Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 51
Filtrar
1.
Int J Mol Sci ; 25(10)2024 May 10.
Artículo en Inglés | MEDLINE | ID: mdl-38791256

RESUMEN

Interrupted blood flow in the brain due to ischemic injuries such as ischemic stroke or traumatic brain injury results in irreversible brain damage, leading to cognitive impairment associated with inflammation, disruption of the blood-brain barrier (BBB), and cell death. Since the BBB only allows entry to a small class of drugs, many drugs used to treat ischemia in other tissues have failed in brain-related disorders. The administration of mesenchymal stem cell (MSC)-derived extracellular vesicles (EVs) has shown promise in improving the functional recovery of the brain following cerebral ischemia by inducing blood vessel formation. To facilitate such a treatment approach, it is necessary to develop bioprocesses that can produce therapeutically relevant MSC-EVs in a reproducible and scalable manner. This study evaluated the feasibility of using stirred suspension bioreactors (SSBs) to scale-up the serum-free production of pro-angiogenic MSC-EVs under clinically relevant physioxic conditions. It was found that MSCs grown in SSBs generated EVs that stimulated angiogenesis in cerebral microvascular endothelial cells, supporting the use of SSBs to produce MSC-EVs for application in cerebral ischemia. These properties were impaired at higher cell confluency, outlining the importance of considering the time of harvest when developing bioprocesses to manufacture EV populations.


Asunto(s)
Reactores Biológicos , Células Endoteliales , Vesículas Extracelulares , Células Madre Mesenquimatosas , Neovascularización Fisiológica , Vesículas Extracelulares/metabolismo , Células Madre Mesenquimatosas/metabolismo , Células Madre Mesenquimatosas/citología , Humanos , Células Endoteliales/metabolismo , Células Endoteliales/citología , Encéfalo/metabolismo , Encéfalo/irrigación sanguínea , Células Cultivadas , Barrera Hematoencefálica/metabolismo , Angiogénesis
2.
Stem Cell Res Ther ; 14(1): 218, 2023 08 23.
Artículo en Inglés | MEDLINE | ID: mdl-37612731

RESUMEN

BACKGROUND: Following an ischemic injury to the brain, the induction of angiogenesis is critical to neurological recovery. The angiogenic benefits of mesenchymal stem cells (MSCs) have been attributed at least in part to the actions of extracellular vesicles (EVs) that they secrete. EVs are membrane-bound vesicles that contain various angiogenic biomolecules capable of eliciting therapeutic responses and are of relevance in cerebral applications due to their ability to cross the blood-brain barrier (BBB). Though MSCs are commonly cultured under oxygen levels present in injected air, when MSCs are cultured under physiologically relevant oxygen conditions (2-9% O2), they have been found to secrete higher amounts of survival and angiogenic factors. There is a need to determine the effects of MSC-EVs in models of cerebral angiogenesis and whether those from MSCs cultured under physiological oxygen provide greater functional effects. METHODS: Human adipose-derived MSCs were grown in clinically relevant serum-free medium and exposed to either headspace oxygen concentrations of 18.4% O2 (normoxic) or 3% O2 (physioxic). EVs were isolated from MSC cultures by differential ultracentrifugation and characterized by their size, concentration of EV specific markers, and their angiogenic protein content. Their functional angiogenic effects were evaluated in vitro by their induction of cerebral microvascular endothelial cell (CMEC) proliferation, tube formation, and angiogenic and tight junction gene expressions. RESULTS: Compared to normoxic conditions, culturing MSCs under physioxic conditions increased their expression of angiogenic genes SDF1 and VEGF, and subsequently elevated VEGF-A content in the EV fraction. MSC-EVs demonstrated an ability to induce CMEC angiogenesis by promoting tube formation, with the EV fraction from physioxic cultures having the greatest effect. The physioxic EV fraction further upregulated the expression of CMEC angiogenic genes FGF2, HIF1, VEGF and TGFB1, as well as genes (OCLN and TJP1) involved in BBB maintenance. CONCLUSIONS: EVs from physioxic MSC cultures hold promise in the generation of a cell-free therapy to induce angiogenesis. Their positive angiogenic effect on cerebral microvascular endothelial cells demonstrates that they may have utility in treating ischemic cerebral conditions, where the induction of angiogenesis is critical to improving recovery and neurological function.


Asunto(s)
Vesículas Extracelulares , Células Madre Mesenquimatosas , Humanos , Células Endoteliales , Factor A de Crecimiento Endotelial Vascular/genética , Encéfalo , Factores Inmunológicos
3.
J Extracell Vesicles ; 12(9): e12353, 2023 09.
Artículo en Inglés | MEDLINE | ID: mdl-37632212

RESUMEN

Small extracellular vesicles (EVs) have emerged as a focal point of EV research due to their significant role in a wide range of physiological and pathological processes within living systems. However, uncertainties about the nature of these vesicles have added considerable complexity to the already difficult task of developing EV-based diagnostics and therapeutics. Whereas small EVs have been shown to be negatively charged, their surface charge has not yet been properly quantified. This gap in knowledge has made it challenging to fully understand the nature of these particles and the way they interact with one another, and with other biological structures like cells. Most published studies have evaluated EV charge by focusing on zeta potential calculated using classical theoretical approaches. However, these approaches tend to underestimate zeta potential at the nanoscale. Moreover, zeta potential alone cannot provide a complete picture of the electrical properties of small EVs since it ignores the effect of ions that bind tightly to the surface of these particles. The absence of validated methods to accurately estimate the actual surface charge (electrical valence) and determine the zeta potential of EVs is a significant knowledge gap, as it limits the development of effective label-free methods for EV isolation and detection. In this study, for the first time, we show how the electrical charge of small EVs can be more accurately determined by accounting for the impact of tightly bound ions. This was accomplished by measuring the electrophoretic mobility of EVs, and then analytically correlating the measured values to their charge in the form of zeta potential and electrical valence. In contrast to the currently used theoretical expressions, the employed analytical method in this study enabled a more accurate estimation of EV surface charge, which will facilitate the development of EV-based diagnostic and therapeutic applications.


Asunto(s)
Vesículas Extracelulares , Propiedades de Superficie
4.
ACS Biomater Sci Eng ; 9(6): 3556-3569, 2023 06 12.
Artículo en Inglés | MEDLINE | ID: mdl-37067234

RESUMEN

Elevated glial fibrillary acidic protein (GFAP) in the blood serum is one of the promising bodily fluid markers for the diagnosis of central nervous system (CNS) injuries, including traumatic brain injury (TBI), stroke, and spinal cord injury (SCI). However, accurate and point-of-care (POC) quantification of GFAP in clinical blood samples has been challenging and yet to be clinically validated against gold-standard assays and outcome practices. This work engineered and characterized a novel nanoporous carbon screen-printed electrode with significantly increased surface area and conductivity, as well as preserved stability and anti-fouling properties. This nano-decorated electrode was immobilized with the target GFAP antibody to create an ultrasensitive GFAP immunosensor and quantify GFAP levels in spiked samples and the serum of CNS injury patients. The immunosensor presented a dynamic detection range of 100 fg/mL to 10 ng/mL, a limit of detection of 86.6 fg/mL, and a sensitivity of 20.3 Ω mL/pg mm2 for detecting GFAP in the serum. Its clinical utility was demonstrated by the consistent and selective quantification of GFAP comparable to the ultrasensitive single-molecule array technology in 107 serum samples collected from TBI, stroke, and SCI patients. Comparing the diagnostic and prognostic performance of the immunosensor with the existing clinical paradigms confirms the immunosensor's accuracy as a potential complement to the existing imaging diagnostic modalities and presents a potential for rapid, accurate, cost-effective, and near real-time POC diagnosis and prognosis of CNS injuries.


Asunto(s)
Técnicas Biosensibles , Lesiones Traumáticas del Encéfalo , Nanoporos , Traumatismos de la Médula Espinal , Accidente Cerebrovascular , Humanos , Carbono , Proteína Ácida Fibrilar de la Glía , Biomarcadores , Inmunoensayo , Lesiones Traumáticas del Encéfalo/diagnóstico , Traumatismos de la Médula Espinal/diagnóstico , Accidente Cerebrovascular/diagnóstico
5.
Polymers (Basel) ; 14(9)2022 May 03.
Artículo en Inglés | MEDLINE | ID: mdl-35567040

RESUMEN

Linear and crosslinked polymers are commonly used in the oil and gas industry. Guar-derived polymers have been extensively utilized in hydraulic fracturing processes, and recently polyacrylamide and cellulose-based polymers have also found utility. As these polymers are used during various phases of the hydraulic fracturing process, they can accumulate at formation fracture faces, resulting in undesired filter cakes that impede oil and gas recovery. Although acids and chemical oxidizers are often added in the fracturing fluids to degrade or 'break' polymer filter cakes, the constant use of these chemicals can be hazardous and can result in formation damage and corrosion of infrastructure. Alternately, the use of enzymes is an attractive and environmentally friendly technology that can be used to treat polymer accumulations. While guar-linkage-specific enzyme breakers isolated from bacteria have been shown to successfully cleave guar-based polymers and decrease their molecular weight and viscosity at reservoir conditions, new enzymes that target a broader range of polymers currently used in hydraulic fracturing operations still require research and development for effective application. This review article describes the current state-of-knowledge on the mechanisms and enzymes involved in biodegradation of guar gum, polyacrylamide (and hydrolyzed polyacrylamide), and carboxymethyl cellulose polymers. In addition, advantages and challenges in the development and application of enzyme breaker technologies are discussed.

6.
Stem Cells Transl Med ; 11(1): 73-87, 2022 03 03.
Artículo en Inglés | MEDLINE | ID: mdl-35641171

RESUMEN

Mesenchymal progenitor cells (MPCs) have shown promise initiating articular cartilage repair, with benefits largely attributed to the trophic factors they secrete. These factors can be found in the conditioned medium (CM) collected from cell cultures, and it is believed that extracellular vesicles (EVs) within this CM are at least partially responsible for MPC therapeutic efficacy. This study aimed to examine the functionality of the EV fraction of CM compared to whole CM obtained from human adipose-derived MPCs in an in vivo murine cartilage defect model. Mice treated with whole CM or the EV fraction demonstrated an enhanced cartilage repair score and type II collagen deposition at the injury site compared to saline controls. We then developed a scalable bioprocess using stirred suspension bioreactors (SSBs) to generate clinically relevant quantities of MPC-EVs. Whereas static monolayer culture systems are simple to use and readily accessible, SSBs offer increased scalability and a more homogenous environment due to constant mixing. This study evaluated the biochemical and functional properties of MPCs and their EV fractions generated in static culture versus SSBs. Functionality was assessed using in vitro MPC chondrogenesis as an outcome measure. SSBs supported increased MPC expression of cartilage-specific genes, and EV fractions derived from both static and SSB culture systems upregulated type II collagen production by MPCs. These results suggest that SSBs are an effective platform for the generation of MPC-derived EVs with the potential to induce cartilage repair.


Asunto(s)
Cartílago Articular , Vesículas Extracelulares , Células Madre Mesenquimatosas , Regeneración , Animales , Reactores Biológicos , Tratamiento Basado en Trasplante de Células y Tejidos , Condrocitos/metabolismo , Colágeno Tipo II/metabolismo , Medios de Cultivo Condicionados/farmacología , Humanos , Ratones
7.
J Biotechnol ; 347: 18-25, 2022 Mar 10.
Artículo en Inglés | MEDLINE | ID: mdl-35131365

RESUMEN

Carboxymethyl cellulose (CMC) is often used during hydraulic fracturing (fracking) operations as a fluid viscosifier to facilitate proppant delivery. However, the accumulation of residual CMC at fracture faces can result in formation damage, thereby impeding oil and gas recovery. Whereas harsh chemical oxidizers are typically added to disrupt these polymer accumulations, there is now industrial interest in developing clean, biological approaches for the degradation of CMC under fracking conditions. Using a methanogenic culture known to utilize CMC under conditions typically found in oil fields, we developed an efficient method to isolate and purify CMC-degrading enzymes. Initial purification and concentration of cellular components produced an increase in exo-ß-(1,4)-exoglucanase and ß-(1,4)-glucosidase activities by 9-fold and 26-fold, respectively. Partially purified extracts provided substantial degradation of CMC as monitored by viscosity reduction within three hours at 50 °C, an improvement over the untreated cell-free extract which required 48 h to achieve similar viscosity values, outperforming a commercially-available cellulase preparation. Putative cellulases were identified within the isolated enzyme population, with endo-ß-(1,4)-xylanase from Caldicoprobacter faecalis hypothesized to be an important contributor to CMC degradation. This study demonstrates that enzyme technology holds great promise as a viable approach to degrade CMC accumulations under field conditions.


Asunto(s)
Celulasa , Celulasas , Carboximetilcelulosa de Sodio/metabolismo , Celulasa/metabolismo , Celulasas/metabolismo , Yacimiento de Petróleo y Gas , Polímeros
8.
J Neurosurg ; : 1-8, 2022 Jan 28.
Artículo en Inglés | MEDLINE | ID: mdl-35090127

RESUMEN

OBJECTIVE: Delayed neointima formation over a neurovascular stent is associated with thrombotic complications that can lead to stroke. The purpose of this study was to evaluate whether an intra-arterial injection of mesenchymal stem cells (MSCs) after stent placement leads to improved neointima and reduced thrombus formation over the device. METHODS: Solitaire stents were placed into the aortas of rabbits that were divided into MSC and control groups. The MSC group received an intra-arterial injection of MSCs through the same microcatheter used for stent deployment. Optical coherence tomography (OCT) was used to evaluate and compare neointima and thrombus formation in a blinded fashion. Explanted specimens were also imaged with scanning electron microscopy (SEM) and evaluated by observers blinded to group allocation using an endothelialization scoring system. RESULTS: The 3-day MSC group was similar to the 7-day controls in terms of stent strut coverage ratio and maximum neointimal thickness, but these values were significantly higher than the 3-day control group based on a hierarchical mixed-effects linear regression analysis. SEM revealed a significantly higher endothelialization score for the MSC group compared with controls at the same time point. There was no difference in thrombus formation between any of the groups. CONCLUSIONS: The intra-arterial injection of MSCs after endovascular stenting accelerated early neointima formation but had no effect on thrombus formation in this study. Larger studies are required to verify these findings and determine the durability and mechanism of this effect.

9.
ACS Nano ; 15(11): 17047-17079, 2021 11 23.
Artículo en Inglés | MEDLINE | ID: mdl-34723478

RESUMEN

Exosomes are cell-derived structures packaged with lipids, proteins, and nucleic acids. They exist in diverse bodily fluids and are involved in physiological and pathological processes. Although their potential for clinical application as diagnostic and therapeutic tools has been revealed, a huge bottleneck impeding the development of applications in the rapidly burgeoning field of exosome research is an inability to efficiently isolate pure exosomes from other unwanted components present in bodily fluids. To date, several approaches have been proposed and investigated for exosome separation, with the leading candidate being microfluidic technology due to its relative simplicity, cost-effectiveness, precise and fast processing at the microscale, and amenability to automation. Notably, avoiding the need for exosome labeling represents a significant advance in terms of process simplicity, time, and cost as well as protecting the biological activities of exosomes. Despite the exciting progress in microfluidic strategies for exosome isolation and the countless benefits of label-free approaches for clinical applications, current microfluidic platforms for isolation of exosomes are still facing a series of problems and challenges that prevent their use for clinical sample processing. This review focuses on the recent microfluidic platforms developed for label-free isolation of exosomes including those based on sieving, deterministic lateral displacement, field flow, and pinched flow fractionation as well as viscoelastic, acoustic, inertial, electrical, and centrifugal forces. Further, we discuss advantages and disadvantages of these strategies with highlights of current challenges and outlook of label-free microfluidics toward the clinical utility of exosomes.


Asunto(s)
Exosomas , Exosomas/química , Microfluídica , Proteínas/análisis , Acústica
10.
Acta Biomater ; 136: 266-278, 2021 12.
Artículo en Inglés | MEDLINE | ID: mdl-34547516

RESUMEN

Physiologically relevant intracranial aneurysm (IA) models are crucially required to facilitate testing treatment options for IA. Herein, we report the development of a new in vitro tissue-engineered platform, which recapitulates the microenvironment, structure, and cellular complexity of native human IA. A new modified liquid-assisted injection molding technique was developed to fabricate a three-dimensional hollow IA model with clinically relevant IA dimensions within a mechanically tuned Gelatin Methacryloyl (GelMA) hydrogel. An endothelium lining was created inside the IA model by culturing human umbilical vein endothelial cells over pre-cultured human brain vascular smooth muscle cells. These cellularized IA models were subjected to medium perfusion at flow rates between 6.3 and 15.75 mL/min for inducing biomimetic vessel wall shear stress (10-25 dyn/cm2) to the cells for ten days. Both cell types maintained their secretome profiles and showed more than 96% viability, demonstrating the biocompatibility of the hydrogel during perfusion cell culture at such flow rates. Based on the characterized viscoelastic properties of the GelMA hydrogel and with the aid of a fluid-structure interaction model, the capability of the IA model in predicting the response of the IA to different fluid flow profiles was mathematically shown. With physiologically relevant behavior, our developed in vitro human IA model could allow researchers to better understand the pathophysiology and treatment of IA. STATEMENT OF SIGNIFICANCE: A three-dimensional intracranial aneurysm (IA) tissue model recapitulating the microenvironment, structure, and cellular complexity of native human IA was developed. • An endothelium lining was created inside the IA model over pre-cultured human brain vascular smooth muscle cells over at least 10-day successful culture. • The cells maintained their secretome profiles, demonstrating the biocompatibility of hydrogel during a long-term perfusion cell culture. • The IA model showed its capability in predicting the response of IA to different fluid flow profiles. • The cells in the vessel region behaved differently from cells in the aneurysm region due to alteration in hemodynamic shear stress. • The IA model could allow researchers to better understand the pathophysiology and treatment options of IA.


Asunto(s)
Hidrogeles , Aneurisma Intracraneal , Gelatina , Células Endoteliales de la Vena Umbilical Humana , Humanos , Aneurisma Intracraneal/terapia , Metacrilatos , Secretoma , Ingeniería de Tejidos
11.
World Neurosurg ; 152: e173-e179, 2021 08.
Artículo en Inglés | MEDLINE | ID: mdl-34116263

RESUMEN

BACKGROUND: Creating aneurysm sizes in animal models that resemble human aneurysms is essential to study and test neuroendovascular devices. The commonly used rabbit surgical elastase model, however, produces saccular aneurysms that are smaller than those typically treated in humans. The goal of this study was to determine whether an increased vessel stump length and the addition of calcium chloride to the incubation solution has an effect on the resulting aneurysm size. METHODS: Using a modified aneurysm creation method, 32 female New Zealand White rabbits underwent aneurysm creation procedures. Subjects were equally allocated into 4 different groups based on vessel stump length (2 cm controls vs. 3 cm) and incubation solution (elastase alone controls vs. a 1:1 mixture of elastase and calcium chloride). At 4 weeks, all animals underwent angiography to determine the resulting aneurysm size by a neurointerventionalist who was blinded to treatment group. RESULTS: An increase in stump length from 2 cm to 3 cm resulted in a significant increase in the height of aneurysm (P < 0.05). Compared with control animals, the combination of a 3-cm stump length and the addition of calcium chloride to the incubation solution resulted in a significant increase in aneurysm height, width, and volume (P < 0.05). CONCLUSIONS: Creating larger aneurysms is necessary for the rabbit model to be more clinically relevant. Our study demonstrated that the utilization of a 3-cm vessel stump as well as both calcium chloride and elastase in the incubation solution results in aneurysm sizes that more closely resemble the population of aneurysms treated in humans.


Asunto(s)
Aneurisma Intracraneal/inducido químicamente , Aneurisma Intracraneal/diagnóstico por imagen , Modelos Anatómicos , Elastasa Pancreática , Algoritmos , Angiografía de Substracción Digital , Animales , Cloruro de Calcio/farmacología , Arteria Carótida Común , Angiografía Cerebral , Femenino , Humanos , Aneurisma Intracraneal/cirugía , Conejos
12.
Sci Rep ; 11(1): 4821, 2021 03 01.
Artículo en Inglés | MEDLINE | ID: mdl-33649369

RESUMEN

Microfluidic devices have been used progressively in biomedical research due to the advantages they offer, such as relatively low-cost, rapid and precise processing, and an ability to support highly automated analyses. Polydimethylsiloxane (PDMS) and polymethylmethacrylate (PMMA) are both biocompatible materials widely used in microfluidics due to their desirable characteristics. It is recognized that combining these two particular materials in a single microfluidic device would enable the development of an increasingly in-demand array of new applications, including those requiring high flow rates and elevated pressures. Whereas complicated and time-consuming efforts have been reported for bonding these two materials, the robust adhesion of PDMS and PMMA has not yet been accomplished, and remains a challenge. In this study, a new, simple, efficient, and low-cost method has been developed to mediate a strong bond between PMMA and PDMS layers at room temperature in less than 5 min using biocompatible adhesive tape and oxygen plasma treatment. The PDMS-PMMA bond was hydrolytically stable, and could tolerate a high influx of fluid without any leakage. This study addresses the limitations of existing approaches to bond these materials, and will enable the development of highly sought high-pressure and high-throughput biomedical applications.

13.
Microb Biotechnol ; 14(3): 953-966, 2021 05.
Artículo en Inglés | MEDLINE | ID: mdl-33428324

RESUMEN

Carboxymethyl cellulose (CMC) is a polymer used in many different industrial sectors. In the oil and gas industry, CMC is often used during hydraulic fracturing (fracking) operations as a thickening agent for effective proppant delivery. Accumulations of CMC at fracture faces (known as filter cakes) can impede oil and gas recovery. Although chemical oxidizers are added to disrupt these accumulations, there is industrial interest in developing alternative, enzyme-based treatments. Little is known about CMC biodegradation under fracking conditions. Here, we enriched a methanogenic CMC-degrading culture and demonstrated its ability to enzymatically utilize CMC under the conditions that typify oil fields. Using the extracellular enzyme fraction from the culture, significant CMC viscosity reduction was observed between 50 and 80˚C, at salinities up to 20% (w/v) and at pH 5-8 compared to controls. Similar levels of viscosity reduction by extracellular enzymes were observed under oxic and anoxic conditions. This proof-of-concept study demonstrates that enzyme biotechnology holds great promise as a viable approach to treating CMC filter cakes under oilfield conditions.


Asunto(s)
Fracking Hidráulico , Biodegradación Ambiental , Biotecnología , Yacimiento de Petróleo y Gas , Polímeros
14.
Biosens Bioelectron ; 178: 113033, 2021 Apr 15.
Artículo en Inglés | MEDLINE | ID: mdl-33517230

RESUMEN

Over 27 million individuals are affected every year worldwide with central nervous system (CNS) injuries. These injuries include but are not limited to traumatic brain injury (TBI) and spinal cord injury (SCI). CNS injuries remain a significant public health concern which demands reliable tools for rapid, on-sight, on-field, and point-of-care diagnostic (POC) solutions. To address these challenges, we developed a low-cost, open-source, hand-held, portable, and POC detection technology, termed as MicroDrop (µDrop), which can simultaneously detect up to eight target biomolecules and display results in both analog and digital formats. The data acquired is stored wirelessly in a cloud server for further investigation and statistical analysis. Multiplexing capability of µDrop and immuno-biosensors detects and quantifies Cleaved-Tau Protein (C-Tau) and Neuron-Filament (NFL) proteins in the blood of TBI patients. Immuno-biosensors rapidly sense the two target proteins in less than 30 min, with µDrop and a conventional potentiostat. C-Tau and NFL were selectively detected with µDrop within the dynamic range of 10 pg/mL - 100 ng/mL and the sensitivity range of 47 µA/pg mm2 - 65 µA/pg mm2. Comparing the biosensing performance with enzyme-linked immunosorbent assays (ELISA) shows that the immuno-biosensors combined with µDrop could successfully differentiate between clinical controls and injured patients.


Asunto(s)
Técnicas Biosensibles , Lesiones Traumáticas del Encéfalo , Biomarcadores , Lesiones Traumáticas del Encéfalo/diagnóstico , Humanos , Neuronas , Proteínas tau
15.
ACS Appl Mater Interfaces ; 12(6): 6910-6923, 2020 Feb 12.
Artículo en Inglés | MEDLINE | ID: mdl-31971367

RESUMEN

The conceptualization of body-on-a-chip in 2004 resulted in a new approach for studying human physiology in three-dimensional culture. Despite pioneering works and the progress made in replicating human physiology on-a-chip, the stability, reliability, and preservation of cell-culture-treated microfluidic chips remain a challenge. The development of a reliable surface treatment technique to more efficiently and reproducibly modify microfluidic channels would significantly simplify the process of creating and implementing organ-on-a-chip (OOC) systems. In this work, a new flow-based coating technique using bioinspired polymers was implemented to create reliable, reproducible, ready-to-use microfluidic cell culture chips for OOC studies. Single-channel polydimethylsiloxane microfluidic chips were coated with the bioinspired catecholamine polymers, polydopamine (PDA) and polynorepinephrine (PNE), using a flow-based coating technique. The functionality of the resulting microfluidic chips was evaluated by extensive surface characterizations, at 130 °C, in the presence of various cleaning and culture media in static and flow conditions regularly used in OOCs and tested for shelf life by storing the coated microfluidic chips for 4 months at room temperature. Microfluidic chips coated with polycatecholamine were then seeded with the mouse cancer cell line Cath.a.differentiated (CAD) and with the normal human cerebral microvascular endothelial cell line human cerebral microvascular endothelial cells (hCMEC)/D3. Cell viability, cell phenotype, and cell functionality were assessed to evaluate the performance of both the coatings and the surface treatment technique. Both PDA- and PNE-coated microfluidic chips maintained high viability, phenotype, and functionality of CAD cells and hCMEC/D3 cells. In addition, CAD cells retained high viability when they were cultured in both the polymer-coated chips, which were stored at room temperature for up to 120 days. These results suggest that flow-based techniques to coat surfaces with polycatecholamines can be used to generate ready-to-use microfluidic OOC chips that offer long-term stability and reliability for the culture of cell types with application in pathophysiological studies and drug screening.


Asunto(s)
Catecolaminas/química , Células Endoteliales/citología , Microfluídica/métodos , Animales , Técnicas de Cultivo de Célula , Línea Celular Tumoral , Supervivencia Celular , Dimetilpolisiloxanos/química , Humanos , Indoles/química , Ratones , Microfluídica/instrumentación , Polímeros/química
16.
Stem Cells Int ; 2019: 4607461, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-31814836

RESUMEN

Mesenchymal stem cells (MSCs) have the capacity to differentiate towards bone, fat, and cartilage lineages. The most widely used culture and differentiation protocols for MSCs are currently limited by their use of serum-containing media and small-scale static culture vessels. Suspension bioreactors have multiple advantages over static culture vessels (e.g., scalability, control, and mechanical forces). This study sought to compare the formation and culture of 3D aggregates of human synovial fluid MSCs within suspension bioreactors and static microwell plates. It also sought to elucidate the benefits of these techniques in terms of productivity, cell number, and ability to generate aggregates containing extracellular matrix deposition. MSCs in serum-free medium were either (1) inoculated as single cells into suspension bioreactors, (2) aggregated using static microwell plates prior to being inoculated in the bioreactor environment, or (3) aggregated using microwell plates and kept in the static environment. Preformed aggregates that were size-controlled at inoculation had a greater tendency to form large, irregular super aggregates after a few days of suspension culture. The single MSCs inoculated into suspension bioreactors formed a more uniform population of smaller aggregates after a definite culture period of 8 days. Both techniques showed initial deposition of extracellular matrix within the aggregates. When the relationship between aggregate size and ECM deposition was investigated in static culture, midsized aggregates (100-300 cells/aggregate) were found to most consistently maximize sGAG and collagen productivity. Thus, this study presents a 3D tissue culture method, which avoids the clinical drawbacks of serum-containing medium that can easily be scaled for tissue culture applications.

17.
Biosens Bioelectron ; 145: 111715, 2019 Dec 01.
Artículo en Inglés | MEDLINE | ID: mdl-31561093

RESUMEN

Rapid, selective, and ultra-sensitive detection of brain and spinal cord injury markers in bodily fluids is an unmet clinical need. In this work, Polycatecholamine as a rich source of amine moieties was used for single-step fabrication of ultrasensitive immunosensors for the detection of Ubiquitin carboxyl-terminal hydrolase (UCHL-1) biomarker of brain and spinal cord injuries and address the clinical need. The surface of graphene electrodes was modified by electropolymerizing aqueous solution of dopamine (DA) and norepinephrine (NE) monomers for generating polycatecholamines nanofilms on the surface of graphene screen printed electrodes (GSPE) in a single functionalization step. Amine moieties of the polymer allowed immobilization of UCHL-1 antibody on the electrode. The single-step modification of GSPE offered a simple, ultrasensitive, and stable production of immunosensors for the detection of UCHL-1. The operational range of the UCHL-1 immunosensor developed with Polynorepinephrine pNE-modified is 0.1 pg mL-1 - 105 pg mL-1 (LOD: 1.91 pg mL-1), and 1 pg mL-1 - 105 pg mL-1 (LOD: 0.70 pg mL-1) with Polydopamine (pDA) modification, satisfying the clinical range. Both pNE and pDA modified immunosensors, detected UCHL-1 spiked in phosphate buffer saline, artificial cerebrospinal fluid, and serum. Along with the sensitive detections, selective performances were recorded in the above matrices in the presence of interfering neurotransmitters GABA and Glutamate as well as glial fibrillary acidic protein (GFAP). Upon testing clinical samples of spinal cord injury patients and healthy controls, both pNE and pDA immunosensors, delivered a comparable response for UCHL-1, thereby, making immunosensors useful for clinical settings.


Asunto(s)
Técnicas Biosensibles , Inmunoensayo , Traumatismos de la Médula Espinal/diagnóstico , Ubiquitina Tiolesterasa/aislamiento & purificación , Biomarcadores/sangre , Biomarcadores/líquido cefalorraquídeo , Catecolaminas/química , Dopamina/química , Grafito/química , Humanos , Norepinefrina/química , Ubiquitina Tiolesterasa/sangre , Ubiquitina Tiolesterasa/líquido cefalorraquídeo , Ácido gamma-Aminobutírico/metabolismo
18.
Stem Cells Int ; 2019: 3618217, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-31428158

RESUMEN

Several studies have demonstrated a potential interaction between mesenchymal stem cells (MSCs) and saccular aneurysms. In this study, we sought to determine whether allogenic bone marrow-derived MSCs had the ability to prevent aneurysm formation in a known rabbit elastase aneurysm model. MSCs were injected intravenously in experimental rabbits at the time of surgical creation and two weeks postcreation and compared with control rabbits receiving vehicle injection. Angiography was used to compare aneurysm measurements four weeks postcreation, and aneurysms were harvested for histological properties. Serum was collected longitudinally to evaluate cytokine alterations. Serum from control animals was also utilized to perform in vitro tests with MSCs to compare the effect of the serologic environment in animals with and without aneurysms on MSC proliferation and cytokine production. While aneurysm morphometric comparisons revealed no differences, significant cytokine alterations were observed in vitro and in vivo, suggesting both anti-inflammatory and proinflammatory processes were occurring in the presence of MSCs. Histological analyses suggested that tunica intima hyperplasia was inhibited in the presence of MSCs.

19.
AMB Express ; 9(1): 46, 2019 Apr 09.
Artículo en Inglés | MEDLINE | ID: mdl-30968201

RESUMEN

Non-hydrolyzed polyacrylamide (PAM) and partially hydrolyzed polyacrylamide (HPAM) are commonly used polymers in various industrial applications, including in oil and gas production operations. Understanding the microbial utilization of such polymers can contribute to improved recovery processes and help to develop technologies for polymer remediation. Microbial communities enriched from oilfield produced water (PW) and activated sludge from Alberta, Canada were assessed for their ability to utilize PAM and HPAM as nitrogen and carbon sources at 50 °C. Microbial growth was determined by measuring CO2 production, and viscosity changes and amide concentrations were used to determine microbial utilization of the polymers. The highest CO2 production was observed in incubations wherein HPAM was added as a nitrogen source for sludge-derived enrichments. Our results showed that partial deamination of PAM and HPAM occurred in both PW and sludge microbial cultures after 34 days of incubation. Whereas viscosity changes were not observed in cultures when HPAM or PAM was provided as the only carbon source, sludge enrichment cultures amended with HPAM and glucose showed significant decreases in viscosity. 16S rRNA gene sequencing analysis indicated that microbial members from the family Xanthomonadaceae were enriched in both PW and sludge cultures amended with HPAM or PAM as a nitrogen source, suggesting the importance of this microbial taxon in the bio-utilization of these polymers. Overall, our results demonstrate that PAM and HPAM can serve as nitrogen sources for microbial communities under the thermophilic conditions commonly found in environments such as oil and gas reservoirs.

20.
Stem Cells Int ; 2018: 8179075, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-30402112

RESUMEN

Ischemic diseases such as myocardial infarction, ischemic stroke, and critical limb ischemia are immense public health challenges. Current pharmacotherapy and surgical approaches are insufficient to completely heal ischemic diseases and are associated with a considerable risk of adverse effects. Alternatively, human mesenchymal stem cells (hMSCs) have been shown to exhibit immunomodulation, angiogenesis, and paracrine secretion of bioactive factors that can attenuate inflammation and promote tissue regeneration, making them a promising cell source for ischemic disease therapy. This review summarizes the pathogenesis of ischemic diseases, discusses the potential therapeutic effects and mechanisms of hMSCs for these diseases, and provides an overview of challenges of using hMSCs clinically for treating ischemic diseases.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...