Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 104
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Swiss J Palaeontol ; 142(1): 30, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37927422

RESUMEN

The correct interpretation of fossils and their reliable taxonomic placements are fundamental for understanding the evolutionary history of biodiversity. Amber inclusions often preserve more morphological information than compression fossils, but are often partially hidden or distorted, which can impede taxonomic identification. Here, we studied four new fossil species of Darwin wasps from Baltic and Dominican amber, using micro computed tomography (micro-CT) scans and 3D reconstructions to accurately interpret and increase the availability of morphological information. We then infer their taxonomic placement in a Bayesian phylogenetic analysis by combining morphological and molecular data of extant and fossil Darwin wasps and evaluate the impact and usefulness of the additional information from micro-CT scanning. The results show that although we gained significant morphological information from micro-CT scanning, especially concerning measurements and hidden dorsal and ventral structures, this did not impact subfamily-level placement for any of the four fossils. However, micro-CT scanning improved the precision of fossil placements at the genus level, which might be key in future dating and diversification analyses. Finally, we describe the four new fossil species as Rhyssa gulliveri sp. nov. in Rhyssinae, Triclistus levii sp. nov. in Metopiinae, Firkantus freddykruegeri gen. et. sp. nov. in Pimplinae and Magnocula sarcophaga gen. et sp. nov. in Phygadeuontinae. The first two species are the first known representatives of the subfamilies Rhyssinae and Metopiinae in amber. Supplementary Information: The online version contains supplementary material available at 10.1186/s13358-023-00294-2.

2.
Sci Data ; 10(1): 510, 2023 08 03.
Artículo en Inglés | MEDLINE | ID: mdl-37537174

RESUMEN

The performance of machine learning algorithms, when used for segmenting 3D biomedical images, does not reach the level expected based on results achieved with 2D photos. This may be explained by the comparative lack of high-volume, high-quality training datasets, which require state-of-the-art imaging facilities, domain experts for annotation and large computational and personal resources. The HR-Kidney dataset presented in this work bridges this gap by providing 1.7 TB of artefact-corrected synchrotron radiation-based X-ray phase-contrast microtomography images of whole mouse kidneys and validated segmentations of 33 729 glomeruli, which corresponds to a one to two orders of magnitude increase over currently available biomedical datasets. The image sets also contain the underlying raw data, threshold- and morphology-based semi-automatic segmentations of renal vasculature and uriniferous tubules, as well as true 3D manual annotations. We therewith provide a broad basis for the scientific community to build upon and expand in the fields of image processing, data augmentation and machine learning, in particular unsupervised and semi-supervised learning investigations, as well as transfer learning and generative adversarial networks.


Asunto(s)
Algoritmos , Benchmarking , Animales , Ratones , Procesamiento de Imagen Asistido por Computador/métodos , Imagenología Tridimensional , Riñón/diagnóstico por imagen
3.
Microsc Microanal ; 29(5): 1730-1745, 2023 Sep 29.
Artículo en Inglés | MEDLINE | ID: mdl-37584515

RESUMEN

The most common form of epilepsy among adults is mesial temporal lobe epilepsy (mTLE), with seizures often originating in the hippocampus due to abnormal electrical activity. The gold standard for the histopathological analysis of mTLE is histology, which is a two-dimensional technique. To fill this gap, we propose complementary three-dimensional (3D) X-ray histology. Herein, we used synchrotron radiation-based phase-contrast microtomography with 1.6 µm-wide voxels for the post mortem visualization of tissue microstructure in an intrahippocampal-kainate mouse model for mTLE. We demonstrated that the 3D X-ray histology of unstained, unsectioned, paraffin-embedded brain hemispheres can identify hippocampal sclerosis through the loss of pyramidal neurons in the first and third regions of the Cornu ammonis as well as granule cell dispersion within the dentate gyrus. Morphology and density changes during epileptogenesis were quantified by segmentations from a deep convolutional neural network. Compared to control mice, the total dentate gyrus volume doubled and the granular layer volume quadrupled 21 days after injecting kainate. Subsequent sectioning of the same mouse brains allowed for benchmarking 3D X-ray histology against well-established histochemical and immunofluorescence stainings. Thus, 3D X-ray histology is a complementary neuroimaging tool to unlock the third dimension for the cellular-resolution histopathological analysis of mTLE.

4.
PLoS One ; 18(4): e0284562, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37079551

RESUMEN

Nephrotoxicity is an important drug safety aspect to be assessed during drug discovery and development. To study renal toxicity, in vitro cell-based assays are often used. Unfortunately, translating the results of such cell assays to vertebrates including human remains challenging. Therefore, we aim to evaluate whether zebrafish larvae (ZFL) could serve as a vertebrate screening model to detect gentamicin-induced changes of kidney glomeruli and proximal tubules. To validate the model, we compared the results of ZFL with those obtained from kidney biopsies of gentamicin-treated mice. We used transgenic zebrafish lines expressing enhanced green fluorescent proteins in the glomerulus to visualize glomerular damage. Synchrotron radiation-based computed tomography (SRµCT) is a label-free approach providing three-dimensional representations of renal structures with micrometre resolution. Clinically used gentamicin concentrations induce nephrotoxicity and affect glomerular and proximal tubular morphology. Findings were confirmed in mice and ZFL. There was a strong correlation between fluorescent signals in ZFL, SRµCT- derived descriptors of glomerular and proximal tubular morphology and the histological analysis of mouse kidney biopsies. A combination of SRµCT and confocal microscopy provides unprecedented insights into anatomical structures of the zebrafish kidney. Based on our findings, we suggest to use ZFL as a predictive vertebrate screening model to study drug-induced nephrotoxicity and to bridge the gap between cell culture-based test systems and experiments in mammals.


Asunto(s)
Enfermedades Renales , Pez Cebra , Humanos , Animales , Ratones , Gentamicinas/toxicidad , Larva , Riñón/diagnóstico por imagen , Riñón/patología , Glomérulos Renales/patología , Enfermedades Renales/patología , Mamíferos
5.
Nat Commun ; 13(1): 7222, 2022 12 06.
Artículo en Inglés | MEDLINE | ID: mdl-36473836

RESUMEN

Extrinsic and intrinsic factors impact diversity. On deep-time scales, the extrinsic impact of climate and geology are crucial, but poorly understood. Here, we use the inner ear morphology of ruminant artiodactyls to test for a deep-time correlation between a low adaptive anatomical structure and both extrinsic and intrinsic variables. We apply geometric morphometric analyses in a phylogenetic frame to X-ray computed tomographic data from 191 ruminant species. Contrasting results across ruminant clades show that neutral evolutionary processes over time may strongly influence the evolution of inner ear morphology. Extant, ecologically diversified clades increase their evolutionary rate with decreasing Cenozoic global temperatures. Evolutionary rate peaks with the colonization of new continents. Simultaneously, ecologically restricted clades show declining or unchanged rates. These results suggest that both climate and paleogeography produced heterogeneous environments, which likely facilitated Cervidae and Bovidae diversification and exemplifies the effect of extrinsic and intrinsic factors on evolution in ruminants.


Asunto(s)
Oído Interno , Geología , Filogenia , Flujo Genético
6.
J Med Imaging (Bellingham) ; 9(3): 031509, 2022 May.
Artículo en Inglés | MEDLINE | ID: mdl-36267352

RESUMEN

Purpose: The morphology of a polymer aligner, designed according to an orthodontic treatment plan, determines clinical outcomes. A fundamental element of orthodontic tooth movement with aligner treatment is the fit of the aligner's surface to the individual teeth. Gaps between the aligner and teeth do occur because current aligner fabrication is not capable of completely reproducing the complex anatomy of the individual denture. Our study aims at a quantitative three-dimensional assessment of the fit between optically transparent aligners placed on a polymeric model of the upper dental arch for two thermofoil thicknesses at preselected thermoforming temperatures. Approach: Using an intraoral scan of a subject's upper dental arch, eight models were printed using a stereolithographic system. A series of eight NaturAligners® was manufactured with a pressure molding process, using thermofoils with thicknesses of 550 and 750 µ m and preselected process temperatures between 110°C and 210°C. These aligners placed on the corresponding models were imaged by an advanced micro computed tomography system. The aligners and the models were segmented to extract the gaps and aligners' local thicknesses as a function of the processing temperature for the two foil thicknesses. Results: The results indicate that the aligners show a better fit when the foils are processed at higher temperatures. Nevertheless, processing temperatures can be kept below 150°C, as the gain becomes negligible. Thermal processing reduces the average thickness of the aligners to 60% with respect to the planar starting foil. These thickness distributions demonstrate that the aligners are generally thicker on the occlusal surfaces of molars and premolars but thinner around the incisors and buccal as well as on oral surfaces. Conclusions: Hard x-ray tomography with micrometer resolution is a powerful technique employed to localize the gaps between aligners and teeth, and it also enables film thickness measurements after thermoforming. The thicker film on the occlusal surfaces is most welcome because of aligner abrasion during wear. The NaturAligner® surfaces consist of a 25 - µ m -thin cellulose layer, and thus the microplastics released via abrasion of less than this thickness are expected to be substantially less critical than for other commercially available, optically transparent aligners.

7.
Sci Rep ; 12(1): 16139, 2022 09 27.
Artículo en Inglés | MEDLINE | ID: mdl-36168035

RESUMEN

The Helmsdorf "princely" tomb, excavated at the beginning of the twentieth century, is one of the most important archaeological discoveries dating from the Early Bronze Age in central Germany. In addition to the burial inventory, which points to an elevated social position of the deceased, a number of highly fragmented skeletal remains were preserved. Forensic anthropological investigation identified three distinctive bone defects, the surfaces of which were macromorphologically and microscopically examined in greater detail. Micro-CT analyses were also carried out. The results of all examinations suggested that the defects represented three perimortem injuries. The wound morphology was indicative of the use of a bladed weapon. The combination of injuries and their locations supported the assumption of a targeted use of force to kill. A comparison of Early Bronze Age weapons and tools with the bone lesions led to the identification of a type of weapon possibly used in the attack.


Asunto(s)
Entierro , Armas , Agresión , Arqueología/métodos , Entierro/historia , Antropología Forense
8.
J Med Imaging (Bellingham) ; 9(3): 031507, 2022 May.
Artículo en Inglés | MEDLINE | ID: mdl-35372637

RESUMEN

Purpose: Synchrotron radiation-based tomography yields microanatomical features in human and animal tissues without physical slicing. Recent advances in instrumentation have made laboratory-based phase tomography feasible. We compared the performance of three cutting-edge laboratory systems benchmarked by synchrotron radiation-based tomography for three specimens. As an additional criterion, the user-friendliness of the three microtomography systems was considered. Approach: The three tomography systems-SkyScan 2214 (Bruker-microCT, Kontich, Belgium), Exciscope prototype (Stockholm, Sweden), and Xradia 620 Versa (Zeiss, Oberkochen, Germany)-were given 36 h to measure three medically relevant specimens, namely, zebrafish larva, archaeological human tooth, and porcine nerve. The obtained datasets were registered to the benchmark synchrotron radiation-based tomography from the same specimens and selected ones to the SkyScan 1275 and phoenix nanotom m® laboratory systems to characterize development over the last decade. Results: Next-generation laboratory-based microtomography almost reached the quality achieved by synchrotron-radiation facilities with respect to spatial and density resolution, as indicated by the visualization of the medically relevant microanatomical features. The SkyScan 2214 system and the Exciscope prototype demonstrated the complementarity of phase information by imaging the eyes of the zebrafish larva. The 3 - µ m thin annual layers in the tooth cementum were identified using Xradia 620 Versa. Conclusions: SkyScan 2214 was the simplest system and was well-suited to visualizing the wealth of anatomical features in the zebrafish larva. Data from the Exciscope prototype with the high photon flux from the liquid metal source showed the spiral nature of the myelin sheaths in the porcine nerve. Xradia 620 Versa, with detector optics as typically installed for synchrotron tomography beamlines, enabled the three-dimensional visualization of the zebrafish larva with comparable quality to the synchrotron data and the annual layers in the tooth cementum.

9.
J Neurosci Methods ; 365: 109385, 2022 01 01.
Artículo en Inglés | MEDLINE | ID: mdl-34637810

RESUMEN

BACKGROUND: Fixation and embedding of post mortem brain tissue is a pre-requisite for both gold-standard conventional histology and X-ray virtual histology. This process alters the morphology and density of the brain microanatomy. NEW METHOD: To quantify these changes, we employed synchrotron radiation-based hard X-ray tomography with 3 µm voxel length to visualize the same mouse brain after fixation in 4% formalin, immersion in ethanol solutions (50%, 70%, 80%, 90%, and 100%), xylene, and finally after embedding in a paraffin block. The volumetric data were non-rigidly registered to the initial formalin-fixed state to align the microanatomy within the entire mouse brain. RESULTS: Volumetric strain fields were used to characterize local shrinkage, which was found to depend on the anatomical region and distance to external surface. X-ray contrast was altered and enhanced by preparation-induced inter-tissue density changes. The preparation step can be selected to highlight specific anatomical features. For example, fiber tract contrast is amplified in 100% ethanol. COMPARISON WITH EXISTING METHODS: Our method provides volumetric strain fields, unlike approaches based on feature-to-feature or volume measurements. Volumetric strain fields are produced by non-rigid registration, which is less labor-intensive and observer-dependent than volume change measurements based on manual segmentations. X-ray microtomography provides spatial resolution at least an order of magnitude higher than magnetic resonance microscopy, allowing for analysis of morphology and density changes within the brain's microanatomy. CONCLUSION: Our approach belongs to three-dimensional virtual histology with isotropic micrometer spatial resolution and therefore complements atlases based on a combination of magnetic resonance microscopy and optical micrographs of serial histological sections.


Asunto(s)
Encéfalo , Formaldehído , Animales , Encéfalo/diagnóstico por imagen , Ratones , Adhesión en Parafina , Sincrotrones , Microtomografía por Rayos X/métodos
10.
J Neurosci Methods ; 364: 109354, 2021 12 01.
Artículo en Inglés | MEDLINE | ID: mdl-34529981

RESUMEN

BACKGROUND: Micrometer-resolution neuroimaging with gold-standard conventional histology requires tissue fixation and embedding. The exchange of solvents for the creation of sectionable paraffin blocks modifies tissue density and generates non-uniform brain shrinkage. NEW METHOD: We employed synchrotron radiation-based X-ray microtomography for slicing- and label-free virtual histology of the mouse brain at different stages of the standard preparation protocol from formalin fixation via ascending ethanol solutions and xylene to paraffin embedding. Segmentation of anatomical regions allowed us to quantify non-uniform tissue shrinkage. Global and local changes in X-ray absorption gave insight into contrast enhancement for virtual histology. RESULTS: The volume of the entire mouse brain was 60%, 56%, and 40% of that in formalin for, respectively, 100% ethanol, xylene, and paraffin. The volume changes of anatomical regions such as the hippocampus, anterior commissure, and ventricles differ from the global volume change. X-ray absorption of the full brain decreased, while local absorption differences increased, resulting in enhanced contrast for virtual histology. These trends were also observed with laboratory microtomography measurements. COMPARISON WITH EXISTING METHODS: Microtomography provided sub-10 µm spatial resolution with sufficient density resolution to resolve anatomical structures at each step of the embedding protocol. The spatial resolution of conventional computed tomography and magnetic resonance microscopy is an order of magnitude lower and both do not match the contrast of microtomography over the entire embedding protocol. Unlike feature-to-feature or total volume measurements, our approach allows for calculation of volume change based on segmentation. CONCLUSION: We present isotropic micrometer-resolution imaging to quantify morphology and composition changes in a mouse brain during the standard histological preparation. The proposed method can be employed to identify the most appropriate embedding medium for anatomical feature visualization, to reveal the basis for the dramatic X-ray contrast enhancement observed in numerous embedded tissues, and to quantify morphological changes during tissue fixation and embedding.


Asunto(s)
Formaldehído , Imagenología Tridimensional , Animales , Encéfalo/diagnóstico por imagen , Ratones , Adhesión en Parafina , Microtomografía por Rayos X
11.
Biomedicines ; 9(8)2021 Aug 03.
Artículo en Inglés | MEDLINE | ID: mdl-34440156

RESUMEN

One major limitation for the vascularization of bone substitutes used for filling is the presence of mineral blocks. The newly-formed blood vessels are stopped or have to circumvent the mineral blocks, resulting in inefficient delivery of oxygen and nutrients to the implant. This leads to necrosis within the implant and to poor engraftment of the bone substitute. The aim of the present study is to provide a bone substitute currently used in the clinic with suitably guided vascularization properties. This therapeutic hybrid bone filling, containing a mineral and a polymeric component, is fortified with pro-angiogenic smart nano-therapeutics that allow the release of angiogenic molecules. Our data showed that the improved vasculature within the implant promoted new bone formation and that the newly-formed bone swapped the mineral blocks of the bone substitutes much more efficiently than in non-functionalized bone substitutes. Therefore, we demonstrated that our therapeutic bone substitute is an advanced therapeutical medicinal product, with great potential to recuperate and guide vascularization that is stopped by mineral blocks, and can improve the regeneration of critical-sized bone defects. We have also elucidated the mechanism to understand how the newly-formed vessels can no longer encounter mineral blocks and pursue their course of vasculature, giving our advanced therapeutical bone filling great potential to be used in many applications, by combining filling and nano-regenerative medicine that currently fall short because of problems related to the lack of oxygen and nutrients.

12.
Nanomaterials (Basel) ; 11(5)2021 May 17.
Artículo en Inglés | MEDLINE | ID: mdl-34067681

RESUMEN

Obtaining a functional tooth is the ultimate goal of tooth engineering. However, the implantation of bioengineered teeth in the jawbone of adult animals never allows for spontaneous eruption due mainly to ankylosis within the bone crypt. The objective of this study was to develop an innovative approach allowing eruption of implanted bioengineered teeth through the isolation of the germ from the bone crypt using a polycaprolactone membrane (PCL). The germs of the first lower molars were harvested on the 14th day of embryonic development, cultured in vitro, and then implanted in the recipient site drilled in the maxillary bone of adult mice. To prevent the ankylosis of the dental germ, a PCL membrane synthesized by electrospinning was placed between the germ and the bone. After 10 weeks of follow-up, microtomography, and histology of the implantation site were performed. In control mice where germs were directly placed in contact with the bone, a spontaneous eruption of bioengineered teeth was only observed in 3.3% of the cases versus 19.2% in the test group where PCL biomembrane was used as a barrier (p < 0.1). This preliminary study is the first to describe an innovative method allowing the eruption of bioengineered tooth implanted directly in the jawbone of mice. This new approach is a hope for the field of tooth regeneration, especially in children with oligodontia in whom titanium implants are not an optimal solution.

13.
J Med Imaging (Bellingham) ; 8(3): 035501, 2021 May.
Artículo en Inglés | MEDLINE | ID: mdl-34056032

RESUMEN

Purpose: In dental offices, there is a trend replacing conventional silicone impressions and plaster cast models by imaging data of intraoral scanners to map the denture and surrounding tissues. The aim of the study is the analysis of the accuracy of selected commercially available scanners. The accuracy is considered as the main drawback in comparison to the conventional approach. Approach: We evaluated the reproduction performance of five optical scanners by a direct comparison with high-resolution hard x-ray computed tomography data, all obtained from a polyetheretherketone model with similarity to a full-arch upper jaw. Results: Using the software GOM Inspect (GOM GmbH, Braunschweig, Germany), we could classify the intraoral scanners into two groups. The more accurate instruments gave rise to the following precision values: 35 µ m (TRIOS® 3, 3shape, Copenhagen, Denmark), 43 µ m (CS 3600, Carestream, Atlanta, Georgia), and 46 µ m (3M™ True Definition Scanner, 3M ESPE, St. Paul, Minnesota). The less precise systems yielded 93 µ m (Medit i500, Medit corp., Seongbuk-gu, South Korea) and 97 µ m (Emerald™, Planmeca Oy, Helsinki, Finland). Conclusions: The selected scanners are suitable for single crowns, small bridges, and separate quadrants prostheses. Scanners based on triangulation are hardly appropriate for full-arch prostheses. Besides precision, however, the choice of the scanner depends on scanning time, intraoral-camera size, and the user's learning curve. The developed protocol, which includes three-dimensional (3D) imaging and advanced computational tools for the registration with the design data, will be increasingly used in geometrical metrology by nondestructive procedures to perform dimensional measurements with micrometer precision and is capable for detailed 3D geometrical models reconstruction.

14.
Swiss Dent J ; 131(7-8)2021 Jan 29.
Artículo en Inglés | MEDLINE | ID: mdl-33512791

RESUMEN

The purpose of this study was to investigate the ability of dentists to remove composite fillings from endodontic access cavities using illumination from a conventional light source (CLS) versus the fluorescence-aided identification technique (FIT) in terms of completeness, selectivity and treatment duration. Therefore, two independent operators removed composite resin from six sets of root-filled incisors in a maxillary model under simulated clinical conditions using the CLS or FIT method (twelve teeth per operator and technique). The duration of treatment was recorded and before-after micro-CT scans were superimposed for volumetric assessment of treatment completeness and selectivity. Statistical significance was determined by t-testing and two-way ANOVA for operator comparison. Overall, there was no significant difference between FIT and CLS in terms of volume, height and area of composite residues (p=0.98 / p=0.75 / p=0.64) and regarding hard tissue loss in terms of volume, depth and area (p= 0.93 / p= 0.70 / p= 0.14). However, there was a significant difference between the two groups regarding treatment time (FIT= 428s, CLS=523s; p=0.023). Significant differences between operators regardless of method were found for volume, height and area of composite residues (p<0.05) and also for defect area (p=0.01) and time (p<0.001). Significant differences between operators including the method was only found for height of composites (p=0.037). It can be concluded, that composite remnants and tooth structure losses may occur after reentry of root-filled teeth regardless of the illumination method (conventional vs. fluorescence-aided) and operator, but preparation was less time-consuming with FIT.

15.
Nanomaterials (Basel) ; 10(9)2020 Sep 08.
Artículo en Inglés | MEDLINE | ID: mdl-32911737

RESUMEN

Oral diseases have an impact on the general condition and quality of life of patients. After a dento-alveolar trauma, a tooth extraction, or, in the case of some genetic skeletal diseases, a maxillary bone defect, can be observed, leading to the impossibility of placing a dental implant for the restoration of masticatory function. Recently, bone neoformation was demonstrated after in vivo implantation of polycaprolactone (PCL) biomembranes functionalized with bone morphogenic protein 2 (BMP-2) and ibuprofen in a mouse maxillary bone lesion. In the present study, human bone marrow derived mesenchymal stem cells (hBM-MSCs) were added on BMP-2 functionalized PCL biomembranes and implanted in a maxillary bone lesion. Viability of hBM-MSCs on the biomembranes has been observed using the "LIVE/DEAD" viability test and scanning electron microscopy (SEM). Maxillary bone regeneration was observed for periods ranging from 90 to 150 days after implantation. Various imaging methods (histology, micro-CT) have demonstrated bone remodeling and filling of the lesion by neoformed bone tissue. The presence of mesenchymal stem cells and BMP-2 allows the acceleration of the bone remodeling process. These results are encouraging for the effectiveness and the clinical use of this new technology combining growth factors and mesenchymal stem cells derived from bone marrow in a bioresorbable membrane.

16.
Microsc Microanal ; 26(4): 731-740, 2020 08.
Artículo en Inglés | MEDLINE | ID: mdl-32627730

RESUMEN

Concurrent three-dimensional imaging of the renal vascular and tubular systems on the whole-kidney scale with capillary level resolution is labor-intensive and technically difficult. Approaches based on vascular corrosion casting and X-ray micro computed tomography (µCT), for example, suffer from vascular filling artifacts and necessitate imaging with an additional modality to acquire tubules. In this work, we report on a new sample preparation, image acquisition, and quantification protocol for simultaneous vascular and tubular µCT imaging of whole, uncorroded mouse kidneys. The protocol consists of vascular perfusion with the water-soluble, aldehyde-fixable, polymeric X-ray contrast agent XlinCA, followed by laboratory-source µCT imaging and structural analysis using the freely available Fiji/ImageJ software. We achieved consistent filling of the entire capillary bed and staining of the tubules in the cortex and outer medulla. After imaging at isotropic voxel sizes of 3.3 and 4.4 µm, we segmented vascular and tubular systems and quantified luminal volumes, surface areas, diffusion distances, and vessel path lengths. This protocol permits the analysis of vascular and tubular parameters with higher reliability than vascular corrosion casting, less labor than serial sectioning and leaves tissue intact for subsequent histological examination with light and electron microscopy.


Asunto(s)
Túbulos Renales/irrigación sanguínea , Túbulos Renales/diagnóstico por imagen , Modelos Anatómicos , Microtomografía por Rayos X/métodos , Animales , Medios de Contraste/farmacología , Femenino , Interpretación de Imagen Asistida por Computador/métodos , Imagenología Tridimensional/métodos , Riñón/irrigación sanguínea , Riñón/diagnóstico por imagen , Pruebas de Función Renal , Ratones , Ratones Endogámicos C57BL
17.
J Biomech ; 106: 109833, 2020 06 09.
Artículo en Inglés | MEDLINE | ID: mdl-32517994

RESUMEN

Wind braked rowing ergometers are used worldwide for training and testing of rowers, but data on validity and reliability of the calculated mechanical power output are scarce. Studies published so far are based on data generated by human rowers, inevitably adding biological variability without any option to clamp particular variables like stroke structure or force. To this end, we developed a test rig for rowing ergometers aiming to generate valid and reliable stroke structures (i.e. force-displacement curves). Briefly, the rig consists out of a frame connected to the ergometer. The handlebar of the rowing ergometer is attached to a sledge that can be displaced on a linear drive by a motor that is controlled by torque curves which are derived from elite rowers. A load cell between handlebar and chain and an incremental linear transducer allow criterion measures of force and distance of displacement to calculate mechanical power output. To evaluate the validity of the machine generated force-displacement curves, three different stroke structures were compared to the respective human reference curves. To evaluate reliability, series of 50 consecutive strokes were performed for 10 times. Validity of the curves was indicated by small differences in stroke-force, -distance, and -work (≤ |-7.8|%) between machine generated and human generated curves. Mean power output of the test series was 445 ± 1 W with a coefficient of variation of 0.53% between series. Hence, the test rig allows to generate valid and reliable rowing strokes on wind braked rowing ergometers.


Asunto(s)
Deportes Acuáticos , Viento , Ergometría , Humanos , Reproducibilidad de los Resultados
18.
Small ; 16(31): e2000746, 2020 08.
Artículo en Inglés | MEDLINE | ID: mdl-32567135

RESUMEN

Metal-based nanoparticles are clinically used for diagnostic and therapeutic applications. After parenteral administration, they will distribute throughout different organs. Quantification of their distribution within tissues in the 3D space, however, remains a challenge owing to the small particle diameter. In this study, synchrotron radiation-based hard X-ray tomography (SRµCT) in absorption and phase contrast modes is evaluated for the localization of superparamagnetic iron oxide nanoparticles (SPIONs) in soft tissues based on their electron density and X-ray attenuation. Biodistribution of SPIONs is studied using zebrafish embryos as a vertebrate screening model. This label-free approach gives rise to an isotropic, 3D, direct space visualization of the entire 2.5 mm-long animal with a spatial resolution of around 2 µm. High resolution image stacks are available on a dedicated internet page (http://zebrafish.pharma-te.ch). X-ray tomography is combined with physico-chemical characterization and cellular uptake studies to confirm the safety and effectiveness of protective SPION coatings. It is demonstrated that SRµCT provides unprecedented insights into the zebrafish embryo anatomy and tissue distribution of label-free metal oxide nanoparticles.


Asunto(s)
Nanopartículas de Magnetita , Nanopartículas del Metal , Animales , Óxidos , Distribución Tisular , Tomografía Computarizada por Rayos X , Pez Cebra
19.
Int J Oral Sci ; 12(1): 5, 2020 02 06.
Artículo en Inglés | MEDLINE | ID: mdl-32024813

RESUMEN

Rheumatoid arthritis (RA) is an autoimmune disease affecting 1% of the world population and is characterized by chronic inflammation of the joints sometimes accompanied by extra-articular manifestations. K/BxN mice, originally described in 1996 as a model of polyarthritis, exhibit knee joint alterations. The aim of this study was to describe temporomandibular joint (TMJ) inflammation and damage in these mice. We used relevant imaging modalities, such as micro-magnetic resonance imaging (µMRI) and micro-computed tomography (µCT), as well as histology and immunofluorescence techniques to detect TMJ alterations in this mouse model. Histology and immunofluorescence for Col-I, Col-II, and aggrecan showed cartilage damage in the TMJ of K/BxN animals, which was also evidenced by µCT but was less pronounced than that seen in the knee joints. µMRI observations suggested an increased volume of the upper articular cavity, an indicator of an inflammatory process. Fibroblast-like synoviocytes (FLSs) isolated from the TMJ of K/BxN mice secreted inflammatory cytokines (IL-6 and IL-1ß) and expressed degradative mediators such as matrix metalloproteinases (MMPs). K/BxN mice represent an attractive model for describing and investigating spontaneous damage to the TMJ, a painful disorder in humans with an etiology that is still poorly understood.


Asunto(s)
Artritis Experimental/patología , Artritis Reumatoide/patología , Huesos/diagnóstico por imagen , Articulación Temporomandibular/diagnóstico por imagen , Articulación Temporomandibular/lesiones , Microtomografía por Rayos X/métodos , Animales , Artritis Experimental/inmunología , Artritis Reumatoide/inmunología , Huesos/metabolismo , Huesos/patología , Modelos Animales de Enfermedad , Humanos , Imagen por Resonancia Magnética , Metaloproteinasa 8 de la Matriz/inmunología , Ratones , Ratones Transgénicos , Articulación Temporomandibular/metabolismo , Tomografía Computarizada por Rayos X
20.
Sci Rep ; 10(1): 2131, 2020 02 07.
Artículo en Inglés | MEDLINE | ID: mdl-32034181

RESUMEN

Violence seems deeply rooted in human nature and an endemic potential for such is today frequently associated with differing ethnic, religious or socio-economic backgrounds. Ethnic nepotism is believed to be one of the main causes of inter-group violence in multi-ethnic societies. At the site of Els Trocs in the Spanish Pyrenees, rivalling groups of either migrating early farmers or farmers and indigenous hunter-gatherers collided violently around 5300 BCE. This clash apparently resulted in a massacre of the Els Trocs farmers. The overkill reaction was possibly triggered by xenophobia or massive disputes over resources or privileges. In the present, violence and xenophobia are controlled and sanctioned through social codes of conduct and institutions. So that, rather than representing an insurmountable evolutionary inheritance, violence and ethnic nepotism can be overcome and a sustainable future achieved through mutual respect, tolerance and openness to multi-ethnic societies.


Asunto(s)
Arqueología , Agricultores , Adulto , Agricultura , Niño , Preescolar , Etnicidad , Femenino , Migración Humana , Humanos , Masculino , Persona de Mediana Edad , España , Violencia , Xenofobia
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...