Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
1.
J Am Coll Cardiol ; 69(10): 1215-1230, 2017 Mar 14.
Artículo en Inglés | MEDLINE | ID: mdl-27956264

RESUMEN

BACKGROUND: The Society of Thoracic Surgeons (STS)/American College of Cardiology Transcatheter Valve Therapy (TVT) Registry captures all procedures with Food and Drug Administration-approved transcatheter valve devices performed in the United States, and is mandated as a condition of reimbursement by the Centers for Medicaid & Medicare Services. OBJECTIVES: This annual report focuses on patient characteristics, trends, and outcomes of transcatheter aortic and mitral valve catheter-based valve procedures in the United States. METHODS: We reviewed data for all patients receiving commercially approved devices from 2012 through December 31, 2015, that are entered in the TVT Registry. RESULTS: The 54,782 patients with transcatheter aortic valve replacement demonstrated decreases in expected risk of 30-day operative mortality (STS Predicted Risk of Mortality [PROM]) of 7% to 6% and transcatheter aortic valve replacement PROM (TVT PROM) of 4% to 3% (both p < 0.0001) from 2012 to 2015. Observed in-hospital mortality decreased from 5.7% to 2.9%, and 1-year mortality decreased from 25.8% to 21.6%. However, 30-day post-procedure pacemaker insertion increased from 8.8% in 2013 to 12.0% in 2015. The 2,556 patients who underwent transcatheter mitral leaflet clip in 2015 were similar to patients from 2013 to 2014, with hospital mortality of 2% and with mitral regurgitation reduced to grade ≤2 in 87% of patients (p < 0.0001). The 349 patients who underwent mitral valve-in-valve and mitral valve-in-ring procedures were high risk, with an STS PROM for mitral valve replacement of 11%. The observed hospital mortality was 7.2%, and 30-day post-procedure mortality was 8.5%. CONCLUSIONS: The TVT Registry is an innovative registry that that monitors quality, patient safety and trends for these rapidly evolving new technologies.


Asunto(s)
Cateterismo Cardíaco , Cardiología , Enfermedades de las Válvulas Cardíacas/cirugía , Implantación de Prótesis de Válvulas Cardíacas/estadística & datos numéricos , Sistema de Registros , Sociedades Médicas , Cirugía Torácica , Congresos como Asunto , Implantación de Prótesis de Válvulas Cardíacas/métodos , Humanos , Estados Unidos
2.
Ann Thorac Surg ; 103(3): 1021-1035, 2017 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-27955994

RESUMEN

BACKGROUND: The Society of Thoracic Surgeons (STS)/American College of Cardiology Transcatheter Valve Therapy (TVT) Registry captures all procedures with Food and Drug Administration-approved transcatheter valve devices performed in the United States, and is mandated as a condition of reimbursement by the Centers for Medicaid & Medicare Services. OBJECTIVES: This annual report focuses on patient characteristics, trends, and outcomes of transcatheter aortic and mitral valve catheter-based valve procedures in the United States. METHODS: We reviewed data for all patients receiving commercially approved devices from 2012 through December 31, 2015, that are entered in the TVT Registry. RESULTS: The 54,782 patients with transcatheter aortic valve replacement demonstrated decreases in expected risk of 30-day operative mortality (STS Predicted Risk of Mortality [PROM]) of 7% to 6% and transcatheter aortic valve replacement PROM (TVT PROM) of 4% to 3% (both p < 0.0001) from 2012 to 2015. Observed in-hospital mortality decreased from 5.7% to 2.9%, and 1-year mortality decreased from 25.8% to 21.6%. However, 30-day post-procedure pacemaker insertion increased from 8.8% in 2013 to 12.0% in 2015. The 2,556 patients who underwent transcatheter mitral leaflet clip in 2015 were similar to patients from 2013 to 2014, with hospital mortality of 2% and with mitral regurgitation reduced to grade ≤2 in 87% of patients (p < 0.0001). The 349 patients who underwent mitral valve-in-valve and mitral valve-in-ring procedures were high risk, with an STS PROM for mitral valve replacement of 11%. The observed hospital mortality was 7.2%, and 30-day post-procedure mortality was 8.5%. CONCLUSIONS: The TVT Registry is an innovative registry that that monitors quality, patient safety and trends for these rapidly evolving new technologies.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Mitral/cirugía , Sistema de Registros , Reemplazo de la Válvula Aórtica Transcatéter/estadística & datos numéricos , Anciano , Anciano de 80 o más Años , Estenosis de la Válvula Aórtica/diagnóstico , Estenosis de la Válvula Aórtica/mortalidad , Femenino , Mortalidad Hospitalaria , Humanos , Masculino , Persona de Mediana Edad , Estenosis de la Válvula Mitral/diagnóstico , Estenosis de la Válvula Mitral/mortalidad , Estudios Retrospectivos , Sociedades Médicas , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad , Resultado del Tratamiento , Estados Unidos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...