Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Faraday Discuss ; 2024 Jul 26.
Artículo en Inglés | MEDLINE | ID: mdl-39058290

RESUMEN

Using a combination of liquid-phase X-ray spectroscopy experiments and small-scale calculations we have gained new insights into the speciation of halozincate anions in ionic liquids (ILs). Both core and valence X-ray photoelectron spectroscopy (XPS) experiments were performed directly on the liquid-phase ILs, supplemented by Zn 1s X-ray absorption near edge structure (XANES) spectroscopy. Density functional theory (DFT) calculations were carried out on both 1- and 2- halozincate anions, in both a generalised solvation model SMD (Solvation Model based on Density) and the gas phase, to give XP spectra and total energy differences; time-dependent DFT was used to calculate XANES spectra. Speciation judgements were made using a combination of the shape and width of the experimental spectra, and visual matches to the calculated spectra. For 2- halozincate anions, excellent matches were found between the experimental and calculated XP spectra, clearly showing that only 2- halozincate anions were present at all zinc halide mole fractions, x, studied. At specific values of x (0.33, 0.50, 0.60) only one halozincate anion was present; equilibria of different halozincate anions at those values of x were not observed. All findings show that chlorozincate anion and bromozincate anion speciation matched at the same x. Based on the results, predictions are made of the halozincate anion speciation for all values of x up to 0.67. Caution is advised when using differences in calculated total energies obtained from DFT to judge halozincate anion speciation, even when the SMD was employed, as predictions based on total energy differences did not always match the findings from the experimental and calculated spectra. Our findings clearly establish that the combination of high-quality experimental data from multiple spectroscopies and a wide range of calculated structures are essential to have high confidence in halozincate anion speciation identification.

2.
Faraday Discuss ; 236(0): 389-411, 2022 Aug 25.
Artículo en Inglés | MEDLINE | ID: mdl-35543123

RESUMEN

Valence electronic structure is crucial for understanding and predicting reactivity. Valence non-resonant X-ray photoelectron spectroscopy (NRXPS) provides a direct method for probing the overall valence electronic structure. However, it is often difficult to separate the varying contributions to NRXPS; for example, contributions of solutes in solvents or functional groups in complex molecules. In this work we show that valence resonant X-ray photoelectron spectroscopy (RXPS) is a vital tool for obtaining atomic contributions to valence states. We combine RXPS with NRXPS and density functional theory calculations to demonstrate the validity of using RXPS to identify atomic contributions for a range of solutes (both neutral and ionic) and solvents (both molecular solvents and ionic liquids). Furthermore, the one-electron picture of RXPS holds for all of the closed shell molecules/ions studied, although the situation for an open-shell metal complex is more complicated. The factors needed to obtain a strong RXPS signal are investigated in order to predict the types of systems RXPS will work best for; a balance of element electronegativity and bonding type is found to be important. Additionally, the dependence of RXPS spectra on both varying solvation environment and varying local-covalent bonding is probed. We find that RXPS is a promising fingerprint method for identifying species in solution, due to the spectral shape having a strong dependence on local-covalency but a weak dependence on the solvation environment.

3.
Eur Respir J ; 36(1): 81-8, 2010 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-19897554

RESUMEN

Quadriceps strength relates to exercise capacity and prognosis in chronic obstructive pulmonary disease (COPD). We wanted to quantify the prevalence of quadriceps weakness in COPD and hypothesised that it would not be restricted to patients with severe airflow obstruction or dyspnoea. Predicted quadriceps strength was calculated using a regression equation (incorporating age, sex, height and fat-free mass), based on measurements from 212 healthy subjects. The prevalence of weakness (defined as observed values 1.645 standardised residuals below predicted) was related to Global Initiative for Chronic Obstructive Lung Disease (GOLD) stage and Medical Research Council (MRC) dyspnoea score in two cohorts of stable COPD outpatients recruited from the UK (n = 240) and the Netherlands (n = 351). 32% and 33% of UK and Dutch COPD patients had quadriceps weakness. A significant proportion of patients in GOLD stages 1 and 2, or with an MRC dyspnoea score of 1 or 2, had quadriceps weakness (28 and 26%, respectively). These values rose to 38% in GOLD stage 4, and 43% in patients with an MRC Score of 4 or 5. Quadriceps weakness was demonstrable in one-third of COPD patients attending hospital respiratory outpatient services. Quadriceps weakness exists in the absence of severe airflow obstruction or breathlessness.


Asunto(s)
Disnea/fisiopatología , Debilidad Muscular/epidemiología , Enfermedad Pulmonar Obstructiva Crónica/complicaciones , Músculo Cuádriceps/fisiopatología , Índice de Severidad de la Enfermedad , Anciano , Anciano de 80 o más Años , Estudios de Cohortes , Tolerancia al Ejercicio/fisiología , Femenino , Volumen Espiratorio Forzado/fisiología , Humanos , Masculino , Persona de Mediana Edad , Debilidad Muscular/etiología , Países Bajos , Prevalencia , Enfermedad Pulmonar Obstructiva Crónica/fisiopatología , Estudios Retrospectivos , Reino Unido
4.
Thorax ; 64(5): 418-23, 2009 May.
Artículo en Inglés | MEDLINE | ID: mdl-19158125

RESUMEN

BACKGROUND: Quadriceps weakness and loss of muscle mass predict mortality in chronic obstructive pulmonary disease (COPD). It was hypothesised that a reduced quadriceps cross-sectional area could be detected by ultrasound in patients with COPD compared with healthy subjects, and that measurements relate to strength and fat-free mass (FFM). METHODS: Rectus femoris muscle cross-sectional area (RF(CSA)) was measured by ultrasound and whole-body FFM estimated using electrical bioimpedance. Quadriceps strength was measured by maximum voluntary contraction and twitch tension (TwQ) following magnetic femoral nerve stimulation. RESULTS: 26 healthy volunteers of mean (SD) age 63 (9) years and 30 patients with COPD of mean (SD) age 67 (9) years and percentage predicted forced expiratory volume in 1 s (FEV(1)) 48.0 (20.8)% with a similar FFM (46.9 (9.3) kg vs 46.1 (7.3) kg, p = 0.193) participated in the study. Mean RF(CSA) was reduced in patients with COPD by 25% of the mean value in healthy subjects(-115 mm(2); 95% CI -177 to -54, p = 0.001) and was related to MRC dyspnoea scale score, independent of FFM or sex. Maximum voluntary contraction strength was linearly related to RF(CSA) in patients with COPD (r = 0.78, p<0.001). TwQ force per unit of RF(CSA) was similar in both healthy individuals and those with COPD (mean (SD) 17 (4) g/mm(2) vs 18 (3) g/mm(2), p = 0.657). Voluntary contraction strength per unit of RF(CSA) was dependent on central quadriceps activation and peripheral oxygen saturation in COPD. CONCLUSION: Ultrasound measurement of RF(CSA) is an effort-independent and radiation-free method of measuring quadriceps muscle cross-sectional area in patients with COPD that relates to strength.


Asunto(s)
Fuerza Muscular/fisiología , Debilidad Muscular/patología , Enfermedad Pulmonar Obstructiva Crónica/patología , Músculo Cuádriceps/patología , Adulto , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Persona de Mediana Edad , Debilidad Muscular/diagnóstico por imagen , Debilidad Muscular/fisiopatología , Enfermedad Pulmonar Obstructiva Crónica/diagnóstico por imagen , Enfermedad Pulmonar Obstructiva Crónica/fisiopatología , Músculo Cuádriceps/diagnóstico por imagen , Músculo Cuádriceps/fisiopatología , Ultrasonografía
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA