Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
2.
Nat Commun ; 11(1): 6176, 2020 12 02.
Artículo en Inglés | MEDLINE | ID: mdl-33268779

RESUMEN

Rapid screening and low-cost diagnosis play a crucial role in choosing the correct course of intervention when dealing with highly infectious pathogens. This is especially important if the disease-causing agent has no effective treatment, such as the novel coronavirus SARS-CoV-2, and shows no or similar symptoms to other common infections. Here, we report a disposable silicon-based integrated Point-of-Need transducer (TriSilix) for real-time quantitative detection of pathogen-specific sequences of nucleic acids. TriSilix can be produced at wafer-scale in a standard laboratory (37 chips of 10 × 10 × 0.65 mm in size can be produced in 7 h, costing ~0.35 USD per device). We are able to quantitatively detect a 563 bp fragment of genomic DNA of Mycobacterium avium subspecies paratuberculosis through real-time PCR with a limit-of-detection of 20 fg, equivalent to a single bacterium, at the 35th cycle. Using TriSilix, we also detect the cDNA from SARS-CoV-2 (1 pg) with high specificity against SARS-CoV (2003).


Asunto(s)
COVID-19/diagnóstico , Técnicas de Amplificación de Ácido Nucleico/métodos , Animales , ADN Bacteriano/genética , Humanos , Mycobacterium avium subsp. paratuberculosis/genética , Análisis de Secuencia por Matrices de Oligonucleótidos/métodos , ARN Viral/genética , SARS-CoV-2/genética , Sensibilidad y Especificidad , Silicio
3.
Comput Methods Biomech Biomed Engin ; 20(16): 1678-1689, 2017 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-29164909

RESUMEN

Breathing parameters can be measured by motion capture systems by placing photo-reflective markers on the chest wall. A computational model is mandatory to compute the breathing volume and to calculate temporal and kinematical features by the gathered markers trajectories. Despite different methods based on different geometrical approaches can be adopted to compute volumes, no information about their differences in the respiratory evaluation are available. This study investigated the performances of four methods (conventional, prism-based, convex hull with boundary condition, based on Delaunay triangulation) using an optoelectronic motion capture system, on twelve healthy participants during 30 s of breathing. Temporal trends of volume traces, tidal volume values, and breathing durations were compared between methods and spirometry (used as reference instrument). Additionally, thoraco-abdominal motion patterns were compared between methods by analysing the compartmental contributions and their variability. Results shows comparable similarities between the volume traces obtained using spirometry, prism-based and conventional methods. Prism-based and convex hull with boundary condition methods show lower bias in tidal volumes estimation up to 0.06 L, compared to the conventional and Delaunay triangulation methods. Prism-based method shows maximum differences of 30 mL in the comparison of compartmental contributions to the total volume, by resulting in a maximum deviation of 1.6% in the percentage contribution analysis. In conclusion, our finding demonstrated the accuracy of the non-invasive MoCap-based breathing analysis with the prism-based method tested. Data provided in this study will lead researchers and clinicians in the computational method choice for temporal and volumetric breathing analysis.


Asunto(s)
Abdomen/fisiología , Electrónica/métodos , Movimiento (Física) , Óptica y Fotónica/métodos , Respiración , Tórax/fisiología , Fenómenos Biomecánicos , Simulación por Computador , Femenino , Humanos , Pulmón/fisiología , Masculino , Tamaño de los Órganos , Pletismografía , Espirometría , Estadística como Asunto , Pared Torácica/fisiología , Volumen de Ventilación Pulmonar/fisiología , Adulto Joven
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...