Clin Chem Lab Med ; 2024 Jun 17.
Artículo en Inglés | MEDLINE | ID: mdl-38880779

RESUMEN

Point-of-care testing (POCT) is becoming an increasingly popular way to perform laboratory tests closer to the patient. This option has several recognized advantages, such as accessibility, portability, speed, convenience, ease of use, ever-growing test panels, lower cumulative healthcare costs when used within appropriate clinical pathways, better patient empowerment and engagement, and reduction of certain pre-analytical errors, especially those related to specimen transportation. On the other hand, POCT also poses some limitations and risks, namely the risk of lower accuracy and reliability compared to traditional laboratory tests, quality control and connectivity issues, high dependence on operators (with varying levels of expertise or training), challenges related to patient data management, higher costs per individual test, regulatory and compliance issues such as the need for appropriate validation prior to clinical use (especially for rapid diagnostic tests; RDTs), as well as additional preanalytical sources of error that may remain undetected in this type of testing, which is usually based on whole blood samples (i.e., presence of interfering substances, clotting, hemolysis, etc.). There is no doubt that POCT is a breakthrough innovation in laboratory medicine, but the discussion on its appropriate use requires further debate and initiatives. This collective opinion paper, composed of abstracts of the lectures presented at the two-day expert meeting "Point-Of-Care-Testing: State of the Art and Perspective" (Venice, April 4-5, 2024), aims to provide a thoughtful overview of the state-of-the-art in POCT, its current applications, advantages and potential limitations, as well as some interesting reflections on the future perspectives of this particular field of laboratory medicine.

2.
Clin Biochem ; 125: 110727, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38336160

RESUMEN

OBJECTIVES: Healthcare has a considerable environmental impact, yet it has been largely overlooked. Clinical laboratories, in particular, consume significantly more energy and water per unit area compared to standard office buildings. It is crucial to raise awareness among laboratories about the significance of embracing eco-friendly practices. Numerous energy-saving measures do not incur additional costs but necessitate a shift in organizational culture and mindset. DESIGN & METHODS: This paper conducts a cost-benefit analysis of energy consumption at the Laboratory Medicine Unit of University Hospital of Padova, beginning with laboratory refrigerators and freezers. RESULTS: The need to rationalize the existing units, especially the combined refrigerators-freezers, and reorganize the contents of the Ultra-Low Temperature freezers with an energy-saving perspective has emerged. CONCLUSIONS: By implementing these practices, this initiative can gradually expand to encompass more green activities in the future.


Asunto(s)
Servicios de Laboratorio Clínico , Conservación de los Recursos Naturales , Humanos , Laboratorios Clínicos
3.
Clin Chem Lab Med ; 61(4): 688-695, 2023 03 28.
Artículo en Inglés | MEDLINE | ID: mdl-36660807

RESUMEN

In the last few decades, quality in laboratory medicine has evolved in concert with the transformation and the changes (technological, scientific and organizational) in this sector. Laboratory professionals have faced great challenges, at times being overwhelmed, yet also involved in this progress. Worldwide, laboratory professionals and scientific societies involved in laboratory medicine have raised awareness concerning the need to identify new quality assurance tools that are effective in reducing the error rate and enhancing patient safety, in addition to Internal Quality Control (IQC) procedures and the participation in the External Quality Assessment Schemes (EQAS). The use of Quality Indicators (QIs), specifically designed for laboratory medicine are effective in assessing and monitoring all critical events occurring in the different phases of Total Testing Process (TTP), in particular, in the extra-analytical phases. The Model of Quality Indicators (MQI), proposed by the Working Group "Laboratory Errors and Patient Safety" (WG-LEPS) of the International Federation of Clinical Chemistry and Laboratory Medicine (IFCC) and validated by experts in consensus conferences, is an important window of opportunity for the medical laboratory to demonstrate the use of an effective quality assurance tool fit for this purpose. Aim of this paper is to provide an update of the state-of-the-art concerning the most used QIs data collected in 2021 and the Quality Specifications (QSs) proposed for their evaluation. Moreover, a strategy for the future is proposed in order to improve the MQI and encourage its use in medical laboratories throughout the world.


Asunto(s)
Laboratorios , Indicadores de Calidad de la Atención de Salud , Humanos , Seguridad del Paciente , Control de Calidad , Exactitud de los Datos , Técnicas de Laboratorio Clínico
4.
Int J Lab Hematol ; 44(6): 1040-1049, 2022 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-35916349

RESUMEN

INTRODUCTION: Despite the important diagnostic role of peripheral blood morphology, cell classification is subjective. Automated image-processing systems (AIS) provide more accurate and objective morphological evaluation. The aims of this multicenter study were the evaluation of the intra and inter-laboratory variation between different AIS in cell pre-classification and after reclassification, compared with manual optical microscopy, the reference method. METHODS: Six peripheral blood samples were included in this study, for each sample, 70 May-Grunwald and Giemsa stained PB smears were prepared from each specimen and 10 slides were delivered to the seven laboratories involved. Smears were processed by both optical microscopy (OM) and AIS. In addition, the assessment times of both methods were recorded. RESULTS: Within-laboratory Reproducibility ranged between 4.76% and 153.78%; between-laboratory Precision ranged between 2.10% and 82.2%, while Total Imprecision ranged between 5.21% and 20.60%. The relative Bland Altman bias ranged between -0.01% and 20.60%. The mean of assessment times were 326 ± 110 s and 191 ± 68 s for AIS post reclassification and OM, respectively. CONCLUSIONS: AIS can be helpful when the number of cell counted are low and can give advantages in terms of efficiency, objectivity and time saving in the morphological analysis of blood cells. They can also help in the interpretation of some morphological features and can serve as learning and investigation tools.


Asunto(s)
Microscopía , Respeto , Humanos , Microscopía/métodos , Reproducibilidad de los Resultados , Procesamiento de Imagen Asistido por Computador , Células Sanguíneas
5.
Clin Chem Lab Med ; 60(10): 1525-1542, 2022 09 27.
Artículo en Inglés | MEDLINE | ID: mdl-35858238

RESUMEN

Major adverse cardiovascular events are frequently observed in patients undergoing major non-cardiac surgery during the peri-operative period. At this time, the possibility to predict cardiovascular events remains limited, despite the introduction of several algorithms to calculate the risk of adverse events, mainly death and major adverse cardiovascular events (MACE) based on the clinical history, risk factors (sex, age, lipid profile, serum creatinine) and non-invasive cardiac exams (electrocardiogram, echocardiogram, stress tests). The cardiac-specific biomarkers natriuretic peptides (NPs) and cardiac troponins (cTn) have been proposed as additional tools for risk prediction in the peri-operative period, particularly for the identification of myocardial injury in patients undergoing major non-cardiac surgery. The prognostic information from the measurement of BNP/NT-proBNP and hs-cTn is independent and complementary to other important indicators of risk, also including ECG and imaging techniques. Elevated levels of cardiac-specific biomarkers before surgery are associated with a markedly higher risk of MACE during the peri-operative period. BNP/NT-proBNP and hs-cTn should be measured in all patients during the clinical evaluation before surgery, particularly during intermediate- or high-risk surgery, in patients aged >65 years and/or with comorbidities. Several questions remain to be assessed in dedicated clinical studies, such as how to optimize the management of patients with raised cardiac specific biomarkers before surgery, and whether a strategy based on biomarker measurement improves patient outcomes and is cost-effective.


Asunto(s)
Enfermedades Cardiovasculares , Biomarcadores , Factores de Riesgo de Enfermedad Cardiaca , Humanos , Péptido Natriurético Encefálico , Fragmentos de Péptidos , Pronóstico , Medición de Riesgo , Factores de Riesgo
6.
Clin Chem Lab Med ; 60(2): 169-182, 2022 01 27.
Artículo en Inglés | MEDLINE | ID: mdl-34927403

RESUMEN

Serial measurements of cardiac troponin are recommended by international guidelines to diagnose myocardial infarction (MI) since 2000. However, some relevant differences exist between the three different international guidelines published between 2020 and 2021 for the management of patients with chest pain and no ST-segment elevation. In particular, there is no agreement on the cut-offs or absolute change values to diagnose non-ST-segment elevation MI (NSTEMI). Other controversial issues concern the diagnostic accuracy and cost-effectiveness of cut-off values for the most rapid algorithms (0 h/1 h or 0 h/2 h) to rule-in and rule-out NSTEMI. Finally, another important point is the possible differences between demographic and clinical characteristics of patients enrolled in multicenter trials compared to those routinely admitted to the Emergency Department in Italy. The Study Group of Cardiac Biomarkers, supported by the Italian Scientific Societies Società Italiana di Biochimica Clinica, Italian Society of the European Ligand Assay Society, and Società Italiana di Patolgia Clinica e Medicina di Laboratorio decided to revise the document previously published in 2013 about the management of patients with suspected NSTEMI, and to provide some suggestions for the use of these biomarkers in clinical practice, with a particular focus on the Italian setting.


Asunto(s)
Infarto del Miocardio , Infarto del Miocardio sin Elevación del ST , Algoritmos , Biomarcadores , Servicio de Urgencia en Hospital , Humanos , Infarto del Miocardio/diagnóstico , Infarto del Miocardio sin Elevación del ST/diagnóstico , Troponina
7.
Clin Chem Lab Med ; 59(11): 1878-1884, 2021 10 26.
Artículo en Inglés | MEDLINE | ID: mdl-34348424

RESUMEN

OBJECTIVES: Numerous analytical systems, rapidly made available on the market throughout the SARS-CoV-2 pandemic, aim to detect COVID-19, and to continuously update and improve the same systems. Medical laboratory professionals have also developed in-house analytical procedures in order to satisfy the enormous volume of requests for tests. These developments have highlighted the need control the analytical procedures used in order to guarantee patient safety. The External Quality Assessment (EQA) Scheme, an important quality assurance tool, aims to guarantee high standard performance for laboratory and analytical procedures. The aim of the present study was to report on the results collected in an experimental EQA scheme for the serological diagnosis of SARS-CoV-2. METHODS: All qualitative results collected in the different EQA surveys were summarized in order to identify the percentage of laboratory results in relation to typology of antibodies, results and samples. RESULTS: A total of 4,867 data sets were collected. The analysis of EQA data made, demonstrates a better agreement among laboratories results for total Ig than single immunoglobulins (IgG, IgM, IgA) in the case samples positive for SARS-CoV-2, and a wide divergence between IgM results for positive samples (only 34.9% were correct). Results for negative controls and specificity controls demonstrated a better overall agreement than results for positive samples. CONCLUSIONS: Working in collaboration with the IVD manufacturers, laboratory professionals must strive to achieve harmonization of results, and to develop well-defined protocols complying with the ISO 15189 requirements.


Asunto(s)
Anticuerpos Antivirales/inmunología , COVID-19/diagnóstico , SARS-CoV-2/inmunología , Pruebas Serológicas/métodos , Anticuerpos Antivirales/sangre , COVID-19/inmunología , Humanos , Inmunoglobulina A/sangre , Inmunoglobulina A/metabolismo , Inmunoglobulina G/sangre , Inmunoglobulina G/metabolismo , Inmunoglobulina M/sangre , Inmunoglobulina M/metabolismo , Proyectos Piloto , Garantía de la Calidad de Atención de Salud , Estudios Retrospectivos , Sensibilidad y Especificidad , Índice de Severidad de la Enfermedad
8.
Clin Chem Lab Med ; 59(8): 1444-1452, 2021 07 27.
Artículo en Inglés | MEDLINE | ID: mdl-33855843

RESUMEN

OBJECTIVES: SARS-CoV-2 serology presents an important role in several aspects of COVID-19 pandemic. Immunoassays performances have to be accurately evaluated and correlated with neutralizing antibodies. We investigated the analytical and clinical performances of a SARS-CoV-2 RBD IgG assay, automated on a high throughput platform, and the correlation of the antibodies (Ab) levels with the plaque reduction neutralization (PRNT50) Ab titers. METHODS: A series of 546 samples were evaluated by SARS-CoV-2 RBD IgG assay (Snibe diagnostics), including 171 negative and 168 positive SARS-CoV-2 subjects and a further group of 207 subjects of the COVID-19 family clusters follow-up cohort. RESULTS: Assay imprecision ranged from 3.98 to 12.18% being satisfactory at low and medium levels; linearity was excellent in all the measurement range. Considering specimens collected after 14 days post symptoms onset, overall sensitivity and specificity were 99.0 and 92.5%, respectively. A total of 281 leftover samples results of the PRNT50 test were available. An elevated correlation was obtained between the SARS-CoV-2 RBD IgG assay and the PRNT50 titer at univariate (ρ=0.689) and multivariate (ρ=0.712) analyses. CONCLUSIONS: SARS-CoV-2 S-RBD IgG assay shows satisfactory analytical and clinical performances, and a strong correlation with sera neutralizing activity.


Asunto(s)
Anticuerpos Neutralizantes/inmunología , Inmunoglobulina G/inmunología , Pruebas de Neutralización/métodos , SARS-CoV-2/metabolismo , Glicoproteína de la Espiga del Coronavirus/inmunología , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Anticuerpos Neutralizantes/sangre , Anticuerpos Antivirales/sangre , COVID-19/patología , COVID-19/virología , Niño , Femenino , Humanos , Inmunoensayo/métodos , Inmunoglobulina G/sangre , Masculino , Persona de Mediana Edad , Subunidades de Proteína/inmunología , SARS-CoV-2/aislamiento & purificación , Índice de Severidad de la Enfermedad , Adulto Joven
9.
Clin Chem Lab Med ; 59(3): 505-512, 2021 02 23.
Artículo en Inglés | MEDLINE | ID: mdl-33554548

RESUMEN

European Union (EU) Directive 2013/55/EC (The Recognition of Professional Qualifications) allows Member States to decide on a common set of minimum knowledge, skills and competences that are needed to pursue a given profession through a Common Training Framework. To be adopted the framework must combine the knowledge, skills and competences of at least one third of the Member States. Professionals who have gained their qualifications under a Common Training Framework will be able to have these recognised automatically within the Union. The backbone of the European Federation of Clinical Chemistry and Laboratory Medicine's (EFLM) proposed Common Training Framework for non-medical Specialists in Laboratory Medicine is outlined here. It is based on an Equivalence of Standards in education, training, qualifications, knowledge, skills, competences and the professional conduct associated with specialist practice. In proposing the recognition of specialist practice EFLM has identified 15 EU Member States able to meet Equivalence and in whom the profession and/or its training is regulated (an additional EU Commission requirement). The framework supports and contributes to the Directive's enabling goals for increasing professional mobility, safeguarding consumers and ensuring a more equitable distribution of skills and expertise across the Member States. It represents EFLM's position statement and provides a template for professional societies and/or competent authorities to engage with the EU Commission.


Asunto(s)
Laboratorios , Química Clínica , Curriculum , Unión Europea , Humanos , Especialización
11.
Clin Chem Lab Med ; 59(3): 513-521, 2021 02 23.
Artículo en Inglés | MEDLINE | ID: mdl-32441665

RESUMEN

Important advances achieved in pharmacological cancer treatment have led progressively to a reduction in mortality from many forms of cancer, and increasing numbers of previously incurable patients can now hope to become cancer-free. Yet, to achieve these improved outcomes a high price has been paid in terms of untoward side effects associated with treatment, cardio-toxicity in particular. Several recent studies have reported that cardiac troponin assay using high-sensitivity methods (hs-cTn) can enable the early detection of myocardial injury related to chemotherapy or abuse of drugs that are potentially cardiotoxic. Several authors have recently suggested that changes in hs-cTn values enable the early diagnosis of cardiac injury from chemotherapy, thus potentially benefitting cancer patients with increased troponin values by initiating early cardioprotective therapy. However, large randomised clinical trials are needed in order to evaluate the cost/benefit ratio of standardised protocols for the early detection of cardiotoxicity using the hs-cTn assay in patients treated with chemotherapy.


Asunto(s)
Lesiones Cardíacas , Bioensayo , Biomarcadores , Detección Precoz del Cáncer , Humanos , Troponina I , Troponina T
12.
EBioMedicine ; 62: 103101, 2020 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-33160207

RESUMEN

BACKGROUND: Reliable high-throughput serological assays for SARS-CoV-2 antibodies are urgently needed for the effective containment of the COVID-19 pandemic, as it is of crucial importance to understand the strength and duration of immunity after infection, and to make informed decisions concerning the activation or discontinuation of physical distancing restrictions. METHODS: In 184 serum samples from 130 COVID-19 patients and 54 SARS-CoV-2 negative subjects, the analytical and clinical performances of four commercially available chemiluminescent assays (Abbott SARS-Cov-2 IgG, Roche Elecsys anti-SARS-CoV-2, Ortho SARS-CoV-2 total and IgG) and one enzyme-linked immunosorbent assay (Diesse ENZY-WELL SARS-CoV-2 IgG) were evaluated and compared with the neutralization activity achieved using the plaque reduction neutralization test (PRNT). FINDINGS: Precision results ranged from 0.9% to 11.8% for all assays. Elecsys anti-SARS-CoV-2 demonstrated linearity of results at concentrations within the cut-off value. Overall, sensitivity ranged from 78.5 to 87.7%, and specificity, from 97.6 to 100%. On limiting the analysis to samples collected 12 days after onset of symptoms, the sensitivity of all assays increased, the highest value (95.2%) being obtained with VITRO Anti-SARS-CoV-2 Total and Architect SARS-CoV-2 IgG. The strongest PRNT50 correlation with antibody levels was obtained with ENZY-Well SARS-CoV-2 IgG (R2adj = 0.569). INTERPRETATION: The results confirmed that all immunoassays had an excellent specificity, whereas sensitivity varied across immunoassays, depending strongly on the time interval between symptoms onset and sample collection. Further studies should be conducted to achieve a stronger correlation between antibody measurement and PRNT50 in order to obtain useful information for providing a better management of COVID-19 patients, effective passive antibody therapy, and developing a vaccine against the SARS-CoV-2 virus. FUNDING: None.


Asunto(s)
Anticuerpos Neutralizantes , Anticuerpos Antivirales , Prueba Serológica para COVID-19 , COVID-19 , SARS-CoV-2 , Adulto , Anciano , Anciano de 80 o más Años , Anticuerpos Neutralizantes/sangre , Anticuerpos Neutralizantes/inmunología , Anticuerpos Antivirales/sangre , Anticuerpos Antivirales/inmunología , COVID-19/sangre , COVID-19/inmunología , Femenino , Humanos , Masculino , Persona de Mediana Edad , SARS-CoV-2/inmunología , SARS-CoV-2/metabolismo
13.
Haemophilia ; 26(6): 937-945, 2020 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-33094880

RESUMEN

INTRODUCTION: The factor VIII (FVIII)-mimetic bispecific monoclonal antibody, emicizumab, previously approved for prophylaxis in haemophilia A with inhibitors, has been recently licensed in several countries also in patients with severe haemophilia A (PWSHA) without inhibitors. The introduction of this innovative agent requires the development of specific pathways at Haemophilia Treatment Centres (HTC), particularly regarding laboratory testing and treatment of breakthrough bleeds and invasive procedures/surgeries, even more critical when patients are managed by non-specialist professionals. Limited literature data and clinical experience in PWSHA without inhibitors on emicizumab are currently available. AIM: To promote awareness and overcome these challenges, the Italian Association of Haemophilia Centres (AICE) issued a guidance on the management of PWSHA without inhibitors on emicizumab prophylaxis, focused on emergency and shared with other National Scientific Societies in the field. METHODS: The document, drafted by an AICE expert panel and approved through online consultation, was further revised by a multidisciplinary working group, including members of 5 haemostasis, laboratory and emergency scientific societies. The final version was approved by the Council of each society. RESULTS: General recommendations about use of FVIII concentrates for the treatment of bleeding or haemostatic coverage of invasive procedures/surgeries and laboratory monitoring in PWSHA without inhibitors on emicizumab are provided. Specific issues of the management in the emergency room are focused, highlighting the need for direct involvement or formalized supervision by specialist HTC physicians. CONCLUSIONS: This guidance provides a reference pathway to be implemented in the different healthcare organizations, especially for the challenging emergency management in this setting.


Asunto(s)
Anticuerpos Biespecíficos/uso terapéutico , Anticuerpos Monoclonales Humanizados/uso terapéutico , Hemofilia A/tratamiento farmacológico , Anticuerpos Biespecíficos/farmacología , Anticuerpos Monoclonales Humanizados/farmacología , Humanos
15.
Clin Chem Lab Med ; 59(1): 79-90, 2020 07 21.
Artículo en Inglés | MEDLINE | ID: mdl-32692693

RESUMEN

In recent years, the formulation of some immunoassays with high-sensitivity analytical performance allowed the accurate measurement of cardiac troponin I (cTnI) and T (cTnT) levels in reference subjects. Several studies have demonstrated the association between the risk of major cardiovascular events and cardiac troponin concentrations even for biomarker values within the reference intervals. High-sensitivity cTnI and cTnT methods (hs-cTn) enable to monitor myocardial renewal and remodelling, and to promptly identify patients at highest risk ofheart failure. An early and effective treatment of individuals at higher cardiovascular risk may revert the initial myocardial remodelling and slow down heart failure progression. Specific clinical trials should be carried out to demonstrate the efficacy and efficiency of the general population screening by means of cost-benefit analysis, in order to better identify individuals at higher risk for heart failure (HF) progression with hs-cTn methods.


Asunto(s)
Enfermedades Cardiovasculares/diagnóstico , Péptidos Natriuréticos/sangre , Troponina I/sangre , Troponina T/sangre , Biomarcadores/sangre , Enfermedades Cardiovasculares/sangre , Factores de Riesgo de Enfermedad Cardiaca , Humanos , Pronóstico , Medición de Riesgo
17.
Clin Chim Acta ; 509: 1-7, 2020 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-32485157

RESUMEN

BACKGROUND: The evaluation of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) specific antibody (Ab) assay performances is of the utmost importance in establishing and monitoring virus spread in the community. In this study focusing on IgG antibodies, we compare reliability of three chemiluminescent (CLIA) and two enzyme linked immunosorbent (ELISA) assays. METHODS: Sera from a total of 271 subjects, including 64 reverse transcription-polymerase chain reaction (RT-PCR) confirmed SARS-CoV-2 patients were tested for specific Ab using Maglumi (Snibe), Liaison (Diasorin), iFlash (Yhlo), Euroimmun (Medizinische Labordiagnostika AG) and Wantai (Wantai Biological Pharmacy) assays. Diagnostic sensitivity and specificity, positive and negative likelihood ratios were evaluated using manufacturers' and optimized thresholds. RESULTS: Optimized thresholds (Maglumi 2 kAU/L, Liaison 6.2 kAU/L and iFlash 15.0 kAU/L) allowed us to achieve a negative likelihood ratio and an accuracy of: 0.06 and 93.5% for Maglumi; 0.03 and 93.1% for Liaison; 0.03 and 91% for iFlash. Diagnostic sensitivities and specificities were above 93.8% and 85.9%, respectively for all CLIA assays. Overall agreement was 90.3% (Cohen's kappa = 0.805 and SE = 0.041) for CLIA, and 98.4% (Cohen's kappa = 0.962 and SE = 0.126) for ELISA. CONCLUSIONS: The results obtained indicate that, for CLIA assays, it might be possible to define thresholds that improve the negative likelihood ratio. Thus, a negative test result enables the identification of subjects at risk of being infected, who should then be closely monitored over time with a view to preventing further viral spread. Redefined thresholds, in addition, improved the overall inter-assay agreement, paving the way to a better harmonization of serologic tests.


Asunto(s)
Betacoronavirus , Infecciones por Coronavirus/sangre , Infecciones por Coronavirus/diagnóstico , Neumonía Viral/sangre , Neumonía Viral/diagnóstico , Reacción en Cadena de la Polimerasa de Transcriptasa Inversa/normas , Pruebas Serológicas/normas , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Betacoronavirus/aislamiento & purificación , COVID-19 , Niño , Ensayo de Inmunoadsorción Enzimática/métodos , Ensayo de Inmunoadsorción Enzimática/normas , Femenino , Humanos , Masculino , Persona de Mediana Edad , Pandemias , Reproducibilidad de los Resultados , Reacción en Cadena de la Polimerasa de Transcriptasa Inversa/métodos , SARS-CoV-2 , Pruebas Serológicas/métodos , Adulto Joven
18.
J Clin Lab Anal ; 34(8): e23327, 2020 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-32342567

RESUMEN

OBJECTIVES: The aim of this study was to assess the commutability of three external quality assessment (EQA) materials for point-of-care (POC) glucose testing using two approaches, to identify suitable EQA materials to evaluate and monitor the quality of POC testing. METHODS: Commercial control materials (CCMs), pooled human serum samples (PHSs), and homemade human whole-blood samples (HWBs) were measured along with 33 individual clinical samples using five POC instruments and a Hitachi 7600 analyzer. Data were analyzed by Deming regression analysis with a 95% prediction interval as described in Clinical and Laboratory Standards Institute (CLSI) EP30-A, and by difference in bias analysis as described by the International Federation of Clinical Chemistry (IFCC) Working Group on Commutability. RESULTS: Using the CLSI approach, HWBs, CCMs, and PHSs were commutable with five, one, and two instruments, respectively. With the IFCC approach, HWBs were commutable with two instruments, while CCMs and PHSs were largely inconclusive or non-commutable on five instruments. CONCLUSIONS: HWBs were commutable on all instruments by the CLSI approach and may be a suitable EQA material for POC testing. Although some results differed between the IFCC and CLSI approaches, both indicated that HWBs were far superior to CCMs and PHSs in commutability.


Asunto(s)
Análisis Químico de la Sangre/normas , Glucemia/análisis , Laboratorios , Pruebas en el Punto de Atención/normas , Control de Calidad , Humanos , Laboratorios/organización & administración , Laboratorios/normas , Reproducibilidad de los Resultados
19.
Clin Chim Acta ; 507: 164-166, 2020 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-32343948

RESUMEN

Validation studies of serological antibody tests must be properly designed for clinical, epidemiological and Public Health objectives such as confirmation of suspected COVID-19 cases, certification of seroconversion after infection, and epidemiological surveillance. We evaluated the kinetics of IgM, IgA and IgG SARS-CoV-2 antibodies in COVID-19 patients with confirmed (rRT-PCR) infection. We found that the IgA response appears and grows early, peaks at week 3, and it is stronger and more persistent than the IgM response. Further longitudinal investigations of virus-specific antibodies functions and of their protective efficacy over time are needed.


Asunto(s)
Anticuerpos Antivirales/sangre , Betacoronavirus/aislamiento & purificación , Infecciones por Coronavirus/sangre , Infecciones por Coronavirus/diagnóstico , Glicoproteínas/sangre , Inmunoglobulina A/sangre , Neumonía Viral/sangre , Neumonía Viral/diagnóstico , Adulto , Anciano , Anciano de 80 o más Años , COVID-19 , Femenino , Humanos , Estudios Longitudinales , Mediciones Luminiscentes/métodos , Masculino , Persona de Mediana Edad , Pandemias , Reacción en Cadena en Tiempo Real de la Polimerasa/métodos , SARS-CoV-2 , Adulto Joven
20.
Clin Chem Lab Med ; 58(7): 1081-1088, 2020 06 25.
Artículo en Inglés | MEDLINE | ID: mdl-32301749

RESUMEN

Background Coronavirus disease 2019, abbreviated to COVID-19, represents an emerging health threat worldwide as, after initial reports in China, it has continued to spread rapidly. The clinical spectrum of the disease varies from mild to severe acute respiratory distress syndrome (ARDS). Moreover, many patients can be asymptomatic, thus increasing the uncertainty of the diagnostic work-up. Laboratory tests play a pivotal role in the diagnosis and management of COVID-19, the current gold standard being real-time reverse transcription polymerase chain reaction (rRT-PCR) on respiratory tract specimens. However, the diagnostic accuracy of rRT-PCR depends on many pre-analytical and analytical variables. The measurement of specific COVID-19 antibodies (both IgG and IgM) should serve as an additional, non-invasive tool for disease detection and management. Methods The imprecision of the MAGLUMI™ 2000 Plus 2019-nCov IgM and IgG assays (Snibe, Shenzhen, China) was assessed by adopting the Clinical and Laboratory Standards Institute (CLSI) EP15-A3 protocol. Linearity of dilution and recovery was evaluated by means of mixes of high-level pools and low-level pools of serum samples. Immunoglobulin time kinetics were evaluated using a series of serum samples, repeatedly collected from COVID-19-positive patients at different times, from <5 days up to 26-30 days. Results Findings at the analytical validation of the assay carried out according to the CLSI EP15-A3 guideline demonstrated that imprecision and repeatability were acceptable (repeatability was <4% and <6% for IgM and IgG, respectively, whilst intermediate imprecision was <6%). In addition, results of dilution and recovery studies were satisfactory. The kinetics of COVID-19 antibodies confirmed previously reported findings, showing a rapid increase of both IgM and IgG after 6-7 days from the symptom onset. IgG had 100% sensitivity on day 12, whilst 88% was the higher positive rate achieved for IgM after the same time interval. Conclusions The findings of this study demonstrate the validity of the MAGLUMI 2000 Plus CLIA assay for the measurement of specific IgM and IgG in sera of COVID-19 patients, and for obtaining valuable data on the kinetics of both (IgM and IgG) COVID-19 antibodies. These data represent a pre-requisite for the appropriate utilization of specific antibodies for the diagnosis and management of COVID-19 patients.


Asunto(s)
Betacoronavirus/inmunología , Infecciones por Coronavirus/inmunología , Técnicas para Inmunoenzimas/métodos , Neumonía Viral/inmunología , Anticuerpos Antivirales/sangre , COVID-19 , China , Técnicas de Laboratorio Clínico/métodos , Humanos , Inmunoglobulina G/sangre , Inmunoglobulina G/inmunología , Inmunoglobulina M/sangre , Inmunoglobulina M/inmunología , Cinética , Mediciones Luminiscentes/métodos , Pandemias , Reacción en Cadena en Tiempo Real de la Polimerasa , SARS-CoV-2
SELECCIÓN DE REFERENCIAS