Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
J Clin Med ; 11(21)2022 Oct 31.
Artículo en Inglés | MEDLINE | ID: mdl-36362710

RESUMEN

Background: The hyperventilation provocation test (HPTest) is a diagnostic tool for idiopathic hyperventilation syndrome (HVS), encountered in some long-COVID patients. However, interpretation of the HPTest remains unclear regarding the relevant PETCO2 values to focus on and whether subjective symptoms should be considered. This study aimed to re-evaluate objective HPTest results for diagnosing HVS by determining accurate PETCO2 kinetics in two groups of patients previously screened via the Nijmegen questionnaire (NQ). Methods: The kinetics of PETCO2 during the HPTest were mathematically modeled and compared between 37 HVS patients (NQ ≥23/64) and 37 healthy controls (NQ <23/64) matched for gender, age, and body dimensions. AUC values with sensitivity and specificity were calculated, and analysis was monitored in a validation cohort of 152 routine HPTests. Results: A threshold value of a less than 12.8 mmHg increment of PETCO2 at the 5th minute of the recovery phase of the HPTest diagnosed HVS patients with excellent sensitivity (0.92) and specificity (0.84). These results were confirmed in the validation cohort, highlighting the presence of 24% false positives/negatives when diagnosing on the basis of complaints in the NQ. Conclusions: For HVS diagnosis, we suggest considering the HPTest, which can more reliably reflect the mechanisms of CO2 homeostasis and the response of the respiratory center to a stimulus, regardless of the subjective onset of symptoms.

2.
Eur J Intern Med ; 22(6): e115-8, 2011 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-22075295

RESUMEN

BACKGROUND: Several phenotypes are described in COPD. OBJECTIVES: To assess if COPD patients with Hoover's sign (HS) belong to a particular phenotype. METHODS: All consecutive COPD patients with varying degree of airflow obstruction that came for lung function testing in one university hospital were prospectively assessed, using clinical and magnetometer detection of HS, body mass index (BMI), St. George's Respiratory Questionnaire for health-related quality of life, six-minute-walk test (6MWT) with inspiratory capacity (IC) measurements and expiratory flow limitation (EFL) detection. Previous exacerbations were also reported. RESULTS: 82 patients were studied. Magnetometers confirmed HS in 56 of them, of which 79% (44/56) were detected by clinical assessment. HS (+) patients were older (64 ± 10 vs 59 ± 10 years, p=0.03), had a higher BMI (26 ± 5 vs 23 ± 4, p=0.04), a lower FEV1 (53% ± 18% vs 63% ± 18% pred, p=0.02) and a higher IC decrease at the end of 6MWT, (-19 ± 2 vs -7 ± 4% pred, p=0.003). A larger proportion of HS (+) patients also reported severe exacerbations during the past 2 years (39% vs 12% p=0.01). There was no statistical evidence that HS was related to hyperinflation and/or EFL. CONCLUSION: The very simple clinical HS allows identifying a particular population of COPD patients of older age and higher BMI with a more severe airflow obstruction, increased dynamic hyperinflation during exercise and higher exacerbation frequency. These characteristics were not linked to hyperinflation or EFL.


Asunto(s)
Enfermedad Pulmonar Obstructiva Crónica/diagnóstico , Enfermedad Pulmonar Obstructiva Crónica/fisiopatología , Índice de Severidad de la Enfermedad , Factores de Edad , Anciano , Índice de Masa Corporal , Tolerancia al Ejercicio/fisiología , Femenino , Flujo Espiratorio Forzado/fisiología , Humanos , Capacidad Inspiratoria/fisiología , Magnetometría , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Estudios Prospectivos , Calidad de Vida , Costillas/fisiología , Encuestas y Cuestionarios
3.
Pediatr Infect Dis J ; 30(9): 812-3, 2011 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-21378593
4.
J Sleep Res ; 20(1 Pt 2): 201-6, 2011 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-20561176

RESUMEN

To date, the clinical use of unattended home-based polysomnography (PSG) is not recommended. To assess whether sleep efficiency is better at home, we have performed a prospective, crossover, single-blind study comparing unattended home- versus attended in-hospital PSG in a population referred for high clinical suspicion of obstructive sleep apnoea syndrome (OSA). Within 2 weeks, all the patients underwent both PSG performed by the same sleep technician, which were analysed by another blinded technician. Payments for each procedure were also calculated. Sixty-six patients (mean age: 49±13 years; mean body mass index: 30±7; mean Epworth Sleepiness Scale: 10±5) were included. The quality of recordings was poor in 1.5% of the attended PSG versus 4.7% for unattended PSG (P=0.36). Sleep efficiency at home was better (82% versus 75%, P<0.001), and sleep duration longer (412 min versus 365 min, P<0.001). Sleep latency was also shorter at home (28 min versus 45 min, P=0.004), and patients spent more time in rapid eye movement sleep (19% versus 16%, P=0.006). Apnoea-hypopnoea index (23 versus 26, P=0.08) was similar at home and in the sleep lab. Sixty-seven per cent of patients preferred home-based PSG. PSG payment was also lower at home (268 Euros versus 1057 Euros). We conclude that home-based PSG is associated with a better sleep efficiency. It also appears as feasible and reliable in patients with high preclinical suspicion for OSA. It is also more comfortable for the patients whose sleep efficiency is better and allows cost saving related to the absence of hospitalization.


Asunto(s)
Polisomnografía/métodos , Sueño/fisiología , Costos y Análisis de Costo , Estudios Cruzados , Femenino , Humanos , Pacientes Internos/psicología , Masculino , Persona de Mediana Edad , Pacientes Ambulatorios/psicología , Polisomnografía/economía , Estudios Prospectivos , Respiración , Método Simple Ciego , Sueño REM/fisiología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA