Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Circ Cardiovasc Interv ; 16(11): e013238, 2023 11.
Artículo en Inglés | MEDLINE | ID: mdl-37988439

RESUMEN

BACKGROUND: Coronary accessibility following redo-transcatheter aortic valve replacement (redo-TAVR) is increasingly important, particularly in younger low-risk patients. This study aimed to predict coronary accessibility after simulated Sapien-3 balloon-expandable valve implantation within an Evolut supra-annular, self-expanding valve using pre-TAVR computed tomography (CT) imaging. METHODS: A total of 219 pre-TAVR CT scans from the Evolut Low-Risk CT substudy were analyzed. Virtual Evolut and Sapien-3 valves were sized using CT-based diameters. Two initial Evolut implant depths were analyzed, 3 and 5 mm. Coronary accessibility was evaluated for 2 Sapien-3 in Evolut implant positions: Sapien-3 outflow at Evolut node 4 and Evolut node 5. RESULTS: With a 3-mm initial Evolut implant depth, suitable coronary access was predicted in 84% of patients with the Sapien-3 outflow at Evolut node 4, and in 31% of cases with the Sapien-3 outflow at Evolut node 5 (P<0.001). Coronary accessibility improved with a 5-mm Evolut implant depth: 97% at node 4 and 65% at node 5 (P<0.001). When comparing 3- to 5-mm Evolut implant depth, sinus sequestration was the lowest with Sapien-3 outflow at Evolut node 4 (13% versus 2%; P<0.001), and the highest at Evolut node 5 (61% versus 32%; P<0.001). CONCLUSIONS: Coronary accessibility after Sapien-3 in Evolut redo-TAVR relates to the initial Evolut implant depth, the Sapien-3 outflow position within the Evolut, and the native annular anatomy. This CT-based quantitative analysis may provide useful information to inform and refine individualized preprocedural CT planning of the initial TAVR and guide lifetime management for future coronary access after redo-TAVR. REGISTRATION: URL: https://www.clinicaltrials.gov; Unique identifier: NCT02701283.


Asunto(s)
Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Estenosis de la Válvula Aórtica/cirugía , Estudios de Factibilidad , Resultado del Tratamiento , Tomografía Computarizada por Rayos X , Diseño de Prótesis
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...