Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 31
Filtrar
1.
JACC Case Rep ; 29(6): 102237, 2024 Mar 20.
Artículo en Inglés | MEDLINE | ID: mdl-38549851

RESUMEN

We report a case of a 16-year-old man in cardiogenic shock secondary to On-X mitral prosthesis dysfunction due to leaflet embolization through aortic mechanical prosthesis. He underwent an emergency redo mitral valve replacement and, a few days later, leaflet removal by open aortic surgery with full recovery.

2.
PLoS One ; 18(12): e0295408, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-38055674

RESUMEN

AIMS: IgE type immunoglobulins and their specific effector cells, mast cells (MCs), are associated with abdominal aortic aneurysm (AAA) progression. In parallel, immunoglobulin-producing B cells, organised in tertiary lymphoid organs (TLOs) within the aortic wall, have also been linked to aneurysmal progression. We aimed at investigating the potential role and mechanism linking local MCs, TLO B cells, and IgE production in aneurysmal progression. METHODS AND RESULTS: Through histological assays conducted on human surgical samples from AAA patients, we uncovered that activated MCs were enriched at sites of unhealed haematomas, due to subclinical aortic wall fissuring, in close proximity to adventitial IgE+ TLO B cells. Remarkably, in vitro the IgEs deriving from these samples enhanced MC production of IL-4, a cytokine which favors IgE class-switching and production by B cells. Finally, the role of MCs in aneurysmal progression was further analysed in vivo in ApoE-/- mice subjected to angiotensin II infusion aneurysm model, through MC-specific depletion after the establishment of dissecting aneurysms. MC-specific depletion improved intramural haematoma healing and reduced aneurysmal progression. CONCLUSIONS: Our data suggest that MC located close to aortic wall fissures are activated by adventitial TLO B cell-produced IgEs and participate to their own activation by providing support for further IgE synthesis through IL-4 production. By preventing prompt repair of aortic subclinical fissures, such a runaway MC activation loop could precipitate aneurysmal progression, suggesting that MC-targeting treatments may represent an interesting adjunctive therapy for reducing AAA progression.


Asunto(s)
Aneurisma de la Aorta Abdominal , Mastocitos , Humanos , Ratones , Animales , Mastocitos/metabolismo , Interleucina-4/metabolismo , Ratones Noqueados para ApoE , Aneurisma de la Aorta Abdominal/patología , Inmunoglobulina E/metabolismo , Modelos Animales de Enfermedad , Aorta Abdominal/patología , Angiotensina II/metabolismo , Ratones Endogámicos C57BL
4.
J Clin Med ; 12(8)2023 Apr 17.
Artículo en Inglés | MEDLINE | ID: mdl-37109238

RESUMEN

PURPOSE: The study sought to estimate the prevalence of primary non-aortic lesions (PNAL) unrelated to extension of aortic dissection (AD) in a cohort of patients with Marfan syndrome (MFS). METHODS: Adult patients presenting with pathogenic FBN1 mutations and an available pan-aortic contrast-enhanced CTA in eight French MFS clinics from April to October 2018 were included. Clinical and radiological data, particularly the presence of aortic lesions and PNAL (including aneurysm and ectasia), were retrospectively analyzed. RESULTS: Out of 138 patients, 28 (20.3%) had PNAL. In total, 27 aneurysms in 13 patients and 41 ectasias in 19 patients were reported mainly in the subclavian, iliac, and vertebral segments. Four patients (31%) with aneurysms and none with ectasia required prophylactic intervention during follow-up (median: 46 months). In multivariate analysis, factors associated with PNAL were history of AD (OR = 3.9, 95%CI: 1.3-12.1, p = 0.018), history of previous descending aortic surgery (OR = 10.3, 95%CI: 2.2-48.3, p = 0.003) and age (per 10 years OR = 1.6, 95%CI: 1.1-2.4, p = 0.008). CONCLUSION: PNAL is not rare in MFS patients with evolutive aortic disease. Natural history may differ between aneurysms and ectasia, emphasizing the need for standardized definitions and systematic screening for PNAL.

5.
Ann Vasc Surg ; 93: 38-47, 2023 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-36460175

RESUMEN

BACKGROUND: To assess midterm results of physician-modified stent grafts (PMSG) for the treatment of emergent complex abdominal and thoracoabdominal aortic aneurysms (TAAA) in high-risk patients. METHODS: All consecutive patients with emergent complex abdominal or TAAA undergoing PMSG technique between January 2012 and July 2019 were retrospectively included. Indications for PMSG were symptomatic aneurysms and rapidly growing aneurysms >70 mm. Ruptured aneurysms were excluded. RESULTS: Thirty-three patients (mean age: 74 +/- 11 years) were included. The mean aneurysm diameter was 76 +- 20 mm. Patients presented with TAAA (n = 20, 61%), complex abdominal aortic aneurysms (CAAA, n = 9, 27%), type I endoleak after previous endovascular aneurysm repair (n = 3, 9%) and intramural aortic hematoma (n = 1, 3%). Chimney technique was performed in addition to PMSG in seven cases (21%). Intraoperative adverse events were recorded in seven cases (35%) in the TAAA group and one case (11%) in the CAAA group. In-hospital mortality rate was 15% (n = 3) in the TAAA group and 11% (n = 1) in the CAAA group. Moderate to severe complications were recorded in 45% of cases (n = 15). Spinal cord ischemia occurred in two cases (6%, one case without residual deficit and one with minor motor deficit). One (3%) patient required transient hemodialysis. One patient presented with early aortic rupture and required an open conversion. The mean follow-up duration was 31 months (1-79). Overall survival estimates were 81.4% (95% confidence interval [CI]: 63.1.-91.2) at 1 year and 71.6% (95% CI: 52.6-84.1) at 2 years. Freedom from reintervention rates at 1 and 2 years were 61.2% (95% CI: 41.7-75.9) and 57.4% (95% CI: 37.9-72.8). Target vessel primary patency rates at 1 and 2 years were 99.2% (95% CI: 94.2-99.9) and 97.7% (95% CI: 90.7-99.4). CONCLUSIONS: PMSG for high-risk patients with complex aneurysms provided acceptable technical success and excellent target vessel patency rates but were associated with a 12% in-hospital mortality rate. Reinterventions were frequent. This technique should be limited to selected high-risk patients for whom the risk of rupture in the short-term is deemed too high to wait for graft manufacturing of custom-made device.


Asunto(s)
Aneurisma de la Aorta Abdominal , Aneurisma de la Aorta Torácica , Aneurisma de la Aorta Toracoabdominal , Implantación de Prótesis Vascular , Procedimientos Endovasculares , Humanos , Persona de Mediana Edad , Anciano , Anciano de 80 o más Años , Aneurisma de la Aorta Abdominal/diagnóstico por imagen , Aneurisma de la Aorta Abdominal/cirugía , Prótesis Vascular , Stents , Aneurisma de la Aorta Torácica/diagnóstico por imagen , Aneurisma de la Aorta Torácica/cirugía , Estudios Retrospectivos , Factores de Riesgo , Resultado del Tratamiento , Diseño de Prótesis , Factores de Tiempo
6.
BMC Pulm Med ; 22(1): 482, 2022 Dec 20.
Artículo en Inglés | MEDLINE | ID: mdl-36539752

RESUMEN

BACKGROUND: Airway complications are frequent after lung transplantation (LT), as they affect up to 23% of recipients. The implication of perioperative extracorporeal membrane oxygenation (ECMO) support and haemodynamic instability has never been specifically assessed. The first aim of this study was to explore the impact of perioperative ECMO support on bronchial anastomotic dehiscence (BAD) at Day 90 after LT. METHODS: This prospective observational monocentric study analysed BAD in all consecutive patients who underwent LT in the Bichat Claude Bernard Hospital, Paris, France, between January 2016 and May 2019. BAD visible on bronchial endoscopy and/or tomodensitometry was recorded. A univariate analysis was performed (Fisher's exacts and Mann-Whitney tests), followed by a multivariate analysis to assess independent risk factors for BAD during the first 90 days after LT (p < 0.05 as significant). The Paris North Hospitals Institutional Review Board approved the study. RESULTS: A total of 156 patients were analysed. BAD was observed in the first 90 days in 42 (27%) patients and was the main cause of death in 22 (14%) patients. BAD occurred during the first month after surgery in 34/42 (81%) patients. ECMO support was used as a bridge to LT, during and after surgery in 9 (6%), 117 (75%) and 40 (27%) patients, respectively. On multivariate analysis, ECMO as a bridge to LT (p = 0.04) and septic shock (p = 0.01) were independent risk factors for BAD. CONCLUSION: ECMO as a bridge to LT is an independent risk factor for BAD during the first 90 days after surgery. Close monitoring of bronchial conditions must be performed in these high-risk recipients.


Asunto(s)
Oxigenación por Membrana Extracorpórea , Trasplante de Pulmón , Humanos , Oxigenación por Membrana Extracorpórea/efectos adversos , Resultado del Tratamiento , Estudios Retrospectivos , Trasplante de Pulmón/efectos adversos , Factores de Riesgo
10.
Front Cardiovasc Med ; 9: 827357, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35360038

RESUMEN

Background: In Marfan syndrome (MFS), an aortic or peripheral arterial dilatation is usually the consequence of aortic dissection. Non-dissecting distal aortic and peripheral aneurysms (DAPA) are barely described. We sought to determine the incidence and prognostic impact of non-dissecting DAPA, requiring a surgical repair in a large population of patients with MFS. Methods: The patients referred to the French MFS reference center were included in a prospective database, and the patients treated for a non-dissecting DAPA between 2013 and 2020 were retrospectively reviewed. The first-line therapy was open surgery. The patients unfit for open repair or experiencing life-threatening complications underwent endovascular repair. Results: Among 1,575 patients with MFS, 19 (1.2%) were operated for 25 non-dissecting DAPA. The mean age was 42.4 ± 11.5 years. Non-dissecting DAPA involved the subclavian or axillary artery (n = 12), the descending or thoracoabdominal aorta (n = 6), the abdominal aorta andiliac arteries (n = 6), and the popliteal artery (n = 1). Open and endovascular repairs were performed in 22 and three cases, respectively. After a median follow-up of 54.2 months, no local recurrence was noticed and no secondary procedure was performed. Eight patients presented a new aortic event, including two aortic dissections and seven new aortic surgeries. Compared to the overall MFS population, the non-dissecting DAPA group presented a significantly higher risk of an aortic event (100 vs. 28%, p < 0.0001), a higher risk of aortic dissection (53 vs. 8%, p < 0.0001), and a higher rate of pejorative genetic mutations (68 vs. 40%, p = 0.011). Conclusion: Among the patients with MFS, the diagnosis of non-dissecting DAPA is infrequent but is associated with a significant adverse outcome, thus, advocating for a specific follow-up.

12.
Eur J Vasc Endovasc Surg ; 62(1): 55-63, 2021 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-33965329

RESUMEN

OBJECTIVE: To report the intra-operative adverse events (IOAEs) and the initial and one year outcomes of retrograde open mesenteric stenting (ROMS) using balloon expandable covered stents for acute and chronic mesenteric ischaemia. METHODS: Clinical data and outcomes of all consecutive patients treated with ROMS for acute and chronic mesenteric ischaemia at an intestinal stroke centre between November 2012 and September 2019 were reviewed. ROMS was performed using balloon expandable covered stents. Endpoints included IOAEs, in hospital mortality, post-operative complications, and re-interventions. One year overall survival, freedom from re-intervention, primary patency and assisted primary patency rates were analysed using the Kaplan-Meier time to event method. RESULTS: During the study period, 379 patients were referred to the centre for acute or chronic mesenteric ischaemia. Thirty-seven patients who underwent the ROMS procedure were included. All the patients had severe atherosclerotic mesenteric lesions. The ROMS technical success rate was 89% in this cohort. The rate of IOAEs was 19% and included four cases of retrograde recanalisation failure. All ROMS failures occurred in patients presenting with flush superior mesenteric artery occlusion and they were treated by mesenteric bypass. Ten patients (27%) underwent bowel resection, four of which resulted in a short bowel syndrome (11%). The in hospital mortality rate was 27%. Post-operative complications and re-intervention rates were 67% (n = 25) and 32% (n = 12), respectively. The median follow up was 20.2 months (interquartile range 29). The estimated one year overall survival for the cohort was 70.1% (95% confidence interval [CI] 52.5% - 82.2%). The estimated freedom from re-intervention at one year was 61.1% (95% CI 42.3 - 75.4). The one year primary patency and assisted primary patency rates were 84.54% (95% CI 63.34 - 94) and 92.4% (95% CI 72.8 - 98), respectively. CONCLUSION: ROMS procedures offer acceptable one year outcomes for mesenteric ischaemia but are associated with frequent stent related complications. Precise pre-operative planning, high quality imaging, and meticulous stent placement techniques may limit the occurrence of such events.


Asunto(s)
Procedimientos Endovasculares/efectos adversos , Complicaciones Intraoperatorias/epidemiología , Isquemia Mesentérica/cirugía , Oclusión Vascular Mesentérica/cirugía , Complicaciones Posoperatorias/epidemiología , Enfermedad Aguda/mortalidad , Enfermedad Aguda/terapia , Anciano , Enfermedad Crónica/mortalidad , Enfermedad Crónica/terapia , Procedimientos Endovasculares/instrumentación , Estudios de Factibilidad , Femenino , Mortalidad Hospitalaria , Humanos , Complicaciones Intraoperatorias/etiología , Masculino , Arterias Mesentéricas/diagnóstico por imagen , Arterias Mesentéricas/patología , Arterias Mesentéricas/cirugía , Isquemia Mesentérica/diagnóstico , Isquemia Mesentérica/mortalidad , Oclusión Vascular Mesentérica/diagnóstico , Oclusión Vascular Mesentérica/mortalidad , Persona de Mediana Edad , Complicaciones Posoperatorias/etiología , Reoperación/estadística & datos numéricos , Estudios Retrospectivos , Stents/efectos adversos , Resultado del Tratamiento
13.
Eur J Vasc Endovasc Surg ; 62(2): 204-213, 2021 08.
Artículo en Inglés | MEDLINE | ID: mdl-33994306

RESUMEN

OBJECTIVE: The aim was to describe initial outcomes of physician modified stent grafts using antegrade laser fenestrations and image fusion guidance (LEVAR) and company manufactured custom made (CM) stent grafts for the treatment of complex abdominal aortic aneurysms (CAAAs), thoraco-abdominal aortic aneurysms (TAAAs) and type I endoleaks (T1ELs). METHODS: This was a retrospective single centre study. All LEVAR and Zenith (Cook) CM stent graft procedures between 1 January 2012 and 31 December 2018 were reviewed. Endpoints included intra-operative adverse events (IOAEs), in hospital mortality, re-interventions, target vessel patency, and 12 month outcomes (overall survival, freedom from re-intervention, target vessel patency). Outcomes at 12 months were estimated using the Kaplan-Meier method. RESULTS: A hundred patients were identified and included in the study. All patients were deemed unfit for open repair. The cohort included 22 LEVAR and 78 CM stent grafts. LEVAR cases included painful aneurysms (n = 5), > 65 mm aneurysms (n = 10), anatomical constrains and/or presence of previous renal stents (n = 7) or cases declined by the manufacturer planning centre (n = 2). IOAEs were recorded in 41% of cases (n = 9) in the LEVAR group vs. 10% (n = 8, p = .002) in the CM group. The in hospital mortality rate in the LEVAR group was 9% (n = 2) vs. 4% (n = 3, p = .30) in the CM group. The median follow up duration was 22 months (7 - 38) in the LEVAR group and 28 months (11 - 78) in the CM group. The estimate of overall survival at one year was 91% in both groups. The freedom from re-intervention rate at one year was 58% in the LEVAR group vs. 87% in the CM group. The target vessel patency rates at one year were 95% in both groups. CONCLUSION: In high risk patients deemed unfit for open repair, LEVAR may provide satisfactory 12 month overall survival and target vessel patency rates, though reported IOAE, mortality, and re-interventions rates were high thus requiring close and extensive follow up.


Asunto(s)
Aneurisma de la Aorta Abdominal/cirugía , Aneurisma de la Aorta Torácica/cirugía , Prótesis Vascular , Endofuga/cirugía , Procedimientos Endovasculares/instrumentación , Anciano , Anciano de 80 o más Años , Prótesis Vascular/efectos adversos , Implantación de Prótesis Vascular/efectos adversos , Tomografía Computarizada de Haz Cónico , Endofuga/etiología , Procedimientos Endovasculares/efectos adversos , Procedimientos Endovasculares/métodos , Femenino , Fluoroscopía , Mortalidad Hospitalaria , Humanos , Complicaciones Intraoperatorias/etiología , Terapia por Láser , Masculino , Persona de Mediana Edad , Imagen Multimodal , Complicaciones Posoperatorias/etiología , Reoperación , Estudios Retrospectivos , Stents/efectos adversos , Cirugía Asistida por Computador , Tasa de Supervivencia , Grado de Desobstrucción Vascular
14.
J Vasc Surg ; 74(3): 902-909.e3, 2021 09.
Artículo en Inglés | MEDLINE | ID: mdl-33684478

RESUMEN

OBJECTIVE: Despite the continuing controversy of covered stents (CS) vs bare metal stents, the use of CS in mesenteric occlusive disease (MOD) has been recommended by expert centers. The aim of this study was to report midterm results with CS of the superior mesenteric artery. METHODS: Between January 2014 and October 2019, patients with MOD with a severe atheromatous stenosis or occlusion of the superior mesenteric artery treated by mesenteric CS were included. Clinical presentation included both acute mesenteric ischemia (AMI), chronic mesenteric ischemia, and asymptomatic patients planned for major surgery. Demographics, procedure details, and follow-up data were prospectively collected and retrospectively reviewed. Study end points included primary patency, primary assisted patency, and secondary patency. RESULTS: During the study period, 86 patients (mean age, 70 ± 9 years; 57% males) were included. Clinical presentation was AMI (n = 42 [49%]), chronic mesenteric ischemia (n = 31 [36%]), and asymptomatic (n = 13 [15%]). The technical success rate was 97%. A total of 96 stents were implanted, including 86 proximal CS (Advanta V12, n = 73; Lifestream, n = 13). The mean length and mean diameter of the CS were 31.5 ± 6.3 mm and 6.9 ± 0.5 mm, respectively. Additional distal bare metal stents were used in 10 patients (12%) to overcome a kinking (n = 9) or a dissection (n = 1) downstream of the CS. All postoperative deaths occurred in patients with AMI (n = 11, 13%). During a median follow-up of 15.6 months (95% confidence interval [CI], 15.6 ± 3.6 months), 12 patients (14%) underwent reinterventions for either stent misplacement (n = 3), stent recoil (n = 3), stent thrombosis (n = 2), de novo stenosis at the distal edge of the CS (n = 2), or gastric ischemia (n = 1). At 1 year, overall the primary patency, primary assisted patency, and secondary patency rates were 83% (95% CI, 83% ± 9%), 99% (95% CI, 99% ± 3%), and 99% (95% CI, 99% ± 3%), respectively. At 2 years, the overall primary patency, primary assisted patency, and secondary patency rates were 76% (95% CI, 76% ± 13%), 95% (95% CI, 95% ± 8%) and 95% (95% CI, 95% ± 8%), respectively. CONCLUSIONS: Mesenteric CS provide very satisfactory midterm results in patients with MOD, with an excellent primary assisted patency rate at 2 years, at the price of a significant reintervention rate.


Asunto(s)
Procedimientos Endovasculares/instrumentación , Arteria Mesentérica Superior/fisiopatología , Isquemia Mesentérica/terapia , Oclusión Vascular Mesentérica/terapia , Circulación Esplácnica , Stents , Anciano , Constricción Patológica , Bases de Datos Factuales , Procedimientos Endovasculares/efectos adversos , Procedimientos Endovasculares/mortalidad , Femenino , Humanos , Masculino , Arteria Mesentérica Superior/diagnóstico por imagen , Isquemia Mesentérica/diagnóstico por imagen , Isquemia Mesentérica/mortalidad , Isquemia Mesentérica/fisiopatología , Oclusión Vascular Mesentérica/diagnóstico por imagen , Oclusión Vascular Mesentérica/mortalidad , Oclusión Vascular Mesentérica/fisiopatología , Persona de Mediana Edad , Recurrencia , Retratamiento , Estudios Retrospectivos , Índice de Severidad de la Enfermedad , Factores de Tiempo , Resultado del Tratamiento , Grado de Desobstrucción Vascular
15.
Transplant Proc ; 53(2): 746-749, 2021 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-33549347

RESUMEN

BACKGROUND: Antibody-mediated rejection (AMR) is a major cause of graft loss. The development of donor-specific antibodies (DSAs) directed against the allogeneic HLA molecules expressed by the graft also leads to accelerated arteriosclerosis. CD31 is a protein expressed on endothelial and immune cells, ensuring homeostasis at this interface. When strong immune stimulation occurs, the regulatory function of CD31 is lost owing to cleavage of its extracellular portion. P8RI, a synthetic peptide that binds to the ectodomain of CD31, is able to restore the CD31 immunomodulatory function. In this study, we hypothesized that CD31 could represent an attractive molecular target in AMR and investigated whether P8RI could prevent the development of vascular antibody-mediated lesions. MATERIALS AND METHODS: A rat model of orthotopic aortic allograft was used, and P8RI was administered for 28 days. Circulating DSAs were quantified to assess the alloimmune humoral response, and histologic and immunohistochemical analyses of aortic allografts were performed to estimate antibody-mediated lesions in the allograft. RESULTS: Aorta-allografted rats receiving P8RI developed fewer DSAs than control animals (mean fluorescence intensity 344 vs 741). The density of nuclei in the media (3.4 x 10-5 vs 2.2 x 10-5 nuclei/px2) and media surface area (2.33 x 106 vs 2.02 x 106 px2) were higher in animals treated with P8RI than in control animals. CONCLUSIONS: These data support a therapeutic potential for molecules able to restore the CD31 signaling to fight AMR. P8RI, an agonist synthetic peptide targeting CD31, might prevent DSA production and have a beneficial effect in limiting arterial antibody-mediated lesions. CD31 agonists may become therapeutic tools to prevent and treat solid organ transplant arteriosclerosis.


Asunto(s)
Aloinjertos/inmunología , Aorta/trasplante , Rechazo de Injerto/prevención & control , Isoanticuerpos/inmunología , Molécula-1 de Adhesión Celular Endotelial de Plaqueta/agonistas , Animales , Modelos Animales de Enfermedad , Rechazo de Injerto/inmunología , Masculino , Péptidos/farmacología , Ratas , Trasplante Homólogo
16.
J Vasc Surg ; 74(1): 20-27, 2021 07.
Artículo en Inglés | MEDLINE | ID: mdl-33340705

RESUMEN

BACKGROUND: Open repair of type II thoracoabdominal aortic aneurysms (TAAAs) remains a challenging procedure. Staged procedures could decrease the incidence and severity of complications after complex aortic repair. In the present report, we have described a strategy using thoracic endovascular aortic repair (TEVAR) for proximal repair, followed by distal open repair. METHODS: From 2014 to 2018, 14 patients had undergone TEVAR, followed by distal open repair, for type II TAAAs. All patients should have a suitable proximal landing zone according to the current guidelines. In cases of chronic dissection, false lumen embolization was performed to achieve total exclusion. RESULTS: The mean patient age was 48 ± 15 years. Of the 14 patients, 5 had had Marfan syndrome (36%) and 6 had undergone previous aortic arch repair (43%). Ten patients had had a chronic dissection. The maximal aortic diameter was 73 ± 12 mm. The TEVAR technical success rate was 100%. The aortic length coverage was 211 ± 63 mm. The number of covered segmental arteries was 6 (range, 4-13). Two endoleaks were observed, one type Ib and one type II. The delay between TEVAR and open repair was 12 ± 8 weeks. Cerebrospinal fluid drainage was used in 13 patients. Six patients had undergone segmental artery reattachment during surgery. No spinal cord ischemic event was observed. One patient had died 5 weeks after open repair of multiple organ failure. During the 32 months of follow-up, no aortic-related deaths had occurred. No new aortic procedure was needed. The type Ib endoleak had resolved during open repair, and the type II TAAA had resolved spontaneously. The mean maximal thoracic aortic diameter had significantly decreased to 49 ± 8 mm (P < .0001). Aneurysmal shrinkage of ≥5 mm was observed in 13 patients (93%). CONCLUSIONS: Staged hybrid repair of type II TAAAs appears to be efficient, with low morbidity and mortality rates. This technique could improve postoperative outcomes after open repair, and TEVAR might have a role in ischemic preconditioning to protect against spinal cord ischemia.


Asunto(s)
Aneurisma de la Aorta Torácica/cirugía , Disección Aórtica/cirugía , Implantación de Prótesis Vascular , Procedimientos Endovasculares , Adulto , Disección Aórtica/diagnóstico por imagen , Disección Aórtica/mortalidad , Aneurisma de la Aorta Torácica/diagnóstico por imagen , Aneurisma de la Aorta Torácica/mortalidad , Implantación de Prótesis Vascular/efectos adversos , Implantación de Prótesis Vascular/mortalidad , Bases de Datos Factuales , Procedimientos Endovasculares/efectos adversos , Procedimientos Endovasculares/mortalidad , Femenino , Humanos , Masculino , Persona de Mediana Edad , Complicaciones Posoperatorias/etiología , Sistema de Registros , Estudios Retrospectivos , Medición de Riesgo , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento
19.
Ann Vasc Surg ; 68: 559-562, 2020 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-32561244

RESUMEN

BACKGROUND: The purpose of this study was to describe the use of the OUTBACK catheter to overcome aortic reentry issues in acute mesenteric ischemia (AMI) treated by retrograde open mesenteric stenting (ROMS). TECHNIQUE: The technique is demonstrated in two female patients presenting with late AMI related to flush occlusion of the superior mesenteric artery (SMA). In such cases of thrombotic AMI with clear preoperative evidence of intestinal necrosis, ROMS is the first-line revascularization technique in our intestinal stroke center. Following an open approach of the SMA through laparotomy, the SMA was punctured in a retrograde fashion. Retrograde mesenteric subintimal recanalization was initiated. In case of aortic reentry issue, the OUTBACK Elite (Cordis, Hialeah, Fl) catheter was advanced through the occlusion over a 0.014 guidewire. The aortic reentry was created by puncture of the aortic wall with the OUTBACK needle, positioned in the desired position. After low-profile balloon angioplasty of the reentry site and 0.035 guidewire exchange, ROMS was performed using balloon-expandable covered stent. CONCLUSIONS: The OUTBACK catheter appears to be a safe and effective tool to overcome aortic reentry issues in ROMS. This technical tip might therefore increase the technical success rate of challenging ROMS and decrease the need for bailout bypass in the septic context of AMI.


Asunto(s)
Angioplastia de Balón/instrumentación , Arteria Mesentérica Superior , Isquemia Mesentérica/terapia , Oclusión Vascular Mesentérica/terapia , Stents , Dispositivos de Acceso Vascular , Anciano , Angioplastia de Balón/efectos adversos , Femenino , Humanos , Arteria Mesentérica Superior/diagnóstico por imagen , Arteria Mesentérica Superior/fisiopatología , Isquemia Mesentérica/diagnóstico por imagen , Isquemia Mesentérica/fisiopatología , Oclusión Vascular Mesentérica/diagnóstico por imagen , Oclusión Vascular Mesentérica/fisiopatología , Diseño de Prótesis , Circulación Esplácnica , Resultado del Tratamiento , Grado de Desobstrucción Vascular
20.
Eur J Vasc Endovasc Surg ; 60(2): 253, 2020 08.
Artículo en Inglés | MEDLINE | ID: mdl-32278638
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...