Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
2.
Arthritis Care Res (Hoboken) ; 74(12): 2005-2012, 2022 12.
Artículo en Inglés | MEDLINE | ID: mdl-34137211

RESUMEN

OBJECTIVE: To standardize and assess the reliability of ultrasonographic assessment of inflammatory and structural lesions in patients with hand osteoarthritis (OA). METHODS: The Outcome Measures in Rheumatology Ultrasound Working Group selected synovial hypertrophy (SH), joint effusion (JE), and power Doppler (PD) signals as the main inflammatory lesions in hand OA, and suggested osteophytes in the scapho-trapezio-trapezoid (STT) and cartilage defects in the proximal interphalangeal (PIP) joints as novel additions to previous structural scoring systems. A complementary imaging atlas provided detailed examples of the scores. A reliability exercise of static images was performed for the inflammatory features, followed by a patient-based exercise with 6 sonographers testing inflammatory and structural features in 12 hand OA patients. We used Cohen's kappa for intrareader and Light's kappa for interreader reliability for all features except PD, in which prevalence-adjusted bias-adjusted kappa (PABAK) was applied. Percentage agreement was also assessed. RESULTS: The web-based reliability exercise demonstrated substantial intra- and interreader reliability for all inflammatory features (κ > 0.64). In the patient-based exercise, intra- and interreader reliability, respectively, varied: SH κ = 0.73 and 0.45; JE κ = 0.70 and 0.55; PD PABAK = 0.90 and 0.88; PIP joint cartilage κ = 0.56 and 0.45; and STT osteophytes κ = 0.62 and 0.36. Percentage close agreement was high for all features (>85%). CONCLUSION: With ultrasound, substantial to excellent intrareader reliability was found for inflammatory features of hand OA. Interreader reliability was moderate, but overall high close agreement between readers suggests that better reliability is achievable after further training. Assessment of osteophytes in the STT joint and cartilage in the PIP joints achieved less reliability and the latter is not endorsed.


Asunto(s)
Osteoartritis , Osteofito , Reumatología , Sinovitis , Humanos , Osteofito/diagnóstico por imagen , Reproducibilidad de los Resultados , Osteoartritis/diagnóstico por imagen , Ultrasonografía/métodos , Evaluación de Resultado en la Atención de Salud , Variaciones Dependientes del Observador
3.
Semin Arthritis Rheum ; 51(3): 661-676, 2021 06.
Artículo en Inglés | MEDLINE | ID: mdl-33386164

RESUMEN

AIMS: To analyze whether there is sufficient data from published literature to demonstrate that ultrasound, including elastography, present good metric properties (truth, discrimination and feasibility) in autoimmune myositis (AIM). METHODS: A population, intervention, comparator and outcome-structured (PICO) search was performed in Medline, Cochrane Library and Embase database from 01/01/1973 to 08/05/2019. The inclusion criteria required original research involving adult humans, reported in English, assessing ultrasound and elastography in patients with an AIM. Conference abstracts and computer-assisted diagnostics that focused on technique and not ultrasound domains were excluded. RESULTS: Approximately 2670 articles were identified. Forty-one full-text articles were included in the final analysis. There were 551 AIM patients studied. Eighteen studies (43.9%) had a control group, of which 15 (63.3%) were healthy controls. The age of participants (including controls) varied from 18 to 86 years, and most were females (59%). Diagnosis of AIM was largely biopsy-proven, although some were derived through clinical presentation, positive clinical imaging (ultrasound or otherwise) and/or electromyography and steroid responsiveness. The features examined with ultrasound in the 41 included articles consisted of: muscle echogenicity, bulk, atrophy, architecture, power Doppler, perfusion characteristics, shear wave modulus, shear wave velocity, elasticity index and fasciculations. Twelve studies (29.2%) used quantitative methods to assess these characteristics, whilst others used semi-quantitative, dichotomous/binary and descriptive scoring systems. Criterion validity was met in 14 studies (12/14, 85.7%) and construct validity in 22 studies (22/25, 88.0%). Most published articles reported Level 3b to Level 5 evidence with varying degrees of bias. There was only one longitudinal study examining discrimination. Reliability and feasibility were under-reported. CONCLUSION: This is the first systematic review studying the utility of ultrasound, including elastography, in AIM. There is some evidence for criterion and construct validity, suggesting that ultrasound may be a promising outcome measurement instrument in AIM. Agreement on the standardization of acquisition, and the definitions of target domains, is required. Additionally, further validation studies are required to determine discrimination, reliability and feasibility.


Asunto(s)
Diagnóstico por Imagen de Elasticidad , Miositis , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Estudios Longitudinales , Persona de Mediana Edad , Miositis/diagnóstico por imagen , Reproducibilidad de los Resultados , Ultrasonografía , Adulto Joven
4.
Semin Arthritis Rheum ; 51(3): 644-649, 2021 06.
Artículo en Inglés | MEDLINE | ID: mdl-33468347

RESUMEN

OBJECTIVE: This study aimed to develop (1) a new ultrasound definition for aggregates and (2) a semi-quantitative ultrasound scoring system (0-3) for tophus, double contour and aggregates. Furthermore, the intra- and inter-reader reliabilities of both the re-defined aggregates and the semi-quantitative scoring system were assessed using static image exercises. METHODS: Thirty-seven rheumatologists were invited. A Delphi process was used for re-defining aggregates and for selecting a semi-quantitative scoring system with >75% agreement obligate for reaching consensus. Subsequently, a web-based exercise on static ultrasound images was conducted in order to assess the reliability of both the re-defined aggregates and the semi-quantitative scoring system. RESULTS: Twenty rheumatologists contributed to all rounds of the Delphi and image exercises. A consensual re-definition of aggregates was obtained after three Delphi rounds but needed an overarching principle for scoring aggregates in patients. A consensus-based semi-quantitative ultrasound scoring system for gout lesions was developed after two Delphi rounds. The re-definition of aggregates showed good intra- and inter-reader reliability (κ-values 0.71 and 0.61). The reliabilities of the scoring system were good for all lesions with slightly higher intra-reader (κ-values 0.74-0.80) than inter-reader reliabilities (κ-values 0.61-0.67). CONCLUSION: A re-definition of aggregates was obtained with a good reliability when assessing static images. The first consensus-based semi-quantitative ultrasound scoring system for gout-specific lesions was developed with good inter- and intra-reader reliability for all lesions when tested in static images. The next step is to assess the reliabilities when scoring lesions in patients.


Asunto(s)
Gota , Consenso , Ejercicio Físico , Gota/diagnóstico por imagen , Humanos , Variaciones Dependientes del Observador , Reproducibilidad de los Resultados , Ultrasonografía
5.
Immunol Res ; 65(3): 681-686, 2017 06.
Artículo en Inglés | MEDLINE | ID: mdl-28101810

RESUMEN

Contrasting results have been reported about the prevalence of thyroid autoimmunity (AT) and dysfunction (TD) in patients with psoriatic arthritis (PsA). In this study, we pointed to evaluate the incidence of new cases of clinical and subclinical TD in a broad group of patients with PsA versus a control group, matched by age and gender belonging to the same geographic area. PsA patients with TD were excluded firstly, and new cases of thyroid disorders were evaluated in 97 PsA patients and 97 matched controls, who had comparable iodine intake (median follow-up of 74 months in PsA versus 92 in controls). A raised rate of new cases of hypothyroidism, TD, positive antithyroid peroxidase (AbTPO) antibodies, and appearance of a small hypoechoic thyroid pattern in PsA, especially in female gender, compared to controls has been evidenced. Risk factors in female gender for the development of TD are thyroid-stimulating hormone (TSH) within the normal range but at the higher limit, positive AbTPO, and small thyroid volume. To sum up, thyroid function follow-up and suitable treatments should be performed regularly in female patients at high risk (TSH within the normal range but at the higher limit, positive AbTPO, hypoechoic and small thyroid).


Asunto(s)
Artritis Psoriásica/epidemiología , Yoduro Peroxidasa/inmunología , Glándula Tiroides/patología , Tiroiditis Autoinmune/epidemiología , Adulto , Anciano , Autoanticuerpos/sangre , Femenino , Estudios de Seguimiento , Humanos , Incidencia , Yodo/metabolismo , Italia/epidemiología , Estudios Longitudinales , Masculino , Persona de Mediana Edad , Factores de Riesgo , Tirotropina/metabolismo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...