1.
J Comput Assist Tomogr ; 48(3): 343-353, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38595087

RESUMEN

PURPOSE: Accurate quantification of liver iron concentration (LIC) can be achieved via magnetic resonance imaging (MRI). Maps of liver T2*/R2* are provided by commercially available, vendor-provided, 3-dimensional (3D) multiecho Dixon sequences and allow automated, inline postprocessing, which removes the need for manual curve fitting associated with conventional 2-dimensional (2D) gradient echo (GRE)-based postprocessing. The main goal of our study was to investigate the relationship among LIC estimates generated by 3D multiecho Dixon sequence to values generated by 2D GRE-based R2* relaxometry as the reference standard. METHODS: A retrospective review of patients who had undergone MRI scans for estimation of LIC with conventional T2* relaxometry and 3D multiecho Dixon sequences was performed. A 1.5 T scanner was used to acquire the magnetic resonance studies. Acquisition of standard multislice multiecho T2*-based sequences was performed, and R2* values with corresponding LIC were estimated. The comparison between R2* and corresponding LIC estimates obtained by the 2 methods was analyzed via the correlation coefficients and Bland-Altman difference plots. RESULTS: This study included 104 patients (51 male and 53 female patients) with 158 MRI scans. The mean age of the patients at the time of scan was 15.2 (SD, 8.8) years. There was a very strong correlation between the 2 LIC estimation methods for LIC values up to 3.2 mg/g (LIC quantitative multiecho Dixon [qDixon; from region of interest R2*] vs LIC GRE [in-house]: r = 0.83, P < 0.01; LIC qDixon [from segmentation volume R2*] vs LIC GRE [in-house]: r = 0.92, P < 0.01); and very weak correlation between the 2 methods at liver iron levels >7 mg/g. CONCLUSION: Three-dimensional-based multiecho Dixon technique can accurately measure LIC up to 7 mg/g and has the potential to replace 2D GRE-based relaxometry methods.


Asunto(s)
Imagenología Tridimensional , Sobrecarga de Hierro , Hígado , Imagen por Resonancia Magnética , Humanos , Femenino , Masculino , Sobrecarga de Hierro/diagnóstico por imagen , Imagen por Resonancia Magnética/métodos , Estudios Retrospectivos , Adulto , Imagenología Tridimensional/métodos , Hígado/diagnóstico por imagen , Persona de Mediana Edad , Adulto Joven , Anciano , Interpretación de Imagen Asistida por Computador/métodos , Adolescente , Reproducibilidad de los Resultados , Hierro
2.
Children (Basel) ; 11(4)2024 Apr 12.
Artículo en Inglés | MEDLINE | ID: mdl-38671680

RESUMEN

PURPOSE: We aimed to characterize the fetal buccal fat pad (BFP) on magnetic resonance imaging (MRI) to determine the frequency and types of sequences on which the BFP demonstrates low signal intensity and determine any possible correlation with timing of the MRI during fetal development. MATERIALS AND METHODS: A retrospective review of all fetal MR studies was performed, and a pediatric radiologist blinded to the referring and final fetal diagnosis as well as outcome evaluated the included cases. A positive buccal fat pad sign (BFS) was recorded as present if a round, symmetric, and bilateral area was seen in the submalar region of the face with the following signal characteristics: T1 hyperintensity, low signal on echo planar imaging (EPI), low signal on true fast imaging with steady-state free precession (TRUFI), and with restriction on diffusion-weighted imaging (DWI). RESULTS: A total of one hundred sixty-seven (167) fetal MRI studies: one hundred fourteen (114) body (68%) and fifty-three (53) neuro (32%) scans were reviewed during the study period. The BFS was most commonly seen on EPI (63%) and TRUFI (49%) sequences. Substantial agreement between TRUFI and EPI (κ = 0.68; p < 0.01); moderate agreement between TRUFI and T1 (κ = 0.53; p < 0.01) as well as T1 and EPI (κ = 0.53; p < 0.01), and fair agreement between EPI and Diffusion (κ = 0.28; p < 0.01) was observed. The median gestational age (GA) was 24 weeks (IQR 22-30 weeks). The fetuses with a positive BFS were significantly older (mean GA of 27 weeks or higher) than those without, for each sequence. CONCLUSIONS: The focal low signal in the fetal buccal fat pad, termed the fetal BFS, is a commonly encountered normal finding in the majority of fetal MRI scans on TRUFI and EPI sequences. This finding may be related to the presence and development of brown adipose tissue in the buccal fat pad resulting in T2* effects, but further studies are needed in order to confirm this. Further work can incorporate any of the sensitive sequences demonstrating low signal in brown adipose tissue to map its distribution and development in the fetus and beyond.

3.
Pediatr Radiol ; 2024 Mar 15.
Artículo en Inglés | MEDLINE | ID: mdl-38488925

RESUMEN

Magnetic resonance imaging (MRI) is now an indispensable diagnostic tool in medicine due to its outstanding contrast resolution and absence of radiation exposure, enabling detailed tissue characterization and three-dimensional anatomical representation. This is especially important when evaluating individuals with congenital heart disease (CHD) who frequently require cardiac implantable electrical devices (CIEDs). While MRI safety issues have previously limited its use in patients with CIEDs, new advances have called these limitations into question. However, difficulties persist in the pediatric population due to the continued lack of specific safety data both related to imaging young children and the specific CIED devices they often require. This paper discusses MRI safety considerations related to imaging patients with CIEDs, investigates pediatric-specific problems, and describes thorough methods for safe MRI access, highlighting the significance of specialized institutional guidelines.

4.
AJR Am J Roentgenol ; 2024 Jan 03.
Artículo en Inglés | MEDLINE | ID: mdl-38170833

RESUMEN

Quantitative MRI and ultrasound biomarkers of liver fibrosis have become important tools in the diagnosis and clinical management of children with chronic liver disease (CLD). In particular, MR elastography (MRE) is now routinely performed in clinical practice to evaluate the liver for fibrosis. Ultrasound shear-wave elastography has also become widely performed for this purpose, especially in young children. These noninvasive methods are increasingly used to replace liver biopsy for the diagnosis, quantitative staging, and treatment monitoring of patients with CLD. Although ultrasound has advantages of portability and lower equipment cost, available evidence indicates that MRI may have greater reliability and accuracy in liver fibrosis evaluation. In this AJR Expert Panel Narrative Review, we describe how, why, and when to use MRI- and ultrasound-based elastography methods for liver fibrosis assessment in children. Practical approaches are discussed for adapting and optimizing these methods in children, with consideration of clinical indications, patient preparation, equipment requirements, acquisition technique, as well as pitfalls and confounding factors. Guidance is provided for interpretation and reporting, and representative case examples are presented.

5.
Curr Probl Diagn Radiol ; 53(2): 182-184, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-37891077

RESUMEN

This report describes the operational process of a big academic children's hospital's Radiology Scientific Review Committee, with a focus on its role in integrating radiology services into pediatric clinical research. We define the step-by-step workflow used to assess research proposals involving imaging and share insights from the past three years of data collection. Trends in modalities, radiologist involvement, and interpretation possibilities are outlined in the data. This systematic methodology provides essential resource allocation concepts and promotes high-quality pediatric clinical research.


Asunto(s)
Radiología , Niño , Humanos , Diagnóstico por Imagen , Estudios Prospectivos , Radiografía , Radiólogos , Radiología/métodos
6.
Pediatr Transplant ; 27(5): e14540, 2023 08.
Artículo en Inglés | MEDLINE | ID: mdl-37166372

RESUMEN

BACKGROUND: Noninvasive alternatives to biopsy for assessment of interstitial fibrosis and tubular atrophy (IFTA), the major determinant of kidney transplant failure, remain profoundly limited. Elastography is a noninvasive technique that propagates shear waves across tissues to measure their stiffness. We aimed to test utility of elastography for early detection of IFTA in pediatric kidney allografts. METHODS: We compared ultrasound (USE) and MR elastography (MRE) stiffness measurements, performed on pediatric transplant recipients referred for clinically indicated biopsies, and healthy controls. RESULTS: Ten transplant recipients (median age 16 years) and eight controls (median age 16.5 years) were enrolled. Three transplant recipients had "stable" allografts and seven had Banff Grade 1 IFTA. Median time from transplantation to biopsy was 12 months. Mean estimated glomerular filtration rate was 61.5 mL/min/1.73m2 by creatinine-cystatin-C CKiD equation at time of biopsy. Mean stiffness, calculated through one-way ANOVA, was higher for IFTA allografts (23.4 kPa USE/5.6 kPa MRE) than stable allografts (13.7 kPa USE/4.4 kPa MRE) and controls (9.1 kPa USE/3.6 kPa MRE). Pearson's coefficient between USE and MRE stiffness values was strong (r = .97). AUC for fibrosis prediction in transplanted kidneys was high for both modalities (0.91 USE and 0.89 MRE), although statistically nonsignificant (p > .05). Stiffness cut-off values for USE and MRE were 13.8 kPa and 4.6 kPa, respectively. Both values yielded a sensitivity of 100% but USE specificity (72%) was slightly higher than MRE (67%). CONCLUSION: Elastography shows potential for detection of low-grade IFTA in allografts although a larger sample is imperative for clinical validation.


Asunto(s)
Diagnóstico por Imagen de Elasticidad , Enfermedades Renales , Trasplante de Riñón , Enfermedades Pulmonares Intersticiales , Humanos , Niño , Adolescente , Proyectos Piloto , Fibrosis , Riñón/diagnóstico por imagen , Riñón/patología , Diagnóstico por Imagen de Elasticidad/métodos , Imagen por Resonancia Magnética/métodos , Cirrosis Hepática/patología
7.
Radiology ; 307(1): e221856, 2023 04.
Artículo en Inglés | MEDLINE | ID: mdl-36809220

RESUMEN

Accumulation of excess iron in the body, or systemic iron overload, results from a variety of causes. The concentration of iron in the liver is linearly related to the total body iron stores and, for this reason, quantification of liver iron concentration (LIC) is widely regarded as the best surrogate to assess total body iron. Historically assessed using biopsy, there is a clear need for noninvasive quantitative imaging biomarkers of LIC. MRI is highly sensitive to the presence of tissue iron and has been increasingly adopted as a noninvasive alternative to biopsy for detection, severity grading, and treatment monitoring in patients with known or suspected iron overload. Multiple MRI strategies have been developed in the past 2 decades, based on both gradient-echo and spin-echo imaging, including signal intensity ratio and relaxometry strategies. However, there is a general lack of consensus regarding the appropriate use of these methods. The overall goal of this article is to summarize the current state of the art in the clinical use of MRI to quantify liver iron content and to assess the overall level of evidence of these various methods. Based on this summary, expert consensus panel recommendations on best practices for MRI-based quantification of liver iron are provided.


Asunto(s)
Sobrecarga de Hierro , Hígado , Humanos , Hígado/diagnóstico por imagen , Hígado/patología , Sobrecarga de Hierro/diagnóstico por imagen , Sobrecarga de Hierro/patología , Imagen por Resonancia Magnética/métodos , Hierro , Biopsia
8.
Pediatr Radiol ; 53(7): 1324-1335, 2023 06.
Artículo en Inglés | MEDLINE | ID: mdl-36604317

RESUMEN

Neuroimaging protocols play an important role in the timely evaluation and treatment of pediatric stroke and its mimics. MRI protocols for stroke in the pediatric population should be guided by the clinical scenario and neurologic examination, with consideration of age, suspected infarct type and underlying risk factors. Acute stroke diagnosis and causes in pediatric age groups can differ significantly from those in adult populations, and delay in stroke diagnosis among children is a common problem. An awareness of pediatric stroke presentations and risk factors among pediatric emergency physicians, neurologists, pediatricians, subspecialists and radiologists is critical to ensuring timely diagnosis. Given special considerations related to unique pediatric stroke risk factors and the need for sedation in some children, expert consensus guidelines for the imaging of suspected pediatric infarct have been proposed. In this article the authors review standard and rapid MRI protocols for the diagnosis of pediatric stroke, as well as the key differences between pediatric and adult stroke imaging.


Asunto(s)
Accidente Cerebrovascular , Niño , Humanos , Accidente Cerebrovascular/diagnóstico por imagen , Imagen por Resonancia Magnética , Neuroimagen/métodos , Tomografía Computarizada por Rayos X , Infarto
9.
Urology ; 173: 149-152, 2023 03.
Artículo en Inglés | MEDLINE | ID: mdl-36638972

RESUMEN

OBJECTIVE: To describe the development and implementation of a process for creating accurate Pediatric genitourinary 3D modeling and printing with multiphase postcontrast imaging for surgical planning. MATERIALS AND METHODS: Additive manufacturing and 3D model present opportunities to support clinical planning, this manuscript's specific process and considerations for creating pediatric genitourinary 3D modeling to support urology. The process for creating the 3D models and prints covers 3 key aspects from image acquisition, imaging review and selection, and segmentation and modification (as needed). Each step is outlined with the key roles and procedures. RESULTS: The described case had digital and printed models prepared with references to the optimized imaging sequence for 3D modeling of Pediatric genitourinary. Case shared include complex genitourinary reconstruction and Kideny with Wilms tumors. CONCLUSION: The processes described have become a standard of practice for complex kidney tumors and exstrophy planning. The team continues to work on ever-changing improvements to make the best possible models to support clinical and surgical planning.


Asunto(s)
Neoplasias Renales , Urología , Humanos , Niño , Impresión Tridimensional , Neoplasias Renales/diagnóstico por imagen , Neoplasias Renales/cirugía , Sistema Urogenital , Urología/métodos , Imagenología Tridimensional/métodos , Modelos Anatómicos
10.
Tomography ; 8(5): 2508-2521, 2022 Oct 08.
Artículo en Inglés | MEDLINE | ID: mdl-36287808

RESUMEN

Objective: Magnetic resonance imaging (MRI) can accurately quantify liver iron concentration (LIC), eliminating the need for an invasive liver biopsy. Currently, the most widely used relaxometry methods for iron quantification are R2 and R2*, which are based on T2 and T2* acquisition sequences, respectively. We compared the rate of change of LIC as measured by the R2-based, FDA-approved commercially available third-party software with the rate of change of LIC measured by in-house analysis using R2*-relaxometry-based MR imaging in patients undergoing follow-up MRI scans for liver iron estimation. Methods: We retrospectively included patients who had undergone serial MRIs for liver iron estimation. The MR studies were performed on a 1.5T scanner; standard multi-slice, multi-echo T2- and T2*-based sequences were acquired, and LIC was estimated. The comparison between the rate of change of LIC by R2 and R2* values was performed via correlation coefficients and Bland−Altman difference plots. Results: One hundred and eighty-nine MR abdomen studies for liver iron evaluation from 81 patients (male: 38; female: 43) were included in the study. Fifty-nine patients had two serial scans, eighteen patients had three serial scans, three patients had four serial scans, and one patient had five serial scans. The average time interval between the first and last scans for each patient was 13.3 months. The average rates of change of LIC via R2 and R2* methods were −0.0043 ± 0.0214 and −0.0047 ± 0.012 mg/g per month, respectively. There was no significant difference in the rate of change of LIC observed between the two methods. Linearity between the rate of change of LIC measured by R2 (LIC R2) and R2* (LIC R2*) was strong, showing a correlation coefficient of r = 0.72, p < 0.01. A Bland−Altman plot between the rate of change of the two methods showed that the majority of the plotted variables were between two standard deviations. Conclusion: There was no significant difference in the rate of change of LIC detected between the R2 method and the R2* method that uses a gradient echo (GRE) sequence acquired with breath-hold. Since R2* is relatively faster and less prone to motion artifacts, R2*-derived LIC is recommended for iron homeostasis follow-up in patients with liver iron overload.


Asunto(s)
Hierro , Imagen por Resonancia Magnética , Humanos , Masculino , Femenino , Hierro/análisis , Estudios Retrospectivos , Imagen por Resonancia Magnética/métodos , Hígado/diagnóstico por imagen , Abdomen
11.
Clin Imaging ; 89: 147-154, 2022 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-35835018

RESUMEN

PURPOSE: Both congestive (patients post-Fontan hepatopathy) and congenital (patients with ARPKD) disease can lead to hepatic fibrosis and portal hypertension with eventual development of splenomegaly. We investigated liver and spleen stiffness as measured by MRE between post-Fontan, ARPKD patients and controls independent of organ volume. METHODS: Our study included 122 subjects (70 Fontan patients, 14 ARPKD patients, and 38 controls). The mean MRE liver and spleen stiffness values of Fontan patients and patients with ARPKD were compared to controls. Similarly, the liver and spleen volumes of the Fontan patients and patients with ARPKD were then compared to the volumes of controls. RESULTS: Post-Fontan and ARPKD patients, mean liver stiffness, mean liver volume as well as mean spleen stiffness and mean spleen volume were higher than mean liver stiffness, mean liver volume, mean spleen stiffness, and mean spleen volume of controls. While liver stiffness correlated to liver volume in controls, we found no correlation between stiffness and volume in either Fontan or ARPKD patients, which indicates MRE's ability to act as an independent biomarker. However, these findings are not true in the spleen, where there is significant association between volume and stiffness in patients with ARPKD, but not in Fontan patients or controls. CONCLUSION: Liver and spleen stiffness and volumes are significantly different among Fontan patients, ARPKD patients, and controls. Our findings suggest that beyond diagnosing fibrosis, MRE cut-off values could be disease-specific since not only the severity but the underlying pathology causing organ congestion or fibrosis influences MRE results.


Asunto(s)
Diagnóstico por Imagen de Elasticidad , Procedimiento de Fontan , Hipertensión Portal , Riñón Poliquístico Autosómico Recesivo , Diagnóstico por Imagen de Elasticidad/métodos , Humanos , Hígado/diagnóstico por imagen , Hígado/patología , Cirrosis Hepática/diagnóstico por imagen , Riñón Poliquístico Autosómico Recesivo/complicaciones , Riñón Poliquístico Autosómico Recesivo/patología , Estudios Retrospectivos , Bazo/diagnóstico por imagen , Bazo/patología
12.
J Magn Reson Imaging ; 55(2): 323-335, 2022 02.
Artículo en Inglés | MEDLINE | ID: mdl-33140551

RESUMEN

BACKGROUND: Phase-contrast (PC) MRI is a feasible and valid noninvasive technique to measure renal artery blood flow, showing potential to support diagnosis and monitoring of renal diseases. However, the variability in measured renal blood flow values across studies is large, most likely due to differences in PC-MRI acquisition and processing. Standardized acquisition and processing protocols are therefore needed to minimize this variability and maximize the potential of renal PC-MRI as a clinically useful tool. PURPOSE: To build technical recommendations for the acquisition, processing, and analysis of renal 2D PC-MRI data in human subjects to promote standardization of renal blood flow measurements and facilitate the comparability of results across scanners and in multicenter clinical studies. STUDY TYPE: Systematic consensus process using a modified Delphi method. POPULATION: Not applicable. SEQUENCE FIELD/STRENGTH: Renal fast gradient echo-based 2D PC-MRI. ASSESSMENT: An international panel of 27 experts from Europe, the USA, Australia, and Japan with 6 (interquartile range 4-10) years of experience in 2D PC-MRI formulated consensus statements on renal 2D PC-MRI in two rounds of surveys. Starting from a recently published systematic review article, literature-based and data-driven statements regarding patient preparation, hardware, acquisition protocol, analysis steps, and data reporting were formulated. STATISTICAL TESTS: Consensus was defined as ≥75% unanimity in response, and a clear preference was defined as 60-74% agreement among the experts. RESULTS: Among 60 statements, 57 (95%) achieved consensus after the second-round survey, while the remaining three showed a clear preference. Consensus statements resulted in specific recommendations for subject preparation, 2D renal PC-MRI data acquisition, processing, and reporting. DATA CONCLUSION: These recommendations might promote a widespread adoption of renal PC-MRI, and may help foster the set-up of multicenter studies aimed at defining reference values and building larger and more definitive evidence, and will facilitate clinical translation of PC-MRI. LEVEL OF EVIDENCE: 1 TECHNICAL EFFICACY STAGE: 1.


Asunto(s)
Riñón , Imagen por Resonancia Magnética , Consenso , Técnica Delphi , Humanos , Estudios Multicéntricos como Asunto , Circulación Renal
13.
Pediatr Radiol ; 52(2): 217-227, 2022 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-33856502

RESUMEN

Magnetic resonance imaging is widely available and accepted as the imaging method of choice for many pediatric body imaging applications. Traditionally, it has been used in a qualitative way, where the images are reported non-numerically by radiologists. But now MRI machines have built-in post-processing software connected to the scanner and the database of MR images. This setting enables and encourages simple quantitative analysis of MR images. In this paper, the author reviews the fundamentals of MRI and discusses the most common quantitative MRI techniques for body imaging: T1, T2, T2*, T1rho and diffusion-weighted imaging (DWI). For each quantitative imaging method, this article reviews the technique, its measurement mechanism, and selected clinical applications to body imaging.


Asunto(s)
Imagen de Difusión por Resonancia Magnética , Imagen por Resonancia Magnética , Niño , Humanos
14.
ACR Open Rheumatol ; 4(1): 74-82, 2022 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-34757697

RESUMEN

OBJECTIVE: To assess the feasibility of T2 mapping for evaluating pediatric SIJ cartilage at 3 Tesla (T) magnetic resonance imaging (MRI). METHODS: Healthy control subjects and adolescents with sacroiliitis underwent a 3T MRI dedicated pelvic protocol that included a T2 mapping sequence consisting of multislice, multiecho acquisition. Healthy control subjects were prospectively recruited from our primary care practices as part of a larger imaging study, whereas adolescents with sacroiliitis were recruited specifically for this study. Regions of interest (ROIs) were hand-drawn by a senior pediatric radiologist twice and a radiology fellow twice to calibrate and test reliability using the intraclass correlation coefficient (ICC). T2 relaxation time between control subjects and cases was compared using univariate linear regression. We tested the association of T2 relaxation time in adolescents with sacroiliitis with patient-reported outcomes and the Spondyloarthritis Research Consortium of Canada sacroiliac joint (SIJ) inflammation and structural scores using Pearson correlation coefficients. RESULTS: Fourteen subjects were evaluable (six control subjects: median age 13.7 years [interquartile range (IQR): 12.2-15.5], 67% male patients; eight cases: median age 17.4 years [IQR: 12.5-20], 88% male patients]. Acquisition time for T2 mapping sequences was approximately 6 minutes, and segmenting the ROI for each SIJ took approximately 3 minutes. The intrarater and inter-rater ICCs were 0.67 and 0.46, respectively, indicating good to fair reliability. There was a trend, albeit statistically insignificant, in longer median T2 relaxation time in cases (43.04 ms; IQR: 41.25-49.76 ms) versus healthy control subjects (40.0 ms; IQR: 38.9-48.6 ms). Although not statistically significant, cases with longer T2 relaxation time tended to occur with poorer patient-reported outcomes. Correlations with the SIJ inflammation and structural lesion scores were weak. CONCLUSION: T2 mapping of the SIJ cartilage in children was feasible and reliable. Larger controlled and longitudinal assessments are needed to assess the validity and utility of these measurements for routine clinical practice and trials.

15.
Abdom Radiol (NY) ; 46(10): 4709-4719, 2021 10.
Artículo en Inglés | MEDLINE | ID: mdl-34173844

RESUMEN

PURPOSE: To evaluate the correlation of 2D shape-based features with magnetic resonance elastography (MRE)-derived liver stiffness and portal hypertension (pHTN) in children with ARPKD-associated congenital hepatic fibrosis. METHODS: In a prospective IRB-approved study, 14 children with ARPKD (mean age ± SD = 13.8 ± 5.8 years) and 14 healthy controls (mean age ± SD = 13.7 ± 3.9 years) underwent liver MRE. A 2D region of interest (ROI) outlining the left liver lobe at the level of the abdominal aorta was drawn on sagittal T2-weighted images. Eight shape features (perimeter, major axis length, maximum diameter, perimeter to surface ratio (PSR), elongation, sphericity, minor axis length, and mesh surface) describing the 2D-ROI were calculated. Spearman's correlation was calculated between shape features and MRE-derived liver stiffness (kPa) (n = 28). Shape features were compared between participants with ARPKD with pHTN (splenomegaly and thrombocytopenia), (n = 4) and without pHTN (n = 8) using the Mann Whitney U test. Receiver operating characteristic (ROC) curves were generated to examine the diagnostic accuracy of shape features in identifying cases with liver stiffness > 2.9 kPa. RESULTS: In ARPKD participants and healthy controls, all eight shape features, except elongation, showed moderate to strong correlation with liver stiffness (kPa); the perimeter surface ratio had the strongest correlation (rho = - 0.75, p < 0.001). In ROC analysis, a cut-off of PSR ≤ 0.057 mm-1 gave 100% (95% CI: 59.0-100.0) sensitivity and 100% (95% CI: 83.9-100.0) specificity in identifying ARPKD participants with liver stiffness > 2.9 kPa, with an area under the ROC curve (AUC) of 1.0 (95% CI: 0.88-1.00). Individuals with pHTN had a lower median PSR (mean ± SD = 0.05 ± 0.01) than those without (0.07 ± 0.01; p = 0.027) with an AUC of 0.91 (95% CI: 0.60-0.99) in differentiating the participants with and without pHTN. CONCLUSION: Shape-based features of the left liver lobe show potential as non-invasive biomarkers of liver fibrosis and portal hypertension in children with ARPKD.


Asunto(s)
Diagnóstico por Imagen de Elasticidad , Hipertensión Portal , Riñón Poliquístico Autosómico Recesivo , Niño , Humanos , Hipertensión Portal/diagnóstico por imagen , Hipertensión Portal/patología , Hígado/diagnóstico por imagen , Hígado/patología , Cirrosis Hepática/patología , Riñón Poliquístico Autosómico Recesivo/diagnóstico por imagen , Estudios Prospectivos
16.
Pediatr Radiol ; 51(5): 724-735, 2021 May.
Artículo en Inglés | MEDLINE | ID: mdl-33860861

RESUMEN

The use of sedation and general anesthesia has facilitated the significant growth of MRI use among children over the last years. While sedation and general anesthesia are considered to be relatively safe, their use poses potential risks in the short term and in the long term. This manuscript reviews the reasons why MRI examinations require sedation and general anesthesia more commonly in the pediatric population, summarizes the safety profile of sedation and general anesthesia, and discusses an amalgam of strategies that can be implemented and can ultimately lead to the optimization of sedation and general anesthesia care within pediatric radiology departments.


Asunto(s)
Anestesia General , Servicio de Radiología en Hospital , Anestesia General/efectos adversos , Niño , Sedación Consciente/efectos adversos , Humanos , Imagen por Resonancia Magnética
18.
Pediatr Radiol ; 51(5): 716-723, 2021 May.
Artículo en Inglés | MEDLINE | ID: mdl-33871725

RESUMEN

Magnetic resonance imaging (MRI) is a powerful diagnostic tool that can be optimized to display a wide range of clinical conditions. An MRI system consists of four major components: a main magnet formed by superconducting coils, gradient coils, radiofrequency (RF) coils, and computer systems. Each component has safety considerations. Unless carefully controlled, the MRI machine's strong static magnetic field could turn a ferromagnetic object into a harmful projectile or cause vertigo and headache. Switching magnetic fields in the gradients evokes loud noises in the scanner, which can be mitigated by ear protection. Gradients also generate varying magnetic fields that can cause peripheral nerve stimulation and muscle twitching. Magnetic fields produced by RF coils deposit energy in the body and can cause tissue heating (with the potential to cause skin burns). In this review, we provide an overview of the components of a typical clinical MRI scanner and its associated safety issues. We also discuss how the relationship between the scanning parameters can be manipulated to improve image quality while ensuring a safe operational environment for the patients and staff. Understanding the strengths and limitations of these parameters can enable users to choose optimal techniques for image acquisition, apply them in clinical practice, and improve the diagnostic accuracy of an MRI examination.


Asunto(s)
Imagen por Resonancia Magnética , Ondas de Radio , Humanos
19.
Pediatr Radiol ; 51(5): 709-715, 2021 May.
Artículo en Inglés | MEDLINE | ID: mdl-33871724

RESUMEN

Establishing a magnetic resonance (MR) safety program is crucial to ensuring the safe MR imaging of pediatric patients. The organizational structure includes a core safety council and broader safety committee comprising all key stakeholders. These groups work in synchrony to establish a strong culture of safety; create and maintain policies and procedures; implement device regulations for entry into the MR setting; construct MR safety zones; address intraoperative MR concerns; guarantee safe scanning parameters, including complying with specific absorption rate limitations; adhere to national regulatory body guidelines; and ensure appropriate communication among all parties in the MR environment. Perspectives on the duties of the safety council members provide important insight into the organization of program oversite. Ultimately, the collective dedication and vigilance of all MR staff are crucial to the success of a safety program.


Asunto(s)
Comunicación , Imagen por Resonancia Magnética , Niño , Humanos , Espectroscopía de Resonancia Magnética
20.
Magn Reson Med ; 86(1): 69-81, 2021 07.
Artículo en Inglés | MEDLINE | ID: mdl-33565112

RESUMEN

PURPOSE: Chemical shift-encoded MRI (CSE-MRI) is well-established to quantify proton density fat fraction (PDFF) as a quantitative biomarker of hepatic steatosis. However, temperature is known to bias PDFF estimation in phantom studies. In this study, strategies were developed and evaluated to correct for the effects of temperature on PDFF estimation through simulations, temperature-controlled experiments, and a multi-center, multi-vendor phantom study. THEORY AND METHODS: A technical solution that assumes and automatically estimates a uniform, global temperature throughout the phantom is proposed. Computer simulations modeled the effect of temperature on PDFF estimation using magnitude-, complex-, and hybrid-based CSE-MRI methods. Phantom experiments were performed to assess the temperature correction on PDFF estimation at controlled phantom temperatures. To assess the temperature correction method on a larger scale, the proposed method was applied to data acquired as part of a nine-site multi-vendor phantom study and compared to temperature-corrected PDFF estimation using an a priori guess for ambient room temperature. RESULTS: Simulations and temperature-controlled experiments show that as temperature deviates further from the assumed temperature, PDFF bias increases. Using the proposed correction method and a reasonable a priori guess for ambient temperature, PDFF bias and variability were reduced using magnitude-based CSE-MRI, across MRI systems, field strengths, protocols, and varying phantom temperature. Complex and hybrid methods showed little PDFF bias and variability both before and after correction. CONCLUSION: Correction for temperature reduces temperature-related PDFF bias and variability in phantoms across MRI vendors, sites, field strengths, and protocols for magnitude-based CSE-MRI, even without a priori information about the temperature.


Asunto(s)
Hígado , Protones , Imagen por Resonancia Magnética , Reproducibilidad de los Resultados , Temperatura