Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 70
Filtrar
1.
Spine Deform ; 2024 Jun 07.
Artículo en Inglés | MEDLINE | ID: mdl-38849690

RESUMEN

PURPOSE: The ring apophysis is a secondary ossification center on both sides of each vertebral body, to which the annulus of the intervertebral disc inserts. Recently, its pattern of ossification and fusion to the vertebral body was described for the normal growing spine. The aim of the present study was to investigate the ossification and fusion of the ring apophysis in patients with adolescent idiopathic scoliosis (AIS) and compare it to the normal growing population. METHODS: Ring apophysis maturation along the entire thoracic and lumbar spine was analyzed on CT scans of 99 female, pre-operative AIS patients and compared to 134 CT scans of non-scoliotic girls, aged 12 to 20. RESULTS: The ring apophysis maturation in AIS patients was delayed at all spinal levels in AIS patients compared to non-scoliotic controls. Ossification starts at T4-T11 at age 12, followed by T1-T5 and L3-S1 at age 15. The fusion process in AIS patients continues longer in the midthoracic region as compared to the other regions and as compared to non-scoliotic controls, with many incomplete fusions still at age 20. CONCLUSION: The ring apophysis maturation in AIS is delayed compared to that in the normal population and lasts longer in the mid/low thoracic spine. Delayed maturation of the spine's most important stabilizer, while the body's dimensions continue to increase, could be part of the patho-mechanism of AIS.

2.
Eur J Radiol ; 177: 111542, 2024 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-38861906

RESUMEN

INTRODUCTION: Visualization of scoliosis typically requires ionizing radiation (radiography and CT) to visualize bony anatomy. MRI is often additionally performed to screen for neural axis abnormalities. We propose a 14-minutes radiation-free scoliosis-specific MRI protocol, which combines MRI and MRI-based synthetic CT images to visualize soft and osseous structures in one examination. We assess the ability of the protocol to visualize landmarks needed to detect 3D patho-anatomical changes, screen for neural axis abnormalities, and perform surgical planning and navigation. METHODS: 18 adult volunteers were scanned on 1.5 T MR-scanner using 3D T2-weighted and synthetic CT sequences. A predefined checklist of relevant landmarks was used for the parameter assessment by three readers. Parameters included Cobb angles, rotation, torsion, segmental height, area and centroids of Nucleus Pulposus and Intervertebral Disc. Precision, reliability and agreement between the readers measurements were evaluated. RESULTS: 91 % of Likert-based questions scored ≥ 4, indicating moderate to high confidence. Precision of 3D dot positioning was 1.0 mm. Precision of angle measurement was 0.6° (ICC 0.98). Precision of vertebral and IVD height measurements was 0.4 mm (ICC 0.99). Precision of area measurement for NP was 8 mm2 (ICC 0.55) and for IVD 18 mm2 (ICC 0.62) for IVD. Precision of centroid measurement for NP was 1.3 mm (ICC 0.88-0.92) and for IVD 1.1 mm (ICC 0.88-91). CONCLUSIONS: The proposed MRI protocol with synthetic CT reconstructions, has high precision, reliability and agreement between the readers for multiple scoliosis-specific measurements. It can be used to study scoliosis etiopathogenesis and to assess 3D spinal morphology.

3.
J Orthop Res ; 42(4): 843-854, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-37807082

RESUMEN

This study aims at assessing approaches for generating high-resolution magnetic resonance imaging- (MRI-) based synthetic computed tomography (sCT) images suitable for orthopedic care using a deep learning model trained on low-resolution computed tomography (CT) data. To that end, paired MRI and CT data of three anatomical regions were used: high-resolution knee and ankle data, and low-resolution hip data. Four experiments were conducted to investigate the impact of low-resolution training CT data on sCT generation and to find ways to train models on low-resolution data while providing high-resolution sCT images. Experiments included resampling of the training data or augmentation of the low-resolution data with high-resolution data. Training sCT generation models using low-resolution CT data resulted in blurry sCT images. By resampling the MRI/CT pairs before the training, models generated sharper images, presumably through an increase in the MRI/CT mutual information. Alternatively, augmenting the low-resolution with high-resolution data improved sCT in terms of mean absolute error proportionally to the amount of high-resolution data. Overall, the morphological accuracy was satisfactory as assessed by an average intermodal distance between joint centers ranging from 0.7 to 1.2 mm and by an average intermodal root-mean-squared distances between bone surfaces under 0.7 mm. Average dice scores ranged from 79.8% to 87.3% for bony structures. To conclude, this paper proposed approaches to generate high-resolution sCT suitable for orthopedic care using low-resolution data. This can generalize the use of sCT for imaging the musculoskeletal system, paving the way for an MR-only imaging with simplified logistics and no ionizing radiation.


Asunto(s)
Planificación de la Radioterapia Asistida por Computador , Tomografía Computarizada por Rayos X , Planificación de la Radioterapia Asistida por Computador/métodos , Tomografía Computarizada por Rayos X/métodos , Imagen por Resonancia Magnética/métodos , Huesos , Extremidad Inferior , Procesamiento de Imagen Asistido por Computador/métodos
5.
Front Bioeng Biotechnol ; 11: 1244291, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37731762

RESUMEN

The generation of subject-specific finite element models of the spine is generally a time-consuming process based on computed tomography (CT) images, where scanning exposes subjects to harmful radiation. In this study, a method is presented for the automatic generation of spine finite element models using images from a single magnetic resonance (MR) sequence. The thoracic and lumbar spine of eight adult volunteers was imaged using a 3D multi-echo-gradient-echo sagittal MR sequence. A deep-learning method was used to generate synthetic CT images from the MR images. A pre-trained deep-learning network was used for the automatic segmentation of vertebrae from the synthetic CT images. Another deep-learning network was trained for the automatic segmentation of intervertebral discs from the MR images. The automatic segmentations were validated against manual segmentations for two subjects, one with scoliosis, and another with a spine implant. A template mesh of the spine was registered to the segmentations in three steps using a Bayesian coherent point drift algorithm. First, rigid registration was applied on the complete spine. Second, non-rigid registration was used for the individual discs and vertebrae. Third, the complete spine was non-rigidly registered to the individually registered discs and vertebrae. Comparison of the automatic and manual segmentations led to dice-scores of 0.93-0.96 for all vertebrae and discs. The lowest dice-score was in the disc at the height of the implant where artifacts led to under-segmentation. The mean distance between the morphed meshes and the segmentations was below 1 mm. In conclusion, the presented method can be used to automatically generate accurate subject-specific spine models.

6.
Spine Deform ; 11(6): 1509-1516, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-37558820

RESUMEN

INTRODUCTION: In idiopathic scoliosis, the anterior spinal column has rotated away from the midline and has become longer through unloading and expansion of the intervertebral discs. Theoretically, extension of the spine in the sagittal plane should provide room for this longer anterior spinal column, allowing it to swing back towards the midline in the coronal and axial plane, thus reducing both the Cobb angle and the apical vertebral rotation. METHODS: In this prospective experimental study, ten patients with primary thoracic adolescent idiopathic scoliosis (AIS) underwent MRI (BoneMRI and cVISTA sequences) in supine as well as in an extended position by placing a broad bolster, supporting both hemi-thoraces, under the scoliotic apex. Differences in T4-T12 kyphosis angle, coronal Cobb angle, vertebral rotation, as well as shape of the intervertebral disc and shape and position of the nucleus pulposus, were analysed and compared between the two positions. RESULTS: Extension reduced T4-T12 thoracic kyphosis by 10° (p < 0.001), the coronal Cobb angle decreased by 9° (p < 0.001) and vertebral rotation by 4° (p = 0.036). The coronal wedge shape of the disc significantly normalized and the wedged and lateralized nucleus pulposus partially reduced to a more symmetrical position. CONCLUSION: Simple extension of the scoliotic spine leads to a reduction of the deformity in the coronal and axial plane. The shape of the disc normalizes and the eccentric nucleus pulposus partially moves back to the midline.

7.
Int J Comput Assist Radiol Surg ; 18(12): 2307-2318, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37219804

RESUMEN

INTRODUCTION: The use of MRI scans for pre-operative surgical planning of forearm osteotomies provides additional information of joint cartilage and soft tissue structures and reduces radiation exposure in comparison with the use of CT scans. In this study, we investigated whether using 3D information obtained from MRI with and without cartilage information leads to a different outcome of pre-operative planning. METHODS: Bilateral CT and MRI scans of the forearms of 10 adolescent and young adult patients with a unilateral bone deformation were acquired in a prospective study. The bones were segmented from CT and MRI, and cartilage only from MRI. The deformed bones were virtually reconstructed, by registering the joint ends to the healthy contralateral side. An optimal osteotomy plane was determined that minimized the distance between the resulting fragments. This process was performed in threefold: using the CT and MRI bone segmentations, and the MRI cartilage segmentations. RESULTS: Comparison of bone segmentation from MRI and CT scan resulted in a 0.95 ± 0.02 Dice Similarity Coefficient and 0.42 ± 0.07 mm Mean Absolute Surface Distance. All realignment parameters showed excellent reliability across the different segmentations. However, the mean differences in translational realignment between CT and MRI bone segmentations (4.5 ± 2.1 mm) and between MRI bone and MRI bone and cartilage segmentations (2.8 ± 2.1 mm) were shown to be clinically and statistically significant. A significant positive correlation was found between the translational realignment and the relative amount of cartilage. CONCLUSION: This study indicates that although bone realignment remained largely similar when using MRI with and without cartilage information compared to using CT, the small differences in segmentation could induce statistically and clinically significant differences in the osteotomy planning. We also showed that endochondral cartilage might be a non-negligible factor when planning osteotomies for young patients.


Asunto(s)
Cartílago Articular , Antebrazo , Adulto Joven , Adolescente , Humanos , Antebrazo/cirugía , Reproducibilidad de los Resultados , Estudios Prospectivos , Tomografía Computarizada por Rayos X/métodos , Imagen por Resonancia Magnética/métodos , Osteotomía/métodos
8.
J Bone Joint Surg Am ; 105(9): 700-712, 2023 05 03.
Artículo en Inglés | MEDLINE | ID: mdl-36947661

RESUMEN

BACKGROUND: Preoperative planning of lower-limb realignment surgical procedures necessitates the quantification of alignment parameters by using landmarks placed on medical scans. Conventionally, alignment measurements are performed on 2-dimensional (2D) standing radiographs. To enable fast and accurate 3-dimensional (3D) planning of orthopaedic surgery, automatic calculation of the lower-limb alignment from 3D bone models is required. The goal of this study was to develop, validate, and apply a method that automatically quantifies the parameters defining lower-limb alignment from computed tomographic (CT) scans. METHODS: CT scans of the lower extremities of 50 subjects were both manually and automatically segmented. Thirty-two manual landmarks were positioned twice on the bone segmentations to assess intraobserver reliability in a subset of 20 subjects. The landmarks were also positioned automatically using a shape-fitting algorithm. The landmarks were then used to calculate 25 angles describing the lower-limb alignment for all 50 subjects. RESULTS: The mean absolute difference (and standard deviation) between repeat measurements using the manual method was 2.01 ± 1.64 mm for the landmark positions and 1.05° ± 1.48° for the landmark angles, whereas the mean absolute difference between the manual and fully automatic methods was 2.17 ± 1.37 mm for the landmark positions and 1.10° ± 1.16° for the landmark angles. The manual method required approximately 60 minutes of manual interaction, compared with 12 minutes of computation time for the fully automatic method. The intraclass correlation coefficient showed good to excellent reliability between the manual and automatic assessments for 23 of 25 angles, and the same was true for the intraobserver reliability in the manual method. The mean for the 50 subjects was within the expected range for 18 of the 25 automatically calculated angles. CONCLUSIONS: We developed a method that automatically calculated a comprehensive range of 25 measurements that defined lower-limb alignment in considerably less time, and with differences relative to the manual method that were comparable to the differences between repeated manual assessments. This method could thus be used as an efficient alternative to manual assessment of alignment. LEVEL OF EVIDENCE: Diagnostic Level III . See Instructions for Authors for a complete description of levels of evidence.


Asunto(s)
Extremidad Inferior , Tomografía Computarizada por Rayos X , Humanos , Reproducibilidad de los Resultados , Extremidad Inferior/diagnóstico por imagen , Radiografía , Algoritmos
9.
J Orthop Res ; 41(11): 2530-2539, 2023 11.
Artículo en Inglés | MEDLINE | ID: mdl-36922347

RESUMEN

Magnetic resonance Imaging is the gold standard for assessment of soft tissues; however, X-ray-based techniques are required for evaluating bone-related pathologies. This study evaluated the performance of synthetic computed tomography (sCT), a novel MRI-based bone visualization technique, compared with CT, for the scoring of knee osteoarthritis. sCT images were generated from the 3T T1-weighted gradient-echo MR images using a trained machine learning algorithm. Two readers scored the severity of osteoarthritis in tibiofemoral and patellofemoral joints according to OACT, which enables the evaluation of osteoarthritis, from its characteristics of joint space narrowing, osteophytes, cysts and sclerosis in CT (and sCT) images. Cohen's κ was used to assess the interreader agreement for each modality, and intermodality agreement of CT- and sCT-based scores for each reader. We also compared the confidence level of readers for grading CT and sCT images using confidence scores collected during grading. Inter-reader agreement for tibiofemoral and patellofemoral joints were almost-perfect for both modalities (κ = 0.83-0.88). The intermodality agreement of osteoarthritis scores between CT and sCT was substantial to almost-perfect for tibiofemoral (κ = 0.63 and 0.84 for the two readers) and patellofemoral joints (κ = 0.78 and 0.81 for the two readers). The analysis of diagnosis confidence scores showed comparable visual quality of the two modalities, where both are showing acceptable confidence levels for scoring OA. In conclusion, in this single-center study, sCT and CT were comparable for the scoring of knee OA.


Asunto(s)
Osteoartritis de la Rodilla , Humanos , Osteoartritis de la Rodilla/diagnóstico por imagen , Osteoartritis de la Rodilla/patología , Imagen por Resonancia Magnética , Articulación de la Rodilla/patología , Radiografía , Tomografía Computarizada por Rayos X
10.
J Orthop Res ; 41(1): 183-195, 2023 01.
Artículo en Inglés | MEDLINE | ID: mdl-35289957

RESUMEN

Diagnosis of ankle impingement is performed primarily by clinical examination, whereas medical imaging is used for severity staging and treatment guidance. The association of impingement symptoms with regional three-dimensional (3D) bone shape variaties visible in medical images has not been systematically explored, nor do we know the type and magnitude of this relation. In this cross-sectional case-control study, we hypothesized that 3D talus bone shape could be used to quantitatively formulate the discriminating shape variations between ankles with impingement from ankles without impingement, and we aimed to characterize and quantify these variations. We used statistical shape modeling (SSM) methods to determine the most prevalent modes of shape variations that discriminate between the impinged and nonimpinged ankles. Results of the compactness and parallel analysis test on the statistical shape model identify 8 prominent shape modes of variations (MoVs) representing approximately 78% of the total 3D variations in the population of shapes, among which two modes captured discriminating features between impinged and nonimpinged ankles (p value of 0.023 and 0.042). Visual inspection confirms that these two shape modes, capturing abnormalities in the anterior and posterior parts of talus, represent the two main bony risk factors in anterior and posterior ankle impingement. In conclusion, in this research using SSM we have identified shape MoVs that were found to correlate significantly with bony ankle impingement. We also illustrated potential guidance from SSMs for surgical planning.


Asunto(s)
Estudios Transversales , Estudios de Casos y Controles
11.
Eur J Radiol ; 154: 110414, 2022 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-35780607

RESUMEN

PURPOSE: To investigate whether the image quality of a specific deep learning-based synthetic CT (sCT) of the cervical spine is noninferior to conventional CT. METHOD: Paired MRI and CT data were collected from 25 consecutive participants (≥ 50 years) with cervical radiculopathy. The MRI exam included a T1-weighted multiple gradient echo sequence for sCT reconstruction. For qualitative image assessment, four structures at two vertebral levels were evaluated on sCT and compared with CT by three assessors using a four-point scale (range 1-4). The noninferiority margin was set at 0.5 point on this scale. Additionally, acceptable image quality was defined as a score of 3-4 in ≥ 80% of the scans. Quantitative assessment included geometrical analysis and voxelwise comparisons. RESULTS: Qualitative image assessment showed that sCT was noninferior to CT for overall bone image quality, artifacts, imaging of intervertebral joints and neural foramina at levels C3-C4 and C6-C7, and cortical delineation at C6-C7. Noninferiority was weak to absent for cortical delineation at level C3-C4 and trabecular bone at both levels. Acceptable image quality was achieved for all structures in sCT and CT, except for trabecular bone in sCT and level C6-C7 in CT. Geometrical analysis of the sCT showed good to excellent agreement with CT. Voxelwise comparisons showed a mean absolute error of 80.05 (±6.12) HU, dice similarity coefficient (cortical bone) of 0.84 (±0.04) and structural similarity index of 0.86 (±0.02). CONCLUSIONS: This deep learning-based sCT was noninferior to conventional CT for the general visualization of bony structures of the cervical spine, artifacts, and most detailed structure assessments.


Asunto(s)
Vértebras Cervicales , Aprendizaje Profundo , Tomografía Computarizada por Rayos X , Artefactos , Inteligencia Artificial , Vértebras Cervicales/diagnóstico por imagen , Humanos , Imagen por Resonancia Magnética/métodos , Tomografía Computarizada por Rayos X/métodos
12.
J Orthop Res ; 40(12): 2894-2907, 2022 12.
Artículo en Inglés | MEDLINE | ID: mdl-35239226

RESUMEN

Semantic segmentation of bone from lower extremity computerized tomography (CT) scans can improve and accelerate the visualization, diagnosis, and surgical planning in orthopaedics. However, the large field of view of these scans makes automatic segmentation using deep learning based methods challenging, slow and graphical processing unit (GPU) memory intensive. We investigated methods to more efficiently represent anatomical context for accurate and fast segmentation and compared these with state-of-the-art methodology. Six lower extremity bones from patients of two different datasets were manually segmented from CT scans, and used to train and optimize a cascaded deep learning approach. We varied the number of resolution levels, receptive fields, patch sizes, and number of V-net blocks. The best performing network used a multi-stage, cascaded V-net approach with 1283 -643 -323 voxel patches as input. The average Dice coefficient over all bones was 0.98 ± 0.01, the mean surface distance was 0.26 ± 0.12 mm and the 95th percentile Hausdorff distance 0.65 ± 0.28 mm. This was a significant improvement over the results of the state-of-the-art nnU-net, with only approximately 1/12th of training time, 1/3th of inference time and 1/4th of GPU memory required. Comparison of the morphometric measurements performed on automatic and manual segmentations showed good correlation (Intraclass Correlation Coefficient [ICC] >0.8) for the alpha angle and excellent correlation (ICC >0.95) for the hip-knee-ankle angle, femoral inclination, femoral version, acetabular version, Lateral Centre-Edge angle, acetabular coverage. The segmentations were generally of sufficient quality for the tested clinical applications and were performed accurately and quickly compared to state-of-the-art methodology from the literature.


Asunto(s)
Huesos , Tomografía Computarizada por Rayos X , Humanos , Extremidad Inferior/diagnóstico por imagen , Procesamiento de Imagen Asistido por Computador/métodos
13.
Acta Orthop ; 93: 296-302, 2022 02 04.
Artículo en Inglés | MEDLINE | ID: mdl-35129201

RESUMEN

BACKGROUND AND PURPOSE: The Chiari osteotomy was a regular treatment for developmental hip dysplasia before it became mostly reserved as a salvage therapy. However, the long-term survival of the Chiari osteotomy has not been systematically investigated. We investigated the survival time of the Chiari osteotomy until conversion to total hip arthroplasty (THA) in patients with primary hip dysplasia, and factors which correlated with survival, complications, and the improvement measured in radiographic parameters. PATIENTS AND METHODS: Studies were included when describing patients (> 16 years) with primary hip dysplasia treated with a Chiari osteotomy procedure with 8 years' follow-up. Data on patient characteristics, indications, complications, radiographic parameters, and survival time (endpoint: conversion to THA) were extracted. RESULTS: 8 studies were included. The average postoperative center-edge angle, acetabular head index, and Sharp angle were generally restored within the target range. 3 studies reported Kaplan-Meier survival rates varying from 96% at 10 years to 72% at 20 years' follow-up. Negative survival factors were high age at intervention and pre-existing advanced preoperative osteoarthritis. Moreover, reported complications ranged between 0% and 28.3 %. INTERPRETATION: The Chiari osteotomy has high reported survival rates and is capable of restoring radiographic hip parameters to healthy values. When carefully selected by young age, and a low osteoarthritis score, patients benefit from the Chiari osteotomy with satisfactory survival rates. The position of the Chiari osteotomy in relation to the periacetabular osteotomies should be further (re-)explored.


Asunto(s)
Luxación Congénita de la Cadera , Luxación de la Cadera , Osteoartritis de la Cadera , Osteoartritis , Acetábulo/cirugía , Adolescente , Adulto , Estudios de Seguimiento , Luxación de la Cadera/cirugía , Luxación Congénita de la Cadera/complicaciones , Luxación Congénita de la Cadera/cirugía , Humanos , Osteoartritis/etiología , Osteoartritis de la Cadera/complicaciones , Osteotomía/métodos , Estudios Retrospectivos , Resultado del Tratamiento
14.
Sci Rep ; 12(1): 3032, 2022 02 22.
Artículo en Inglés | MEDLINE | ID: mdl-35194117

RESUMEN

The concept of a novel patient-specific 3D-printed shelf implant should be evaluated in a relevant large animal model with hip dysplasia. Therefore, three dogs with radiographic bilateral hip dysplasia and a positive subluxation test underwent unilateral acetabular augmentation with a 3D-printed dog-specific titanium implant. The contralateral side served as control. The implants were designed on CT-based pelvic bone segmentations and extended the dysplastic acetabular rim to increase the weight bearing surface without impairing the range of motion. Outcome was assessed by clinical observation, manual subluxation testing, radiography, CT, and gait analysis from 6 weeks preoperatively until termination at 26 weeks postoperatively. Thereafter, all hip joints underwent histopathological examination. The implantation and recovery from surgery was uneventful. Clinical subluxation tests at the intervention side became negative. Imaging showed medialization of the femoral head at the intervention side and the mean (range) CE-angle increased from 94° (84°-99°) preoperative to 119° (117°-120°) postoperative. Gait analysis parameters returned to pre-operative levels after an average follow-up of 6 weeks. Histology showed a thickened synovial capsule between the implant and the femoral head without any evidence of additional damage to the articular cartilage compared to the control side. The surgical implantation of the 3D shelf was safe and feasible. The patient-specific 3D-printed shelf implants restored the femoral head coverage and stability of dysplastic hips without complications. The presented approach holds promise to treat residual hip dysplasia justifying future veterinary clinical trials to establish clinical effectiveness in a larger cohort to prepare for translation to human clinic.


Asunto(s)
Luxación de la Cadera/diagnóstico por imagen , Luxación de la Cadera/terapia , Impresión Tridimensional , Prótesis e Implantes , Diseño de Prótesis/métodos , Acetábulo , Animales , Modelos Animales de Enfermedad , Perros , Estudios de Factibilidad , Marcha , Luxación de la Cadera/fisiopatología , Humanos , Huesos Pélvicos , Seguridad , Titanio , Tomografía Computarizada por Rayos X/métodos
15.
Eur Radiol ; 32(7): 4537-4546, 2022 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-35190891

RESUMEN

OBJECTIVES: Visualization of the bone distribution is an important prerequisite for MRI-guided high-intensity focused ultrasound (MRI-HIFU) treatment planning of bone metastases. In this context, we evaluated MRI-based synthetic CT (sCT) imaging for the visualization of cortical bone. METHODS: MR and CT images of nine patients with pelvic and femoral metastases were retrospectively analyzed in this study. The metastatic lesions were osteolytic, osteoblastic or mixed. sCT were generated from pre-treatment or treatment MR images using a UNet-like neural network. sCT was qualitatively and quantitatively compared to CT in the bone (pelvis or femur) containing the metastasis and in a region of interest placed on the metastasis itself, through mean absolute difference (MAD), mean difference (MD), Dice similarity coefficient (DSC), and root mean square surface distance (RMSD). RESULTS: The dataset consisted of 3 osteolytic, 4 osteoblastic and 2 mixed metastases. For most patients, the general morphology of the bone was well represented in the sCT images and osteolytic, osteoblastic and mixed lesions could be discriminated. Despite an average timespan between MR and CT acquisitions of 61 days, in bone, the average (± standard deviation) MAD was 116 ± 26 HU, MD - 14 ± 66 HU, DSC 0.85 ± 0.05, and RMSD 2.05 ± 0.48 mm and, in the lesion, MAD was 132 ± 62 HU, MD - 31 ± 106 HU, DSC 0.75 ± 0.2, and RMSD 2.73 ± 2.28 mm. CONCLUSIONS: Synthetic CT images adequately depicted the cancellous and cortical bone distribution in the different lesion types, which shows its potential for MRI-HIFU treatment planning. KEY POINTS: • Synthetic computed tomography was able to depict bone distribution in metastatic lesions. • Synthetic computed tomography images intrinsically aligned with treatment MR images may have the potential to facilitate MR-HIFU treatment planning of bone metastases, by combining visualization of soft tissues and cancellous and cortical bone.


Asunto(s)
Neoplasias Óseas , Imagen por Resonancia Magnética , Neoplasias Óseas/diagnóstico por imagen , Neoplasias Óseas/terapia , Estudios de Factibilidad , Fémur/diagnóstico por imagen , Humanos , Imagen por Resonancia Magnética/métodos , Pelvis , Planificación de la Radioterapia Asistida por Computador/métodos , Estudios Retrospectivos , Tomografía Computarizada por Rayos X/métodos
16.
J Magn Reson Imaging ; 56(1): 11-34, 2022 07.
Artículo en Inglés | MEDLINE | ID: mdl-35044717

RESUMEN

Magnetic resonance imaging (MRI) is increasingly utilized as a radiation-free alternative to computed tomography (CT) for the diagnosis and treatment planning of musculoskeletal pathologies. MR imaging of hard tissues such as cortical bone remains challenging due to their low proton density and short transverse relaxation times, rendering bone tissues as nonspecific low signal structures on MR images obtained from most sequences. Developments in MR image acquisition and post-processing have opened the path for enhanced MR-based bone visualization aiming to provide a CT-like contrast and, as such, ease clinical interpretation. The purpose of this review is to provide an overview of studies comparing MR and CT imaging for diagnostic and treatment planning purposes in orthopedic care, with a special focus on selective bone visualization, bone segmentation, and three-dimensional (3D) modeling. This review discusses conventional gradient-echo derived techniques as well as dedicated short echo time acquisition techniques and post-processing techniques, including the generation of synthetic CT, in the context of 3D and specific bone visualization. Based on the reviewed literature, it may be concluded that the recent developments in MRI-based bone visualization are promising. MRI alone provides valuable information on both bone and soft tissues for a broad range of applications including diagnostics, 3D modeling, and treatment planning in multiple anatomical regions, including the skull, spine, shoulder, pelvis, and long bones. LEVEL OF EVIDENCE: 3 TECHNICAL EFFICACY: Stage 3.


Asunto(s)
Imagen por Resonancia Magnética , Tomografía Computarizada por Rayos X , Humanos , Imagenología Tridimensional , Imagen por Resonancia Magnética/métodos , Pelvis , Cráneo , Tomografía Computarizada por Rayos X/métodos
17.
J Orthop Res ; 40(5): 1154-1162, 2022 05.
Artículo en Inglés | MEDLINE | ID: mdl-34191341

RESUMEN

A solution for challenging hip dysplasia surgery could be a patient-specific 3D-printed shelf implant that is positioned extra-articular and restores the dysplastic acetabular rim to normal anatomical dimensions. The anatomical correction and biomechanical stability of this concept were tested in a canine model that, like humans, also suffers from hip dysplasia. Using 3D reconstructed computed tomography images the 3D shelf implant was designed to restore the radiological dysplastic hip parameters to healthy parameters. It was tested ex vivo on three dog cadavers (six hips) with hip dysplasia. Each hip was subjected to a biomechanical subluxation test, first without and then with the 3D shelf implant in place. Subsequently, an implant failure test was performed to test the primary implant fixation. At baseline, the dysplastic hips had an average Norberg angle of 88 ± 3° and acetabular coverage of 47 ± 2% and subluxated at an average of 83 ± 2° of femoral adduction. After adding the patient-specific shelf implants the dysplastic hips had an average Norberg angle of 122 ± 2° and acetabular coverage of 67 ± 3% and subluxated at an average of 117 ± 2° of femoral adduction. Implant failure after primary implant fixation occurred at an average of 1330 ± 320 Newton. This showed that the patient-specific shelf implants significantly improved the coverage and stability of dysplastic hips in a canine model with naturally occurring hip dysplasia. The 3D shelf is a promising concept for treating residual hip dysplasia with a straightforward technology-driven approach; however, the clinical safety needs to be further investigated in an experimental proof-of-concept animal study.


Asunto(s)
Luxación Congénita de la Cadera , Luxación de la Cadera , Acetábulo/cirugía , Animales , Perros , Luxación Congénita de la Cadera/cirugía , Articulación de la Cadera/cirugía , Humanos , Impresión Tridimensional , Estudios Retrospectivos
18.
J Orthop Res ; 40(4): 954-964, 2022 04.
Artículo en Inglés | MEDLINE | ID: mdl-34191351

RESUMEN

This study evaluated the accuracy of synthetic computed tomography (sCT), as compared to CT, for the 3D assessment of the hip morphology. Thirty male patients with asymptomatic hips, referred for magnetic resonance (MR) imaging and CT, were included in this retrospective study. sCT images were generated from three-dimensional radiofrequency-spoiled T1-weighted multi-echo gradient-echo MR images using a commercially available deep learning-enabled software and were compared with CT images through mean error and surface distance computation and by means of eight clinical morphometric parameters relevant for hip care. Parameters included center-edge angle (CEA), sharp angle, acetabular index, extrusion index, femoral head center-to-midline distance, acetabular version (AV), and anterior and posterior acetabular sector angles. They were measured by two senior orthopedic surgeons and a radiologist in-training on CT and sCT images. The reliability and agreement of CT- and sCT-based measurements were assessed using intraclass correlation coefficients (ICCs) for absolute agreement, Bland-Altman plots, and two one-sided tests for equivalence. The surface distance between CT- and sCT-based bone models were on average submillimeter. CT- and sCT-based measurements showed moderate to excellent interobserver and intraobserver correlation (0.56 < ICC < 0.99). In particular, the inter/intraobserver agreements were good for AV (ICC > 0.75). For CEA, the intraobserver agreement was good (ICC > 0.75) and the interobserver agreement was moderate (ICC > 0.69). Limits of agreements were similar between intraobserver CT and intermodal measurements. All measurements were found statistically equivalent, with average intermodal differences within the intraobserver limits of agreement. In conclusion, sCT and CT were equivalent for the assessment of the hip joint bone morphology.


Asunto(s)
Articulación de la Cadera , Imagen por Resonancia Magnética , Articulación de la Cadera/diagnóstico por imagen , Articulación de la Cadera/cirugía , Humanos , Masculino , Reproducibilidad de los Resultados , Estudios Retrospectivos , Tomografía Computarizada por Rayos X
19.
J Clin Med ; 10(15)2021 Jul 21.
Artículo en Inglés | MEDLINE | ID: mdl-34362001

RESUMEN

In scoliosis, most of the deformity is in the disc and occurs during the period of rapid growth. The ring apophyses form the insertion of the disc into the vertebral body, they then ossify and fuse to the vertebrae during that same crucial period. Although this must have important implications for the mechanical properties of the spine, relatively little is known of how this process takes place. This study describes the maturation pattern of the ring apophyses in the thoracic and lumbar spine during normal growth. High-resolution CT scans of the spine for indications not related to this study were included. Ossification and fusion of each ring apophysis from T1 to the sacrum was classified on midsagittal and midcoronal images (4 points per ring) by two observers. The ring apophysis maturation (RAM) was compared between different ages, sexes, and spinal levels. The RAM strongly correlated with age (R = 0.892, p < 0.001). Maturation differed in different regions of the spine and between sexes. High thoracic and low lumbar levels fused earlier in both groups, but, around the peak of the growth spurt, in girls the mid-thoracic levels were less mature than in boys, which may have implications for the development of scoliosis.

20.
Magn Reson Med ; 86(6): 3156-3165, 2021 12.
Artículo en Inglés | MEDLINE | ID: mdl-34270127

RESUMEN

PURPOSE: To extend the double echo steady-state (DESS) sequence to enable chemical-shift corrected water-fat separation. METHODS: This study proposes multiple-echo steady-state (MESS), a sequence that modifies the readouts of the DESS sequence to acquire two echoes each with bipolar readout gradients with higher readout bandwidth. This enables water-fat separation and eliminates the need for water-selective excitation that is often used in combination with DESS, without increasing scan time. An iterative fitting approach was used to perform joint chemical-shift corrected water-fat separation and T2 estimation on all four MESS echoes simultaneously. MESS and water-selective DESS images were acquired for five volunteers, and were compared qualitatively as well as quantitatively on cartilage T2 and thickness measurements. Signal-to-noise ratio (SNR) and T2 quantification were evaluated numerically using pseudo-replications of the acquisition. RESULTS: The water-fat separation provided by MESS was robust and with quality comparable to water-selective DESS. MESS T2 estimation was similar to DESS, albeit with slightly higher variability. Noise analysis showed that SNR in MESS was comparable to DESS on average, but did exhibit local variations caused by uncertainty in the water-fat separation. CONCLUSION: In the same acquisition time as DESS, MESS provides water-fat separation with comparable SNR in the reconstructed water and fat images. By providing additional image contrasts in addition to the water-selective DESS images, MESS provides a promising alternative to DESS.


Asunto(s)
Interpretación de Imagen Asistida por Computador , Agua , Humanos , Procesamiento de Imagen Asistido por Computador , Imagen por Resonancia Magnética , Reproducibilidad de los Resultados , Relación Señal-Ruido
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...