndrome.


Asunto(s)
Aorta/diagnóstico por imagen , Aneurisma de la Aorta/diagnóstico por imagen , Angiografía por Resonancia Magnética , Síndrome de Marfan/complicaciones , Seno Aórtico/diagnóstico por imagen , Adolescente , Adulto , Aorta/fisiopatología , Aneurisma de la Aorta/etiología , Aneurisma de la Aorta/fisiopatología , Técnicas de Imagen Sincronizada Cardíacas , Dilatación Patológica , Electrocardiografía , Femenino , Humanos , Masculino , Síndrome de Marfan/diagnóstico , Persona de Mediana Edad , Variaciones Dependientes del Observador , Valor Predictivo de las Pruebas , Reproducibilidad de los Resultados , Estudios Retrospectivos , Seno Aórtico/fisiopatología , Remodelación Vascular , Adulto Joven
19.
Eur J Radiol ; 106: 85-91, 2018 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-30150056

RESUMEN

PURPOSE: To quantitatively assess T2 relaxation times of the anterolateral femoral cartilage following anterior cruciate ligament (ACL)-reconstruction with and without a positive deep lateral femoral notch sign (DLNS) at post-traumatic MRI. MATERIALS AND METHODS: In 52 patients post-traumatic MRI as well as 12 months after ACL-rupture (ACLR) and surgical treatment were analysed. In 28 patients a positive DLNS was present at post-traumatic MRI. For quantitative analysis, T2 relaxation time measurements (7 TE: 10-70 ms) were performed at time of re-evaluation. Three polygonal ROIs encompassing the full cartilage layer were placed in the anterolateral femoral cartilage. Clinical assessment included Lysholm-Tegner-Activity-Score, Rasmussen's clinical score and modified Cincinnati-Rating-System-Questionnaire. Description and differences were calculated as means and confidence intervals of means, controlled for the cluster effect of person, if appropriate. RESULTS: In patients with a positive DLNS after ACLR, relaxation times in the notch region were significantly prolonged compared to patients without a positive DLNS (Δ 7.4 ms, CI: 5.6-9.2; p-value <0.001) as well as to the adjacent anterior (Δ 5.7 ms, CI: 4.7-6.7; p-value <0.001) and central femoral cartilage (Δ 6.6 ms, CI: 5.7-7.6; p-value <0.001). Solely insignificant differences were noticed in the performed clinical scores comparing the two groups (p > 0.05). CONCLUSION: Significantly prolonged T2 relaxation times of the anterolateral femoral cartilage were found in patients with a positive DLNS following ACL-reconstruction compared to patients without a DLNS. Based on these results, it has to be assumed that a positive DLNS is associated with higher cartilage degradation.


Asunto(s)
Lesiones del Ligamento Cruzado Anterior/fisiopatología , Lesiones del Ligamento Cruzado Anterior/cirugía , Reconstrucción del Ligamento Cruzado Anterior , Cartílago Articular/diagnóstico por imagen , Cartílago Articular/fisiopatología , Imagen por Resonancia Magnética/métodos , Adulto , Cartílago Articular/cirugía , Femenino , Estudios de Seguimiento , Humanos , Masculino
20.
J Cardiovasc Magn Reson ; 20(1): 17, 2018 03 12.
Artículo en Inglés | MEDLINE | ID: mdl-29530064

RESUMEN

BACKGROUND: Fetal cardiovascular magnetic resonance (CMR) imaging may provide a valuable adjunct to fetal echocardiography in the evaluation of congenital cardiovascular pathologies. However, dynamic fetal CMR is difficult due to the lack of direct in-utero cardiac gating. The aim of this study was to investigate the effectiveness of a newly developed Doppler ultrasound (DUS) device in humans for fetal CMR gating. METHODS: Fifteen fetuses (gestational age 30-39 weeks) were examined using 1.5 T CMR scanners at three different imaging sites. A newly developed CMR-compatible DUS device was used to generate gating signals from fetal cardiac motion. Gated dynamic balanced steady-state free precession images were acquired in 4-chamber and short-axis cardiac views. Gating signals during data acquisition were analyzed with respect to trigger variability and sensitivity. Image quality was assessed by measuring endocardial blurring (EB) and by image evaluation using a 4-point scale. Left ventricular (LV) volumetry was performed using the single-plane ellipsoid model. RESULTS: Gating signals from the fetal heart were detected with a variability of 26 ± 22 ms and a sensitivity of trigger detection of 96 ± 4%. EB was 2.9 ± 0.6 pixels (4-chamber) and 2.5 ± 0.1 pixels (short axis). Image quality scores were 3.6 ± 0.6 (overall), 3.4 ± 0.7 (mitral valve), 3.4 ± 0.7 (foramen ovale), 3.6 ± 0.7 (atrial septum), 3.7 ± 0.5 (papillary muscles), 3.8 ± 0.4 (differentiation myocardium/lumen), 3.7 ± 0.5 (differentiation myocardium/lung), and 3.9 ± 0.4 (systolic myocardial thickening). Inter-observer agreement for the scores was moderate to very good (kappa 0.57-0.84) for all structures. LV volumetry revealed mean values of 2.8 ± 1.2 ml (end-diastolic volume), 0.9 ± 0.4 ml (end systolic volume), 1.9 ± 0.8 ml (stroke volume), and 69.1 ± 8.4% (ejection fraction). CONCLUSION: High-quality dynamic fetal CMR was successfully performed using a newly developed DUS device for direct fetal cardiac gating. This technique has the potential to improve the utility of fetal CMR in the evaluation of congenital pathologies.


Asunto(s)
Técnicas de Imagen Sincronizada Cardíacas , Ecocardiografía Doppler , Corazón Fetal/diagnóstico por imagen , Cardiopatías Congénitas/diagnóstico por imagen , Imagen por Resonancia Cinemagnética , Ultrasonografía Prenatal/métodos , Boston , Técnicas de Imagen Sincronizada Cardíacas/instrumentación , Ecocardiografía Doppler/instrumentación , Diseño de Equipo , Corazón Fetal/fisiopatología , Alemania , Edad Gestacional , Cardiopatías Congénitas/embriología , Cardiopatías Congénitas/fisiopatología , Frecuencia Cardíaca Fetal , Humanos , Imagen por Resonancia Cinemagnética/instrumentación , Valor Predictivo de las Pruebas , Volumen Sistólico , Suecia , Transductores , Ultrasonografía Prenatal/instrumentación , Función Ventricular Izquierda
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...