Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Int J Cardiovasc Imaging ; 36(10): 1811-1819, 2020 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-32524242

RESUMEN

We aimed to evaluate the additional debulking efficacy of low-speed rotational atherectomy (RA) after high-speed RA by using intravascular imaging. A total of 22 severe calcified coronary lesions in 19 patients (age, 74 ± 10 years; 74% male) were retrospectively analyzed. All of these lesions underwent RA under optical coherence tomography (OCT) or optical frequency domain imaging (OFDI) guidance. At first, we performed high-speed RA with 220,000 rpm until the reduction of rotational speed disappeared; then, low-speed RA with 120,000 rpm using the same burr size was performed. OCT or OFDI was performed after both high-speed and low-speed RAs, and the minimum lumen area were compared. The initial and final burr sizes of high-speed RA were 1.5 (1.5-1.75) and 1.75 (1.5-2.0) mm, respectively. The number of sessions, total duration time, and maximum decreased rotational speed during high-speed RA were 11 ± 5 times, 113 ± 47 s, and 4000 (3000-5000) rpm, respectively. During low-speed RA, the number of sessions, total duration time, and maximum reduction of rotational speed were 3 ± 1 times, 32 ± 11 s, and 1000 (0-2000) rpm, respectively. The minimum lumen area was similar between after high-speed and after low-speed RA [2.61 ± 1.03 mm2 (after high-speed RA) vs. 2.65 ± 1.00 mm2 (after low-speed RA); P = 0.91]. Additional low-speed RA immediately after sufficient debulking by high-speed RA was not associated with increased lumen enlargement. There was no clinical efficacy of low-speed RA after high-speed RA.


Asunto(s)
Angioplastia Coronaria con Balón , Aterectomía Coronaria , Enfermedad de la Arteria Coronaria/terapia , Calcificación Vascular/terapia , Anciano , Anciano de 80 o más Años , Angioplastia Coronaria con Balón/efectos adversos , Aterectomía Coronaria/efectos adversos , Angiografía Coronaria , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Factores de Tiempo , Tomografía de Coherencia Óptica , Resultado del Tratamiento , Calcificación Vascular/diagnóstico por imagen
2.
SAGE Open Med Case Rep ; 8: 2050313X20921081, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-32577280

RESUMEN

A 68-year-old man was scheduled to undergo percutaneous coronary intervention for in-stent total occlusion of the severely tortuous right coronary artery. Intravascular ultrasound revealed heavy in-stent calcification. Lesion atherectomy was required; however, severe proximal vessel tortuosity was detected. We introduced a 7-Fr guide-extension catheter beyond the severely tortuous part and performed rotational atherectomy with a 1.5 mm burr. However, the balloon could not expand; therefore, we changed to an orbital atherectomy system. Subsequently, the balloon successfully expanded, and intravascular ultrasound revealed an enlarged lumen. Severe proximal vessel tortuosity limits the use of atherectomy devices; however, a guide-extension catheter delivers the atherectomy device beyond the tortuosity. The delivery of the orbital atherectomy system inside the guide-extension catheter is easy due to its low profile; the debulking effect increases with the number of passes and rotational speed. This strategy is a useful option for treating severe calcified lesions with proximal vessel tortuosity.

3.
SAGE Open Med Case Rep ; 8: 2050313X20907825, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-32110413

RESUMEN

A 63 year-old woman with claudication underwent endovascular therapy for diffuse stenosis of the right superficial femoral artery in our hospital. We performed paclitaxel-coated balloon angioplasty using the IN.PACT™ Admiral™ and achieved acceptable results. After 42 days, we performed follow-up optical frequency domain imaging for the right superficial femoral artery lesion treated with paclitaxel-coated balloon and observed several high-intensity regions with attenuation on the lumen surface. Sustained drug availability is a notable characteristic of paclitaxel-coated balloon. To the best of our knowledge, this is the first report on the visualization of sustained drug retention on the lumen surface using follow-up optical frequency domain imaging after paclitaxel-coated balloon angioplasty in a human patient with superficial femoral artery disease.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...