1.
Sensors (Basel) ; 23(13)2023 Jul 07.
Artículo en Inglés | MEDLINE | ID: mdl-37448058

RESUMEN

Stable and uniform beams with low divergence are required in particle accelerators; therefore, beyond the accelerated current, measuring the beam current spatial uniformity and stability over time is necessary to assess the beam performance, since these parameters affect the perveance and thus the beam optics. For high-power beams operating with long pulses, it is convenient to directly measure these current parameters with a non-intercepting system due to the heat management requirement. Such a system needs to be capable of operating in a vacuum in the presence of strong electromagnetic fields and overvoltages, due to electrical breakdowns in the accelerator. Finally, the measure of the beam current needs to be efficiently integrated into a pulse file with the other relevant plant parameters to allow the data analyses required for beam optimization. This paper describes the development, design and commissioning of such a non-intercepting system, the so-called beamlet current monitor (BCM), aimed to directly measure the electric current of a particle beam. In particular, the layout of the system was adapted to the SPIDER experiment, the ion source (IS) prototype of the heating neutral beam injectors (HNB) for the ITER fusion reactor. The diagnostic is suitable to provide the electric current of five beamlets from DC up to 10 MHz.


Asunto(s)
Análisis de Datos , Electricidad , Campos Electromagnéticos , Frecuencia Cardíaca , Calefacción
2.
Int J Mol Sci ; 23(18)2022 Sep 15.
Artículo en Inglés | MEDLINE | ID: mdl-36142664

RESUMEN

Non-thermal plasma technology is increasingly being applied in the plant biology field. Despite the variety of beneficial effects of plasma-activated water (PAW) on plants, information about the mechanisms of PAW sensing by plants is still limited. In this study, in order to link PAW perception to the positive downstream responses of plants, transgenic Arabidopsis thaliana seedlings expressing the Ca2+-sensitive photoprotein aequorin in the cytosol were challenged with water activated by low-power non-thermal plasma generated by a dielectric barrier discharge (DBD) source. PAW sensing by plants resulted in the occurrence of cytosolic Ca2+ signals, whose kinetic parameters were found to strictly depend on the operational conditions of the plasma device and thus on the corresponding mixture of chemical species contained in the PAW. In particular, we highlighted the effect on the intracellular Ca2+ signals of low doses of DBD-PAW chemicals and also presented the effects of consecutive plant treatments. The results were discussed in terms of the possibility of using PAW-triggered Ca2+ signatures as benchmarks to accurately modulate the chemical composition of PAW in order to induce environmental stress resilience in plants, thus paving the way for further applications in agriculture.


Asunto(s)
Aequorina , Arabidopsis , Calcio/farmacología , Calcio de la Dieta/farmacología , Citosol , Agua/farmacología
3.
Materials (Basel) ; 16(1)2022 Dec 26.
Artículo en Inglés | MEDLINE | ID: mdl-36614543

RESUMEN

SPIDER is the 100 keV full-size Negative Ion Source prototype of the ITER Neutral Beam Injector, operating at Consorzio RFX in Padova, Italy. The largest Negative Ion Source in the world, SPIDER generates an RF driven plasma from which Deuterium or Hydrogen negative ions are produced and extracted. At the end of 2021, a scheduled long-term shutdown started to introduce major modifications and improvements aiming to solve issues and drawbacks identified during the first three years of SPIDER operations. The first action of the shutdown period was the disassembly and characterization of the SPIDER beam source after removal from the vacuum vessel and its placement inside the clean room. Each component was carefully assessed and catalogued, following a documented procedure. Some source components, i.e., the Plasma Grid, Extraction Grid and Bias Plate, revealed the presence of different and non-uniform red, white and green coatings that might be correlated to back-streaming positive ions impinging on grid surfaces, electrical discharges and caesium evaporation. Thus, several analyses have been carried out to understand the nature of such coatings, with the study still ongoing. The evidence of caesium evaporation and deposition on molybdenum-coated SPIDER components, such as the formation of oxides and hydroxides, is demonstrated through surface characterization analyses with the use of the Scanning Electron Microscope (SEM), X-ray Diffraction (XRD) and X-ray Photoelectron Spectroscopy (XPS).

4.
Rev Sci Instrum ; 91(3): 033301, 2020 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-32259972

RESUMEN

The full-size ITER ion source prototype SPIDER (Source for the Production of Ions of Deuterium Extracted from a Radio frequency plasma) has recently started beam operation, whose objective is to produce 100 keV, 60 A hydrogen negative ions for 1 h. The source is presently operated in the volume regime, and the beam power is consequently limited. In such a configuration, the high resolution calorimeter STRIKE (Short-Time Retractable Instrumented Kalorimeter Experiment), even though uncooled, may be used instead of the SPIDER beam dump without limiting the beam-on time. STRIKE is formed by unidirectional carbon fiber-carbon matrix (CFC) composite tiles that are exposed to the beam while their temperature is recorded by using two infra-red cameras. This setup, thanks to the moderate broadening of the temperature profile guaranteed by the anisotropy of CFC, allows for the determination of detailed features of the beam current distribution (spatial resolution is about 2 mm). Furthermore, positively biasing the CFC tiles permits a direct electrical measurement of the negative ion beam current. Besides the total beam current and beam uniformity, which can be retrieved both by calorimetry and electrical measurement, beamlet divergence and deflection can be determined by infra-red thermography. This contribution describes the characterization of the SPIDER negative ion beam as a function of the source and accelerator parameters by means of the diagnostic calorimeter STRIKE in the volume regime.

5.
Rev Sci Instrum ; 91(1): 013328, 2020 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-32012576

RESUMEN

Low divergence negative ion beams are crucial for the development of ITER-like fusion reactors. SPIDER is the prototype beam source of the ITER heating neutral beam injector, and it recently started beam acceleration, up to a voltage of 30 kV. The main diagnostics used to measure beamlet divergence are a movable diagnostic calorimeter (STRIKE), which gives the thermal footprint of the beamlets; beam emission spectroscopy; and visible imaging. These systems do not allow a direct measurement of single beamlet phase-space distribution, which is useful for comparison with numerical simulations and to estimate accelerator performances. To this purpose, a movable Allison type emittance scanner for the SPIDER negative ion beam was developed and proposed for the installation on the STRIKE supporting structure. This paper describes the numerical analyses performed to dimension the mechanical and electrical components, such as the Faraday cup and the slits. An analytical approach based on the integration of an arbitrary phase-space distribution was adopted in order to simulate the device performances. The constraints due to the operation in a high heat load environment are discussed.

6.
Rev Sci Instrum ; 87(2): 02B311, 2016 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-26932039

RESUMEN

The negative-ion accelerator for the MITICA neutral beam injector has been designed and optimized in order to reduce the thermo-mechanical stresses in all components below limits compatible with the required fatigue life. However, deviation from the expected beam performances can be caused by "off-normal" operating conditions of the accelerator. The purpose of the present work is to identify and analyse all the "off-normal" operating conditions, which could possibly become critical in terms of thermo-mechanical stresses or of degradation of the optical performances of the beam.

7.
Rev Sci Instrum ; 79(10): 10F307, 2008 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-19044620

RESUMEN

The neutral beam injectors for ITER are designed to deliver hydrogen or deuterium atoms accelerated at 1 MV for a total power of 34 MW. Design of the neutral beam and of the ion source test facilities is presently ongoing. Among the various activities, also the definition and assessment of necessary diagnostics are being carried out. Within this framework, requirements and constraints of the diagnostic system will be discussed in the present paper with the aim of providing data relevant for protection, operation, characterization, and improvement of the performances of the test facilities. The definition of the most suitable locations for the diagnostics and of their preliminary integration into the mechanical design will be proposed. Proposals for the extraction of signals from the high voltage components will also be presented.