Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 29
Filtrar
1.
AJOG Glob Rep ; 4(1): 100325, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38586615

RESUMEN

BACKGROUND: Fetal cardiology has shown a rapid development in the past decades. Fetal echocardiography is not only used for the detection of structural anomalies but also to assess fetal cardiac function. Assessment of the fetal cardiac function is performed mostly in the second and third trimesters. The study of fetal cardiac function at the end of first trimester has not been investigated properly, and there is a lack of reference values at early gestational weeks. OBJECTIVE: This study aimed to assess if the measurement of time-related parameters of cardiac function in the left ventricle of the fetal heart is feasible and reproducible at the end of the first trimester. If possible, we provide nomograms of these parameters from 11 to 13+6 gestational weeks. STUDY DESIGN: We conducted a prospective observational study from March to September 2022. The study was carried out in 2 hospitals (Hospital Universitari Dexeus, Barcelona, and Hospital VITAHS 9 Octubre, Valencia, Spain). The scans were performed by 3 specialists in fetal medicine. The exclusion criteria were fetal cardiac rhythm abnormalities, abnormal nuchal translucency, abnormal ductus venosus, fetal malformations, stillbirth, estimated fetal weight <10 percentile, diabetes, and gestational hypertensive disorders. The cardiac function parameters studied in the left ventricle were isovolumetric contraction time, isovolumetric relaxation time, ejection time, filling time, cycle time, myocardial performance index, ejection time fraction, and filling time fraction. We study the feasibility and intra- and interobserver reproducibility of these parameters using the interclass correlation coefficient. Nomograms were created and the percentiles of the values of the different parameters were calculated. RESULTS: A total of 409 cases were recruited but only 296 could be included in the statistical analysis once the exclusion criteria were applied. The intraobserver reproducibility study was excellent (interclass correlation coefficient >0.900), and the interobserver reproducibility study was good (interclass correlation coefficient >0.700). The data regression analysis showed that cycle time, filling time, isovolumetric contraction time, and filling time fraction increased with gestational age, whereas ejection time fraction decreased with gestational age and myocardial performance index (mean, 0.43±0.08), isovolumetric relaxation time (mean, 0.04±0.01), and ejection time (mean, 0.16±0.01) remained constant from 11 to 13 weeks. CONCLUSION: The study of fetal cardiac function is feasible and reproducible at 11 to 13+6 gestational weeks. Nomograms of the studied parameters are provided.

2.
Prenat Diagn ; 2024 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-38161311

RESUMEN

OBJECTIVES: To determine the prevalence of abnormalities of the corpus callosum (AbnCC) in a non-selected population, to propose a systematic screening protocol for AbnCC in all populations through direct assessment, and to describe the follow-up and prognosis of all AbnCC cases diagnosed in our clinical setting. METHODS: This was a retrospective review of the prevalence of AbnCC over 11 years. We included a sagittal assessment of the corpus callosum (CC) in the second-trimester scan. AbnCC was classified into complete agenesis of CC (ACC) and dysgenesis of CC (DCC; including small, partial agenesis, thick and with lipoma). RESULTS: Of the 38,586 second-trimester scans performed during our screening, 43 cases of AbnCC were detected (prevalence of 0.8/1000). Of the AbnCC cases, 10 cases were identified as ACC (29.40%) and 24 as DCC (70.59%). Follow-up investigations showed that in the 43 cases with AbnCC, 76.5% had other associated ultrasound abnormalities, 26.5% had genetic abnormalities, 11.8% had other MRI abnormalities, and 25% of the children had neurodevelopmental delays (8.8% of the total), which were severe in only one case. CONCLUSIONS: AbnCC is found in approximately 0.8/1000 of cases in an unselected population. The findings suggest that systematic and direct assessment of the CC as part of screening ultrasound in the second trimester of gestation should be recommended as a routine practice.

3.
Can J Cardiol ; 2023 Nov 25.
Artículo en Inglés | MEDLINE | ID: mdl-38013065

RESUMEN

BACKGROUND: Percutaneous mitral paravalvular leak (PVL) closure techniques are an effective and safe alternative to surgical treatment, but data regarding long-term outcomes are scarce. We aim to describe the impact of successful percutaneous mitral PVL closure on long-term outcomes. METHODS: All consecutive patients in whom a first-attempt percutaneous mitral PVL closure was performed in a single tertiary centre between January 2010 and October 2021 were included. Clinical variables, procedural details, and procedural success were collected. Patients were classified based on procedural success, defined as no more than mild residual leak. All-cause mortality was the primary endpoint. Cardiovascular death and heart failure hospitalizations (HFHs) were key secondary endpoints. RESULTS: Ninety patients (median age 72.5 years [66.0-78.4]; median EuroSCORE-II 8.2 [5.3-12.46]) were included. Although reduction of at least 1 degree in PVL severity was achieved in 82 (91.1%), procedural success was achieved in 47 (52.2%). Chronic kidney disease, previous surgery for PVL, and the presence of multiple jets were independently associated with procedural failure. After a median follow-up of 3.2 (1.2-5.2) years, mortality rate was higher in the procedural failure group (27.3 per 100 patients-years) compared with the group with successful closure (8.2 per 100 patient-years). Procedural failure was associated with all-cause death (adjusted hazard ratio [aHR], 2.59; 95% confidence interval [CI], 1.41-4.78), cardiovascular death (aHR, 3.53; 95% CI, 1.67-7.49) and HFH (aHR, 3.27; 95% CI,1.72-6.20). CONCLUSIONS: A successful reduction in PVL to mild or absent is associated with improved rates of all-cause death, cardiovascular death, and HFHs.

4.
Sci Rep ; 13(1): 6907, 2023 04 27.
Artículo en Inglés | MEDLINE | ID: mdl-37106099

RESUMEN

Succinate is enhanced during initial reperfusion in blood from the coronary sinus in ST-segment elevation myocardial infarction (STEMI) patients and in pigs submitted to transient coronary occlusion. Succinate levels might have a prognostic value, as they may correlate with edema volume or myocardial infarct size. However, blood from the coronary sinus is not routinely obtained in the CathLab. As succinate might be also increased in peripheral blood, we aimed to investigate whether peripheral plasma concentrations of succinate and other metabolites obtained during coronary revascularization correlate with edema volume or infarct size in STEMI patients. Plasma samples were obtained from peripheral blood within the first 10 min of revascularization in 102 STEMI patients included in the COMBAT-MI trial (initial TIMI 1) and from 9 additional patients with restituted coronary blood flow (TIMI 2). Metabolite concentrations were analyzed by 1H-NMR. Succinate concentration averaged 0.069 ± 0.0073 mmol/L in patients with TIMI flow ≤ 1 and was significantly increased in those with TIMI 2 at admission (0.141 ± 0.058 mmol/L, p < 0.05). However, regression analysis did not detect any significant correlation between most metabolite concentrations and infarct size, extent of edema or other cardiac magnetic resonance (CMR) variables. In conclusion, spontaneous reperfusion in TIMI 2 patients associates with enhanced succinate levels in peripheral blood, suggesting that succinate release increases overtime following reperfusion. However, early plasma levels of succinate and other metabolites obtained from peripheral blood does not correlate with the degree of irreversible injury or area at risk in STEMI patients, and cannot be considered as predictors of CMR variables.Trial registration: Registered at www.clinicaltrials.gov (NCT02404376) on 31/03/2015. EudraCT number: 2015-001000-58.


Asunto(s)
Insuficiencia Cardíaca , Infarto del Miocardio , Intervención Coronaria Percutánea , Infarto del Miocardio con Elevación del ST , Animales , Imagen por Resonancia Magnética , Infarto del Miocardio/patología , Reperfusión , Ácido Succínico , Porcinos , Resultado del Tratamiento
5.
Fetal Pediatr Pathol ; 42(3): 394-399, 2023 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-36582017

RESUMEN

Purpose: We evaluated the obstetrical outcomes, ultrasonographic characteristics, and final diagnosis in pregnancies with fetal megacystis (FM). Methods: We evaluated the obstetrical outcomes and associated structural abnormalities of fetuses with FM detected between FM between 2000 and 2021. Results: 17 FM were diagnosed, 16 had follow up. 16 were early megacystis. 14/16 (87.5%) of pregnancies were terminated, 1/16 (6.25%) resulted in intrauterine death, and 1/16 (6.25%) survived. FM was associated with 13 other abnormal sonographic findings in 12/16 (75%) pregnancies. The most common associated ultrasound abnormality was umbilical cord cyst in 3/16 (18.75%). Recognized etiologies included posterior urethral valves (2), trisomy 18 (2), trisomy 13 (1), Prune Belly syndrome (1), and Megacystis-Microcolon-Hypoperistalsis syndrome (1). Conclusion: Most FM are detected in the 2nd trimester, most are electively terminated, are associated with other ultrasonic abnormalities in 75%, most commonly umbilical cord cyst, and have an identifiable cause in 44%.


Asunto(s)
Quistes , Enfermedades Fetales , Embarazo , Femenino , Humanos , Ultrasonografía Prenatal/métodos , Enfermedades Fetales/diagnóstico por imagen , Vejiga Urinaria/diagnóstico por imagen
6.
Int J Gynaecol Obstet ; 161(2): 439-446, 2023 May.
Artículo en Inglés | MEDLINE | ID: mdl-36238970

RESUMEN

OBJECTIVE: The authors aimed to compare cross-sectional versus longitudinal models for prediction of small-for-gestational age (SGA) neonates among pregnancies with high risk of early pre-eclampsia (PE). METHODS: A prospective longitudinal study was performed in Hospital Universitari Dexeus, Barcelona. The study population included 390 pregnancies with a high risk of early PE according to the first trimester algorithm. Cross-sectional models combining first trimester risk plus placental growth factor and FMS-like tyrosine kinase 1/placental growth factor ratio, respectively, were created at 19-22, 24-26, and 27-30 weeks and compared with a model assessing longitudinal changes of these parameters. Models adding mean uterine artery pulsatility index and abdominal circumference were evaluated. SGA neonates were defined as having a birth weight less than the tenth centile. RESULTS: The predictive performance of a model assessing longitudinal changes of angiogenic factors was similar to that of single evaluations at the second and early third trimesters. The performance of the models combining angiogenic factors with mean uterine artery pulsatility index and abdominal circumference was better than those using only biochemical markers. However, the longitudinal evaluation of biochemical and biophysical parameters did not perform better than cross-sectional evaluations. CONCLUSIONS: Evaluation of angiogenic factors are useful for prediction of SGA neonates in a high-risk population for early PE. However, longitudinal models do not increase their predictive capacity.


Asunto(s)
Preeclampsia , Proteínas Gestacionales , Embarazo , Recién Nacido , Humanos , Femenino , Factor de Crecimiento Placentario , Estudios Prospectivos , Estudios Longitudinales , Edad Gestacional , Estudios Transversales , Recién Nacido Pequeño para la Edad Gestacional/metabolismo , Retardo del Crecimiento Fetal , Biomarcadores , Ultrasonografía Prenatal , Arteria Uterina/diagnóstico por imagen
7.
Reprod Biomed Online ; 48(6): 103761, 2023 Dec 04.
Artículo en Inglés | MEDLINE | ID: mdl-38603981

RESUMEN

RESEARCH QUESTION: How does first-trimester aneuploidy screening perform in pregnancies achieved through IVF with preimplantation genetic testing for aneuploidy (PGT-A) in a medical setting? DESIGN: This retrospective cohort study was undertaken in a single tertiary care centre between January 2013 and June 2022. In total, 20,237 women had prenatal follow-up at the study centre and were included in the study. The women were divided into three groups: singleton pregnancies conceived through the transfer of a PGT-A-screened euploid embryo (n = 510); singleton pregnancies conceived through IVF without PGT-A (n = 3291); and singleton pregnancies conceived naturally (n = 16,436). RESULTS: The conventional combined screening test for pregnancies conceived through IVF with PGT-A had specificity of 91%; sensitivity could not be calculated as there were no cases of fetal aneuploidy in this group. In 89.1% of pregnancies conceived through IVF with PGT-A with high risk for trisomy 21, 18 or 13, the result was related to advanced maternal age (>35 years at time of screening). CONCLUSIONS: The current screening strategy for trisomies 21, 18 and 13 can generate unnecessary tests in pregnancies achieved through IVF with PGT-A. A new protocol is needed for these patients, with greater weight given to ultrasound markers.

8.
AJOG Glob Rep ; 2(4): 100129, 2022 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-36478665

RESUMEN

BACKGROUND: The rate of twin pregnancies conceived via assisted reproductive technology has increased markedly in recent years. The elevated number of multiple pregnancies is the most serious and frequent complication of assisted reproductive technology. Twin pregnancies are associated with higher rates of obstetrical complications, preterm delivery, and perinatal morbidity and mortality than singleton pregnancies. OBJECTIVE: This study aimed to investigate the association between the mode of conception and obstetrical and perinatal outcomes in twin pregnancies, adjusting for parity, age, and chorionicity. STUDY DESIGN: This was a retrospective cohort study of 1135 twin pregnancies between May 2006 and April 2021. All spontaneous (n=369) and assisted reproductive technology-conceived (n=766) twin pregnancies with antenatal care and delivery in the Universitari Quiron-Dexeus Hospital, Barcelona, Spain, a tertiary obstetrical care center, were studied according to chorionicity. RESULTS: The mean maternal age was higher among assisted reproductive technology twin pregnancies than among naturally conceived ones, and there were also less parous women in the assisted reproductive technology twin group. The global survival rates in both groups of twins were practically identical, namely 744 of 766 (97.1%) assisted reproductive technology twins and 357 of 369 (96.8%) spontaneously conceived twins. Patients with dichorionic assisted reproductive technology twins had a higher incidence of gestational diabetes (relative risk, 1.69; 95% confidence interval, 1.10-2.59) and gestational hypertension or preeclampsia (relative risk, 2.75; 95% confidence interval, 1.60-4.729). Monochorionic diamniotic assisted reproductive technology twins had a higher risk for gestational diabetes (relative risk, 4.12; 95% confidence interval, 1.35-12.56). We analyzed the gestational age at delivery, onset of labor, type of delivery, rate of preterm births, weight discordance, rate of small for gestational age neonates and intrauterine growth restriction, and admission to the neonatal intensive care unit. We could not find any statistical differences between monochorionic diamniotic assisted reproductive technology twins and spontaneously conceived twins. Among dichorionic twins, those conceived by assisted reproductive technology had an earlier gestational age at delivery (36.3±2.29 vs 36.6±2; P<.05) and we found statistical differences in the onset of labor with more cesarean deliveries (relative risk, 1.27; 95% confidence interval, 1.06-1.51). When adjusting for cofounding factors (maternal age, parity, chorionicity), the type of conception remained an independent risk factor for gestational hypertension and preeclampsia but not for gestational diabetes or cesarean delivery. CONCLUSION: Pregnancy outcomes are comparable between assisted reproductive technology and spontaneously conceived twins, and when adjusted for confounding factors, only the risk for gestational hypertension and preeclampsia remained increased in the assisted reproductive technology group.

9.
Int J Cardiol ; 360: 13-20, 2022 08 01.
Artículo en Inglés | MEDLINE | ID: mdl-35472561

RESUMEN

BACKGROUND: incomplete strut coverage determines the risk of stent thrombosis in the first months after stent implantation. AIMS: To evaluate the potential better early healing of a novel probucol coated polymer free ultra-thin strut sirolimus eluting stent (PF-SES). [Clinical trial unique identifier: NCT02785237]. METHODS: Patients with two (angiographically similar) lesions with clinical indication for PCI were enrolled. The investigated stent was compared to a thin strut, bioresorbable polymer, sirolimus eluting stent (BP-SES). Every patient received both stents, one in each lesion, assigned in a randomized sequence. OCT was systematically performed at 3 months. Primary end point was the difference in the proportion of covered struts at 3 months (defined as ≥20 µm of tissue coverage). Secondary end points included differences in percentage of uncovered struts (0 µm coverage), mean strut coverage thickness, and malapposed struts' coverage proportion. Major adverse cardiac events (cardiac death, myocardial infarction, target lesion revascularization, and definite or probable stent thrombosis) at 12 months were also evaluated. RESULTS: 70 patients were included. At 3 months, a consistent and significantly higher strut coverage rate (≥20 µm) was observed in PF-SES as compared to BP-SES, both for well apposed (87.3% versus 79.1%, p < 0.001) and malapposed struts (50.4% vs 37.8%, p 0.00). Uncoverage rate (0 µm) was also significantly lower for the PF-SES (3.1% vs 5.3%, p < 0.001). There were no differences in clinical endpoints. CONCLUSION: The probucol coated non-polymeric ultra-thin strut sirolimus eluting stent showed a significantly better early strut coverage at 3 months.


Asunto(s)
Stents Liberadores de Fármacos , Intervención Coronaria Percutánea , Implantes Absorbibles , Humanos , Intervención Coronaria Percutánea/efectos adversos , Polímeros , Probucol , Diseño de Prótesis , Sirolimus , Stents , Tomografía de Coherencia Óptica , Resultado del Tratamiento
10.
J Perinat Med ; 50(4): 375-385, 2022 05 25.
Artículo en Inglés | MEDLINE | ID: mdl-35285217

RESUMEN

This practice guideline follows the mission of the World Association of Perinatal Medicine in collaboration with the Perinatal Medicine Foundation, bringing together groups and individuals throughout the world, with the goal of improving the use of antenatal corticosteroids (ACS) for fetal maturation. In fact, this document provides further guidance for healthcare practitioners on the appropriate use of ACS with the aim to increase the timely administration and avoid unnecessary or excessive use. Therefore, it is not intended to establish a legal standard of care. This document is based on consensus among perinatal experts throughout the world and serves as a guideline for use in clinical practice.


Asunto(s)
Corticoesteroides , Nacimiento Prematuro , Femenino , Desarrollo Fetal , Humanos , Embarazo , Atención Prenatal
11.
Cardiovasc Revasc Med ; 42: 114-120, 2022 09.
Artículo en Inglés | MEDLINE | ID: mdl-35151602

RESUMEN

BACKGROUND: TiNO-coated BAS have demonstrated competitive outcomes compared to drug-eluting stents (DES). These devices allow short antiplatelet regimens and may be a good option for the growing elderly population undergoing percutaneous coronary intervention (PCI). METHODS: Multicenter observational trial in routine clinical practice. A propensity-score matched analysis compared a prospective cohort of patients ≥ 75 years undergoing PCI with BAS, with a contemporary and retrospective cohort treated with last-generation DES. The co-primary endpoints of the study were the Target-Lesion-Failure (Cardiac death, non-fatal myocardial infarction, or target lesion revascularization) and Major Adverse Cardiovascular Events (total death, non-fatal myocardial infarction, stroke, or new revascularization) at 1 year. RESULTS: Whole population included 1000 patients, and 326 patients in each group were matched for analysis. No differences in primary endpoints were found: TLF 10.4% vs. 11% (HR 0.96 (Confidence Interval 95%, 0.36-1.7; p = 0.87)) and MACE 16.3% vs. 17.2% (HR 0.98 (Confidence Interval 95%; 0.3-1.5, p = 0.93)). Patients treated with BAS received shorter antiplatelets regimens (dual antiplatelet therapy at 1 year, 25.7% vs. 70.6%, p = 0.0001), and they presented lower incidence of bleeding (3.7% vs. 11.7%, HR 0.3 (IC 95% 0.16-0.6, p = 0.001)). CONCLUSION: In this real-life registry of patients ≥ 75 years, BAS were similar to the latest-generation DES in terms of efficacy and reduced the duration of the antithrombotic therapy, lowering bleeding events.


Asunto(s)
Stents Liberadores de Fármacos , Infarto del Miocardio , Intervención Coronaria Percutánea , Anciano , Stents Liberadores de Fármacos/efectos adversos , Humanos , Infarto del Miocardio/etiología , Intervención Coronaria Percutánea/efectos adversos , Estudios Prospectivos , Sistema de Registros , Estudios Retrospectivos , Stents/efectos adversos , Factores de Tiempo , Resultado del Tratamiento
13.
Basic Res Cardiol ; 116(1): 4, 2021 01 25.
Artículo en Inglés | MEDLINE | ID: mdl-33495853

RESUMEN

Remote ischemic conditioning (RIC) and the GLP-1 analog exenatide activate different cardioprotective pathways and may have additive effects on infarct size (IS). Here, we aimed to assess the efficacy of RIC as compared with sham procedure, and of exenatide, as compared with placebo, and the interaction between both, to reduce IS in humans. We designed a two-by-two factorial, randomized controlled, blinded, multicenter, clinical trial. Patients with ST-segment elevation myocardial infarction receiving primary percutaneous coronary intervention (PPCI) within 6 h of symptoms were randomized to RIC or sham procedure and exenatide or matching placebo. The primary outcome was IS measured by late gadolinium enhancement in cardiac magnetic resonance performed 3-7 days after PPCI. The secondary outcomes were myocardial salvage index, transmurality index, left ventricular ejection fraction and relative microvascular obstruction volume. A total of 378 patients were randomly allocated, and after applying exclusion criteria, 222 patients were available for analysis. There were no significant interactions between the two randomization factors on the primary or secondary outcomes. IS was similar between groups for the RIC (24 ± 11.8% in the RIC group vs 23.7 ± 10.9% in the sham group, P = 0.827) and the exenatide hypotheses (25.1 ± 11.5% in the exenatide group vs 22.5 ± 10.9% in the placebo group, P = 0.092). There were no effects with either RIC or exenatide on the secondary outcomes. Unexpected adverse events or side effects of RIC and exenatide were not observed. In conclusion, neither RIC nor exenatide, or its combination, were able to reduce IS in STEMI patients when administered as an adjunct to PPCI.


Asunto(s)
Brazo/irrigación sanguínea , Exenatida/uso terapéutico , Incretinas/uso terapéutico , Precondicionamiento Isquémico , Miocardio/patología , Intervención Coronaria Percutánea , Infarto del Miocardio con Elevación del ST/terapia , Anciano , Terapia Combinada , Método Doble Ciego , Exenatida/efectos adversos , Femenino , Humanos , Incretinas/efectos adversos , Imagen por Resonancia Cinemagnética , Masculino , Persona de Mediana Edad , Intervención Coronaria Percutánea/efectos adversos , Estudios Prospectivos , Flujo Sanguíneo Regional , Infarto del Miocardio con Elevación del ST/diagnóstico por imagen , Infarto del Miocardio con Elevación del ST/patología , Infarto del Miocardio con Elevación del ST/fisiopatología , España , Factores de Tiempo , Resultado del Tratamiento , Función Ventricular Izquierda
15.
Am J Obstet Gynecol ; 224(2): 247, 2021 02.
Artículo en Inglés | MEDLINE | ID: mdl-33127428
16.
BMC Pregnancy Childbirth ; 20(1): 563, 2020 Sep 25.
Artículo en Inglés | MEDLINE | ID: mdl-32988372

RESUMEN

BACKGROUND: Strategies to improve prenatal detection of small-for-gestational age (SGA) neonates are necessary because its association with poorer perinatal outcome. This study evaluated, in pregnancies with first trimester high risk of early preeclampsia, the performance of a third trimester screening for SGA combining biophysical and biochemical markers. METHODS: This is a prospective longitudinal study on 378 singleton pregnancies identified at high risk of early preeclampsia according to a first trimester multiparametric algorithm with the cutoff corresponding to 15% false positive rate. This cohort included 50 cases that delivered SGA neonates with birthweight < 10th centile (13.2%) and 328 cases with normal birthweight (86.8%). At 27-30 weeks' gestation, maternal weight, blood pressure, estimated fetal weight, mean uterine artery pulsatility index and maternal biochemical markers (placental growth factor and soluble FMS-Like Tyrosine Kinase-1) were assessed. Different predictive models were created to evaluate their performance to predict SGA neonates. RESULTS: For a 15% FPR, a model that combines maternal characteristics, estimated fetal weight, mean uterine artery pulsatility index and placental growth factor achieved a detection rate (DR) of 56% with a negative predictive value of 92.2%. The area under receiver operating characteristic curve (AUC) was 0.79 (95% confidence interval (CI), 0.72-0.86). The DR of a model including maternal characteristics, estimated fetal weight and mean uterine artery pulsatility index was 54% (AUC, 0.77 (95% CI, 0.70-0.84)). The DR of a model that includes maternal characteristics and placental growth factor achieved a similar performance (DR 56%, AUC 0.75, 95% CI (0.67-0.83)). CONCLUSIONS: The performance of screening for SGA neonates at early third trimester combining biophysical and biochemical markers in a high-risk population is poor. However, a high negative predictive value could help in reducing maternal anxiety, avoid iatrogenic interventions and propose a specific plan for higher risk patients.


Asunto(s)
Recién Nacido Pequeño para la Edad Gestacional , Preeclampsia/diagnóstico , Embarazo de Alto Riesgo , Diagnóstico Prenatal , Adulto , Biomarcadores/sangre , Femenino , Humanos , Recién Nacido , Estudios Longitudinales , Masculino , Tamizaje Masivo , Preeclampsia/sangre , Embarazo , Tercer Trimestre del Embarazo , Estudios Prospectivos , Medición de Riesgo , Factores de Riesgo
18.
Am J Obstet Gynecol ; 222(6): 608.e1-608.e18, 2020 06.
Artículo en Inglés | MEDLINE | ID: mdl-31972161

RESUMEN

BACKGROUND: Early identification of women with an increased risk for preeclampsia is of utmost importance to minimize adverse perinatal events. Models developed until now (mainly multiparametric algorithms) are thought to be overfitted to the derivation population, which may affect their reliability when applied to other populations. Options allowing adaptation to a variety of populations are needed. OBJECTIVE: The objective of the study was to assess the performance of a first-trimester multivariate Gaussian distribution model including maternal characteristics and biophysical/biochemical parameters for screening of early-onset preeclampsia (delivery <34 weeks of gestation) in a routine care low-risk setting. STUDY DESIGN: Early-onset preeclampsia screening was undertaken in a prospective cohort of singleton pregnancies undergoing routine first-trimester screening (8 weeks 0/7 days to 13 weeks 6/7 days of gestation), mainly using a 2-step scheme, at 2 hospitals from March 2014 to September 2017. A multivariate Gaussian distribution model including maternal characteristics (a priori risk), serum pregnancy-associated plasma protein-A and placental growth factor assessed at 8 weeks 0/7 days to 13 weeks 6/7 days and mean arterial pressure and uterine artery pulsatility index measured at 11.0-13.6 weeks was used. RESULTS: A total of 7908 pregnancies underwent examination, of which 6893 were included in the analysis. Incidence of global preeclampsia was 2.3% (n = 161), while of early-onset preeclampsia was 0.2% (n = 17). The combination of maternal characteristics, biophysical parameters, and placental growth factor showed the best detection rate, which was 59% for a 5% false-positive rate and 94% for a 10% false-positive rate (area under the curve, 0.96, 95% confidence interval, 0.94-0.98). The addition of placental growth factor to biophysical markers significantly improved the detection rate from 59% to 94%. CONCLUSION: The multivariate Gaussian distribution model including maternal factors, early placental growth factor determination (at 8 weeks 0/7 days to 13 weeks 6/7 days), and biophysical variables (mean arterial pressure and uterine artery pulsatility index) at 11 weeks 0/7 days to 13 weeks 6/7 days is a feasible tool for early-onset preeclampsia screening in the routine care setting. Performance of this model should be compared with predicting models based on regression analysis.


Asunto(s)
Presión Arterial , Factor de Crecimiento Placentario/metabolismo , Preeclampsia/epidemiología , Proteína Plasmática A Asociada al Embarazo/metabolismo , Arteria Uterina/diagnóstico por imagen , Adulto , Estudios de Cohortes , Diagnóstico Precoz , Femenino , Humanos , Incidencia , Análisis Multivariante , Distribución Normal , Preeclampsia/diagnóstico , Preeclampsia/metabolismo , Embarazo , Primer Trimestre del Embarazo , Diagnóstico Prenatal , Estudios Prospectivos , Flujo Pulsátil , Medición de Riesgo
19.
Transfus Apher Sci ; 56(2): 165-167, 2017 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-27839964

RESUMEN

The most frequently involved antigen in severe fetal and neonatal alloimmune thrombocytopenia (FNAIT) is the human platelet antigen 1a. Platelets express the HLA-A and B antigens on their membrane and some studies report that maternal anti-HLA class I antibody can also cause FNAIT. We report here a very unusual case of a first twin pregnancy produced in vitro by oocyte and semen donation where the mother developed markedly elevated HLA antibodies, in the absence of anti-platelet or anti-neutrophil antibodies, that provoked in one of the twins a profound thrombocytopenia and intracranial hemorrhage and a mild thrombocytopenia and neutropenia in the second twin lasting until the fourth month of life. In addition, anti-D alloimmunization provoked hemolytic disease of the newborn with intrauterus anemia detected in the first twin and post-natal anemia in the second twin that required red blood cell transfusion and phototherapy. We hypothesize that the complete HLA-incompatible twin pregnancy due to the oocyte donation might have contributed to the severity of the clinical manifestations.


Asunto(s)
Antígenos HLA/inmunología , Embarazo Gemelar , Trombocitopenia Neonatal Aloinmune/inmunología , Resultado Fatal , Femenino , Fertilización In Vitro , Humanos , Persona de Mediana Edad , Embarazo , Trombocitopenia Neonatal Aloinmune/patología , Trombocitopenia Neonatal Aloinmune/fisiopatología
20.
Prog. obstet. ginecol. (Ed. impr.) ; 58(6): 257-263, jun.-jul. 2015. tab, graf
Artículo en Español | IBECS | ID: ibc-139291

RESUMEN

Estudio observacional que valoró la seguridad de heparina de bajo peso molecular (HBPM) administrada para la profilaxis o el tratamiento de complicaciones tromboembólicas durante el embarazo. Diseño: Se revisaron retrospectivamente historias clínicas y se recogió el resultado del embarazo y los acontecimientos adversos. El riesgo tromboembólico (ETEV) se analizó mediante la clasificación del Royal College of Obstetrics and Gynaecologist. Resultados: Se incluyeron 127 pacientes (131 fetos) con edad media de 32,3 ± 4,3 años. La HBPM se indicó por ETEV aguda en 11 (8,6%) pacientes y por profilaxis en 116 (91,4%). En el grupo de profilaxis hubo 38 (30,0%), 49 (38,6%) y 29 (22,8%) pacientes con riesgo de ETEV alto, moderado y bajo respectivamente. Los nacidos vivos fueron 127 (97%) —19 (15,1%) pretérmino—. Una paciente con déficit de antitrombina desarrolló ETEV. Hubo 25 casos de sangrado (18 [72%] hematomas subcutáneos). Conclusión: La HBPM es bien tolerada y segura para la profilaxis y el tratamiento de las complicaciones tromboembólicas del embarazo (AU)


This observational study evaluated the safety of low molecular weight heparin (LMWH) for the prophylaxis and treatment of thromboembolic complications in pregnancy. Study Design: The medical records of pregnant women were identified and reviewed retrospectively. Information was extracted on LMWH use, pregnancy outcome, and adverse events. The Guidelines of the Royal College of Obstetrics and Gynaecologists were used to evaluate the thromboembolic risk. Results: Data were collected on 127 pregnancies (131 fetuses); the mean age was 32.3 ± 4.3. LMWH was prescribed for acute venous thromboembolism in 11 patients (8.6%) and for prophylaxis in 116 (91.4%). For the prophylaxis group, there were 38 (30.0%), 49 (38.6%) and 29 (22.8%) patients with high, moderate and low venous thromboembolism risk, respectively. There were 127 (97%) live births (19 preterm [15.1%]). In the prophylaxis group, one venous thromboembolism occurred in a patient with antithrombin deficiency. Safety outcomes included 25 cases of bleeding (18 [72%] were injection site hematomas). Conclusion: We found that LMWH was well tolerated and safe for the prophylaxis and treatment of thromboembolic complications during pregnancy (AU)


Asunto(s)
Adulto , Femenino , Humanos , Embarazo , Heparina de Bajo-Peso-Molecular/uso terapéutico , Complicaciones Hematológicas del Embarazo/tratamiento farmacológico , Tromboembolia/tratamiento farmacológico , Tromboembolia/prevención & control , Premedicación/métodos , Estudio Observacional
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...