Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
J Vet Cardiol ; 52: 61-67, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38430823

RESUMEN

A dog was presented for lameness, fever, and extreme lethargy. On physical exam, a new heart murmur, arrhythmia, and joint effusion were detected. These findings were not detected two months prior. A diagnostic work-up confirmed septic suppurative inflammation in multiple joints. Echocardiogram revealed aortic valvular endocarditis along with a communication, as a consequence of a fistula, that extended from just below the aortic sinotubular junction to the left atrial lumen. Due to a poor prognosis, humane euthanasia was elected. Necropsy and histopathology confirmed infective endocarditis of the aortic valve and an aorto-left atrial fistulous tract extending from the left coronary sinus of the aortic valve to the lumen of left atrium.


Asunto(s)
Enfermedades de los Perros , Ecocardiografía , Atrios Cardíacos , Animales , Perros , Enfermedades de los Perros/patología , Enfermedades de los Perros/diagnóstico por imagen , Atrios Cardíacos/patología , Atrios Cardíacos/diagnóstico por imagen , Ecocardiografía/veterinaria , Fístula/veterinaria , Fístula/diagnóstico por imagen , Endocarditis Bacteriana/veterinaria , Endocarditis Bacteriana/complicaciones , Endocarditis Bacteriana/diagnóstico por imagen , Endocarditis Bacteriana/patología , Fístula Vascular/veterinaria , Fístula Vascular/diagnóstico por imagen , Fístula Vascular/complicaciones , Masculino , Enfermedades de la Aorta/veterinaria , Enfermedades de la Aorta/diagnóstico por imagen , Enfermedades de la Aorta/patología , Enfermedades de la Aorta/complicaciones , Endocarditis/veterinaria , Endocarditis/complicaciones , Endocarditis/diagnóstico por imagen , Endocarditis/patología , Cardiopatías/veterinaria , Cardiopatías/diagnóstico por imagen , Cardiopatías/patología , Cardiopatías/etiología , Cardiopatías/complicaciones , Femenino
2.
J Vet Cardiol ; 47: 64-69, 2023 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-37247530

RESUMEN

An aclinical Havanese dog was diagnosed with a membranous restrictive ventricular septal defect. The patient was represented later in their natural history due to the development of syncope. At that time the patient was diagnosed with acquired pulmonary infundibular stenosis. Balloon dilation of the stenosis was performed successfully twice over the patient's lifetime. The patient died suddenly approximately 14 months after the second balloon dilation. A discussion regarding primary infundibular pulmonary stenosis versus causes of acquired infundibular pulmonary stenosis including anomalous muscle bundles (double chamber right ventricle), tetralogy of Fallot, and infundibular stenosis is presented.


Asunto(s)
Enfermedades de los Perros , Defectos del Tabique Interventricular , Estenosis Subvalvular Pulmonar , Tetralogía de Fallot , Perros , Animales , Estenosis Subvalvular Pulmonar/complicaciones , Estenosis Subvalvular Pulmonar/diagnóstico , Estenosis Subvalvular Pulmonar/veterinaria , Constricción Patológica/complicaciones , Constricción Patológica/veterinaria , Defectos del Tabique Interventricular/complicaciones , Defectos del Tabique Interventricular/veterinaria , Defectos del Tabique Interventricular/diagnóstico , Ventrículos Cardíacos , Cateterismo/veterinaria , Tetralogía de Fallot/complicaciones , Tetralogía de Fallot/veterinaria , Enfermedades de los Perros/diagnóstico
3.
J Vet Cardiol ; 43: 1-9, 2022 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-35870399

RESUMEN

OBJECTIVE: The aim of this paper is to evaluate owners' chronic medication adherence for management of feline cardiovascular disease in the small animal referral setting. ANIMALS, MATERIALS AND METHODS: A questionnaire-based study of owners at five multispecialty, small animal referral centers was conducted. Owners completed a written survey evaluating demographics, degree of medication adherence, and difficulties encountered for medication adherence. Owners were free to decline participation in the study. RESULTS: Fifty-four questionnaires were available for review. The most common diagnosis was hypertrophic cardiomyopathy (n = 31, 57.4%). Clopidogrel was the most cited medication that was difficult to administer consistently (n = 13, 24.0%) although twenty owners (37.0%) reported no difficulty consistently administering medications. "Taste of medication" (n = 14, 25.9%) was the most reported reason for difficulty medicating their cat, and most owners (n = 36, 66.7%) stated twice daily was the highest frequency of heart medications they feel they can consistently administer. Fifty owners (92.6%) met the criteria for medication adherence. CONCLUSIONS: Chronic medication adherence in this study population was high. Clopidogrel was the most difficult medication to consistently administer, and twice a day dosing was the highest frequency of medication administration most owners could achieve. Cardiologists should be aware of these factors when determining optimal treatment protocols for the management of cardiovascular disease in cats.


Asunto(s)
Enfermedades Cardiovasculares , Enfermedades de los Gatos , Gatos , Animales , Propiedad , Enfermedades Cardiovasculares/tratamiento farmacológico , Enfermedades Cardiovasculares/veterinaria , Clopidogrel/uso terapéutico , Encuestas y Cuestionarios , Cumplimiento de la Medicación , Derivación y Consulta , Enfermedades de los Gatos/tratamiento farmacológico
4.
J Vet Cardiol ; 32: 73-82, 2020 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-33186877

RESUMEN

Three canines were identified with aberrant drainage of the caudal vena cava to the left atrium, consistent with imperforate cor triatriatum dexter, and concurrent patent foramen ovale. All three had concurrent significant pulmonic stenosis with varying degrees of hypoplasia of the right ventricular outflow tract. Echocardiography, positive contrast studies, and angiography confirmed the diagnosis. Surgical redirection of the caudal vena cava bloodflow to the right atrium was attempted unsuccessfully in two symptomatic patients. The third patient was asymptomatic, and correction was not attempted. Possible embryologic causes and possible approaches in future cases are discussed.


Asunto(s)
Corazón Triatrial/veterinaria , Enfermedades de los Perros/diagnóstico , Foramen Oval Permeable/veterinaria , Estenosis de la Válvula Pulmonar/veterinaria , Animales , Corazón Triatrial/complicaciones , Corazón Triatrial/diagnóstico , Diagnóstico Diferencial , Enfermedades de los Perros/diagnóstico por imagen , Enfermedades de los Perros/cirugía , Perros , Ecocardiografía , Femenino , Foramen Oval Permeable/complicaciones , Foramen Oval Permeable/diagnóstico , Masculino , Estenosis de la Válvula Pulmonar/complicaciones , Estenosis de la Válvula Pulmonar/diagnóstico
5.
Am J Vet Res ; 56(11): 1534-40, 1995 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-8585669

RESUMEN

OBJECTIVE--To determine whether standard manual frequency filters in the ON and OFF settings affected P-QRS-T voltages, discover whether recorded P-QRS-T voltages vary between commercial electrocardiographs, assess effects of frequency filters on base-line artifact, and evaluate ECG frequency content by high-fidelity recordings subjected to digital filters with variable frequencies. DESIGN--Sequential 10-lead ECG were recorded in 30 cats, using 3 commercial electrocardiographs to assess effects of manual frequency filters on the P-QRS-T wave forms. Three clinically normal cats were evaluated for ECG frequency content. ANIMALS--Thirty cats (13 with hypertrophic cardiomyopathy; 4 with restrictive cardiomyopathy; 3 hyperthyroid; 1 with ventricular septal defect; 1 with aortic stenosis; and 8 with no detectable cardiovascular disease). Three additional clinically normal cats were studied for effects of frequency filters on the ECG frequency content. PROCEDURES--Ten-lead ECG were recorded on each cat by use of 3 commercial electrocardiographs sequentially. For each machine, a recording was made with manual filters ON, immediately followed by a recording with manual filters OFF. High-fidelity lead-II ECG recordings were made with filters set with their rolloff frequency at 0.1 Hz and 3.0 kHz; output voltage (0.2 mV/V) was fed to an analog-to-digital converter, then to attendant software, which sampled the signal at 6 kHz with a 12-bit sampler, and were digitally filtered at various corner frequencies. RESULTS--Voltages recorded by all 3 electrocardiographs were greatest when filters were OFF (most prominent on R- and S-wave voltages). In all recorded leads, R-wave voltage was significantly greater when filters were OFF than ON. Comparison of voltages indicated significant (P < 0.05) differences between R-wave voltages recorded in all leads with manual filters ON, but not with filters OFF. With filters ON, each electrocardiograph produced a smaller percentage of recordings with moderate to severe baseline artifact than with filters OFF. R-Wave amplitudes of high-fidelity lead-II ECG were significantly decreased with digital filters set at corner frequencies < 150 Hz. CONCLUSIONS--Significant (P < 0.05) voltage attenuation was recorded by each of the 3 commercial electrocardiographs when frequency filters were ON, compared with OFF. Comparison of waveform voltages among electrocardiographs with filters ON indicated significant variation in R-wave amplitudes in all leads. With manual filters ON, each electrocardiograph recorded a smaller percentage of recordings with baseline artifact than with filters OFF. Substantial frequency components > or = 150 Hz are present in the feline ECG waveform. Thus, filters with frequencies < 150 Hz markedly attenuate the feline R wave. CLINICAL RELEVANCE--Attenuation of feline ECG signals occurs with use of commercial electrocardiographs and varies greatly between manufacturers. This is attributable largely to internal manual frequency filters. These consequences may be important when applying standard feline reference values or when equivocal voltage measurements are recorded.


Asunto(s)
Artefactos , Enfermedades Cardiovasculares/veterinaria , Enfermedades de los Gatos , Gatos/fisiología , Electrocardiografía/instrumentación , Electrocardiografía/veterinaria , Animales , Enfermedades Cardiovasculares/fisiopatología , Electrocardiografía/métodos , Femenino , Masculino , Valores de Referencia , Especificidad de la Especie
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA