Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
Clin Res Cardiol ; 110(3): 411-420, 2021 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-33074368

RESUMEN

AIMS: Transcatheter mitral valve replacement (TMVR) with dedicated devices promises to fill the treatment gap between open-heart surgery and edge-to-edge repair for patients with severe mitral regurgitation (MR). We herein present a single-centre experience of a TMVR series with two transapical devices. METHODS AND RESULTS: A total of 11 patients were treated with the Tendyne™ (N = 7) or the Tiara™ TMVR systems (N = 4) from 2016 to 2020 either as compassionate-use procedures or as commercial implants. Clinical and echocardiographic data were collected at baseline, discharge and follow-up and are presented in accordance with the Mitral Valve Academic Research Consortium (MVARC) definitions. The study cohort [age 77 years (73, 84); 27.3% male] presented with primary (N = 4), secondary (N = 5) or mixed (N = 2) MR etiology. Patients were symptomatic (all NYHA III/IV) and at high surgical risk [logEuroSCORE II 8.1% (4.0, 17.4)]. Rates of impaired RV function (72.7%), severe pulmonary hypertension (27.3%), moderate or severe tricuspid regurgitation (63.6%) and prior aortic valve replacement (63.6%) were high. Severe mitral annulus calcification was present in two patients. Technical success was achieved in all patients. In 90.9% (N = 10) MR was completely eliminated (i.e. no or trace MR). Procedural and 30-day mortality were 0.0%. At follow-up NYHA class was I/II in the majority of patients. Overall mortality after 3 and 6 months was 10.0% and 22.2%. CONCLUSIONS: TMVR was performed successfully in these selected patients with complete elimination of MR in the majority of patients. Short-term mortality was low and most patients experienced persisting functional improvement.


Asunto(s)
Cateterismo Cardíaco/métodos , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Prótesis Valvulares Cardíacas , Insuficiencia de la Válvula Mitral/cirugía , Válvula Mitral/cirugía , Anciano , Anciano de 80 o más Años , Ecocardiografía , Diseño de Equipo , Femenino , Estudios de Seguimiento , Humanos , Masculino , Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/diagnóstico , Estudios Retrospectivos , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento
3.
Int J Cardiol ; 232: 247-254, 2017 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-28118931

RESUMEN

OBJECTIVES: Transcatheter Aortic Valve Implantation (TAVI) can be performed via the transaxillary approach, but data about complications and procedural outcome is limited. INTRODUCTION: TAVI is an established treatment option for patients at high risk for conventional aortic valve replacement. Nowadays, the transfemoral approach is the most commonly used access for TAVI. Nevertheless, the transfemoral access is not suitable in many patients necessitating alternative approaches. METHODS: We analyzed the outcome of 100 consecutive cases receiving percutaneous transaxillary TAVI at two different hospitals. Data were retrospectively analyzed by means of procedural, hemodynamic and clinical outcome. In addition, 1st versus 2nd generation devices were analyzed. RESULTS: Mean age was 78.2±2.1years and the logEuroSCORE I was 24.6±13.9%. Transaxillary TAVI was performed in 85% via the left and in 15% via the right axillary artery. Device success was achieved in 95%. In general, there was a clear learning curve with this approach. No patient experienced a major and 11% a minor access site complication. There was one procedural death (annular rupture) and one peri-procedural TIA. 23% of the patients received a new pacemaker. At discharge, effective orifice area was 1.94±0.16cm2 and the mean aortic gradient was 6.8±2.1mmHg. Moderate aortic regurgitation/paravalvular leakage was documented in two patients. Mortality rates at 30days and one year were 6% and 14.8%. Last but not least, 2nd generation devices showed improved procedural outcomes. CONCLUSIONS: The percutaneous transaxillary access for TAVI is technically feasible and safe thereby yielding excellent clinical results. CONDENSED ABSTRACT: We investigated In 100 consecutive patients undergoing percutaneous transaxillary transcatheter aortic valve implantation thereby demonstrating that this approach is technically feasible and safe with acceptable numbers of minor vascular complications.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Cateterismo Cardíaco/métodos , Prótesis Valvulares Cardíacas , Medición de Riesgo , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Anciano , Estenosis de la Válvula Aórtica/diagnóstico , Arteria Axilar , Ecocardiografía Transesofágica , Femenino , Estudios de Seguimiento , Alemania/epidemiología , Humanos , Incidencia , Masculino , Tomografía Computarizada Multidetector , Complicaciones Posoperatorias/epidemiología , Diseño de Prótesis , Estudios Retrospectivos , Factores de Riesgo , Tasa de Supervivencia/tendencias , Resultado del Tratamiento
4.
Internist (Berl) ; 57(3): 284-8, 2016 Mar.
Artículo en Alemán | MEDLINE | ID: mdl-26782091

RESUMEN

We report a case of an extracutaneous involvement of pyoderma gangrenosum. The patient initially presented with multiple sterile abscesses of the skin, heart, prostate, and kidney. Extracutaneous involvement in pyoderma gangrenosum is very rare. Confirmation of the diagnosis was only possible after exclusion of other relevant differential diagnoses. Continuous search for microbes proved negative and after an empiric therapeutic attempt with prednisolone, the patient improved quickly. However, each time we reduced the steroids even in combination with methotrexate or with azathioprine the patient relapsed. Only after therapy with the tumor necrosis factor-α-inhibitor infliximab was permanent remission achieved.


Asunto(s)
Absceso/diagnóstico , Absceso/tratamiento farmacológico , Infliximab/administración & dosificación , Piodermia Gangrenosa/diagnóstico , Piodermia Gangrenosa/tratamiento farmacológico , Viaje , Anciano , Fármacos Dermatológicos/administración & dosificación , Diagnóstico Diferencial , Humanos , América Latina , Masculino , Resultado del Tratamiento
5.
Minerva Cardioangiol ; 63(5): 359-69, 2015 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-26198875

RESUMEN

The Symetis ACURATE TA and ACURATE neo technology is a novel transcatheter heart valve for treatment of aortic valvular stenosis. This review illustrates the implantation steps, which are designed for an easy and intuitive transapical and transfemoral TAVI procedure. The most important difference to other self-expanding platforms is the top-down deployment with minimal protrusion of the stent towards the left ventricular outflow tract. In addition, the supra-annularly placed porcine leaflets provide very low gradients and the pericardial skirt acts very effectively to seal against paravalvular leaks. This review reports about the hemodynamic features, low rates of paravalvular leaks and very low rates of pacemaker implantation, which have been observed in various registries. Meanwhile more than 3000 patients have been treated worldwide and additional registries are currently under investigation.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Animales , Hemodinámica , Humanos , Diseño de Prótesis , Stents , Porcinos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...