1.
Am J Otolaryngol ; 45(5): 104424, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-39094304

RESUMEN

PURPOSE: Diagnostic endoscopy with biopsy under general anesthesia (DE-GA) is still considered as the established standard to assess laryngopharyngeal cancer patients. Office-based flexible laryngoscopic biopsy (FLB) offers an alternative, but the effect on oncological outcome remains uncertain. Therefore, the diagnostic process and survival of patients undergoing FLB, compared to those undergoing DE-GA were evaluated. METHODS: Patients suspected of laryngopharyngeal cancer who underwent FLB were evaluated. Patients with FLB-confirmed squamous cell carcinoma (SCC) were matched with DE-GA patients based on tumor site, T-classification, N-classification, age, and p16 overexpression. Time from first visit to diagnosis (FVD), time to treatment interval (TTI), disease-specific survival (DSS) and overall survival (OS) were analyzed. RESULTS: FLB yielded a definitive diagnosis in 155/164 (95 %) patients. No complications were observed. Ninety-eight of the 124 patients in which FLB revealed a SCC received curative treatment and were compared with 98 matched patients who underwent DE-GA. Median FVD interval was 6 days after FLB and 15 days after DE-GA (p < 0.001). Median TTI interval (FLB: 28 days, DE-GA: 28 days) was equal (p = 0.91). Oncological outcomes were comparable (p > 0.05) between FLB (OS: 2-yr: 76 %, 5-yr: 42 %; DSS: 2-yr: 86 %, 5-yr: 85 %) and DE-GA groups (OS: 2-yr: 76 %, 5-yr: 50 %; DSS: 2-yr: 81 %, 5-yr: 79 %). CONCLUSION: FLB in the outpatient setting demonstrates a high diagnostic accuracy, is safe, accelerates the diagnostic process and has no negative effects on clinical outcome compared to DE-GA. Therefore, FLB should be considered as the standard diagnostic procedure in patients suspected of laryngopharyngeal cancer.


Asunto(s)
Anestesia General , Carcinoma de Células Escamosas , Neoplasias Laríngeas , Laringoscopía , Humanos , Masculino , Laringoscopía/métodos , Femenino , Persona de Mediana Edad , Anciano , Biopsia/métodos , Neoplasias Laríngeas/patología , Neoplasias Laríngeas/diagnóstico , Neoplasias Laríngeas/mortalidad , Carcinoma de Células Escamosas/patología , Carcinoma de Células Escamosas/diagnóstico , Carcinoma de Células Escamosas/mortalidad , Factores de Tiempo , Neoplasias Faríngeas/patología , Neoplasias Faríngeas/mortalidad , Neoplasias Faríngeas/diagnóstico , Anciano de 80 o más Años , Tasa de Supervivencia , Adulto , Estudios Retrospectivos
2.
J Laryngol Otol ; 138(4): 425-430, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-37880146

RESUMEN

BACKGROUND: Fibre-optic laryngoscopy is still widely used in daily clinical practice; however, high-definition laryngoscopy using narrow band imaging could be more reliable in characterising pharyngeal and laryngeal lesions. METHODS: Endoscopic videos were assessed in a tertiary referral hospital by 12 observers with different levels of clinical experience. Thirty pairs of high-definition laryngoscopy with narrow band imaging and fibre-optic laryngoscopy videos were judged twice, with an interval of two to four weeks, in a random order. Inter- and intra-observer reliability, sensitivity and specificity were calculated in terms of detecting a malignant lesion and a specific histological entity, for beginners, trained observers and experts. RESULTS: Using high-definition laryngoscopy with narrow band imaging, inter-observer reliability for detecting malignant lesions increased from moderate to substantial in trained observers and experts (high-definition laryngoscopy with narrow band imaging κ = 0.66 and κ = 0.77 vs fibre-optic laryngoscopy κ = 0.51 and κ = 0.56, for trained observers and experts respectively) and sensitivity increased by 16 per cent. CONCLUSION: Inter-observer reliability increased with the level of clinical experience, especially when using high-definition laryngoscopy with narrow band imaging.


Asunto(s)
Neoplasias Laríngeas , Laringe , Humanos , Laringoscopía/métodos , Imagen de Banda Estrecha/métodos , Reproducibilidad de los Resultados , Laringe/diagnóstico por imagen , Laringe/patología , Endoscopía , Neoplasias Laríngeas/diagnóstico por imagen , Neoplasias Laríngeas/patología
3.
Eur Arch Otorhinolaryngol ; 278(6): 1927-1932, 2021 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-33606082

RESUMEN

PURPOSE: This study aims to analyse differences in fiberoptic laryngoscopy (FOL) versus high definition laryngoscopy (HDL) by examining videolaryngoscopy images by a large group of observers with different levels of clinical expertise in ear, nose and throat (ENT) medicine. METHODS: This study is a 111 observer paired analysis of laryngoscopy videos during an interactive presentation. During a National Meeting of the Dutch Society of ENT/Head and Neck Surgery, observers assessed both FOL and HDL videos of nine cases with additional clinical information. Observers included 41 ENT consultants (36.9%), 34 ENT residents (30.6%), 22 researchers with Head and Neck interest (19.8%) and 14 with unspecified clinical expertise (12.6%). For both laryngoscopic techniques, sensitivity, specificity, positive and negative predictive value and diagnostic accuracy were determined for identifying a normal glottis, hyperkeratosis, radiotherapy adverse effects and squamous cell carcinoma. The sensitivities for FOL and HDL were analysed with regard to the different levels of clinical expertise. RESULTS: The overall sensitivity for correctly identifying the specific histological entity was higher in HDL (FOL 61% vs HDL 66.3%, p < 0.05). HDL was superior to FOL in identifying a normal glottis (FOL 68.1% vs HDL 91.6%, p < 0.01) and squamous cell carcinoma (FOL 70.86% vs HDL 79.41%, p = 0.02). Residents and researchers with Head and Neck interest diagnosed laryngeal lesions more correctly with HDL (p < 0.05). CONCLUSIONS: In a large population of observers with different levels of clinical expertise, HDL is superior to FOL in identifying laryngeal lesions.


Asunto(s)
Laringoscopios , Laringe , Laringoscopía , Valor Predictivo de las Pruebas , Grabación de Cinta de Video
4.
Clin Otolaryngol ; 45(1): 119-125, 2020 01.
Artículo en Inglés | MEDLINE | ID: mdl-31747481

RESUMEN

OBJECTIVES: High definition laryngoscopy (HDL) could lead to better interpretation of the pharyngeal and laryngeal mucosa than regularly used fiberoptic laryngoscopy (FOL). The primary aim of this study is to quantify the diagnostic advantage of HDL over FOL in detecting mucosal anomalies in general, in differentiating malignant from benign lesions and in predicting specific histological entities. The secondary aim is to analyse image quality of both laryngoscopes. DESIGN: Retrospective paired analysis with multiple observers evaluating endoscopic videos simulating daily clinical practice. SETTING: A tertiary referral hospital. PARTICIPANTS: In 36 patients, both FOL and HDL videos were obtained. Six observers were provided with additional clinical information, and 36 FOL and HDL videos were evaluated in a randomised order. MAIN OUTCOME MEASURES: Sensitivity, specificity, positive and negative predictive value and diagnostic accuracy of observers using both flexible laryngoscopes were calculated for detection of mucosal lesions in general and uncovering malignant lesions. Sensitivities were calculated for prediction of specific histological entities. Image quality (scale 1-10) was assessed for both flexible laryngoscopes. RESULTS: HDL reached higher sensitivity compared to FOL for detection of mucosal abnormalities in general (96.0% vs 90.4%; P = .03), differentiating malignant from benign lesions (91.7% vs 79.8%; P = .03) and prediction of specific histological entities (59.7% vs 47.2%; P < .01). Image quality was judged better with HDL in comparison with FOL (mean: 8.4 vs 5.4, P < .01). CONCLUSIONS: HDL is superior to FOL in detecting mucosal anomalies in general, malignancies and specific histological entities. Image quality is considered as superior using HDL compared to FOL.


Asunto(s)
Tecnología de Fibra Óptica/métodos , Aumento de la Imagen/métodos , Enfermedades de la Laringe/diagnóstico , Laringoscopía/métodos , Enfermedades Faríngeas/diagnóstico , Grabación en Video , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Persona de Mediana Edad , Curva ROC , Estudios Retrospectivos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA