Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros










Intervalo de año de publicación
1.
Rev Esp Enferm Dig ; 113(5): 332-338, 2021 05.
Artículo en Inglés | MEDLINE | ID: mdl-33733801

RESUMEN

BACKGROUND: the impact of the COVID-19 pandemic has led to the interruption of most manometry or impedance-pH monitoring studies. The risk of restarting activities is unknown. OBJECTIVE: assess the risk of SARS-CoV-2 virus infection, both to patients and healthcare workers, in relation to esophageal and anorectal functional tests during the pandemic without protective measures. METHOD: a questionnaire was designed to determine whether patients and healthcare workers had COVID-19, confirmed by either a test or compatible symptoms, after functional studies were performed from January until March 2020. RESULTS: the survey was answered by 263 (92.9 %) patients. Four (1.52 %) patients had confirmed COVID-19 in the two weeks after the functional test (adjusted rate 8.34 cases per 1,000 [95 % CI -0.06-16.74], OR 0.84 [95 % CI: 0.83-0.85], p < 0.001) and no patient after anorectal manometry. Another five had only compatible symptoms, for a total of nine patients (3.42 %) (adjusted rate 27.50 cases/1,000 [95 % CI: 7.27-47.74], OR 2.84 [95 % CI: 2.81-2.87]). In the total study period, 18.25 % had confirmed COVID-19 or compatible symptoms. The average number of days between the procedure and the first day of symptoms was progressively shortened (January: 56 days, February: 33 days, March: 10.5 days). Two of ten healthcare workers (20 %) had confirmed COVID-19. CONCLUSIONS: the risk of COVID-19 infection when performing functional tests is low and more related to the evolution of the pandemic rather than to the procedure itself. The small number of healthcare workers included in the study does not allow a definitive conclusion to be drawn on their risk of infection.


Asunto(s)
COVID-19 , Pandemias , Impedancia Eléctrica , Humanos , Concentración de Iones de Hidrógeno , Manometría , SARS-CoV-2
2.
Rev. esp. enferm. dig ; 109(2): 91-105, feb. 2017. tab, ilus
Artículo en Español | IBECS | ID: ibc-159852

RESUMEN

La manometría esofágica de alta resolución (MAR) está en fase de desarrollo, como se evidencia por las diferentes clasificaciones de Chicago. Con el fin de unificar criterios en algunos aspectos prácticos con limitada evidencia científica se llevó a cabo la Primera Reunión Nacional de Consenso en Manometría de Alta Resolución del Grupo Español de Motilidad Digestiva, en la que participaron un amplio grupo de expertos. Las propuestas se basaron en una encuesta previa con 47 preguntas, la exhaustiva revisión de la bibliografía disponible y la experiencia de los participantes. Se plantearon aspectos metodológicos sobre criterios de análisis poco definidos de algunos nuevos parámetros de alta resolución y otros aspectos no considerados, como la actividad espontánea o las ondas secundarias, elaborándose conclusiones finales con utilidad práctica (AU)


High resolution esophageal manometry (HRM) is currently under development as can be seen in the various Chicago classifications. In order to standardize criteria in certain practical aspects with limited scientific evidence, the First National Meeting for Consensus in High Resolution Manometry of the Spanish Digestive Motility Group took place, bringing together a wide group of experts. The proposals were based on a prior survey composed of 47 questions, an exhaustive review of the available literature and the experience of the participants. Methodological aspects relating to the poorly defined analysis criteria of certain new high resolution parameters were discussed, as well as other issues previously overlooked such as spontaneous activity or secondary waves. Final conclusions were drawn with practical application (AU)


Asunto(s)
Humanos , Masculino , Femenino , Manometría/instrumentación , Manometría/métodos , Manometría , Conferencias de Consenso como Asunto , Sociedades Médicas/organización & administración , Sociedades Médicas/normas , Anestesia/tendencias , Anestesia , Administración Tópica , Motilidad Gastrointestinal , Motilidad Gastrointestinal/fisiología , Trastornos de la Motilidad Esofágica/inducido químicamente , Trastornos de la Motilidad Esofágica/complicaciones , Contracción Muscular , Perfusión/métodos
3.
Rev Esp Enferm Dig ; 109(2): 91-105, 2017 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-27990836

RESUMEN

High resolution esophageal manometry (HRM) is currently under development as can be seen in the various Chicago classifications. In order to standardize criteria in certain practical aspects with limited scientific evidence, the First National Meeting for Consensus in High Resolution Manometry of the Spanish Digestive Motility Group took place, bringing together a wide group of experts. The proposals were based on a prior survey composed of 47 questions, an exhaustive review of the available literature and the experience of the participants. Methodological aspects relating to the poorly defined analysis criteria of certain new high resolution parameters were discussed, as well as other issues previously overlooked such as spontaneous activity or secondary waves. Final conclusions were drawn with practical applications.


Asunto(s)
Enfermedades del Esófago/diagnóstico por imagen , Esófago/diagnóstico por imagen , Manometría/métodos , Anestesia , Consenso , Motilidad Gastrointestinal , Humanos
4.
Dig Dis Sci ; 47(1): 15-9, 2002 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-11837716

RESUMEN

Achalasia, a motor disorder of the esophagus, is accompanied by autoimmune phenomena that could be playing a role in the pathogenesis of the disease. Our objective was to establish the genotypic frequency of the HLA-DR and DQ alleles in patients with achalasia and to establish their relationship with the presence of myenteric antiplexus antibodies in our geographic area. A total of 92 patients diagnosed with achalasia and two control groups with 275 healthy subjects were studied for HLA typing and 40 for autoantibodies determination. The myenteric antiplexus antibodies were positive in 50 patients (54.3%) and in 3 healthy subjects (7.5%) (P < 0.001). The patients showed a significantly higher frequency of DQA1*0103 and DQB1*0603 than was found in the controls. The heterodimer DQA1*0103-DQB1*0603 was increased in the patients [odds ratio (OR) = 2.57]. In regard to the association between the HLA DQA1 and DQB1 alleles and the antiplexus antibodies, these antibodies were found in greater prevalence in those patients with the DQA1*0103 and DQB1*0603 alleles, and the differences were statistically significant (OR = 3.17 and OR = 5.82, respectively). All of the women and 66.7% of the men with achalasia and the DQB1*0603 allele or the DQA1*0103-DQB1*0603 heterodimer were positive for antibodies.


Asunto(s)
Autoanticuerpos/inmunología , Acalasia del Esófago/genética , Acalasia del Esófago/inmunología , Antígenos HLA-D/análisis , Plexo Mientérico/inmunología , Adulto , Anciano , Anciano de 80 o más Años , Alelos , Femenino , Antígenos HLA-DQ/análisis , Antígenos HLA-DR/análisis , Humanos , Masculino , Persona de Mediana Edad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...