Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 111
Filtrar
1.
J Med Virol ; 96(9): e29881, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-39221498

RESUMEN

While HC2 and GP5+/6+ PCR-EIA were pivotal in test validation of new HPV assays, they represent the first generation of comparator tests based upon technologies that are not in widespread use anymore. In the current guideline, criteria for second-generation comparator tests are presented that include more detailed resolution of HPV genotypes. Second-generation comparator tests should preferentially target only the 12 genotypes classified as carcinogenic (IARC-group I), and show consistent non-inferior sensitivity for CIN2+ and CIN3+ and specificity for ≤CIN1 compared to one of the first-generations comparators, in at least three validation studies using benchmarks of 0.95 for relative sensitivity and 0.98 for relative specificity. Validation should take into account used storage media and other sample handling procedures. Meta-analyses were conducted to identify the assays that fulfill these stringent criteria. Four tests fulfilled the new criteria: (1) RealTime High-Risk HPV Test (Abbott), (2) Cobas-4800 HPV test (Roche Molecular System), (3) Onclarity HPV Assay (BD Diagnostics), and (4) Anyplex II HPV HR Detection (Seegene), each evaluated in three to six studies. Whereas the four assays target 14 carcinogenic genotypes, the first two identify separately HPV16 and 18, the third assay identifies five types separately and the fourth identifies all the types separately.


Asunto(s)
Detección Precoz del Cáncer , Papillomaviridae , Infecciones por Papillomavirus , Sensibilidad y Especificidad , Neoplasias del Cuello Uterino , Humanos , Femenino , Infecciones por Papillomavirus/diagnóstico , Infecciones por Papillomavirus/virología , Neoplasias del Cuello Uterino/diagnóstico , Neoplasias del Cuello Uterino/virología , Detección Precoz del Cáncer/métodos , Papillomaviridae/genética , Papillomaviridae/clasificación , Papillomaviridae/aislamiento & purificación , Genotipo , Técnicas de Diagnóstico Molecular/métodos , Técnicas de Diagnóstico Molecular/normas , ADN Viral/genética , Pruebas de ADN del Papillomavirus Humano/métodos , Pruebas de ADN del Papillomavirus Humano/normas
2.
J Clin Virol ; 174: 105722, 2024 Aug 24.
Artículo en Inglés | MEDLINE | ID: mdl-39213759

RESUMEN

BACKGROUND: Adenovirus infections constitute an important cause of morbidity and mortality after hematopoietic stem cell transplantation. Detection and monitoring of adenovirus in EDTA-plasma by real-time quantitative PCR is a sensitive tool for identification and management of patients at risk of a potentially fatal infection. OBJECTIVES: The aim of this study was to evaluate the analytical and clinical performance of the quantitative Adenovirus ELITe MGB® Kit (ELITechGroup S.p.A.) using the ELITe BeGenius® (ELITechGroup S.p.A.) system and compare the assay to a laboratory-developed quantitative real-time PCR assay. STUDY DESIGN: Analytical sensitivity of the Adenovirus ELITe MGB® Kit was determined by testing serial dilutions of the WHO standard. Detection of adenovirus serotypes was assessed using a panel of 51 serotypes. Clinical sensitivity and specificity were determined by comparing the Adenovirus ELITe MGB® Kit results with the laboratory-developed assay results of 155 retrospective and prospective EDTA-plasma samples from transplant recipients. RESULTS: The analytical sensitivity of the Adenovirus ELITe MGB® Kit was at least 54 (1.7 Log) IU/mL and the quantitative results showed a high correlation with the WHO standard (R2 = 0.9978; Pearson) within the range of 1.7 to 6.6 Log IU/mL. All 51 adenovirus serotypes were detected. The clinical specificity and sensitivity for EDTA plasma of the Adenovirus ELITe MGB® Kit were 97.4 % and 99.1 % respectively. CONCLUSION: The Adenovirus ELITe MGB® Kit performed on the ELITe BeGenius® system is a highly sensitive and specific assay for the detection of adenovirus in EDTA-plasma from transplantation patients.

4.
Expert Rev Mol Diagn ; 23(4): 279-281, 2023 04.
Artículo en Inglés | MEDLINE | ID: mdl-37010455

RESUMEN

This report provides an overview of the highlights of the 12th European Meeting on Molecular Diagnostics held in Noordwijk aan Zee, The Netherlands, 12-14 October 2022. This 3-day conference covered many relevant topics in the field of molecular diagnostics in humans i.e. oncology, infectious diseases, laboratory medicine, pharmacogenetics, pathology, and preventive medicine. Other relevant topics included quality management, laboratory automation, diagnostic preparedness, and lessons learned from the COVID pandemic. More than 400 participants, the majority coming from European countries, attended the meeting. Besides high-quality scientific presentations, more than 40 diagnostic companies presented their latest innovations, altogether in an informal and inspiring ambiance.


Asunto(s)
COVID-19 , Patología Molecular , Humanos , Países Bajos , COVID-19/diagnóstico , COVID-19/epidemiología , Europa (Continente) , Oncología Médica , Prueba de COVID-19
5.
AIDS ; 36(14): 1959-1968, 2022 11 15.
Artículo en Inglés | MEDLINE | ID: mdl-35950949

RESUMEN

INTRODUCTION: Standard-of-care antiretroviral treatment (ART) monitoring in low and middle-income countries consists of annual determination of HIV-RNA viral load with confirmatory viral load testing in case of viral rebound. We evaluated an intensified monitoring strategy of three-monthly viral load testing with additional drug exposure and drug resistance testing in case of viral rebound. METHODS: We performed an open-label randomized controlled trial (RCT) at a rural South African healthcare clinic, enrolling adults already receiving or newly initiating first-line ART. During 96 weeks follow-up, intervention participants received three-monthly viral load testing and sequential point-of-care drug exposure testing and DBS-based drug resistance testing in case of rebound above 1000 copies/ml. Control participants received standard-of-care monitoring according to the WHO guidelines. RESULTS: Five hundred one participants were included, of whom 416 (83.0%) were randomized at 24 weeks. Four hundred one participants were available for intention-to-treat analysis. Viral rebound occurred in 9.0% (18/199) of intervention participants and in 11.9% (24/202) of controls ( P  = 0.445). Time to detection of rebound was 375 days [interquartile range (IQR): 348-515] in intervention participants and 360 days [IQR: 338-464] in controls [hazard ratio: 0.88 (95% confidence interval (95% CI): 0.46-1.66]; P  = 0.683]. Duration of viral rebound was 87 days [IQR: 70-110] in intervention participants and 101 days [IQR: 78-213] in controls ( P  = 0.423). In the control arm, three patients with confirmed failure were switched to second-line ART. In the intervention arm, of three patients with confirmed failure, switch could initially be avoided in two cases. CONCLUSION: Three-monthly viral load testing did not significantly reduce the duration of viraemia when compared with standard-of-care annual viral load testing, providing randomized trial evidence in support of annual viral load monitoring.


Asunto(s)
Fármacos Anti-VIH , Infecciones por VIH , Adulto , Humanos , Fármacos Anti-VIH/uso terapéutico , Resultado del Tratamiento , Antirretrovirales/uso terapéutico , Carga Viral , Resistencia a Medicamentos
6.
AIDS ; 36(7): 923-931, 2022 06 01.
Artículo en Inglés | MEDLINE | ID: mdl-35113046

RESUMEN

INTRODUCTION: Pretreatment drug resistance (PDR) prevalence in sub-Saharan Africa is rising, but evidence of its impact on efavirenz (EFV)-based antiretroviral treatment (ART) is inconclusive. We determined the impact of PDR on outcomes of EFV-based ART in a subanalysis of a randomized clinical trial comparing different ART monitoring strategies implemented at a rural treatment facility in Limpopo, South Africa. METHODS: Participants initiating EFV-based first-line ART (2015-2017) were enrolled and received 96 weeks follow-up. Resistance to nucleos(t)ide reverse transcriptase inhibitors (NRTIs) and non-NRTI's (NNRTIs) was retrospectively assessed by population-based sequencing. Virological failure was defined as a viral load of at least 1000 copies/ml after at least 24 weeks of ART. RESULTS: A total of 207 participants were included, 60.4% (125/207) of whom were female. Median age was 38.8 (interquartile range: 31.4-46.7) years. Median CD4+ cell count was 191 (interquartile range: 70-355) cells/µl. PDR was detected in 12.9% (25/194) of participants with available sequencing results; 19 had NNRTI-resistance, and six had NRTI- and NNRTI-resistance. 26.0% of participants (40/154) with sequencing results and virological follow-up developed virological failure. PDR was independently associated with failure (adjusted hazard ratio: 3.7 [95% confidence interval: 1.68.5], P = 0.002). At failure, 87.5% (7/8) of participants with PDR harboured dual-class resistant virus, versus 16.7% (4/24) of participants without PDR (P = 0.0007). Virological resuppression after failure on first-line ART occurred in 57.7% (15/26) of participants without PDR versus 14.3% (1/7) of participants with PDR (P = 0.09). CONCLUSION: PDR was detected in 13% of study participants. PDR significantly increased the risk of virological failure of EFV-based ART. Accumulation of resistance at failure and inability to achieve virological resuppression illustrates the profound impact of PDR on treatment outcomes.


Asunto(s)
Fármacos Anti-VIH , Infecciones por VIH , Seropositividad para VIH , VIH-1 , Adulto , Fármacos Anti-VIH/farmacología , Fármacos Anti-VIH/uso terapéutico , Antirretrovirales/farmacología , Antirretrovirales/uso terapéutico , Resistencia a Medicamentos , Farmacorresistencia Viral , Femenino , Seropositividad para VIH/tratamiento farmacológico , VIH-1/genética , Humanos , Masculino , Estudios Retrospectivos , Carga Viral
7.
Open Forum Infect Dis ; 9(1): ofab553, 2022 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-34988250

RESUMEN

Severe acute respiratory syndrome coronavirus 2 infection after coronavirus disease 2019 vaccination raises concerns about the emergence of vaccine escape variants. Here we characterize 14 breakthrough infections among 5860 fully vaccinated Dutch health care workers ≥14 days after the final dose of vaccination with either BNT162b2, mRNA-1273, or Ad26.COV2.S. These breakthrough infections presented with regular B.1.1.7 (Alpha) and B.1.617.2 (Delta) variants and high viral loads, despite normal vaccine-induced B- and T-cell immune responses detected by live virus neutralization assays and ELISpot. High-risk exposure settings, such as in households, indicate a potential risk of viral transmission despite full vaccination.

8.
Lancet Reg Health Eur ; 11: 100235, 2021 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-34918001

RESUMEN

BACKGROUND: High-risk human papillomavirus (hrHPV) testing on self-collected samples has potential as a primary screening tool in cervical screening, but real-world evidence on its accuracy in hrHPV-based screening programmes is lacking. METHODS: In the Netherlands, women aged 30-60 years invited for cervical screening can choose between sampling at the clinician's office (Cervex Brush) or self-sampling at home (Evalyn Brush). HrHPV testing is performed using Roche Cobas 4800. We collected screening test results between January 2017 and March 2018 and histological follow-up until August 2019. The main outcome measures were mean cycle threshold (Ct) value, cervical intraepithelial neoplasia (CIN) grade 3 or cancer (CIN3+) and CIN grade 2 or worse (CIN2+). FINDINGS: 30,808 women had a self-collected and 456,207 had a clinician-collected sample. In hrHPV-positive women with adequate cytology, Ct values were higher for self-collection than clinician-collection with a mean Ct difference of 1·25 (95% CI 0·98-1·52) in women without CIN2+, 2·73 (1·75-3·72) in CIN2 and 3·59 (3·03-4·15) in CIN3+. The relative sensitivity for detecting CIN3+ was 0·94 (0·90-0·97) for self-collection versus clinician-collection and the relative specificity was 1·02 (1·02-1·02). INTERPRETATION: The clinical accuracy of hrHPV testing on a self-collected sample for detection of CIN3+ is high and supports its use as a primary screening test for all invited women. Because of the slightly lower sensitivity of hrHPV testing on a self-collected compared to a clinician-collected sample, an evaluation of the workflow procedure to optimise clinical performance seems warranted. FUNDING: National Institute for Public Health and the Environment (the Netherlands) and the European Commission.

9.
Pediatrics ; 148(6)2021 12 01.
Artículo en Inglés | MEDLINE | ID: mdl-34814164

RESUMEN

OBJECTIVES: Rotavirus vaccination has 87% to 100% effectiveness against severe rotavirus acute gastroenteritis (AGE) in healthy infants in high-income countries. Little is known whether infants with medical risk conditions (MRCs) are equally protected and if the vaccine is equally well tolerated. We conducted a quasi-experimental prospective multicenter before-after cohort study to assess the vaccine effectiveness (VE) and safety profile of the human rotavirus vaccine (HRV) among MRC infants that required prolonged or frequent postnatal care. METHODS: The Netherlands has no national rotavirus immunization program, but HRV was implemented in routine care for MRC infants in 13 Dutch hospitals. Participants in the before and after cohort, HRV unvaccinated and vaccinated, respectively, were followed for occurrence of (rotavirus) AGE. VE of at least 1 dose was estimated by using time-to-event analysis for severe rotavirus AGE. Vaccine-related serious adverse event (AEs) after HRV were retrieved systematically from medical charts. Solicited AEs after vaccinations were prospectively collected and compared between vaccination time points with or without HRV. RESULTS: In total, 1482 high-risk infants with MRC were enrolled, including 631 in the before and 851 in the after cohorts; 1302 infants were premature (88.3%), 447 were small for gestational age (30.2%), and 251 had at least 1 congenital disorder (17.0%). VE against severe rotavirus AGE was 30% (95% confidence interval [CI]: -36% to 65%). Overall, the observed number of rotavirus hospitalizations was low and not significantly different between the cohorts (2 and 2, respectively). The rate of vaccine-related serious AE was 0.24 per 100 vaccine doses. The adjusted risk ratio for any AE after HRV vaccination compared with other routine vaccinations was 1.09 (95% CI: 1.05 to 1.12) for concomitant administration and 0.91 (95% CI: 0.81 to 0.99) for single HRV administration. Gastrointestinal AEs were 10% more frequent after HRV. CONCLUSIONS: In contrast to previous findings among healthy term infants, in routine use, HRV offered limited protection to vulnerable medical risk infants. HRV is generally well tolerated in this group in single administration, but when coadministered with routine vaccines, it is associated with higher risk of (mostly gastrointestinal) AE. Our study highlights the importance of studying vaccine performance in subgroups of medically vulnerable infants.


Asunto(s)
Gastroenteritis/epidemiología , Infecciones por Rotavirus/epidemiología , Vacunas contra Rotavirus/efectos adversos , Eficacia de las Vacunas , Anomalías Congénitas/epidemiología , Estudios Controlados Antes y Después , Femenino , Gastroenteritis/virología , Hospitalización/estadística & datos numéricos , Humanos , Lactante , Recien Nacido Prematuro , Recién Nacido Pequeño para la Edad Gestacional , Masculino , Países Bajos/epidemiología , Estudios Prospectivos , Vacunas contra Rotavirus/administración & dosificación , Cobertura de Vacunación
10.
BMJ Open ; 11(10): e048206, 2021 10 13.
Artículo en Inglés | MEDLINE | ID: mdl-34645658

RESUMEN

BACKGROUND: Antigen-based point-of-care tests for identification of SARS-CoV-2 may markedly enhance effectiveness of population-based controlling strategies. Previous studies have demonstrated >70% sensitivity and high specificity compared with reverse transcriptase real-time PCR (RT-PCR) in symptomatic individuals, but test performance for asymptomatic individuals is unknown. METHODS: Test performance of the Panbio COVID-19 Ag Rapid Test (Abbott) was compared with RT-PCR in a longitudinal cohort study of asymptomatic football players and staff members of professional football clubs. Based on timing of symptoms and prior and subsequent test results, positive RT-PCR tests were categorised as presymptomatic, early or late infection, or persistent RNA shedding. FINDINGS: 2425 tests were performed in 824 individuals, of which 52 (6.3%) were SARS-CoV-2 positive based on RT-PCR. There were 2406 paired sets from asymptomatic subjects for analysis. Sixteen Panbio tests were inconclusive, for which sensitivity analyses were performed (considering results as either positive or negative or being excluded). Sensitivity of Panbio for screening of asymptomatic individuals ranged from 80.0% (61.4-92.3) to 86.67% (69.2-96.2) and specificity from 99.53% (95% CI 99.2 to 99.8) to 100% (95% CI 99.8 to 100). Sensitivity of Panbio to detect subjects with presymptomatic/early infection (n=42) ranged from 81.82% (95% CI 67.3 to 91.8) to 90.91% (95% CI 78.3 to 97.5) with specificity always above 99%. INTERPRETATION: The Panbio COVID-19 Ag rapid test identifies 81%-90% of presymptomatic and early asymptomatic SARS-CoV-2 infections with high specificity. This test may therefore be adopted in testing strategies such as targeted screening of specific populations where prevalence is low.


Asunto(s)
COVID-19 , SARS-CoV-2 , Antígenos Virales , Estudios de Cohortes , Humanos , Estudios Longitudinales , Estudios Prospectivos , Reacción en Cadena en Tiempo Real de la Polimerasa , Reacción en Cadena de la Polimerasa de Transcriptasa Inversa , Sensibilidad y Especificidad
11.
J Acquir Immune Defic Syndr ; 87(4): 1072-1078, 2021 08 01.
Artículo en Inglés | MEDLINE | ID: mdl-34153013

RESUMEN

BACKGROUND: Virological failure during antiretroviral treatment (ART) may indicate the presence of drug resistance, but may also originate from nonadherence. Qualitative detection of ART components using drug level testing may be used to differentiate between these scenarios. We aimed to validate and implement qualitative point-of-care drug level tests for efavirenz (EFV), lopinavir (LPV), and dolutegravir (DTG) in rural South Africa. METHODS: Qualitative performance of immunoassays for EFV, LPV, and DTG was assessed by calculating limit of detection (LoD), region of uncertainty, and qualitative agreement with a reference test. Minimum duration of nonadherence resulting in a negative drug level test was assessed by simulation of treatment cessation using validated population pharmacokinetic models. RESULTS: LoD was 0.05 mg/L for EFV, 0.06 mg/L for LPV, and 0.02 mg/L for DTG. Region of uncertainty was 0.01-0.06 mg/L for EFV, 0.01-0.07 mg/L for LPV, and 0.01-0.02 mg/L for DTG. Qualitative agreement with reference testing at the LoD in patient samples was 95.2% (79/83) for EFV, 99.3% (140/141) for LPV, and 100% (118/118) for DTG. After simulated treatment cessation, median time to undetectability below LoD was 7 days [interquartile range (IQR) 4-13] for EFV, 30 hours (IQR 24-36) for LPV, and 6 days (IQR 4-7) for DTG. CONCLUSIONS: We demonstrate that qualitative ART drug level testing using immunoassays is feasible in a rural resource-limited setting. Implementation of this technology enables reliable detection of recent nonadherence and may allow for rapid and cost-effective differentiation between patients in need for adherence counseling and patients who require drug resistance testing or alternative treatment.


Asunto(s)
Alquinos/administración & dosificación , Fármacos Anti-VIH/sangre , Benzoxazinas/administración & dosificación , Ciclopropanos/administración & dosificación , Compuestos Heterocíclicos con 3 Anillos/administración & dosificación , Lopinavir/administración & dosificación , Cumplimiento de la Medicación , Oxazinas/administración & dosificación , Piperazinas/administración & dosificación , Pruebas en el Punto de Atención/normas , Piridonas/administración & dosificación , Alquinos/farmacocinética , Alquinos/uso terapéutico , Fármacos Anti-VIH/administración & dosificación , Benzoxazinas/farmacocinética , Benzoxazinas/uso terapéutico , Ciclopropanos/farmacocinética , Ciclopropanos/uso terapéutico , Infecciones por VIH/tratamiento farmacológico , Infecciones por VIH/metabolismo , VIH-1 , Compuestos Heterocíclicos con 3 Anillos/farmacocinética , Compuestos Heterocíclicos con 3 Anillos/uso terapéutico , Humanos , Técnicas para Inmunoenzimas/métodos , Límite de Detección , Lopinavir/farmacocinética , Lopinavir/uso terapéutico , Oxazinas/farmacocinética , Oxazinas/uso terapéutico , Piperazinas/farmacocinética , Piperazinas/uso terapéutico , Pruebas en el Punto de Atención/economía , Piridonas/farmacocinética , Piridonas/uso terapéutico , Reproducibilidad de los Resultados , Población Rural , Sudáfrica
12.
EClinicalMedicine ; 31: 100677, 2021 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-33521610

RESUMEN

BACKGROUND: RT-qPCR is the reference test for identification of active SARS-CoV-2 infection, but is associated with diagnostic delay. Antigen detection assays can generate results within 20 min and outside of laboratory settings. Yet, their diagnostic test performance in real life settings has not been determined. METHODS: The diagnostic value of the Panbio™ COVID-19 Ag Rapid Test (Abbott), was determined in  comparison to RT-qPCR (Seegene Allplex) in community-dwelling mildly symptomatic subjects in a medium (Utrecht, the Netherlands) and high endemic area (Aruba), using two concurrently obtained nasopharyngeal swabs.Findings: 1367 and 208 subjects were enrolled in Utrecht and Aruba, respectively. SARS-CoV-2 prevalence, based on RT-qPCR, was 10.2% (n = 139) and 30.3% (n = 63) in Utrecht and Aruba respectively. Specificity of the Panbio™ COVID-19 Ag Rapid Test was 100% (95%CI: 99.7-100%) in both settings. Test sensitivity was 72.6% (95%CI: 64.5-79.9%) in the Netherlands and 81.0% (95% CI: 69.0-89.8%) in Aruba. Probability of false negative results was associated with RT-qPCR Ct-values, but not with duration of symptoms. Restricting RT-qPCR test positivity to Ct-values <32 yielded test sensitivities of 95.2% (95%CI: 89.3-98.5%) in Utrecht and 98.0% (95%CI: 89.2-99.95%) in Aruba. INTERPRETATION: In community-dwelling subjects with mild respiratory symptoms the Panbio™ COVID-19 Ag Rapid Test had 100% specificity, and a sensitivity above 95% for nasopharyngeal samples when using Ct-values <32 cycles as cut-off for RT-qPCR test positivity. Considering short turnaround times, user friendliness, low costs and opportunities for decentralized testing, this test can improve our efforts to control transmission of SARS-CoV-2.

13.
J Med Virol ; 93(6): 3999-4003, 2021 06.
Artículo en Inglés | MEDLINE | ID: mdl-32761911

RESUMEN

BACKGROUND: Monitoring viral load (VL) is an essential part of the management of patients chronically infected with hepatitis B virus (HBV). The commercial HBV VL assays currently available are generally performed on high-throughput platforms for batch wise testing of plasma samples, with relatively long turn-around-times. Rapid VL testing could provide immediate input to clinical decision making. METHODS: One hundred two stored plasma samples from 102 patients who were previously tested for HBV VL by the Cobas Ampliprep/Taqman or Cobas 4800 (Roche, Pleasanton, CA), were analyzed by the recently introduced Cepheid Xpert HBV Viral Load Assay. Thirty-one of the 102 samples were negative for HBV DNA and 71 out of 102 samples had a detectable VL. HBV DNA loads ranged from <20 to 5E8 IU/mL. HBV genotypes (A, B, C, D, E, and G) were known for 52 of the VL positive samples. Correlation of VL results between both assays was determined by the Pearson correlation coefficient (r2 ). The level of concordance was assessed using the Bland-Altman analysis. RESULTS: HBV VLs correlated well between both assays, across all genotypes (Pearson correlation coefficient r2 = 0.987). Six samples exceeded a 0.5 log difference between assays. Bland-Altman analysis demonstrated a mean of the difference of -0.107 log and a standard deviation of 0.271 log. CONCLUSION: High correlation was observed between the Roche Cobas HBV Viral Load tests and the Xpert HBV Viral Load Assay, thus enabling rapid, random access, and accurate HBV VL assessment.


Asunto(s)
ADN Viral/sangre , Virus de la Hepatitis B/genética , Hepatitis B/diagnóstico , Técnicas de Diagnóstico Molecular/métodos , Carga Viral/instrumentación , Carga Viral/métodos , Genotipo , Hepatitis B/sangre , Hepatitis B/virología , Virus de la Hepatitis B/clasificación , Virus de la Hepatitis B/aislamiento & purificación , Humanos , Límite de Detección , Técnicas de Diagnóstico Molecular/normas , Sensibilidad y Especificidad
14.
J Clin Virol ; 134: 104691, 2021 01.
Artículo en Inglés | MEDLINE | ID: mdl-33278791

RESUMEN

Metagenomic high-throughput sequencing (mHTS) is a hypothesis-free, universal pathogen detection technique for determination of the DNA/RNA sequences in a variety of sample types and infectious syndromes. mHTS is still in its early stages of translating into clinical application. To support the development, implementation and standardization of mHTS procedures for virus diagnostics, the European Society for Clinical Virology (ESCV) Network on Next-Generation Sequencing (ENNGS) has been established. The aim of ENNGS is to bring together professionals involved in mHTS for viral diagnostics to share methodologies and experiences, and to develop application recommendations. This manuscript aims to provide practical recommendations for the wet lab procedures necessary for implementation of mHTS for virus diagnostics and to give recommendations for development and validation of laboratory methods, including mHTS quality assurance, control and quality assessment protocols.


Asunto(s)
Metagenómica , Virus , Secuenciación de Nucleótidos de Alto Rendimiento , Virus/genética
15.
Pediatr Infect Dis J ; 40(4): 300-305, 2021 04 01.
Artículo en Inglés | MEDLINE | ID: mdl-33230056

RESUMEN

BACKGROUND: Infants with medical risk conditions are vulnerable to childhood infections including acute gastroenteritis (AGE). To guide prevention programs, we quantified AGE incidence, severity and virus prevalence among medical risk infants in the Netherlands. METHODS: This prospective cohort-study was part of the RIVAR-project recruiting infants with prematurity, low birth weight or severe congenital conditions in 13 hospitals. Follow-up included 18 monthly health questionnaires detailing AGE symptoms and healthcare usage. Parents were also instructed to notify when an infant developed AGE, to collect a stool sample and complete a daily severity score (Modified Vesikari Severity). Stool samples were analyzed by real-time polymerase chain reaction for rotavirus, norovirus, adenovirus and astrovirus. RESULTS: Between November 2014 and October 2017, 631 infants participated during 9125 person-months of observation. In total, 559 episodes were identified. The mean AGE incidence rate was 73.5 per 100 person-years (PY) (95% confidence interval: 67.6-79.9) and increased with age [incidence rate: 48.3 (39.8-58.3) vs. 80.2 (73.0-88.1)/100 PY for ages 1-5 vs. 6-18 months, respectively]. Healthcare was attended for 38.1% (213/559) and 26.8% (68/254) were classified as severe based on the Modified Vesikari Severity. Stool samples were obtained from 254 AGE episodes. Norovirus was identified in 65 (25.6%) and rotavirus in 44 (17.7%). Adenovirus and astrovirus together accounted for 8.3% (N = 21). Severe AGE occurred most frequently in rotavirus positive episodes. CONCLUSION: The observed AGE incidence, severity and healthcare usage among medical risk infants confirms substantial disease burden. Norovirus and rotavirus are the dominant pathogens and severe episodes occurred most frequently in children with rotavirus infection. AGE prevention in medical risk infants should be prioritized.


Asunto(s)
Costo de Enfermedad , Diarrea/virología , Gastroenteritis/epidemiología , Gastroenteritis/virología , Virus/genética , Enfermedad Aguda/epidemiología , Diarrea/epidemiología , Heces/virología , Humanos , Incidencia , Lactante , Países Bajos/epidemiología , Prevalencia , Estudios Prospectivos , Factores de Riesgo , Índice de Severidad de la Enfermedad , Virus/clasificación , Virus/aislamiento & purificación , Virus/patogenicidad
16.
Front Microbiol ; 11: 560179, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-33281758

RESUMEN

Pediatric allogeneic hematopoietic stem cell transplantation (HSCT) patients often suffer from gastro-intestinal (GI) disease caused by viruses, Graft-versus-Host Disease (GVHD) or a combination of the two. Currently, the GI eukaryotic virome of HSCT recipients remains relatively understudied, which complicates the understanding of its role in GVHD pathogenicity. As decisions regarding immunosuppressive therapy in the treatment of virus infection or GVHD, respectively, can be completely contradicting, it is crucial to better understand the prevalence and relevance of viruses in the GI tract in the HSCT setting. A real time PCR panel for a set of specific viruses widely used to diagnose the most common causes of GI viral gastroenteritis is possibly insufficient to grasp the full extent of viruses present. Therefore, we applied the targeted sequence capture method ViroCap to residual fecal samples of 11 pediatric allogeneic HSCT recipients with GI symptoms and a suspicion of GVHD, to enrich for nucleic acids of viruses that are known to infect vertebrate hosts. After enrichment, NGS was applied to broadly detect viral sequences. Using ViroCap, we were able to detect viruses such as norovirus and adenovirus (ADV), that had been previously detected using clinical diagnostic PCR on the same sample. In addition, multiple, some of which clinically relevant viruses were detected, including ADV, human rhinovirus (HRV) and BK polyomavirus (BKV). Interestingly, in samples in which specific PCR testing for regular viral GI pathogens did not result in a diagnosis, the ViroCap pipeline led to the detection of viral sequences of human herpesvirus (HHV)-7, BKV, HRV, KI polyomavirus and astrovirus. The latter was an only recently described variant and showed extensive sequence mismatches with the applied real time PCR primers and would therefore not have been detected if tested. Our results indicate that target enrichment of viral nucleic acids through ViroCap leads to sensitive and broad possibly clinically relevant virus detection, including the detection of newer variants in clinical HSCT recipient samples. As such, ViroCap could be a useful detection tool clinically, but also in studying the associations between viral presence and GVHD.

17.
J Int AIDS Soc ; 23(6): e25501, 2020 06.
Artículo en Inglés | MEDLINE | ID: mdl-32515898

RESUMEN

INTRODUCTION: When protease inhibitor (PI)-based second-line ART fails, guidelines recommend drug resistance testing and individualized third-line treatment. However, PI-resistant viral strains are rare and drug resistance testing is costly. We investigated whether less costly PI-exposure testing can be used to select those patients who would benefit most from drug resistance testing. METHODS: We performed a retrospective analysis of South African adults living with HIV experiencing failure of ritonavir-boosted-lopinavir (LPV/r)-based second-line ART for whom drug resistance testing results were available. We included patients who received plasma-based drug resistance testing at a central South African reference laboratory in 2017 and patients who received dried blood spots (DBS)-based drug resistance testing at a rural South African clinic between 2009 and 2017. PI-exposure testing was performed on remnant plasma or DBS using liquid chromatography mass spectrometry (LCMS). Additionally, a low-cost immunoassay was used on plasma. Population genotypic drug resistance testing of the pol region was performed on plasma and DBS using standard clinical protocols. RESULTS: Samples from 544 patients (494 plasma samples and 50 DBS) were included. Median age was 41.0 years (IQR: 33.3 to 48.5) and 58.6% were women. Median HIV-RNA load was 4.9 log10 copies/mL (4.3 to 5.4). Prevalence of resistance to the NRTI-backbone was 70.6% (349/494) in plasma samples and 56.0% (28/50) in DBS. Major PI-resistance mutations conferring high-level resistance to LPV/r were observed in 26.7% (132/494) of plasma samples and 12% (6/50) of DBS. PI-exposure testing revealed undetectable LPV levels in 47.0% (232/494) of plasma samples and in 60.0% (30/50) of DBS. In pooled analysis of plasma and DBS samples, detectable LPV levels had a sensitivity of 90% (84% to 94%) and a negative predictive failure of 95% (91% to 97%) for the presence of major LPV/r resistance. CONCLUSIONS: PI-exposure testing revealed non-adherence in half of patients experiencing failure on second-line ART and accurately predicted the presence or absence of clinically relevant PI resistance. PI-exposure testing constitutes a novel screening strategy in patients with virological failure of ART that can differentiate between different underlying causes of therapy failure and may allow for more effective use of limited resources available for drug resistance testing.


Asunto(s)
Infecciones por VIH/tratamiento farmacológico , Inhibidores de la Proteasa del VIH/uso terapéutico , Insuficiencia del Tratamiento , Adulto , Farmacorresistencia Viral/genética , Femenino , Humanos , Lopinavir/uso terapéutico , Masculino , Pruebas de Sensibilidad Microbiana , Persona de Mediana Edad , Estudios Retrospectivos , Ritonavir/uso terapéutico , Carga Viral/efectos de los fármacos
18.
Lancet Infect Dis ; 20(5): 598-606, 2020 05.
Artículo en Inglés | MEDLINE | ID: mdl-32087775

RESUMEN

BACKGROUND: Norovirus and rotavirus are the dominant pathogens causing acute gastroenteritis in children. To quantify their natural disease burden and transmission, we prospectively monitored households in an endemic setting in the Netherlands, a high-income country that does not have a rotavirus vaccination programme. METHODS: We did a prospective, household survey-based cohort study in the Netherlands. Randomly selected households from the Dutch Population Register were invited to participate if they had at least three household members, including a child younger than 2 years. A member of each household was asked to record the gastrointestinal symptoms of all household members every day for 10 consecutie weeks using an interactive smartphone application. Real-time detection of acute gastroenteritis onset on the basis of entered symptoms activated requests for the case and one other household member to complete disease questionnaires and provide stool samples. Stool samples were analysed by real-time PCR for norovirus, rotavirus, adenovirus 40/41, and astrovirus. We calculated the per-pathogen proportion of households with at least one secondary acute gastroenteritis episode (epidemiologically but not microbiologically linked), the probability of a secondary episode in household members at risk (secondary attack rate), and the microbiologically confirmed symptomatic and asymptomatic transmission rates. FINDINGS: During two seasons (January to March) in 2016 and 2017, 30 660 households were invited to participate, of which 604 households including 2298 individuals were enrolled. 697 acute gastroenteritis episodes were detected in 358 households, with samples obtained from 609 (87%) of 697 episodes. Norovirus (150 [25%] of 609 cases) and rotavirus (91 [15%] cases) were most frequently detected. Astrovirus was detected in 50 (8%) samples and adenovirus 40/41 in 24 (4%) samples. Overall disease severity was higher in patients with rotavirus-positive acute gastroenteritis than those with norovirus-positive acute gastroenteritis. Norovirus led to higher disease burden in adults than did rotavirus. Following an index case, a secondary acute gastroenteritis episode occurred in 34 (35%) of 96 households for norovirus and 26 (46%) of 56 households for rotavirus. Secondary attack rates were 15% (37 of 244 participants) for norovirus and 28% (33 of 120 participants) for rotavirus and asymptomatic transmission rates were 51% (52 of 102 household members) for norovirus and 22% (12 of 55 household members) for rotavirus. The microbiologically confirmed symptomatic transmission rate for norovirus was 10% (25 of 254 household members) and 18% for rotavirus (21 of 119 household members). INTERPRETATION: In households with young family members in a setting without rotavirus vaccination, norovirus is the dominant acute gastroenteritis pathogen, but rotavirus is associated with more severe disease. There was substantial within-household transmission, both symptomatic and asymptomatic. The study provides key quantities on transmission, which can inform vaccine policy decisions and act as a baseline for impact evaluations in high-income settings. FUNDING: The Netherlands Organisation for Health Research and Development (grant 91616158).


Asunto(s)
Infecciones por Enterovirus/transmisión , Gastroenteritis/virología , Infecciones por Rotavirus/transmisión , Adenoviridae/patogenicidad , Adolescente , Niño , Preescolar , Diarrea/virología , Infecciones por Enterovirus/virología , Heces/virología , Femenino , Humanos , Lactante , Recién Nacido , Masculino , Países Bajos , Norovirus/patogenicidad , Estudios Prospectivos , Virus ARN/patogenicidad , Rotavirus/patogenicidad , Infecciones por Rotavirus/virología
19.
BMC Med ; 17(1): 228, 2019 12 11.
Artículo en Inglés | MEDLINE | ID: mdl-31829241

RESUMEN

BACKGROUND: In January 2017, the Dutch cervical cancer screening programme transitioned from cytomorphological to primary high-risk HPV (hrHPV) DNA screening, including the introduction of self-sampling, for women aged between 30 and 60 years. The Netherlands was the first country to switch to hrHPV screening at the national level. We investigated the health impact of this transition by comparing performance indicators from the new hrHPV-based programme with the previous cytology-based programme. METHODS: We obtained data from the Dutch nationwide network and registry of histo- and cytopathology (PALGA) for 454,573 women eligible for screening in 2017 who participated in the hrHPV-based programme between 1 January 2017 and 30 June 2018 (maximum follow-up of almost 21 months) and for 483,146 women eligible for screening in 2015 who participated in the cytology-based programme between 1 January 2015 and 31 March 2016 (maximum follow-up of 40 months). We compared indicators of participation (participation rate), referral (screen positivity; referral rate) and detection (cervical intraepithelial neoplasia (CIN) detection; number of referrals per detected CIN lesion). RESULTS: Participation in the hrHPV-based programme was significantly lower than that in the cytology-based programme (61% vs 64%). Screen positivity and direct referral rates were significantly higher in the hrHPV-based programme (positivity rate: 5% vs 9%; referral rate: 1% vs 3%). CIN2+ detection increased from 11 to 14 per 1000 women screened. Overall, approximately 2.2 times more clinical irrelevant findings (i.e. ≤CIN1) were found in the hrHPV-based programme, compared with approximately 1·3 times more clinically relevant findings (i.e. CIN2+); this difference was mostly due to a national policy change recommending colposcopy, rather than observation, of hrHPV-positive, ASC-US/LSIL results in the hrHPV-based programme. CONCLUSIONS: This is the first time that comprehensive results of nationwide implementation of hrHPV-based screening have been reported using high-quality data with a long follow-up. We have shown that both benefits and potential harms are higher in one screening round of a well-implemented hrHPV-based screening programme than in an established cytology-based programme. Lower participation in the new hrHPV programme may be due to factors such as invitation policy changes and the phased roll-out of the new programme. Our findings add further to evidence from trials and modelling studies on the effectiveness of hrHPV-based screening.


Asunto(s)
Detección Precoz del Cáncer/métodos , Infecciones por Papillomavirus/complicaciones , Neoplasias del Cuello Uterino/diagnóstico , Adulto , Estudios de Cohortes , Femenino , Humanos , Estudios Longitudinales , Tamizaje Masivo , Persona de Mediana Edad , Países Bajos , Estudios Retrospectivos
20.
Clin Infect Dis ; 69(7): 1243-1253, 2019 09 13.
Artículo en Inglés | MEDLINE | ID: mdl-30689772

RESUMEN

We systematically reviewed available evidence from Embase, Medline, and the Cochrane Library on diagnostic accuracy and clinical impact of commercially available rapid (results <3 hours) molecular diagnostics for respiratory viruses as compared to conventional molecular tests. Quality of included studies was assessed using the Quality Assessment of Diagnostic Accuracy Studies criteria for diagnostic test accuracy (DTA) studies, and the Cochrane Risk of Bias Assessment and Risk of Bias in Nonrandomized Studies of Interventions criteria for randomized and observational impact studies, respectively. Sixty-three DTA reports (56 studies) were meta-analyzed with a pooled sensitivity of 90.9% (95% confidence interval [CI], 88.7%-93.1%) and specificity of 96.1% (95% CI, 94.2%-97.9%) for the detection of either influenza virus (n = 29), respiratory syncytial virus (RSV) (n = 1), influenza virus and RSV (n = 19), or a viral panel including influenza virus and RSV (n = 14). The 15 included impact studies (5 randomized) were very heterogeneous and results were therefore inconclusive. However, we suggest that implementation of rapid diagnostics in hospital care settings should be considered.


Asunto(s)
Técnicas de Diagnóstico Molecular , Infecciones del Sistema Respiratorio/diagnóstico , Infecciones del Sistema Respiratorio/virología , Algoritmos , Toma de Decisiones Clínicas , Manejo de la Enfermedad , Humanos , Gripe Humana/diagnóstico , Gripe Humana/virología , Técnicas de Diagnóstico Molecular/métodos , Técnicas de Diagnóstico Molecular/normas , Curva ROC , Reproducibilidad de los Resultados , Infecciones por Virus Sincitial Respiratorio/diagnóstico , Infecciones por Virus Sincitial Respiratorio/virología , Sensibilidad y Especificidad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA