Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 39
Filtrar
2.
Heart Rhythm ; 2024 May 05.
Artículo en Inglés | MEDLINE | ID: mdl-38752909

RESUMEN

BACKGROUND: Because of differences in chest wall anatomy, female patients may have higher rates of subcutaneous implantable cardioverter-defibrillator (S-ICD) pocket-related complications. OBJECTIVE: We sought to evaluate sex-based outcomes after S-ICD implantation. METHODS: Patients implanted with an S-ICD at Emory Healthcare between 2010 and 2023 were included in the analysis. Patients' clinical characteristics and post-S-ICD implantation complications were collected. RESULTS: There were 429 male patients (68%) and 199 female patients (32%) observed for a median duration of 2.3 years (0.6-4.4 years). Male and female patients had comparable rates of diabetes (28%), end-stage renal disease (29.5%), ejection fraction (30.2% ± 13.4%), and body mass index (29.1 ± 6.6 kg/m2). There was no statistical difference in the incidence of shocks between men and women (26.3% vs 20.1%; P = .09), including appropriate shocks (14.7% vs 12%; P = .98) and inappropriate shocks (11.7% vs 9.5%; P = .98). Pocket-related complications occurred in 21 patients; these included pocket infection (n = 12), wound dehiscence (n = 7), and hematoma requiring drainage (n = 2). Female patients had a significantly higher pocket-related complication rate compared with male patients (7.2% vs 2.5%; P = .016). In controlling for age, body mass index, diabetes, and end-stage renal disease, female patients had higher odds of pocket-related complications compared with male patients (odds ratio, 3.15; 95% confidence interval, 1.27-7.75). Pocket-related complications decreased after 2018 compared with before 2018 (6% vs 2.6%, P = .052), mainly driven by reduction in complications in women (12.3% vs 3.2%; P = .034) but not in men (2.8% vs 2.4%; P = 1). CONCLUSION: In this cohort of S-ICD patients, women had a higher rate of post-S-ICD pocket-related complications that could be explained by sex-based differences in anatomy.

3.
J Cardiovasc Electrophysiol ; 35(5): 929-938, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38450808

RESUMEN

INTRODUCTION: Transvenous leads have been implicated in tricuspid valve (TV) dysfunction, but limited data are available regarding the effect of extracting leads across the TV on valve regurgitation. The aim of this study is to quantify tricuspid regurgitation (TR) before and after lead extraction and identify predictors of worsening TR. METHODS: We studied 321 patients who had echocardiographic data before and after lead extraction. TR was graded on a scale (0 = none/trivial, 1 = mild, 2 = moderate, 3 = severe). A change of >1 grade following extraction was considered significant. RESULTS: A total of 321 patients underwent extraction of a total of 338 leads across the TV (1.05 ± 0.31 leads across the TV per patient). There was no significant difference on average TR grade pre- and postextraction (1.18 ± 0.91 vs. 1.15 ± 0.87; p = 0.79). TR severity increased after extraction in 84 patients, but was classified as significantly worse (i.e., >1 grade change in severity) in only 8 patients (2.5%). Use of laser lead extraction was associated with a higher rate of worsening TR postextraction (44.0% vs. 31.6%, p = 0.04). CONCLUSION: In our single-center analysis, extraction of leads across the TV did not significantly affect the extent of TR in most patients. Laser lead extraction was associated with a higher rate of worsening TR after extraction.


Asunto(s)
Remoción de Dispositivos , Insuficiencia de la Válvula Tricúspide , Humanos , Insuficiencia de la Válvula Tricúspide/fisiopatología , Insuficiencia de la Válvula Tricúspide/cirugía , Insuficiencia de la Válvula Tricúspide/diagnóstico por imagen , Insuficiencia de la Válvula Tricúspide/etiología , Insuficiencia de la Válvula Tricúspide/diagnóstico , Masculino , Femenino , Remoción de Dispositivos/efectos adversos , Anciano , Resultado del Tratamiento , Persona de Mediana Edad , Estudios Retrospectivos , Factores de Riesgo , Índice de Severidad de la Enfermedad , Válvula Tricúspide/fisiopatología , Válvula Tricúspide/cirugía , Válvula Tricúspide/diagnóstico por imagen , Desfibriladores Implantables , Factores de Tiempo , Marcapaso Artificial , Anciano de 80 o más Años , Dispositivos de Terapia de Resincronización Cardíaca
4.
Europace ; 25(12)2023 12 06.
Artículo en Inglés | MEDLINE | ID: mdl-38000900

RESUMEN

AIMS: Single-connector (DF4) defibrillator leads have become the predominantly implanted transvenous implantable cardioverter-defibrillator lead. However, data on their long-term performance are derived predominantly from manufacturer product performance reports. METHODS AND RESULTS: We reviewed medical records in 5289 patients with DF4 leads between 2011 and 2023 to determine the frequency of lead-related abnormalities. We defined malfunction as any single or combination of electrical abnormalities requiring revision including a sudden increase (≥2×) in stimulation threshold, a discrete jump in high-voltage impedance, or sensing of non-physiologic intervals or noise. We documented time to failure, predictors of failure, and management strategies. Mean follow-up after implant was 4.15 ± 3.6 years (median = 3.63), with 37% of leads followed for >5 years. A total of 80 (1.5%) leads demonstrated electrical abnormalities requiring revision with an average time to failure of 4 ± 2.8 years (median = 3.5). Of the leads that malfunctioned, 62/80 (78%) were extracted and replaced with a new lead and in the other 18 cases, malfunctioned DF4 leads were abandoned, and a new lead implanted. In multivariable models, younger age at implant (OR 1.03 per year; P < 0.001) and the presence of Abbott/St. Jude leads increased the risk of malfunction. CONCLUSION: DF4 defibrillator leads demonstrate excellent longevity with >98.3% of leads followed for at least 5 years still functioning normally. Younger age at implant and lead manufacturer are associated with an increased risk of DF4 lead malfunction. The differences in lead survival between manufacturers require further investigation.


Asunto(s)
Desfibriladores Implantables , Humanos , Desfibriladores Implantables/efectos adversos , Falla de Equipo , Estudios Retrospectivos
5.
Europace ; 25(12)2023 12 06.
Artículo en Inglés | MEDLINE | ID: mdl-38006390

RESUMEN

AIMS: The mechanisms of transition from regular rhythms to ventricular fibrillation (VF) are poorly understood. The concordant to discordant repolarization alternans pathway is extensively studied; however, despite its theoretical centrality, cannot guide ablation. We hypothesize that complex repolarization dynamics, i.e. oscillations in the repolarization phase of action potentials with periods over two of classic alternans, is a marker of electrically unstable substrate, and ablation of these areas has a stabilizing effect and may reduce the risk of VF. To prove the existence of higher-order periodicities in human hearts. METHODS AND RESULTS: We performed optical mapping of explanted human hearts obtained from recipients of heart transplantation at the time of surgery. Signals recorded from the right ventricle endocardial surface were processed to detect global and local repolarization dynamics during rapid pacing. A statistically significant global 1:4 peak was seen in three of six hearts. Local (pixel-wise) analysis revealed the spatially heterogeneous distribution of Periods 4, 6, and 8, with the regional presence of periods greater than two in all the hearts. There was no significant correlation between the underlying restitution properties and the period of each pixel. CONCLUSION: We present evidence of complex higher-order periodicities and the co-existence of such regions with stable non-chaotic areas in ex vivo human hearts. We infer that the oscillation of the calcium cycling machinery is the primary mechanism of higher-order dynamics. These higher-order regions may act as niduses of instability and may provide targets for substrate-based ablation of VF.


Asunto(s)
Ventrículos Cardíacos , Corazón , Humanos , Arritmias Cardíacas , Fibrilación Ventricular/cirugía , Potenciales de Acción/fisiología
6.
J Cardiovasc Electrophysiol ; 34(11): 2225-2232, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-37702135

RESUMEN

INTRODUCTION: The need for pacemaker is a common complication after transcatheter aortic valve replacement (TAVR). We previously described the Emory Risk Score (ERS) to predict the need for new pacemaker implant (PPM) after TAVR. Metrics included in the score are a history of syncope, pre-existing RBBB, QRS duration ≥140 ms, and prosthesis oversizing ≥16%. To prospectively validate the previously described risk score. METHODS: We prospectively evaluated all patients without pre-existing pacemakers, ICD, or pre-existing indications for pacing undergoing TAVR with the Edwards SAPIEN 3 prosthesis at our institution from March 2019 to December 2020 (n = 661). Patients were scored prospectively; however, results were blinded from clinical decision-making. The primary endpoint was PPM at 30 days after TAVR. Performance of the ERS was evaluated using logistic regression, a calibration curve to prior performance, and receiver operating characteristic (ROC) analysis. RESULTS: A total of 48 patients (7.3%) had PPM after TAVR. A higher ERS predicted an increased likelihood of PPM (OR 2.61, 95% CI: 2.05-3.25 per point, p < 0.001). There was good correlation between observed and expected values on the calibration curve (slope = 1.04, calibration at large = 0.001). The area under the ROC curve was 0.81 (95% CI [0.74-0.88], p < 0.001). CONCLUSIONS: The ERS prospectively predicted the need for PPM in a serial, real-world cohort of patients undergoing TAVR with a balloon-expandable prosthesis, confirming findings previously described in retrospective cohorts. Notably, the prospective performance of the score was comparable with that of the initial cohorts. The risk score could serve as a framework for preprocedural risk stratification for PPM after TAVR.


Asunto(s)
Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Marcapaso Artificial , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Estudios Retrospectivos , Estimulación Cardíaca Artificial/efectos adversos , Estimulación Cardíaca Artificial/métodos , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Resultado del Tratamiento , Factores de Riesgo , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía
7.
medRxiv ; 2023 Aug 21.
Artículo en Inglés | MEDLINE | ID: mdl-37662394

RESUMEN

Background: Repolarization alternans, defined as period-2 oscillation in the repolarization phase of the action potentials, provides a mechanistic link between cellular dynamics and ventricular fibrillation (VF). Theoretically, higher-order periodicities (e.g., periods 4, 6, 8,...) are expected but have minimal experimental evidence. Methods: We studied explanted human hearts obtained from recipients of heart transplantation at the time of surgery. Optical mapping of the transmembrane potential was performed after staining the hearts with voltage-sensitive fluorescent dyes. Hearts were stimulated at an increasing rate until VF was induced. Signals recorded from the right ventricle endocardial surface prior to induction of VF and in the presence of 1:1 conduction were processed using the Principal Component Analysis and a combinatorial algorithm to detect and quantify higher-order dynamics. Results were correlated to the underlying electrophysiological characteristics as quantified by restitution curves and conduction velocity. Results: A prominent and statistically significant global 1:4 peak (corresponding to period-4 dynamics) was seen in three of the six studied hearts. Local (pixel-wise) analysis revealed the spatially heterogeneous distribution of periods 4, 6, and 8, with the regional presence of periods greater than two in all the hearts. There was no significant correlation between the underlying restitution properties and the period of each pixel. Discussion: We present evidence of higher-order periodicities and the co-existence of such regions with stable non-chaotic areas in ex-vivo human hearts. We infer from the independence of the period to the underlying restitution properties that the oscillation of the excitation-contraction coupling and calcium cycling mechanisms is the primary mechanism of higher-order dynamics. These higher-order regions may act as niduses of instability that can degenerate into chaotic fibrillation and may provide targets for substrate-based ablation of VF.

8.
Heart Rhythm ; 20(12): 1669-1673, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37591366

RESUMEN

BACKGROUND: Same-day discharge (SDD) after cardiovascular procedures is rapidly gaining ground. OBJECTIVE: We sought to evaluate the safety of SDD after transvenous lead extraction (TLE). METHODS: We performed a retrospective chart review of patients who underwent elective TLE between January 2020 and October 2021 at our institution. The primary outcome was SDD, and major procedural complications and readmissions within 30 days of the procedure were secondary outcomes. RESULTS: In this analysis of 111 patients who underwent elective TLE, 80 patients (72%) were discharged on the same day (SDD group) while 31 patients (28%) stayed overnight (overnight group). Lead malfunction was the most common indication for TLE in both groups. Patients in the overnight group were more likely to have a lead dwell time of ≤10 years than those in the SDD group (38.7% vs 20% of all leads in each group; P = .042), have laser sheaths used for extraction and a higher number of leads extracted. No major complications were reported in both groups. In a multivariate analysis, lower body mass index and the use of laser sheath during TLE were predictors of overnight stay. Patients who underwent a procedure using advanced extraction techniques were 3.5 times more likely to stay overnight (95% confidence interval 1.27-9.78; P = .016). CONCLUSION: In appropriately selected patients undergoing elective lead extraction, SDD is feasible and safe. Higher body mass index, fewer extracted leads, shorter lead dwell times (<10 years), and less frequent use of laser-powered extraction sheaths were associated with an increased likelihood of SDD.


Asunto(s)
Desfibriladores Implantables , Alta del Paciente , Humanos , Estudios Retrospectivos , Resultado del Tratamiento , Remoción de Dispositivos/efectos adversos , Remoción de Dispositivos/métodos , Desfibriladores Implantables/efectos adversos
9.
Ann Noninvasive Electrocardiol ; 28(5): e13073, 2023 09.
Artículo en Inglés | MEDLINE | ID: mdl-37515396

RESUMEN

BACKGROUND: The use of a Left Ventricular Assist Device (LVAD) in patients with advanced heart failure refractory to optimal medical management has progressed steadily over the past two decades. Data have demonstrated reduced LVAD efficacy, worse clinical outcome, and higher mortality for patients who experience significant ventricular tachyarrhythmia (VTA). We hypothesize that a novel prophylactic intra-operative VTA ablation protocol at the time of LVAD implantation may reduce the recurrent VTA and adverse events postimplant. METHODS: We designed a prospective, multicenter, open-label, randomized-controlled clinical trial enrolling 100 patients who are LVAD candidates with a history of VTA in the previous 5 years. Enrolled patients will be randomized in a 1:1 fashion to intra-operative VTA ablation (n = 50) versus conventional medical management (n = 50) with LVAD implant. Arrhythmia outcomes data will be captured by an implantable cardioverter defibrillator (ICD) to monitor VTA events, with a uniform ICD programming protocol. Patients will be followed prospectively over a mean of 18 months (with a minimum of 9 months) after LVAD implantation to evaluate recurrent VTA, adverse events, and procedural outcomes. Secondary endpoints include right heart function/hemodynamics, healthcare utilization, and quality of life. CONCLUSION: The primary aim of this first-ever randomized trial is to assess the efficacy of intra-operative ablation during LVAD surgery in reducing VTA recurrence and improving clinical outcomes for patients with a history of VTA.


Asunto(s)
Desfibriladores Implantables , Insuficiencia Cardíaca , Corazón Auxiliar , Taquicardia Ventricular , Humanos , Corazón Auxiliar/efectos adversos , Estudios Prospectivos , Calidad de Vida , Factores de Riesgo , Electrocardiografía , Arritmias Cardíacas , Taquicardia Ventricular/etiología , Resultado del Tratamiento
12.
bioRxiv ; 2023 May 02.
Artículo en Inglés | MEDLINE | ID: mdl-37205562

RESUMEN

Background: Repolarization alternans, defined as period-2 oscillation in the repolarization phase of the action potentials, is one of the cornerstones of cardiac electrophysiology as it provides a mechanistic link between cellular dynamics and ventricular fibrillation (VF). Theoretically, higher-order periodicities (e.g., period-4, period-8,...) are expected but have very limited experimental evidence. Methods: We studied explanted human hearts, obtained from the recipients of heart transplantation at the time of surgery, using optical mapping technique with transmembrane voltage-sensitive fluorescent dyes. The hearts were stimulated at an increasing rate until VF was induced. The signals recorded from the right ventricle endocardial surface just before the induction of VF and in the presence of 1:1 conduction were processed using the Principal Component Analysis and a combinatorial algorithm to detect and quantify higher-order dynamics. Results: A prominent and statistically significant 1:4 peak (corresponding to period-4 dynamics) was seen in three of the six studied hearts. Local analysis revealed the spatiotemporal distribution of higher-order periods. Period-4 was localized to temporally stable islands. Higher-order oscillations (period-5, 6, and 8) were transient and primarily occurred in arcs parallel to the activation isochrones. Discussion: We present evidence of higher-order periodicities and the co-existence of such regions with stable non-chaotic areas in ex-vivo human hearts before VF induction. This result is consistent with the period-doubling route to chaos as a possible mechanism of VF initiation, which complements the concordant to discordant alternans mechanism. The presence of higher-order regions may act as niduses of instability that can degenerate into chaotic fibrillation.

14.
J Cardiovasc Electrophysiol ; 34(5): 1111-1118, 2023 05.
Artículo en Inglés | MEDLINE | ID: mdl-37036297

RESUMEN

INTRODUCTION: Hemodynamic decompensation during catheter ablation occurs due to prolonged procedure time and irrigant delivery directly into the cardiac chambers. Real-time hemodynamic monitoring of patients undergoing catheter ablation procedures may identify patients at risk of decompensation; we set out to assess the feasibility of a novel, real-time, intracardiac pressure monitoring system using a standard irrigated ablation catheter. METHODS: We studied 13 consecutive who underwent pressure measurement of the left atrium (LA) and left ventricle (LV) via transeptal access with a Swan Ganz (SG) catheter followed by two commercially available irrigated ablation catheters. Pressure waveform data was extracted to compare LA peak pressure, LV peak systolic pressure, LV end-diastolic pressure, and waveform analysis. RESULTS: Comparison between the SG and ablation catheters (AblA; AblB) demonstrated that LV systolic pressure (0.61-16.8 mmHg; 1.32-18.2 mmHg), and LV end-diastolic pressure (-3.4 to 2.8 mmHg; -3.0 to 3.35 mmHg) were well correlated and had accepted repeatability. Ablation waveforms demonstrated an 89.9 ± 6.4% correlation compared to SG waveforms. CONCLUSION: Pressure measurements derived from an irrigated ablation catheter are accurate and reliable when compared to an SG catheter. Further studies are needed to determine how real-time pressure monitoring can improve outcomes during ablation procedures.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Humanos , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Fibrilación Atrial/etiología , Hemodinámica , Atrios Cardíacos/cirugía , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Catéteres , Resultado del Tratamiento
15.
JACC Clin Electrophysiol ; 9(7 Pt 2): 1172-1180, 2023 07.
Artículo en Inglés | MEDLINE | ID: mdl-36898953

RESUMEN

BACKGROUND: Class IC antiarrhythmic agents are effective for treating atrial tachyarrhythmias, but their use is restricted in patients with coronary artery disease (CAD). Data on the safety of the use of IC agents in patients with CAD in the absence of recent acute coronary syndromes are lacking. OBJECTIVES: This study sought to evaluate the safety and feasibility of treatment with IC agents in patients with varying degrees of CAD in a large serial, real-world cohort. METHODS: We retrospectively identified all patients at our institution from January 2005 to February 2021 on a IC agent (n = 3,445) and those on sotalol or dofetilide (n = 2,216) as controls, excluding those with a prior history of ventricular tachycardia, implantable cardioverter-defibrillator placement, or nonrevascularized myocardial infarction. Baseline clinical characteristics included degree of CAD (categorized as none, nonobstructive, or obstructive), other comorbid illness, and medication use. Clinical outcomes, including survival, were ascertained. We performed Cox regression analysis to evaluate the effect of IC use on event-free survival across varying degrees of CAD. RESULTS: After adjustment for baseline characteristics, there was an independent association between IC use and improved mortality. However, there was an interaction between IC use and degree of CAD (compared to sotalol) demonstrating poorer event-free survival among those with obstructive coronary disease (HR: 3.80; 95% CI: 1.67-8.67; P = 0.002). CONCLUSIONS: Among select patients with nonobstructive CAD and without a history of ventricular tachycardia, IC agents are not associated with increased mortality. Therefore, these agents may be an option for some patients in whom they are frequently restricted. Further prospective studies are warranted.


Asunto(s)
Enfermedad de la Arteria Coronaria , Taquicardia Ventricular , Humanos , Enfermedad de la Arteria Coronaria/complicaciones , Enfermedad de la Arteria Coronaria/tratamiento farmacológico , Flecainida/efectos adversos , Sotalol/uso terapéutico , Estudios Retrospectivos , Estudios de Factibilidad , Taquicardia Ventricular/tratamiento farmacológico , Taquicardia Ventricular/complicaciones
18.
J Geriatr Cardiol ; 18(9): 720-727, 2021 Sep 28.
Artículo en Inglés | MEDLINE | ID: mdl-34659378

RESUMEN

BACKGROUND: Little is known about health status and quality of life (QoL) after implantable cardioverter-defibrillator (ICD) generator exchange (GE). METHODS: We prospectively followed patients undergoing first-time ICD GE. Serial assessments of health status were performed by administering the 36-Item Short Form Survey (SF-36). RESULTS: Mean age was 67.5 ± 14.3 years, left ventricle ejection fraction (LVEF) was 36.5% ± 15.0% and over 40% of the cohort had improved LVEF to > 35% at the time of GE. SF-36 scores were significantly worse in physical/general health domains compared to domains of emotional/social well-being ( P < 0.001 for each comparison). Physical health scores were significantly worse among those with medical comorbidities including diabetes, chronic obstructive pulmonary disease and atrial fibrillation. Mean follow-up was 1.6 ± 0.5 years after GE. Overall SF-36 scores remained stable across all domains during follow-up. Survival at 3 years post-GE was estimated at 80%. Five patients died during follow-up and most deaths were adjudicated as non-arrhythmic in origin. Four patients experienced appropriate ICD shocks after GE, three of whom had LVEF which remains impaired LVEF (i.e., < 35%) at the time of GE. CONCLUSION: Patients undergoing ICD GE have significantly worse physical health compared to emotional/social well-being, which is associated with the presence of medical comorbidities. In terms of clinical outcomes, the incidence of appropriate shocks after GE among those with improvement in LVEF is very low, and most deaths post-procedure appear to be non-arrhythmic in origin. These data represent an attempt to more fully characterize the spectrum of QoL and clinical outcomes after GE.

20.
Heart Rhythm ; 18(3): 338-346, 2021 03.
Artículo en Inglés | MEDLINE | ID: mdl-33250442

RESUMEN

BACKGROUND: Wider availability of continuous rhythm monitoring has made feasible the incorporation of metrics of atrial fibrillation (AF) burden and duration into the decision to initiate anticoagulation. However, the relationship between thresholds of burden and duration and underlying risk factors at which anticoagulation should be considered remains unclear. OBJECTIVE: The purpose of this study was to evaluate the relationships of these metrics with each other and the outcome of stroke/transient ischemic attack (TIA). METHODS: We identified patients with cardiovascular implantable electronic devices (CIEDs) with atrial leads who had at least 1 interrogation in 2016 demonstrating nonpermanent AF and were not receiving oral anticoagulation (OAC). We evaluated the relationship between burden (ie, percentage of time spent in AF), the longest single episode of AF, and risk factors (ie, CHA2DS2-VASc score) in predicting risk of stroke/TIA. RESULTS: The study included 384 patients with mean follow-up of 3.2 ± 0.8 years and incidence of stroke/TIA of 14.8% during follow-up (∼4.6% per year). The burden of AF and the duration of longest episode demonstrated a significant positive correlation to each other but not CHA2DS2-VASc score. Importantly, although the CHA2DS2-VASc score was predictive of stroke/TIA, neither burden nor duration was associated with stroke/TIA. CONCLUSION: Among patients with CIED-detected AF not receiving OAC, the amount of AF (measured by either burden or duration) does not seem to significantly impact stroke risk, whereas CHA2DS2-VASc score does. These data suggest that among patients with CIED-detected AF, once AF occurs, stroke risk seems to be predominantly driven by underlying risk factors.


Asunto(s)
Anticoagulantes/uso terapéutico , Fibrilación Atrial/diagnóstico , Electrocardiografía Ambulatoria/instrumentación , Frecuencia Cardíaca/fisiología , Accidente Cerebrovascular Isquémico/etiología , Medición de Riesgo/métodos , Anciano , Fibrilación Atrial/complicaciones , Fibrilación Atrial/tratamiento farmacológico , Diseño de Equipo , Estudios de Factibilidad , Femenino , Estudios de Seguimiento , Humanos , Incidencia , Accidente Cerebrovascular Isquémico/epidemiología , Accidente Cerebrovascular Isquémico/prevención & control , Masculino , Estudios Retrospectivos , Estados Unidos/epidemiología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...