Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros










Intervalo de año de publicación
1.
Acta Otorhinolaryngol Ital ; 34(4): 264-71, 2014 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-25210221

RESUMEN

In auditory research, hearing function of mouse mutants is assessed in vivo by evoked potential recording. Evaluation of the response parameters should be performed with reference to the evoked responses recorded from wild-type mice. This study reports normative data calculated on auditory brainstem responses (ABRs) obtained from 20 wild-type C57 BL/6J mice at a postnatal age between 21 and 45 days. Acoustic stimuli consisted tone bursts at 8, 14, 20, 26, 32 kHz, and clicks. Each stimulus was delivered in free field at stimulation intensity starting from a maximum of 100 dB peak equivalent SPL (dB peSPL) at decreasing steps of 10 dB with a repetition rate of 13/sec. Evoked responses were recorded by needle electrodes inserted subcutaneously. At high intensity stimulation, five response waveforms, each consisting of a positive peak and a subsequent negative valley, were identified within 7 msec, and were labelled with sequential capital Roman numerals from I to V. Peak IV was the most robust and stable at low intensities for both tone burst and click stimuli, and was therefore utilized to estimate hearing thresholds. Both latencies and amplitudes of ABR peaks showed good reproducibility with acceptable standard deviations. Mean wave IV thresholds measured across all animals ranged from a maximum of 23 dB peSPL for clicks to a minimum of 7 dB peSPL for 20 kHz-tone burst stimuli. Statistical analysis of the distribution of latencies and amplitudes of peaks from I to V performed for each stimulus type yielded a normative data set which was utilised to obtain the most consistent fitting-curve model. This could serve as a reference for further studies on murine models of hearing loss.


Asunto(s)
Potenciales Evocados Auditivos del Tronco Encefálico , Ratones Endogámicos C57BL/fisiología , Animales , Femenino , Masculino , Ratones
2.
Rev Sci Instrum ; 84(3): 033505, 2013 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-23556819

RESUMEN

The non-intrusive density measurement of the thin plasma produced by a mini-helicon space thruster (HPH.com project) is a challenge, due to the broad density range (between 10(16) m(-3) and 10(19) m(-3)) and the small size of the plasma source (2 cm of diameter). A microwave interferometer has been developed for this purpose. Due to the small size of plasma, the probing beam wavelength must be small (λ = 4 mm), thus a very high sensitivity interferometer is required in order to observe the lower density values. A low noise digital phase detector with a phase noise of 0.02° has been used, corresponding to a density of 0.5 × 10(16) m(-3).

3.
Rev. saúde pública ; 31(6): 618-23, 1997. ilus, tab
Artículo en Portugués | LILACS | ID: lil-206952

RESUMEN

Os valores de referência de indicadores biológicos säo utilizados como parâmetros para interpretaçäo de resultados de valores obtidos em indivíduos expostos ocupacionalmente aos agentes químicos. O Grupo Brasileiro para Estabelecimento dos Valores de Referência em se dedicado a estas determinaçöes objetivando estabelecer valores de referência para os diferentes bioindicadores em diversas regiöes do País. Determinaram-se os valores de referência para a carboxiemoglobina (COHb) no sul de Minas Gerais. A COHb foi analisada pelo método espectrofométrico, otimizado no laboratório de análises toxicológicasl. Em todas as amostras também foram realizadas análises toxicológicas. Em todas as amostras também foram realizadas análises de alguns parâmetros bioquímicos e hematológicos para atestar o estado de saúde da populaçäo, constituída de 200 voluntários näo-fumantes e näo-expostos, por motivo profissional, ao monóxido de carbono. Cada indivíduo respondeu um questionário para levantamento de dados relevantes à interpretaçäo dos resultados. Os valores de referência foram expressos em termos da média + ou - desvio-padräo, intervalo de confiança 95 por cento e valor de referência superior. A distribuiçäo estatística dos resultados obtidos foi realizada para possibilitar sua comparaçäo com grupos de trabalhadores, preferentemente à avaliaçäo individual. O valor + ou - desvio-padräo para a carboxiemoglobina foi de 1,0 por cento + ou - 0,75; o intervalo de confiança 95 por cento, entre 0,9 e 1,1 por cento e o valor de referência superior, de 2,5 por cento. Através do teste t de Student (p<0,05) näo foi detectada diferença nos valores de acordo com o sexo, idade ou uso de bebidas alcoólicas. Os valores de referência encontrados foram similares aos reportados em outros países


Asunto(s)
Adulto , Humanos , Valores de Referencia , Carboxihemoglobina , Factores de Riesgo , Monóxido de Carbono , Encuestas y Cuestionarios , Salud Laboral
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...