Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 49
Filtrar
1.
Biophys J ; 122(15): 3159-3172, 2023 08 08.
Artículo en Inglés | MEDLINE | ID: mdl-37393431

RESUMEN

Quantitative phase microscopy (QPM) represents a noninvasive alternative to fluorescence microscopy for cell observation with high contrast and for the quantitative measurement of dry mass (DM) and growth rate at the single-cell level. While DM measurements using QPM have been widely conducted on mammalian cells, bacteria have been less investigated, presumably due to the high resolution and high sensitivity required by their smaller size. This article demonstrates the use of cross-grating wavefront microscopy, a high-resolution and high-sensitivity QPM, for accurate DM measurement and monitoring of single microorganisms (bacteria and archaea). The article covers strategies for overcoming light diffraction and sample focusing, and introduces the concepts of normalized optical volume and optical polarizability (OP) to gain additional information beyond DM. The algorithms for DM, optical volume, and OP measurements are illustrated through two case studies: monitoring DM evolution in a microscale colony-forming unit as a function of temperature, and using OP as a potential species-specific signature.


Asunto(s)
Algoritmos , Fotometría , Animales , Microscopía Fluorescente , Bacterias , Mamíferos
2.
J Opt Soc Am A Opt Image Sci Vis ; 39(8): 1462-1467, 2022 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-36215591

RESUMEN

Replacing Maxwell equations by a scalar wave equation is often used in computational imaging to simulate the light-sample interaction. It significantly reduces the computational burden but provides field maps that are insensitive to the polarization of the incident field, provided the latter is constant throughout the sample. Here, we develop a scalar approximation that accounts for the polarization of the incident field. Comparisons with rigorous simulations show that this approach is more accurate than the classical scalar approximation with similar computational cost.

3.
Nat Mater ; 21(3): 269-271, 2022 03.
Artículo en Inglés | MEDLINE | ID: mdl-35241822
4.
Opt Express ; 29(3): 4230-4239, 2021 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-33771007

RESUMEN

Fourier ptychography tomography (FPT) is a novel computational technique for coherent imaging in which the sample is numerically reconstructed from images acquired under various illumination directions. FPT is able to provide three-dimensional (3D) reconstructions of the complex sample permittivity with an increased resolution compared to standard microscopy. In this work, FPT is applied to coherent anti-Stokes Raman scattering (CARS) imaging. We show on synthetic data that complex third-order susceptibilities can be reconstructed in 3D from a limited number of widefield CARS images. In addition, we observe that the non-linear interaction increases significantly the potential of CARS-FPT compared to linear FPT in terms of resolution. In particular, with a careful choice of the pump and Stokes beam directions, CARS-FPT is able to provide optical sectioning even in transmission configuration.

5.
Cell Rep Methods ; 1(1): 100009, 2021 05 24.
Artículo en Inglés | MEDLINE | ID: mdl-35474693

RESUMEN

Current super-resolution microscopy (SRM) methods suffer from an intrinsic complexity that might curtail their routine use in cell biology. We describe here random illumination microscopy (RIM) for live-cell imaging at super-resolutions matching that of 3D structured illumination microscopy, in a robust fashion. Based on speckled illumination and statistical image reconstruction, easy to implement and user-friendly, RIM is unaffected by optical aberrations on the excitation side, linear to brightness, and compatible with multicolor live-cell imaging over extended periods of time. We illustrate the potential of RIM on diverse biological applications, from the mobility of proliferating cell nuclear antigen (PCNA) in U2OS cells and kinetochore dynamics in mitotic S. pombe cells to the 3D motion of myosin minifilaments deep inside Drosophila tissues. RIM's inherent simplicity and extended biological applicability, particularly for imaging at increased depths, could help make SRM accessible to biology laboratories.


Asunto(s)
Procesamiento de Imagen Asistido por Computador , Iluminación , Animales , Microscopía Fluorescente/métodos , Drosophila
6.
Opt Lett ; 45(13): 3721-3724, 2020 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-32630938

RESUMEN

Biomedical imaging lacks label-free microscopy techniques able to reconstruct the contour of biological cells in solution, in 3D and with high resolution, as required for the fast diagnosis of numerous diseases. Inspired by computational optical coherence tomography techniques, we present a tomographic diffractive microscope in reflection geometry used as a synthetic confocal microscope, compatible with this goal and validated with the 3D reconstruction of a human effector T lymphocyte.


Asunto(s)
Imagenología Tridimensional , Microscopía Confocal/métodos , Linfocitos T/citología , Humanos , Fenómenos Ópticos
7.
Biomed Opt Express ; 11(2): 911-926, 2020 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-32206398

RESUMEN

Reflection phase imaging provides label-free, high-resolution characterization of biological samples, typically using interferometric-based techniques. Here, we investigate reflection phase microscopy from intensity-only measurements under diverse illumination. We evaluate the forward and inverse scattering model based on the first Born approximation for imaging scattering objects above a glass slide. Under this design, the measured field combines linear forward-scattering and height-dependent nonlinear back-scattering from the object that complicates object phase recovery. Using only the forward-scattering, we derive a linear inverse scattering model and evaluate this model's validity range in simulation and experiment using a standard reflection microscope modified with a programmable light source. Our method provides enhanced contrast of thin, weakly scattering samples that complement transmission techniques. This model provides a promising development for creating simplified intensity-based reflection quantitative phase imaging systems easily adoptable for biological research.

8.
Optica ; 7(5): 417-424, 2020 May.
Artículo en Inglés | MEDLINE | ID: mdl-34926725

RESUMEN

For sparse samples or in the presence of ambient light, the signal-to-noise ratio (SNR) performance of single-point-scanning coherent anti-Stokes Raman scattering (CARS) images is not optimized. As an improvement, we propose replacing the conventional CARS focus-point illumination with a periodically structured focus line while continuing to collect the transmitted CARS intensity on a single detector. The object information along the illuminated line is obtained by numerically processing the CARS signal recorded for various periods of the structured focus line. We demonstrate experimentally the feasibility of this spatial frequency modulated imaging (SPIFI) in CARS (SPIFI-CARS) and SHG (SPIFI-SHG) and identify situations where its SNR is better than that of the single-point-scanning approach.

9.
J Opt Soc Am A Opt Image Sci Vis ; 36(12): 2025-2029, 2019 Dec 01.
Artículo en Inglés | MEDLINE | ID: mdl-31873375

RESUMEN

The standard two-dimensional (2D) image recorded in bright-field fluorescence microscopy is rigorously modeled by a convolution process involving a three-dimensional (3D) sample and a 3D point spread function. We show on synthetic and experimental data that deconvolving the 2D image using the appropriate 3D point spread function reduces the contribution of the out-of-focus fluorescence, resulting in a better image contrast and resolution. This approach is particularly interesting for superresolution speckle microscopy, in which the resolution gain stems directly from the efficiency of the deconvolution of each speckle image.

10.
J Opt Soc Am A Opt Image Sci Vis ; 36(11): C1-C8, 2019 Nov 01.
Artículo en Inglés | MEDLINE | ID: mdl-31873684

RESUMEN

Estimating three-dimensional complex permittivity of a sample from the intensity recorded at the image plane of a microscope for various angles of illumination, as in optical Fourier ptychography microscopy, permits one to avoid the interferometric measurements of classical tomographic diffraction microscopes (TDMs). In this work, we present a general inversion scheme for processing intensities that can be applied to any microscope configuration (transmission or reflection, low or high numerical aperture), scattering regime (single or multiple scattering), or sample-holder geometries (with or without substrate). The inversion procedure is tested on a wide variety of synthetic experiments, and the reconstructions are compared to that of TDMs. In most cases, phaseless data yield the same result as complex data, thus paving the way toward a drastic simplification of TDM implementation.

11.
Opt Express ; 27(16): 23497-23514, 2019 Aug 05.
Artículo en Inglés | MEDLINE | ID: mdl-31510626

RESUMEN

We present a theoretical and numerical study of coherent anti-Stokes Raman scattering Fourier ptychography microscopy (CARS-FPM), a scheme that has not been considered so far in the previously reported CARS wide-field imaging schemes. In this approach, the distribution of the Raman scatterer density of the sample is reconstructed numerically from CARS images obtained under various angles of incidences of the pump or Stokes beam. Our inversion procedure is based on an accurate vectorial model linking the CARS image to the sample and yields both the real and imaginary parts of the susceptibility, the latter giving access to the Raman information, with an improved resolution.

12.
J Opt Soc Am A Opt Image Sci Vis ; 36(9): 1583, 2019 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-31503853

RESUMEN

This publisher's note corrects a typo in the title of J. Opt. Soc. Am. A36, C1 (2019)JOAOD60740-323210.1364/JOSAA.36.0000C1.

13.
J Opt Soc Am A Opt Image Sci Vis ; 36(4): 478-484, 2019 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-31044960

RESUMEN

In this paper, we introduce a formalism to determine the relationship between the full vectorial electric field existing at the object plane of a microscope and that existing at the image plane. The model is then used to quantitatively simulate, in both phase and intensity, the image of a radiating electric dipole placed either in a homogeneous medium or in the vicinity of a substrate. These simulations are compared with experimental measurements on single gold nanoparticles carried out by quadriwave lateral shearing interferometry.

14.
Opt Express ; 26(20): 26093-26105, 2018 Oct 01.
Artículo en Inglés | MEDLINE | ID: mdl-30469701

RESUMEN

We have developed a reflection tomographic microscope in which the sample is reconstructed from different holograms recorded under various angles and wavelengths of incidence. We present an iterative inversion algorithm based on a rigorous modeling of the wave-sample interaction that processes all the data simultaneously to estimate the sample permittivity distribution. We show that using several wavelengths permits a significant improvement of the reconstruction, especially along the optical axis.

15.
J Opt Soc Am A Opt Image Sci Vis ; 35(6): 1028-1033, 2018 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-29877348

RESUMEN

We present a numerical study of a microscopy setup in which the sample is illuminated with uncontrolled speckle patterns and the two-photon excitation fluorescence is collected on a camera. We show that, using a simple deconvolution algorithm for processing the speckle low-resolution images, this wide-field imaging technique exhibits resolution significantly better than that of two-photon excitation scanning microscopy or one-photon excitation bright-field microscopy.

16.
J Opt Soc Am A Opt Image Sci Vis ; 35(5): 748-754, 2018 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-29726491

RESUMEN

In this tutorial, we present a general model linking the data provided by any optical diffraction microscope to the sample permittivity. Our analysis is applicable to essentially all microscope configurations, in transmission or reflection mode, using scanning or full-field illumination, with or without interferometric measurements. We include also a generalization of our analysis to vector fields.

17.
Opt Lett ; 43(9): 2173-2176, 2018 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-29714782

RESUMEN

Total internal reflection microscopy is mainly used in its fluorescence mode and is the reference technique to image fluorescent proteins in the vicinity of cell membranes. Here, we show that this technique can easily become a phase microscope by simply detecting the coherent signal resulting from the interference between the field scattered by the probed sample and the total internal reflection. Moreover, combining several illumination angles permits generating synthetic aperture reconstructions with improved resolutions compared to standard label-free microscopy techniques.


Asunto(s)
Microscopía Fluorescente/métodos , Fenómenos Ópticos , Reconocimiento de Normas Patrones Automatizadas , Diseño de Equipo
18.
Opt Lett ; 42(20): 4183-4186, 2017 Oct 15.
Artículo en Inglés | MEDLINE | ID: mdl-29028043

RESUMEN

Fast imaging over large volumes can be obtained in a simple manner with extended-depth-of-field (EDOF) microscopy. A standard technique of Wiener deconvolution can correct for the blurring inherent in EDOF images. We compare Wiener deconvolution with an alternative, parameter-free technique based on the dual reconstruction of fluorescence and absorption layers in a sample. This alternative technique provides significantly enhanced reconstruction contrast owing to a quadratic positivity constraint that intrinsically favors sparse solutions. We demonstrate the advantages of this technique with mouse neuronal images acquired in vivo.


Asunto(s)
Encéfalo/diagnóstico por imagen , Microscopía Fluorescente/métodos , Animales , Fluorescencia , Ratones , Fenómenos Físicos
19.
IEEE Trans Image Process ; 26(5): 2480-2493, 2017 May.
Artículo en Inglés | MEDLINE | ID: mdl-28252396

RESUMEN

The blind structured illumination microscopy strategy proposed by Mudry et al. is fully re-founded in this paper, unveiling the central role of the sparsity of the illumination patterns in the mechanism that drives super-resolution in the method. A numerical analysis shows that the resolving power of the method can be further enhanced with optimized one-photon or two-photon speckle illuminations. A much improved numerical implementation is provided for the reconstruction problem under the image positivity constraint. This algorithm rests on a new preconditioned proximal iteration faster than existing solutions, paving the way to 3D and real-time 2D reconstruction.

20.
J Opt Soc Am A Opt Image Sci Vis ; 33(6): 1089-94, 2016 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-27409435

RESUMEN

We consider a fluorescence microscope in which several three-dimensional images of a sample are recorded for different speckle illuminations. We show, on synthetic data, that by summing the positive deconvolution of each speckle image, one obtains a sample reconstruction with axial and transverse resolutions that compare favorably to that of an ideal confocal microscope.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA