Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 23
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Diagnostics (Basel) ; 14(5)2024 Feb 26.
Artículo en Inglés | MEDLINE | ID: mdl-38472970

RESUMEN

BACKGROUND: Trabeculae in vertebral bodies are unequally distributed within the cervical spine (CS), the thoracic spine (TS), and lumbar spine (LS). Such structures are also unequally distributed within the individual vertebrae. Exact knowledge of the microstructure of these entities could impact our understanding and treatment of fractures caused by osteoporosis and possibly improve surgical approaches. Appropriate investigations could help clarify the pathomechanisms of different forms of osteoporotic vertebral fractures, as well as different changes in morphological findings like the trabecular bone score (TBS). In the present study, we applied punctures to the craniocaudal and ventrocaudal directions and obtained cylinders of cancellous bone from the central portions and marginal regions of cervical vertebrae 5 and 6, thoracic vertebrae 8 and 12, and lumbar vertebrae 1 and 3. We systematically analyzed these samples to determine the bone volume fraction, trabecular thickness, separation, connectivity density, degree of anisotropy, and structure model index. METHODS: Using an 8-gauge Jamshidi needle, we obtained samples from three quadrants (Q I: right margin; Q II: central; Q III: left margin) in the frontal and transverse plane and prepared these samples with a moist cloth in a 1.5 mL Eppendorf reaction vessel. The investigations were performed on a micro-CT device (SKYSCAN 1172, RJL Micro & Analytic Company, Karlsdorf-Neuthard, Germany). All collected data were analyzed using the statistical software package SPSS (version 24.0, IBM Corp., Armonk, NY, USA). Student's t test, the Wilcoxon-Mann-Whitney test, the Chi-squared test, and univariate analysis were used for between-group comparisons. The selection of the test depended on the number of investigated groups and the result of the Shapiro-Wilk test of normal distribution. In the case of statistically significant results, a post hoc LSD test was performed. RESULTS: In total, we obtained 360 bone samples from 20 body donors. The craniocaudal puncture yielded data of similar magnitudes for all investigated parameters in all three quadrants, with the highest values observed in the CS. Comparisons of the ventrodorsal and craniocaudal microstructure revealed a significantly lower trabecular density and a significantly higher degree of anisotropy in the craniocaudal direction. CONCLUSIONS: The results presented different distributions and behaviors of trabecular density, with lower density in the mid-vertebral region over the entire breadth of the vertebrae. Reduced trabecular density caused a higher degree of anisotropy and was, therefore, associated with a lower capacity to sustain biomechanical loads. Fractures in fish vertebrae were easily explained by this phenomenon. The different changes in these structures could be responsible, in part, for the changes in the TBS determined using dual-energy X-ray absorptiometry. These results confirm the clinical relevance of the TBS.

2.
J Orthop ; 49: 48-55, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38075457

RESUMEN

Background: Due to the absence of suitable diagnostic procedures, osteoporosis (OP) is frequently detected late or not at all. Many elderly persons undergo computed tomographies (CT). The routine determination of Hounsfield units (HU) in bone as a part of these examinations could close a gap here. Methods: Spines were extracted from 22 body donors, fixed in a PVC water phantom, and subjected to a high-resolution CT investigation. Cancellous bone was examined and its bone mineral density measured in HU from cervical vertebra 3 to lumbar vertebra 5 (484 vertebral bodies). On sagittal sections, a circular and a rectangular region of interest (ROI) were defined in mid-vertebral cancellous bone, positioned manually, and the measurements were performed by three experienced radiologists. Bone mineral density (BMD), measured in mg/cm3, was used to determine the presence of OP. Results: All of the spines were osteoporotic. In the presence of a BMD below 60 mg/cm3 and HU values below 63.36 in lumbar vertebrae, there were significantly more vertebral body fractures in the thoracic and thoracolumbar spine. No difference was observed between the manually positioned circular and rectangular regions of interest (ROI) on the sagittal CT section (p > 0.05). Similar HU counts were obtained by the individual examiners (p > 0.05). The following formula was used to determine QCT values on a non-contrasted CT of the spine: QCT = 0.6 × HU + 13.7. Conclusions: Measurement of the density of cancellous bone in HU can be used to determine BMD for estimating demineralization. Quantitative BMD values in mg/cm3, which can be calculated from the HU data, concur well with QCT values.

3.
Bioengineering (Basel) ; 10(6)2023 Jun 20.
Artículo en Inglés | MEDLINE | ID: mdl-37370674

RESUMEN

Chronic otitis media is often connected to Eustachian tube dysfunction. As successful treatment cannot be guaranteed with the currently available options, the aim is to develop a stent for the Eustachian tube (ET). Over the course of this development, different prototypes were generated and tested in ex vivo experiments. Four different prototypes of an ET stent and one commercially available coronary stent were implanted in the ET of seven human donor bodies. The position of the stents was verified by cone beam CT. The implanted ETs were harvested, embedded in resin and ground at 200 µm steps. Resulting images of the single steps were used to generate 3D models. The 3D models were then evaluated regarding position of the stent in the ET, its diameters, amount of squeezing, orientation of the axes and other parameters. Virtual reconstruction of the implanted ET was successful in all cases and revealed one incorrect stent placement. The cross-section increased for all metal stents in direction from the isthmus towards the pharyngeal orifice of the ET. Depending on the individual design of the metal stents (open or closed design), the shape varied also between different positions along a single stent. In contrast, the cross-section area and shape remained constant along the polymeric prototype. With the current investigation, insight into the behavior of different prototypes of ET stents was gained, which can help in defining the specifications for the intended ET stent.

4.
Anat Sci Int ; 98(4): 566-579, 2023 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-37093524

RESUMEN

Trabecular structures in vertebral bodies are unequally distributed in the cervical, thoracic and lumbar spine, and also within individual vertebrae. Knowledge of the microstructure of these entities could influence our comprehension and treatment of osteoporotic fractures, and even surgical procedures. Appropriate investigations may clarify the pathomechanisms of various osteoporotic fractures (fish, wedge-shaped, and flat vertebrae). We obtained three cancellous bone cylinders from the centers and margins of cervical vertebra 3 to lumbar vertebra 5, and investigated these in regard of bone volume fraction, trabecular thickness, separation, trabecular number, trabecular bone pattern factor, connectivity density, and degree of anisotropy. Using a Jamshidi needle®, we obtained samples from three quadrants (QI: right-sided edge, QII: central, QIII: left-sided edge) of 242 prepared vertebrae, and investigated these on a micro-CT device. In all, 726 bone samples were taken from eleven body donors. Bone volume fraction, trabecular thickness, and the degree of anisotropy were significantly lower in QII than in QI and QIII. Trabecular pattern factor, however, was significantly higher in QII than in QI and QIII. The results helped to explain fish vertebrae. Wedge fractures and flat vertebrae are most likely caused by the complex destruction of trabecular and cortical structures. The higher bone volume fraction in the cervical spine compared to the thoracic and lumbar spine accounts for the small number of fractures in the cervical spine. The marked trabecular pattern factor in the center of thoracic and lumbar vertebrae could be a reason for the surgeon to use different screw designs for individual vertebrae.


Asunto(s)
Fracturas Osteoporóticas , Animales , Vértebras Lumbares , Vértebras Cervicales , Microtomografía por Rayos X , Región Lumbosacra , Densidad Ósea
5.
Ann Anat ; 246: 152022, 2023 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-36403851

RESUMEN

BACKGROUND: Knowledge of the histomorphometric structure of the vertebral body and factors influencing the structure is essential for a fundamental understanding of osteoporosis and osteoporotic fractures. The present study is focused on osteocyte density - a parameter seldom investigated so far - and trabecular width as well as bone area over tissue area in human vertebral bodies. METHODS: Ninety-two vertebral body specimens (C5, C6, Th8, Th12, L1, L2) from 12 males and seven females were studied (Ethics Application Number A 2017-0072). The prepared vertebral specimens were extracted from the ventral aspect with a Jamshidi needle®. The punches were decalcified and subsequently H&E stained. Using the Fiji/Image J program (version 1.53 f, Wayne Resband, National Institute of Mental Health, USA), osteocyte numbers were counted per calcified bone surface, and the trabecular width and bone area of trabecular bone were measured. The collected data were analyzed using the statistical software package SPSS, version 23.0 (SPSS Inc., Chicago, USA). Pearson's correlation coefficient was used for correlation analyses. Multiple linear regression analyses were also performed. RESULTS: Osteocyte density did not differ significantly in comparisons based on gender and age (≤65 years; ≥66 years). Men had wider trabeculae (p < 0.001) and a higher bone area over tissue area (BA/TA, %) (p = 0.025) than women. Individuals over 65 years of age had thinner trabeculae (p < 0.001) and a smaller BA/TA (%) (p < 0.001) than younger individuals. Multiple linear regression analyses were performed to determine the influence of 'gender' and 'age' on trabecular width and bone area over tissue area. The R² was 0.388 for trabecular width and 0.227 for BA/TA (%). Per year of life, trabecular width decreases by 0.368 µm (ß < 0.001) and BA/TA (%) by 0.001% (ß = 0.001). Men have on average 8.2 µm wider trabeculae than women (ß = 0.035). A negative correlation (r = -0.275) was observed between trabecular width and osteocyte density. The wider the trabeculae, the fewer osteocytes per mm² (p = 0.008). CONCLUSIONS: Surprisingly, we found no difference in osteocyte density with reference to age or gender. However, we did register significant age- and gender-related differences in bone area over tissue area and trabecular thickness. The age-related differences were more pronounced, implying that age-dependent loss of bone structure may be more important than differences between genders.


Asunto(s)
Osteocitos , Osteoporosis , Humanos , Femenino , Masculino , Anciano , Cuerpo Vertebral , Columna Vertebral , Huesos , Densidad Ósea , Vértebras Lumbares
6.
Orthopadie (Heidelb) ; 51(7): 547-555, 2022 Jul.
Artículo en Alemán | MEDLINE | ID: mdl-35776151

RESUMEN

BACKGROUND: The risk of osteoporotic insufficiency fractures (Fx) at the axial skeleton increases with decreasing bone density, with an accumulation in the thoracic and thoracolumbar regions. To better understand the differential distribution of Fx along the spine, morphological and osteodensitometric studies were performed by computed tomography (CT) in the various spine sections. In addition, we aimed to clarify whether Hounsfield units (HU) found on CT examinations from other indications correlate with bone density and could be grounds for osteologic diagnosis. MATERIAL AND METHODS: The entire spines of 26 body donors were fixed in a Plexiglas water phantom and analyzed by high-resolution spiral CT. In addition, CT morphological cancellous bone density was measured in HU from C3 to S2 (624 vertebral bodies). Bone mineral density (BMD, mg/ml) was calculated and used to estimate osteoporosis (OPO). RESULTS: OPO was present in all spines. Significantly increased sintering fractures were found in the thoracic and thoracolumbar regions when BMD was below 60 mg/ml. Fx in the cervical spine area were not found overall. Cancellous bone density was significantly higher in the cervical (median 188.6 HU) than in the lumbar (median 63.6 HU) and sacral (median 25.5 HU) spine. DISCUSSION: BMD loss of vertebral body cancellous bone leads to an increased risk of Fx, which is also found in the cadaver spines. However, an apparent threshold for the occurrence of sintering fractures is not undercut in the cervical region. Finding a threshold for HU would be relevant to clinical practice.


Asunto(s)
Fracturas por Estrés , Fracturas Osteoporóticas , Densidad Ósea , Hueso Esponjoso/diagnóstico por imagen , Vértebras Cervicales , Humanos , Vértebras Lumbares/diagnóstico por imagen , Fracturas Osteoporóticas/diagnóstico por imagen
7.
J Orthop Surg Res ; 17(1): 228, 2022 Apr 11.
Artículo en Inglés | MEDLINE | ID: mdl-35410435

RESUMEN

BACKGROUND: The purpose of the study was to investigate associations between biomechanical resilience (failure load, failure strength) and the microarchitecture of cancellous bone in the vertebrae of human cadavers with low bone density with or without vertebral fractures (VFx). METHODS: Spines were removed from 13 body donors (approval no. A 2017-0072) and analyzed in regard to bone mineral density (BMD), Hounsfield units (HU), and fracture count (Fx) with the aid of high-resolution CT images. This was followed by the puncture of cancellous bone in the vertebral bodies of C2 to L5 using a Jamshidi™ needle. The following parameters were determined on the micro-CT images: bone volume fraction (BVF), trabecular thickness (Tb.Th), trabecular separation (Tb.Sp), degree of anisotropy (DA), trabecular number (Tb.N), trabecular pattern factor (Tb.Pf), and connectivity density (Conn.D). The axial load behavior of 104 vertebral specimens (C5, C6, T7, T8, T9, T12, L1, L3) was investigated with a servohydraulic testing machine. RESULTS: Individuals with more than 2 fractures had a significantly lower trabecular pattern factor (Tb.Pf), which also proved to be an important factor for a reduced failure load in the regression analysis with differences between the parts of the spine. The failure load (FL) and endplate sizes of normal vertebrae increased with progression in the craniocaudal direction, while the HU was reduced. Failure strength (FS) was significantly greater in the cervical spine than in the thoracic or lumbar spine (p < 0.001), independent of sex. BVF, Tb.Th, Tb.N, and Conn.D were significantly higher in the cervical spine than in the other spinal segments. In contrast, Tb.Sp and Tb.Pf were lowest in the cervical spine. BVF was correlated with FL (r = 0.600, p = 0.030) and FS (r = 0.763, p = 0.002). Microarchitectural changes were also detectable in the cervical spine at lower densities. CONCLUSIONS: Due to the unique microarchitecture of the cervical vertebrae, fractures occur much later in this region than they do in the thoracic or lumbar spine. Trial registration Approval no. A 2017-0072.


Asunto(s)
Osteoporosis , Punción Espinal , Densidad Ósea , Vértebras Cervicales , Humanos , Vértebras Lumbares/diagnóstico por imagen , Osteoporosis/diagnóstico por imagen , Vértebras Torácicas/diagnóstico por imagen , Microtomografía por Rayos X
9.
Eur Radiol ; 32(2): 1014-1023, 2022 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-34463797

RESUMEN

OBJECTIVES: Knowledge about cochlear duct length (CDL) may assist electrode choice in cochlear implantation (CI). However, no gold standard for clinical applicable estimation of CDL exists. The aim of this study is (1) to determine the most reliable radiological imaging method and imaging processing software for measuring CDL from clinical routine imaging and (2) to accurately predict the insertion depth of the CI electrode. METHODS: Twenty human temporal bones were examined using different sectional imaging techniques (high-resolution computed tomography [HRCT] and cone beam computed tomography [CBCT]). CDL was measured using three methods: length estimation using (1) a dedicated preclinical 3D reconstruction software, (2) the established A-value method, and (3) a clinically approved otosurgical planning software. Temporal bones were implanted with a 31.5-mm CI electrode and measurements were compared to a reference based on the CI electrode insertion angle measured by radiographs in Stenvers projection (CDLreference). RESULTS: A mean cochlear coverage of 74% (SD 7.4%) was found. The CDLreference showed significant differences to each other method (p < 0.001). The strongest correlation to the CDLreference was found for the otosurgical planning software-based method obtained from HRCT (CDLSW-HRCT; r = 0.87, p < 0.001) and from CBCT (CDLSW-CBCT; r = 0.76, p < 0.001). Overall, CDL was underestimated by each applied method. The inter-rater reliability was fair for the CDL estimation based on 3D reconstruction from CBCT (CDL3D-CBCT; intra-class correlation coefficient [ICC] = 0.43), good for CDL estimation based on 3D reconstruction from HRCT (CDL3D-HRCT; ICC = 0.71), poor for CDL estimation based on the A-value method from HRCT (CDLA-HRCT; ICC = 0.29), and excellent for CDL estimation based on the A-value method from CBCT (CDLA-CBCT; ICC = 0.87) as well as for the CDLSW-HRCT (ICC = 0.94), CDLSW-CBCT (ICC = 0.94) and CDLreference (ICC = 0.87). CONCLUSIONS: All approaches would have led to an electrode choice of rather too short electrodes. Concerning treatment decisions based on CDL measurements, the otosurgical planning software-based method has to be recommended. The best inter-rater reliability was found for CDLA-CBCT, for CDLSW-HRCT, for CDLSW-CBCT, and for CDLreference. KEY POINTS: • Clinically applicable calculations using high-resolution CT and cone beam CT underestimate the cochlear size. • Ten percent of cochlear duct length need to be added to current calculations in order to predict the postoperative CI electrode position. • The clinically approved otosurgical planning software-based method software is the most suitable to estimate the cochlear duct length and shows an excellent inter-rater reliability.


Asunto(s)
Implantación Coclear , Implantes Cocleares , Cóclea/diagnóstico por imagen , Conducto Coclear/cirugía , Tomografía Computarizada de Haz Cónico , Electrodos Implantados , Humanos , Reproducibilidad de los Resultados , Hueso Temporal/diagnóstico por imagen , Tomografía Computarizada por Rayos X
10.
Z Orthop Unfall ; 160(6): 657-669, 2022 12.
Artículo en Inglés, Alemán | MEDLINE | ID: mdl-34937100

RESUMEN

INTRODUCTION: The human bone structure changes with an increase in age. Both material and structural properties affect bone strength. Despite the ageing of society, however, hardly any data are available on these parameters for elderly individuals. Therefore, in the present study, cancellous bone cylinders were taken from the center of each vertebral body (C3 to L5) and examined with regard to bone volume fraction, trabecular thickness, separation, number of trabeculae, cross-linking, connectivity density and degree of anisotropy. MATERIAL AND METHODS: Samples were obtained from 440 body donors using a Jamshidi needle and analysed using microcomputed tomography. Existing deformities, fractures and bone mineral density of each vertebra were recorded by quantitative computed tomography. RESULTS: With regard to the microcomputed tomography parameters, statistically significant differences were found between the different sections of the vertebrae: the trabeculae of the cervical vertebrae were significantly thicker and more closely spaced than in the thoracic and lumbar vertebrae. The bone volume fraction was significantly higher in this spinal segment, as was the connection density and the number of trabeculae and cross-links. In addition, the degree of anisotropy was significantly lower in the cervical vertebrae than in the other spinal segments. With regard to quantitative computed tomography, there was a significantly higher bone mineral density in the cervical vertebrae. CONCLUSION: Even with osteoporosis, cervical vertebrae fracture significantly later than thoracic and lumbar vertebrae due to their unique microarchitecture and higher density. Thus, the cervical vertebrae has specific properties.


Asunto(s)
Fracturas por Estrés , Osteoporosis , Fracturas de la Columna Vertebral , Humanos , Anciano , Microtomografía por Rayos X , Osteoporosis/diagnóstico por imagen , Vértebras Lumbares/diagnóstico por imagen , Vértebras Cervicales/diagnóstico por imagen , Fracturas de la Columna Vertebral/diagnóstico por imagen
11.
Local Reg Anesth ; 14: 133-138, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34675651

RESUMEN

PURPOSE: Sensory innervation in the carotid triangle involves the cervical plexus, cranial nerves, and the sympathetic trunk. This innervation also applies to skin incision, including various anatomical structures with potentially different innervation, such as the skin (dermatomes), the platysma (myotomes), and the superficial layer of the cervical fascia (fasciotomes), as well as retromandibular retractor insertion (co-innervation: V, VII). The aim of this anatomical study was to develop an injection technique for carotid endarterectomies to additionally block anastomoses between the transverse cervical nerve (TCN), the cervical branch VII (CB VII), and the marginal mandibular branch VII (MMB VII). These anastomoses are also termed superficial cervical ansa (SCA). MATERIALS AND METHODS: Preparations (n=16) were performed on unembalmed donor cadavers (n=8). Subplatysmal injections (each using 5 mL of Alcian blue) were performed cranially within the carotid triangle between the anterior margin of the sternocleidomastoid muscle and the submandibular gland. RESULTS: Anastomoses between the TCN, CB VII, and MMB VII were stained in all preparations (n=16). CONCLUSION: This anatomical study presents an ultrasound-guided subplatysmal SCA block to optimize, in addition to a cervical plexus block, the quality of anesthesia for carotid endarterectomies.

12.
Medicina (Kaunas) ; 57(8)2021 Jul 30.
Artículo en Inglés | MEDLINE | ID: mdl-34440984

RESUMEN

Background and Objectives: A rare case of cor triatriatum sinistrum in combination with anomalies in the atrial septum and in the right atrium of a 60-year-old female body donor is described here. Materials and Methods: In addition to classical dissection, ultrasound and magnetic resonance imaging, computer tomography and cinematic rendering were performed. In a reference series of 59 regularly formed hearts (33 men, 26 women), we looked for features in the left and right atrium or atrial septum. In addition, we measured the atrial and ventricular wall thickness in 15 regularly formed hearts (7 men, 8 women). Results: In the case described, the left atrium was partly divided into two chambers by an intra-atrial membrane penetrated by two small openings. The 2.5 cm-high membrane originated in the upper level of the oval fossa and left an opening of about 4 cm in diameter. Apparently, the membrane did not lead to a functionally significant flow obstruction due to the broad intra-atrial communication between the proximal and distal chamber of the left atrium. In concordance with this fact, left atrial wall thickness was not elevated in the cor triatriatum sinistrum when compared with 15 regularly formed hearts. In addition, two further anomalies were found: 1. the oval fossa was deepened and arched in the direction of the left atrium; 2. the right atrium showed a membrane-like structure at its posterior and lateral walls, which began at the lower edge of the oval fossa. It probably corresponds to a strongly developed eustachian valve (valve of the inferior vena cava). Conclusions: The case described suggests that malformations in the development of the atrial septum and in the regression of the valve of the right sinus vein are involved in the pathogenesis of cor triatriatum sinistrum.


Asunto(s)
Tabique Interatrial , Corazón Triatrial , Tabique Interatrial/diagnóstico por imagen , Corazón Triatrial/diagnóstico por imagen , Femenino , Atrios Cardíacos/diagnóstico por imagen , Humanos , Imagen por Resonancia Magnética , Masculino , Persona de Mediana Edad , Vena Cava Inferior
13.
Materials (Basel) ; 14(5)2021 Feb 25.
Artículo en Inglés | MEDLINE | ID: mdl-33668996

RESUMEN

One main disadvantage of commercially available allogenic bone substitute materials is the altered mechanical behavior due to applied material processing, including sterilization methods like thermal processing or gamma irradiation. The use of high hydrostatic pressure (HHP) might be a gentle alternative to avoid mechanical alteration. Therefore, we compressed ground trabecular human bone to granules and, afterwards, treated them with 250 and 300 MPa for 20 and 30 min respectively. We characterized the formed bone granule cylinders (BGC) with respect to their biomechanical properties by evaluating stiffness and stress at 15% strain. Furthermore, the stiffness and yield strength of HHP-treated and native human trabecular bone cylinders (TBC) as control were evaluated. The mechanical properties of native vs. HHP-treated TBCs as well as HHP-treated vs. untreated BGCs did not differ, independent of the applied HHP magnitude and duration. Our study suggests HHP treatment as a suitable alternative to current processing techniques for allogenic bone substitutes since no negative effects on mechanical properties occurred.

14.
Anat Cell Biol ; 54(1): 25-34, 2021 03 31.
Artículo en Inglés | MEDLINE | ID: mdl-33583827

RESUMEN

The vertebral trabecular bone has a complex three-dimensional microstructure with an inhomogeneous morphology. Correct identification and assessment of the weakest segments of the cancellous bone may lead to better prediction of fracture risk. The aim of this study was to compare cancellous bone from 240 vertebrae of the cervical, thoracic and lumbar spine of ten body donors with osteoporosis in regard to bone volume fraction (BVF), trabecular thickness, separation, trabecular number and degree of anisotropy, to ascertain why cervical vertebrae rarely fracture, even with severe osteoporosis. Samples were obtained from all vertebrae with a Jamshidi needle (8 Gauge). The investigations were performed with a micro-computed tomography (micro-CT) device (SKYSCAN 1172, RJL Micro & Analytic GmbH, Karlsdorf-Neuthard, Germany). Existing vertebral fractures and the bone mineral density of the lumbar spine were assessed with quantitative CT. Regarding the micro-CT parameters, statistically significant differences were observed between the various sections of the spine. We found a higher BVF, trabecular number and trabecular thickness, as well as a lower trabecular separation of the cervical vertebrae compared to other vertebrae. In addition, the degree of anisotropy in the cervical spine is lower than in the other spinal column sections. These results are age and sex dependent. Thus, the cervical spine has special structural features, whose causes must be determined in further investigations.

15.
Front Cardiovasc Med ; 7: 602179, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-33330664

RESUMEN

The demand for cardiac implantable electronic devices for arrhythmia therapy is still unabated and rising. Despite onward optimizations, lead-related problems such as infections or fractures often necessitate lead extraction. Due to adhesive thrombo-fibrotic lead encapsulations (TFLE) transvenous lead extraction is challenging and risky. However, knowledge on TFLEs and possible correlations with technical lead parameters and dwelling time (DT) were hitherto insufficiently studied. Therefore, we analyzed TFLEs of 62 lead from 35 body donor corpses to gain information for a potential lead design optimization. We examined both TFLE topography on the basis on anatomical landmarks and histo-morphological TFLE characteristics by means of histological paraffin sections and scanning electron microscopy of decellularized samples. The macroscopic analysis revealed that all leads were affected by TFLEs, mainly in the lead bearing veins. Half (47.2%) of the right-ventricular leads possessed adhesions to the tricuspid valve. On average, 49.9 ± 21.8% of the intravascular lead length was covered by TFLE of which 82.8 ± 16.2% were adhesive wall bindings (WB). The discrete TFLEs with at least one WB portion had a mean length of 95.0 ± 64.3 mm and a maximum of 200 mm. Neither sex, DT nor certain technical lead parameters showed distinct tendencies to promote or prevent TFLE. TFLE formation seems to start early in the first 1-2 weeks after implantation. The degree of fibrotization of the TFLE, starting with a thrombus, was reflected by the amount of compacted collagenous fibers and likewise largely independent from DT. TFLE thickness often reached several hundred micrometers. Calcifications were occasionally seen and appeared irregularly along the TFLE sheath. Leadless pacemaker systems have the advantage to overcome the problem with TFLEs but hold their own specific risks and limitations which are not fully known yet.

16.
Reg Anesth Pain Med ; 45(2): 102-106, 2020 02.
Artículo en Inglés | MEDLINE | ID: mdl-31678963

RESUMEN

BACKGROUND AND OBJECTIVES: We hypothesized that different injection techniques and volumes in thoracic-paravertebral blocks (TPVB) lead to different patterns of dye spread. In particular, we investigated whether an alternating injection technique leads to complete staining of all adjacent intercostal nerves. METHODS: This comparative anatomical investigation was performed using 10 or 20 mL of dye (Alcian Blue) in 10 unfixed donor cadavers (54 injections) that were designated for education or research purposes. RESULTS: In landmark-guided TPVB, the thoracic-paravertebral space (TPVS) was either not stained at all (spread of dye in the paraspinal muscles, n=3) or the dye was predominantly found in the epidural space (n=3). In ultrasound-guided TPVB, the TPVS was correctly identified in all cases (n=48). The sympathetic trunk was stained in 84.6% of injections (multi-injection technique: 100%), independent of injection technique and volume. The epidural space was stained more frequently (p≤0.001) if both the puncture site (sagittal transducer position) and guidance of the needle were more medial (77.8%). Finally, a higher injection volume (20 vs 10 mL) resulted in a higher number of stained intercostal nerves (p=0.04). CONCLUSION: For ultrasound-guided techniques, a higher injection volume resulted in a larger number of stained intercostal nerves. Staining of the sympathetic trunk was independent of the injection technique. Epidural spread was observed significantly less frequently if the injection was lateral (transducer transversal) or with a strictly cranial injection direction (transducer sagittal). Landmark-guided injections reliably achieved the TPVS (and the epidural space) only after a needle advance of 2.5 cm after initial contact with the transverse process.


Asunto(s)
Bloqueo Nervioso/métodos , Vértebras Torácicas/anatomía & histología , Ultrasonografía Intervencional/métodos , Anciano , Cadáver , Espacio Epidural , Femenino , Humanos , Nervios Intercostales , Masculino , Vértebras Torácicas/diagnóstico por imagen
17.
PLoS One ; 14(9): e0223121, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-31557251

RESUMEN

INTRODUCTION: In cases with residual-hearing (RH) loss after cochlear implantation, a safe method is needed to provide full spectral resolution and as much auditory information as possible without implant replacement. Aim of this study was to prove the feasibility of accessing a partially inserted cochlear-implant-electrode for complete insertion to its maximum length through the external ear canal using a transcanal approach. METHODS: Two CI electrodes were customized with 18 stimulating channels. The electrode design enables the use of 12 active channels available for electrical stimulation inside the cochlea both after partial and full insertion. 10 CI electrodes were implanted in 10 fresh human cadaveric temporal bones. After initial partial insertion by posterior tympanotomy, the electrode was inserted to its maximum length via a transcanal approach. Radiographs and CT scans were performed to confirm the electrode position. The electrodes were investigated via x-ray after removal. RESULTS: X-ray and CT-scans confirmed the electrode prototypes covering an angular insertion depth between 236° to 307° after initial insertion. Accessing the electrode in the middle ear space was feasible and insertion to its full length was successful. Post-insertion CT confirmed insertion of the 28mm and 31.5mm electrode arrays covering an angular insertion depth between 360° and 540° respectively. No tip foldovers were detected. CONCLUSION: This study confirms the feasibility of extending the electrode insertion to its maximum insertion length using a transcanal approach in temporal bone specimens. This constitutes a second stage procedure on demand in EAS-surgery. This may be beneficial for EAS-patients providing electrical stimulation beyond the basal turn of the cochlea once the functional residual hearing is lost, without replacing the entire CI.


Asunto(s)
Estimulación Acústica/métodos , Implantación Coclear/métodos , Implantes Cocleares , Terapia por Estimulación Eléctrica/métodos , Electrodos Implantados , Pérdida Auditiva/cirugía , Estimulación Acústica/instrumentación , Cóclea/diagnóstico por imagen , Cóclea/cirugía , Implantación Coclear/instrumentación , Terapia por Estimulación Eléctrica/instrumentación , Diseño de Equipo , Estudios de Factibilidad , Humanos , Tomografía Computarizada por Rayos X
18.
Clin Anat ; 31(7): 1065-1076, 2018 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-30240062

RESUMEN

The femoral vein (FV) is a clinically important vessel. Failure of its valves can lead to chronic venous insufficiency (CVI) with severe manifestations such as painful ulcers. Although they are crucial for identifying suitable implant sites for therapeutic valves, studies on the topography of FV tributaries and valves are rare. Moreover, the femoral vein diameter (FVD) must be known to assess the morphometric requirements for valve implants. To reassess the anatomical requirements for valve implants, 155 FVs from 82 human corpses were examined. FVDs and tributary and valve topographies were assessed using a laboratory straightedge. The FVD increased from 6 mm in the distal femoropopliteal vein to 11 mm in the iliofemoral vein proximal to the saphenofemoral junction (SFJ). Diameters were significantly bigger in males than females. Height correlated positively with FVD. Distal to the SFJ, within a distance of 38 cm, one to eight valves were present. Up to two valves were present within 10 cm proximal to the SFJ. Individual tributary and valve topography must be considered to ensure appropriate design and successful implantation of a venous valve for CVI therapy in the FV. A suitable implant site would be proximal to the SFJ via an infrainguinal transfemoral access. Clin. Anat. 31:1065-1076, 2018. © 2018 Wiley Periodicals, Inc.


Asunto(s)
Vena Femoral/anatomía & histología , Vena Poplítea/anatomía & histología , Vena Safena/anatomía & histología , Válvulas Venosas/anatomía & histología , Anciano , Anciano de 80 o más Años , Estatura/fisiología , Cadáver , Femenino , Vena Femoral/trasplante , Humanos , Masculino , Persona de Mediana Edad , Factores Sexuales , Insuficiencia Venosa/cirugía
19.
Ann Anat ; 219: 76-81, 2018 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-29936218

RESUMEN

As calcium and phosphorus are of vital importance for life, physiological activity of the parathyroid glands (PTGs) is crucial to maintain mineral homeostasis and bone mineralization. However, PTG-specific molecular routes in response to environmental factors and intrinsic hormonal responses are not yet fully understood. Since nutrient requirements, pathophysiology and functional genomics of pigs are similar to those of humans, pigs might be a suitable model to study the holistic gene expression and physiological aspects of the parathyroid gland, which could be used in both animal sciences and biomedical research. However, due to their small size and hidden location, the dissection of the PTGs, particularly in pigs, is difficult. Therefore, a protocol for untrained dissectors has been established that allows a fast and reliable identification of the PTGs in domestic pigs. Based on their localization within the cranial thymus near the carotid bifurcation, sampling was verified by histological staining and mRNA expression pattern. Analyses revealed the prominence of parathyroid hormone (PTH)-producing chief cells. Moreover, the copy numbers of PTH differed substantially between the PTGs and their surrounding thymus tissue, as PTH was expressed virtually exclusively in the PTGs. The developed protocol will substantially facilitate a fast and reliable dissection of porcine PTGs which is essential for studies characterizing the molecular mechanisms of parathyroid glands, e.g. when applying new feeding strategies in pigs.


Asunto(s)
Disección/normas , Glándulas Paratiroides/anatomía & histología , Porcinos/anatomía & histología , Animales , ADN Complementario/biosíntesis , ADN Complementario/química , Femenino , Perfilación de la Expresión Génica , Hormona Paratiroidea/genética , ARN/genética , ARN/aislamiento & purificación , Reacción en Cadena en Tiempo Real de la Polimerasa , Proteínas Ribosómicas/genética , Porcinos/genética , Timo/anatomía & histología
20.
Local Reg Anesth ; 10: 61-65, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-28740428

RESUMEN

The anterior cutaneous branches of the thoracolumbar spinal nerves enter the rectus sheath at its lateral border and perforate the muscle after travelling a short distance in the ventral direction. In this anatomical case series, we show that dye injection at the medial margin did not lead to reliable impregnation of the target nerves. The local anesthetic should therefore be injected at the lateral edge of the rectus sheath. Preceding surgical procedures to the ventral abdominal wall may affect the craniocaudal spread of local anesthetic.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...