Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 20
Filtrar
1.
Z Med Phys ; 2024 Mar 19.
Artículo en Inglés | MEDLINE | ID: mdl-38508947

RESUMEN

Time-harmonic elastography (THE) is an emerging ultrasound imaging technique that allows full-field mapping of the stiffness of deep biological tissues. THE's unique ability to rapidly capture stiffness in multiple tissues has never been applied for imaging skeletal muscle. Therefore, we addressed the lack of data on temporal changes in skeletal muscle stiffness while simultaneously covering stiffness of different muscles. Acquiring repeated THE scans every five seconds we quantified shear-wave speed (SWS) as a marker of stiffness of the long head (LHB) and short head (SHB) of biceps brachii and of the brachialis muscle (B) in ten healthy volunteers. SWS was continuously acquired during a 3-min isometric preloading phase, a 3-min loading phase with different weights (4, 8, and 12 kg), and a 9-min postloading phase. In addition, we analyzed temporal SWS standard deviation (SD) as a marker of muscle contraction regulation. Our results (median [min, max]) showed both SWS at preloading (LHB: 1.04 [0.94, 1.12] m/s, SHB: 0.86 [0.78, 0.94] m/s, B: 0.96 [0.87, 1.09] m/s, p < 0.001) and the increase in SWS with loading weight to be muscle-specific (LHB: 0.010 [0.002, 0.019] m/s/kg, SHB: 0.022 [0.017, 0.042] m/s/kg, B: 0.039 [0.019, 0.062] m/s/kg, p < 0.001). Additionally, SWS during loading increased continuously over time by 0.022 [0.004, 0.051] m/s/min (p < 0.01). Using an exponential decay model, we found an average relaxation time of 27 seconds during postloading. Analogously, SWS SD at preloading was also muscle-specific (LHB: 0.018 [0.011, 0.029] m/s, SHB: 0.021 [0.015, 0.027] m/s, B: 0.024 [0.018, 0.037] m/s, p < 0.05) and increased by 0.005 [0.003, 0.008] m/s/kg (p < 0.01) with loading. SWS SD did not change over loading time and decreased immediately in the postloading phase. Taken together, THE of skeletal muscle is a promising imaging technique for in vivo quantification of stiffness and stiffness changes in multiple muscle groups within seconds. Both the magnitude of stiffness changes and their temporal variation during isometric exercise may reflect the functional status of skeletal muscle and provide additional information to the morphological measures obtained by conventional imaging modalities.

3.
Quant Imaging Med Surg ; 13(8): 4792-4805, 2023 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-37581033

RESUMEN

Background: Although there is growing evidence that functional involvement and structural changes of mesenteric adipose tissue (MAT) influence the course of Crohn's disease (CD), its viscoelastic properties remain elusive. Therefore, we aimed to investigate the viscoelastic properties of MAT in CD using magnetic resonance elastography (MRE), providing reference values for CD diagnosis. Methods: In this prospective proof-of-concept study, 31 subjects (CD: n=11; healthy controls: n=20) were consecutively enrolled in a specialized care center for inflammatory bowel diseases (tertiary/quaternary care). Inclusion criteria for the CD patients were a clinically and endoscopically established diagnosis of CD based on the clinical record, absence of other concurrent bowel diseases, scheduled surgery for the following day, and age of at least 18 years. Diagnoses were confirmed by histological analysis of the resected bowel the day after MRE. Subjects were investigated using MRE at 1.5-T with frequencies of 40-70 Hz. To retrieve shear wave speed (SWS), volumes of interest (VOIs) in MAT were drawn adjacent to CD lesions (MATCD) and on the opposite side without adjacent bowel lesions in patients (MATCD_Opp) and controls (MATCTRL). The presented study is not registered in the clinical trial platform. Results: A statistically significant decrease in mean SWS of 7% was found for MATCD_Opp vs. MATCTRL (0.76±0.05 vs. 0.82±0.04 m/s, P=0.012), whereas there was a nonsignificant trend with an 8% increase for MATCD vs. MATCD_Opp (0.82±0.07 vs. 0.76±0.05 m/s, P=0.098) and no difference for MATCD vs. MATCTRL. Preliminary area under the receiver operating characteristic curve (AUC) analysis showed diagnostic accuracy in detecting CD to be excellent for SWS of MATCD_Opp [AUC =0.82; 95% confidence interval (CI): 0.64-0.96] but poor for SWS of MATCD (AUC =0.52; 95% CI: 0.34-0.73). Conclusions: This study demonstrates the feasibility of MRE of MAT and presents preliminary reference values for CD patients and healthy controls. Our results motivate further studies for the biophysical characterization of MAT in inflammatory bowel disease.

4.
Adv Sci (Weinh) ; 10(26): e2303523, 2023 09.
Artículo en Inglés | MEDLINE | ID: mdl-37553780

RESUMEN

Cancer progression is caused by genetic changes and associated with various alterations in cell properties, which also affect a tumor's mechanical state. While an increased stiffness has been well known for long for solid tumors, it has limited prognostic power. It is hypothesized that cancer progression is accompanied by tissue fluidization, where portions of the tissue can change position across different length scales. Supported by tabletop magnetic resonance elastography (MRE) on stroma mimicking collagen gels and microscopic analysis of live cells inside patient derived tumor explants, an overview is provided of how cancer associated mechanisms, including cellular unjamming, proliferation, microenvironment composition, and remodeling can alter a tissue's fluidity and stiffness. In vivo, state-of-the-art multifrequency MRE can distinguish tumors from their surrounding host tissue by their rheological fingerprints. Most importantly, a meta-analysis on the currently available clinical studies is conducted and universal trends are identified. The results and conclusions are condensed into a gedankenexperiment about how a tumor can grow and eventually metastasize into its environment from a physics perspective to deduce corresponding mechanical properties. Based on stiffness, fluidity, spatial heterogeneity, and texture of the tumor front a roadmap for a prognosis of a tumor's aggressiveness and metastatic potential is presented.


Asunto(s)
Neoplasias , Humanos , Colágeno , Pronóstico , Microambiente Tumoral
5.
J Mech Behav Biomed Mater ; 138: 105613, 2023 02.
Artículo en Inglés | MEDLINE | ID: mdl-36549250

RESUMEN

Mechanical properties of brain tissue are very complex and vary with the species, region, method, and dynamic range, and between in vivo and ex vivo measurements. To reconcile this variability, we investigated in vivo and ex vivo stiffness properties of two distinct regions in the human and mouse brain - the hippocampus (HP) and the corpus callosum (CC) - using different methods. Under quasi-static conditions, we examined ex vivo murine HP and CC by atomic force microscopy (AFM). Between 16 and 40Hz, we investigated the in vivo brains of healthy volunteers by magnetic resonance elastography (MRE) in a 3-T clinical scanner. At high-frequency stimulation between 1000 and 1400Hz, we investigated the murine HP and CC ex vivo and in vivo with MRE in a 7-T preclinical system. HP and CC showed pronounced stiffness dispersion, as reflected by a factor of 32-36 increase in shear modulus from AFM to low-frequency human MRE and a 25-fold higher shear wave velocity in murine MRE than in human MRE. At low frequencies, HP was softer than CC, in both ex vivo mouse specimens (p < 0.05) and in vivo human brains (p < 0.01) while, at high frequencies, CC was softer than HP under in vivo (p < 0.01) and ex vivo (p < 0.05) conditions. The standard linear solid model comprising three elements reproduced the observed HP and CC stiffness dispersions, while other two- and three-element models failed. Our results indicate a remarkable consistency of brain stiffness across species, ex vivo and in vivo states, and different measurement techniques when marked viscoelastic dispersion properties combining equilibrium and non-equilibrium mechanical elements are considered.


Asunto(s)
Cuerpo Calloso , Diagnóstico por Imagen de Elasticidad , Humanos , Animales , Ratones , Cuerpo Calloso/diagnóstico por imagen , Imagen por Resonancia Magnética , Encéfalo/diagnóstico por imagen , Hipocampo/diagnóstico por imagen , Diagnóstico por Imagen de Elasticidad/métodos
6.
Front Bioeng Biotechnol ; 10: 1056131, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36532573

RESUMEN

Purpose: Magnetic resonance elastography (MRE) generates quantitative maps of the mechanical properties of biological soft tissues. However, published values obtained by brain MRE vary largely and lack detail resolution, due to either true biological effects or technical challenges. We here introduce cerebral tomoelastography in two and three dimensions for improved data consistency and detail resolution while considering aging, brain parenchymal fraction (BPF), systolic blood pressure, and body mass index (BMI). Methods: Multifrequency MRE with 2D- and 3D-tomoelastography postprocessing was applied to the brains of 31 volunteers (age range: 22-61 years) for analyzing the coefficient of variation (CV) and effects of biological factors. Eleven volunteers were rescanned after 1 day and 1 year to determine intraclass correlation coefficient (ICC) and identify possible long-term changes. Results: White matter shear wave speed (SWS) was slightly higher in 2D-MRE (1.28 ± 0.02 m/s) than 3D-MRE (1.22 ± 0.05 m/s, p < 0.0001), with less variation after 1 day in 2D (0.33 ± 0.32%) than in 3D (0.96 ± 0.66%, p = 0.004), which was also reflected in a slightly lower CV and higher ICC in 2D (1.84%, 0.97 [0.88-0.99]) than in 3D (3.89%, 0.95 [0.76-0.99]). Remarkably, 3D-MRE was sensitive to a decrease in white matter SWS within only 1 year, whereas no change in white matter volume was observed during this follow-up period. Across volunteers, stiffness correlated with age and BPF, but not with blood pressure and BMI. Conclusion: Cerebral tomoelastography provides high-resolution viscoelasticity maps with excellent consistency. Brain MRE in 2D shows less variation across volunteers in shorter scan times than 3D-MRE, while 3D-MRE appears to be more sensitive to subtle biological effects such as aging.

7.
Magn Reson Med ; 88(4): 1840-1850, 2022 10.
Artículo en Inglés | MEDLINE | ID: mdl-35691940

RESUMEN

PURPOSE: Magnetic resonance elastography (MRE) maps the viscoelastic properties of soft tissues for diagnostic purposes. However, different MRE inversion methods yield different results, which hinder comparison of values, standardization, and establishment of quantitative MRE markers. Here, we introduce an expandable, open-access, webserver-based platform that offers multiple inversion techniques for multifrequency, 3D MRE data. METHODS: The platform comprises a data repository and standard MRE inversion methods including local frequency estimation (LFE), direct-inversion based multifrequency dual elasto-visco (MDEV) inversion, and wavenumber-based (k-) MDEV. The use of the platform is demonstrated in phantom data and in vivo multifrequency MRE data of the kidneys and brains of healthy volunteers. RESULTS: Detailed maps of stiffness were generated by all inversion methods showing similar detail of anatomy. Specifically, the inner renal cortex had higher shear wave speed (SWS) than renal medulla and outer cortex without lateral differences. k-MDEV yielded higher SWS values than MDEV or LFE (full kidney/brain k-MDEV: 2.71 ± 0.19/1.45 ± 0.14 m/s, MDEV: 2.14 ± 0.16/0.99 ± 0.11 m/s, LFE: 2.12 ± 0.15/0.89 ± 0.06 m/s). CONCLUSION: The freely accessible platform supports the comparison of MRE results obtained with different inversion methods, filter thresholds, or excitation frequencies, promoting reproducibility in MRE across community-developed methods.


Asunto(s)
Diagnóstico por Imagen de Elasticidad , Encéfalo/anatomía & histología , Encéfalo/diagnóstico por imagen , Diagnóstico por Imagen de Elasticidad/métodos , Humanos , Riñón/diagnóstico por imagen , Imagen por Resonancia Magnética/métodos , Reproducibilidad de los Resultados
8.
Invest Radiol ; 57(2): 77-84, 2022 02 01.
Artículo en Inglés | MEDLINE | ID: mdl-34380993

RESUMEN

OBJECTIVE: A method for measuring intracranial pressure (ICP) noninvasively has long been sought after in neurology and neurosurgery. Treatment failure in individuals presenting with unspecific symptoms such as headache, gait disturbance, or visual impairment occurring in response to increased ICP can lead to irreversible brain injury, progressive disability, and death. Guidelines for diagnostic ICP measurement recommend intracranial placement of pressure tip catheters or lumbar puncture (LP) despite their invasiveness and possible complications. As ICP fluctuations are closely associated with changes in brain stiffness, ultrasound elastography could be a valid method to detect ICP noninvasively and with short examination times. MATERIALS AND METHODS: In this pilot study, we have investigated the use of time-harmonic shear waves, introduced into the brain by an external shaker, and measured in real-time by transtemporal ultrasound, for deducing a noninvasive imaging marker sensitive to elevated ICP. To this end, we developed cerebral ultrasound time-harmonic elastography for the noninvasive quantification of shear wave speed (SWS) as a surrogate marker of cerebral stiffness in a short examination time of a few minutes. RESULTS: We found that SWS in patients enrolled for LP with confirmed intracranial hypertension was 1.81 ± 0.10 m/s, distinguishing them from healthy volunteers with excellent diagnostic accuracy (1.55 ± 0.08 m/s; P < 0.001; area under the curve, 0.99). Interestingly, values in symptomatic patients decreased to normal stiffness immediately after LP (1.56 ± 0.06 m/s, P < 0.001). Moreover, invasively measured opening pressure correlated with SWS measured before LP and liquid volume drained through the spinal tap with the SWS difference between the 2 measurements. CONCLUSIONS: Collectively, our results suggest a tight link between cerebral stiffness and ICP and demonstrate that intracranial hypertension can be detected noninvasively within short examination times, opening avenues for diagnostic applications of cerebral ultrasound time-harmonic elastography in neurology and emergency medicine.


Asunto(s)
Diagnóstico por Imagen de Elasticidad , Hipertensión Intracraneal , Diagnóstico por Imagen de Elasticidad/métodos , Humanos , Hipertensión Intracraneal/diagnóstico por imagen , Presión Intracraneal/fisiología , Proyectos Piloto , Ultrasonografía
9.
Acta Biomater ; 138: 410-421, 2022 01 15.
Artículo en Inglés | MEDLINE | ID: mdl-34757062

RESUMEN

In 1868, French neurologist Jean-Martin Charcot coined the term multiple sclerosis (MS) after his observation that numerous white matter (WM) glial scars felt like sclerotic tissue. Nowadays, magnetic resonance elastography (MRE) can generate images with contrast of stiffness (CS) in soft in vivo tissues and may therefore be sensitive to MS lesions, provided that sclerosis is indeed a mechanical signature of this disease. We analyzed CS in a total of 147 lesions in patients with relapsing-remitting MS, compared with control regions in contralateral brain regions, and phantom data as well as performed numerical simulations to determine the delineation limits of multifrequency MRE (20 - 40 Hz) in MS. MRE analysis of simulated waves revealed a delineation limit of approximately 10% CS for detecting 9-mm lesions (mean size in our patient population). Due to inversion bias, this limit is reached when true CS is -11% for soft and 35% for stiff lesions. In vivo MRE identified 35 stiffer lesions and 17 softer lesions compared with surrounding WM (mean stiffness: 934±82 Pa). However, a similar pattern was found in the contralateral brain, suggesting that the range of stiffness changes in WM lesions due to MS is within the normal range of WM variability and normal heterogeneity-related CS. Consequently, Charcot's original intuition that MS is a focal sclerotic disease can neither be dismissed nor confirmed by in vivo MRE. However, the observation that MS lesions do not markedly differ in stiffness from surrounding brain tissue suggests that marked tissue sclerosis is not a mechanical signature of MS. STATEMENT OF SIGNIFICANCE: Multiple sclerosis (MS) was named by J.M. Charcot after the sclerotic changes in brain tissue he found in post-mortem autopsies. Since then, nothing has been revealed about the actual stiffening of MS lesions in vivo. Studying the viscoelastic properties of plaques in their natural environment is a major challenge that can only be overcome by MR elastography (MRE). Therefore, we used multifrequency MRE to answer the question whether MS lesions in patients with a relapsing-remitting disease course are mechanically different than surrounding tissue. Our findings suggest that the range of stiffness changes in white matter lesions due to MS is within the normal range of white matter variability and in vivo tissue sclerosis might not be a mechanical signature of MS.


Asunto(s)
Esclerosis Múltiple , Sustancia Blanca , Encéfalo/diagnóstico por imagen , Encéfalo/patología , Humanos , Imagen por Resonancia Magnética , Masculino , Esclerosis Múltiple/diagnóstico por imagen , Esclerosis Múltiple/patología , Esclerosis/patología , Sustancia Blanca/diagnóstico por imagen
10.
Front Bioeng Biotechnol ; 10: 1042711, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36698634

RESUMEN

The liver is the central metabolic organ. It constantly adapts its metabolic capacity to current physiological requirements. However, the relationship between tissue structure and hepatic function is incompletely understood; this results in a lack of diagnostic markers in medical imaging that can provide information about the liver's metabolic capacity. Therefore, using normal rabbit livers, we combined magnetic resonance elastography (MRE) with proteomics-based kinetic modeling of central liver metabolism to investigate the potential role of MRE for predicting the liver's metabolic function in vivo. Nineteen New Zealand white rabbits were investigated by multifrequency MRE and positron emission tomography (PET). This yielded maps of shear wave speed (SWS), penetration rate (PR) and standardized uptake value (SUV). Proteomic analysis was performed after the scans. Hepatic metabolic functions were assessed on the basis of the HEPATOKIN1 model in combination with a model of hepatic lipid-droplet metabolism using liquid chromatography-mass spectrometry. Our results showed marked differences between individual livers in both metabolic functions and stiffness properties, though not in SUV. When livers were divided into 'stiff' and 'soft' subgroups (cutoff SWS = 1.6 m/s), stiff livers showed a lower capacity for triacylglycerol storage, while at the same time showing an increased capacity for gluconeogenesis and cholesterol synthesis. Furthermore, SWS was correlated with gluconeogenesis and PR with urea production and glutamine exchange. In conclusion, our study indicates a close relationship between the viscoelastic properties of the liver and metabolic function. This could be used in future studies to predict non-invasively the functional reserve capacity of the liver in patients.

11.
Soft Matter ; 17(47): 10744-10752, 2021 Dec 08.
Artículo en Inglés | MEDLINE | ID: mdl-34787626

RESUMEN

Biomechanical changes are critical for cancer progression. However, the relationship between the rheology of single cells measured ex-vivo and the living tumor is not yet understood. Here, we combined single-cell rheology of cells isolated from primary tumors with in vivo bulk tumor rheology in patients with brain tumors. Eight brain tumors (3 glioblastoma, 3 meningioma, 1 astrocytoma, 1 metastasis) were investigated in vivo by magnetic resonance elastography (MRE), and after surgery by the optical stretcher (OS). MRE was performed in a 3-Tesla clinical MRI scanner and magnitude modulus |G*|, loss angle φ, storage modulus G', and loss modulus G'' were derived. OS experiments measured cellular creep deformation in response to laser-induced step stresses. We used a Kelvin-Voigt model to deduce two parameters related to cellular stiffness (µKV) and cellular viscosity (ηKV) from OS measurements in a time regimen that overlaps with that of MRE. We found that single-cell µKV was correlated with |G*| (R = 0.962, p < 0.001) and G'' (R = 0.883, p = 0.004) but not G' of the bulk tissue. These results suggest that single-cell stiffness affects tissue viscosity in brain tumors. The observation that viscosity parameters of individual cells and bulk tissue were not correlated suggests that collective mechanical interactions (i.e. emergent effects or cellular unjamming) of many cancer cells, which depend on cellular stiffness, influence the mechanical dissipation behavior of the bulk tissue. Our results are important to understand the emergent rheology of active multiscale compound materials such as brain tumors and its role in disease progression.


Asunto(s)
Neoplasias Encefálicas , Diagnóstico por Imagen de Elasticidad , Encéfalo , Neoplasias Encefálicas/diagnóstico por imagen , Elasticidad , Humanos , Imagen por Resonancia Magnética , Reología , Viscosidad
12.
Magn Reson Med ; 86(5): 2552-2561, 2021 11.
Artículo en Inglés | MEDLINE | ID: mdl-34184306

RESUMEN

PURPOSE: In vivo MR elastography (MRE) holds promise as a neuroimaging marker. In cerebral MRE, shear waves are introduced into the brain, which also stimulate vibrations in adjacent CSF, resulting in blurring and biased stiffness values near brain surfaces. We here propose inversion-recovery MRE (IR-MRE) to suppress CSF signal and improve stiffness quantification in brain surface areas. METHODS: Inversion-recovery MRE was demonstrated in agar-based phantoms with solid-fluid interfaces and 11 healthy volunteers using 31.25-Hz harmonic vibrations. It was performed by standard single-shot, spin-echo EPI MRE following 2800-ms IR preparation. Wave fields were acquired in 10 axial slices and analyzed for shear wave speed (SWS) as a surrogate marker of tissue stiffness by wavenumber-based multicomponent inversion. RESULTS: Phantom SWS values near fluid interfaces were 7.5 ± 3.0% higher in IR-MRE than MRE (P = .01). In the brain, IR-MRE SNR was 17% lower than in MRE, without influencing parenchymal SWS (MRE: 1.38 ± 0.02 m/s; IR-MRE: 1.39 ± 0.03 m/s; P = .18). The IR-MRE tissue-CSF interfaces appeared sharper, showing 10% higher SWS near brain surfaces (MRE: 1.01 ± 0.03 m/s; IR-MRE: 1.11 ± 0.01 m/s; P < .001) and 39% smaller ventricle sizes than MRE (P < .001). CONCLUSIONS: Our results show that brain MRE is affected by fluid oscillations that can be suppressed by IR-MRE, which improves the depiction of anatomy in stiffness maps and the quantification of stiffness values in brain surface areas. Moreover, we measured similar stiffness values in brain parenchyma with and without fluid suppression, which indicates that shear wavelengths in solid and fluid compartments are identical, consistent with the theory of biphasic poroelastic media.


Asunto(s)
Diagnóstico por Imagen de Elasticidad , Encéfalo/diagnóstico por imagen , Imagen Eco-Planar , Humanos , Imagen por Resonancia Magnética , Fantasmas de Imagen , Vibración
13.
J Mech Behav Biomed Mater ; 121: 104645, 2021 09.
Artículo en Inglés | MEDLINE | ID: mdl-34166871

RESUMEN

PURPOSE: Many elastography studies have shown that liver stiffness increases with fibrosis and thus can be used as a reliable marker for noninvasively staging fibrosis. However, the sensitivity of viscosity-related mechanical parameters, such as shear wave dispersion, to liver fibrosis is less well understood. METHODS: In this proof-of-concept study, 15 healthy volunteers and 37 patients with chronic liver disease and biopsy-proven fibrosis were prospectively investigated by MR elastography at six drive frequencies of 35-60 Hz. Maps of shear wave speed (SWS, in m/s) and loss angle (φ, in rad), as a marker of stiffness and viscous properties, respectively, were generated using tomoelastography data processing. The Child-Pugh score was used to assess cirrhosis severity. RESULTS: While SWS increased with fibrosis (F0: 1.53 ± 0.11 m/s, F1-F3: 1.71 ± 0.17 m/s, F4: 2.50 ± 0.39 m/s; P < 0.001), φ remained unchanged during mild to severe fibrosis (F0: 0.63 ± 0.05 rad, F1-F3: 0.60 ± 0.05 rad, P = 0.21) but increased in cirrhosis (F4: 0.81 ± 0.16 rad; P < 0.001). Correspondingly, the slope of SWS-dispersion within the investigated range of vibration frequencies increased from insignificant (F0-F3: 0.010 ± 0.007 m/s/Hz) to significant (F4: 0.038 ± 0.025 m/s/Hz; P = 0.005). Significant correlation with the Child-Pugh score was found for φ (R = 0.60, P = 0.01) but not for SWS. CONCLUSION: Although cirrhosis is associated with liver stiffening and, intuitively, transition towards more rigid material properties, the observed increases in φ and slope of SWS-dispersion indicate abnormally high mechanical friction in cirrhotic livers. This biophysical signature might provide a prognostic imaging marker for the detection of pathological processes associated with fibrosis independent of stiffness.


Asunto(s)
Diagnóstico por Imagen de Elasticidad , Biopsia , Humanos , Hígado/diagnóstico por imagen , Cirrosis Hepática/diagnóstico por imagen , Viscosidad
14.
Front Bioeng Biotechnol ; 9: 666456, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34026743

RESUMEN

Modulation of cerebral blood flow and vascular compliance plays an important role in the regulation of intracranial pressure (ICP) and also influences the viscoelastic properties of brain tissue. Therefore, magnetic resonance elastography (MRE), the gold standard for measuring in vivo viscoelasticity of brain tissue, is potentially sensitive to cerebral autoregulation. In this study, we developed a multifrequency MMRE technique that provides serial maps of viscoelasticity at a frame rate of nearly 6 Hz without gating, i.e., in quasi-real time (rt-MMRE). This novel method was used to monitor rapid changes in the viscoelastic properties of the brains of 17 volunteers performing the Valsalva maneuver (VM). rt-MMRE continuously sampled externally induced vibrations comprising three frequencies of 30.03, 30.91, and 31.8 Hz were over 90 s using a steady-state, spiral-readout gradient-echo sequence. Data were processed by multifrequency dual elasto-visco (MDEV) inversion to generate maps of magnitude shear modulus | G∗| (stiffness) and loss angle φ at a frame rate of 5.4 Hz. As controls, the volunteers were examined to study the effects of breath-hold following deep inspiration and breath-hold following expiration. We observed that | G∗| increased while φ decreased due to VM and, less markedly, due to breath-hold in inspiration. Group mean VM values showed an early overshoot of | G∗| 2.4 ± 1.2 s after the onset of the maneuver with peak values of 6.7 ± 4.1% above baseline, followed by a continuous increase in stiffness during VM. A second overshoot of | G∗| occurred 5.5 ± 2.0 s after the end of VM with peak values of 7.4 ± 2.8% above baseline, followed by 25-s sustained recovery until the end of image acquisition. φ was constantly reduced by approximately 2% during the entire VM without noticeable peak values. This is the first report of viscoelasticity changes in brain tissue induced by physiological maneuvers known to alter ICP and detected by clinically applicable rt-MMRE. Our results show that apnea and VM slightly alter brain properties toward a more rigid-solid behavior. Overshooting stiffening reactions seconds after onset and end of VM reveal rapid autoregulatory processes of brain tissue viscoelasticity.

15.
Sci Rep ; 11(1): 9820, 2021 05 10.
Artículo en Inglés | MEDLINE | ID: mdl-33972639

RESUMEN

Spatial heterogeneity of hepatic fibrosis in primary sclerosing cholangitis (PSC) in comparison to viral hepatitis was assessed as a potential new biomarker using MR elastography (MRE). In this proof-of-concept study, we hypothesized a rather increased heterogeneity in PSC and a rather homogeneous distribution in viral hepatitis. Forty-six consecutive subjects (PSC: n = 20, viral hepatitis: n = 26) were prospectively enrolled between July 2014 and April 2017. Subjects underwent multifrequency MRE (1.5 T) using drive frequencies of 35-60 Hz and generating shear-wave speed (SWS in m/s) maps as a surrogate of stiffness. The coefficient of variation (CV in %) was determined to quantify fibrosis heterogeneity. Mean SWS and CV were 1.70 m/s and 21% for PSC, and 1.84 m/s and 18% for viral hepatitis. Fibrosis heterogeneity was significantly increased for PSC (P = 0.04) while no difference was found for SWS of PSC and viral hepatitis (P = 0.17). Global hepatic stiffness was similar in PSC and viral hepatitis groups, but spatial heterogeneity may reveal spatial patterns of stiffness changes towards enhanced biophysics-based diagnosis by MRI.


Asunto(s)
Colangitis Esclerosante/patología , Diagnóstico por Imagen de Elasticidad/métodos , Hepatitis Viral Humana/patología , Cirrosis Hepática/diagnóstico , Imagen por Resonancia Magnética/métodos , Adulto , Anciano , Femenino , Humanos , Hígado/diagnóstico por imagen , Hígado/patología , Cirrosis Hepática/patología , Masculino , Persona de Mediana Edad , Estudios Prospectivos
16.
Acta Biomater ; 121: 393-404, 2021 02.
Artículo en Inglés | MEDLINE | ID: mdl-33326885

RESUMEN

There is growing awareness that brain mechanical properties are important for neural development and health. However, published values of brain stiffness differ by orders of magnitude between static measurements and in vivo magnetic resonance elastography (MRE), which covers a dynamic range over several frequency decades. We here show that there is no fundamental disparity between static mechanical tests and in vivo MRE when considering large-scale properties, which encompass the entire brain including fluid filled compartments. Using gradient echo real-time MRE, we investigated the viscoelastic dispersion of the human brain in, so far, unexplored dynamic ranges from intrinsic brain pulsations at 1 Hz to ultralow-frequency vibrations at 5, 6.25, 7.8 and 10 Hz to the normal frequency range of MRE of 40 Hz. Surprisingly, we observed variations in brain stiffness over more than two orders of magnitude, suggesting that the in vivo human brain is superviscous on large scales with very low shear modulus of 42±13 Pa and relatively high viscosity of 6.6±0.3 Pa∙s according to the two-parameter solid model. Our data shed light on the crucial role of fluid compartments including blood vessels and cerebrospinal fluid (CSF) for whole brain properties and provide, for the first time, an explanation for the variability of the mechanical brain responses to manual palpation, local indentation, and high-dynamic tissue stimulation as used in elastography.


Asunto(s)
Diagnóstico por Imagen de Elasticidad , Encéfalo/diagnóstico por imagen , Elasticidad , Humanos , Imagen por Resonancia Magnética , Vibración , Viscosidad
17.
Magn Reson Med ; 85(4): 1962-1973, 2021 04.
Artículo en Inglés | MEDLINE | ID: mdl-33104294

RESUMEN

PURPOSE: With abdominal magnetic resonance elastography (MRE) often suffering from breathing artifacts, it is recommended to perform MRE during breath-hold. However, breath-hold acquisition prohibits extended multifrequency MRE examinations and yields inconsistent results when patients cannot hold their breath. The purpose of this work was to analyze free-breathing strategies in multifrequency MRE of abdominal organs. METHODS: Abdominal MRE with 30, 40, 50, and 60 Hz vibration frequencies and single-shot, multislice, full wave-field acquisition was performed four times in 11 healthy volunteers: once with multiple breath-holds and three times during free breathing with ungated, gated, and navigated slice adjustment. Shear wave speed maps were generated by tomoelastography inversion. Image registration was applied for correction of intrascan misregistration of image slices. Sharpness of features was quantified by the variance of the Laplacian. RESULTS: Total scan times ranged from 120 seconds for ungated free-breathing MRE to 376 seconds for breath-hold examinations. As expected, free-breathing MRE resulted in larger organ displacements (liver, 4.7 ± 1.5 mm; kidneys, 2.4 ± 2.2 mm; spleen, 3.1 ± 2.4 mm; pancreas, 3.4 ± 1.4 mm) than breath-hold MRE (liver, 0.7 ± 0.2 mm; kidneys, 0.4 ± 0.2 mm; spleen, 0.5 ± 0.2 mm; pancreas, 0.7 ± 0.5 mm). Nonetheless, breathing-related displacement did not affect mean shear wave speed, which was consistent across all protocols (liver, 1.43 ± 0.07 m/s; kidneys, 2.35 ± 0.21 m/s; spleen, 2.02 ± 0.15 m/s; pancreas, 1.39 ± 0.15 m/s). Image registration before inversion improved the quality of free-breathing examinations, yielding no differences in image sharpness to uncorrected breath-hold MRE in most organs (P > .05). CONCLUSION: Overall, multifrequency MRE is robust to breathing when considering whole-organ values. Respiration-related blurring can readily be corrected using image registration. Consequently, ungated free-breathing MRE combined with image registration is recommended for multifrequency MRE of abdominal organs.


Asunto(s)
Diagnóstico por Imagen de Elasticidad , Abdomen/diagnóstico por imagen , Artefactos , Humanos , Hígado/diagnóstico por imagen , Imagen por Resonancia Magnética , Respiración
18.
Invest Radiol ; 55(12): 769-774, 2020 12.
Artículo en Inglés | MEDLINE | ID: mdl-32796197

RESUMEN

OBJECTIVES: Estimations of tumor volume and boundary in pancreatic ductal adenocarcinoma (PDAC) are crucial for surgery planning. The aim of the study is to evaluate tomoelastography for detection of PDAC and quantification of PDAC volume based on tissue stiffness. MATERIALS AND METHODS: From March 2018 to December 2019, a total of 102 participants (30 healthy participants and 72 patients with histologically proven PDAC) were prospectively enrolled in a multicenter study. Multifrequency magnetic resonance elastography was combined with tomoelastography postprocessing to generate maps of shear wave speed (SWS) depicting highly resolved anatomical details of tissue stiffness. Subregional analysis of pancreatic head, body, and tail and reproducibility tests were performed in healthy participants, whereas tumorous (PDAC-T) and nontumorous (PDAC-NT) pancreatic tissue analysis was conducted in patients. In all patients, tumor volumes measured by computed tomography (CT) were compared with SWS-derived volumes. In addition, in 32 patients, tumor sizes were evaluated by macroscopy after resection. RESULTS: Tumor volumes were quantified in 99% and 87% of all cases with tomoelastography and CT, respectively. Pancreatic SWS was highly reproducible (repeatability coefficient = 0.12) and did not vary regionally or with patient age, sex, or body mass index (all P > 0.08). Shear wave speed was higher in PDAC-T (2.08 ± 0.38 m/s) than in healthy (1.25 ± 0.09 m/s; P < 0.001) and PDAC-NT (1.28 ± 0.14 m/s; P < 0.001) participants. A threshold of 1.47 m/s separated PDAC-T from healthy volunteers (area under the curve = 1.0, sensitivity = 100%, specificity = 100%), while 1.49 m/s separated PDAC-T from PDAC-NT with high accuracy (area under the curve = 0.99, sensitivity = 90%, specificity = 100%). Tomoelastography-derived tumor volume correlated with CT volume (r = 0.91, P < 0.001) and ex vivo tumor volume (r = 0.66, P < 0.001). CONCLUSIONS: Tomoelastography provides a quantitative imaging marker for tissue stiffness depicting PDAC boundaries and separates PDAC from unaffected pancreatic tissue.


Asunto(s)
Adenocarcinoma/diagnóstico por imagen , Adenocarcinoma/patología , Diagnóstico por Imagen de Elasticidad , Fenómenos Mecánicos , Neoplasias Pancreáticas/diagnóstico por imagen , Neoplasias Pancreáticas/patología , Carga Tumoral , Adulto , Fenómenos Biomecánicos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados
19.
Front Physiol ; 11: 616984, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-33505319

RESUMEN

Hydration influences blood volume, blood viscosity, and water content in soft tissues - variables that determine the biophysical properties of biological tissues including their stiffness. In the brain, the relationship between hydration and stiffness is largely unknown despite the increasing importance of stiffness as a quantitative imaging marker. In this study, we investigated cerebral stiffness (CS) in 12 healthy volunteers using ultrasound time-harmonic elastography (THE) in different hydration states: (i) during normal hydration, (ii) after overnight fasting, and (iii) within 1 h of drinking 12 ml of water per kg body weight. In addition, we correlated shear wave speed (SWS) with urine osmolality and hematocrit. SWS at normal hydration was 1.64 ± 0.02 m/s and decreased to 1.57 ± 0.04 m/s (p < 0.001) after overnight fasting. SWS increased again to 1.63 ± 0.01 m/s within 30 min of water drinking, returning to values measured during normal hydration (p = 0.85). Urine osmolality at normal hydration (324 ± 148 mOsm/kg) increased to 784 ± 107 mOsm/kg (p < 0.001) after fasting and returned to normal (288 ± 128 mOsm/kg, p = 0.83) after water drinking. SWS and urine osmolality correlated linearly (r = -0.68, p < 0.001), while SWS and hematocrit did not correlate (p = 0.31). Our results suggest that mild dehydration in the range of diurnal fluctuations is associated with significant softening of brain tissue, possibly due to reduced cerebral perfusion. To ensure consistency of results, it is important that cerebral elastography with a standardized protocol is performed during normal hydration.

20.
Cancer Res ; 79(22): 5704-5710, 2019 Nov 15.
Artículo en Inglés | MEDLINE | ID: mdl-31551364

RESUMEN

Patients with increased liver stiffness have a higher risk of developing cancer, however, the role of fluid-solid tissue interactions and their contribution to liver tumor malignancy remains elusive. Tomoelastography is a novel imaging method for mapping quantitatively the solid-fluid tissue properties of soft tissues in vivo. It provides high resolution and thus has clear clinical applications. In this work we used tomoelastography in 77 participants, with a total of 141 focal liver lesions of different etiologies, to investigate the contributions of tissue stiffness and fluidity to the malignancy of liver tumors. Shear-wave speed (c) as surrogate for tissue stiffness and phase-angle (φ) of the complex shear modulus reflecting tissue fluidity were abnormally high in malignant tumors and allowed them to be distinguished from nontumorous liver tissue with high accuracy [c: AUC = 0.88 with 95% confidence interval (CI) = 0.83-0.94; φ: AUC = 0.95, 95% CI = 0.92-0.98]. Benign focal nodular hyperplasia and hepatocellular adenoma could be distinguished from malignant lesions on the basis of tumor stiffness (AUC = 0.85, 95% CI = 0.72-0.98; sensitivity = 94%, 95% CI = 89-100; and specificity = 85%, 95% CI = 62-100), tumor fluidity (AUC = 0.86, 95% CI = 0.77-0.96; sensitivity = 83%, 95% CI = 72-93; and specificity = 92%, 95% CI = 77-100) and liver stiffness (AUC = 0.84, 95% CI = 0.74-0.94; sensitivity = 72%, 95% CI = 59-83; and specificity = 88%, 95% CI = 69-100), but not on the basis of liver fluidity. Together, hepatic malignancies are characterized by stiff, yet fluid tissue properties, whereas surrounding nontumorous tissue is dominated by solid properties. Tomoelastography can inform noninvasively on the malignancy of suspicious liver lesions by differentiating between benign and malignant lesions with high sensitivity based on stiffness and with high specificity based on fluidity. SIGNIFICANCE: Solid-fluid tissue properties measured by tomoelastography can distinguish malignant from benign masses with high accuracy and provide quantitative noninvasive imaging biomarkers for liver tumors.


Asunto(s)
Carcinoma Hepatocelular/diagnóstico , Carcinoma Hepatocelular/patología , Neoplasias Hepáticas/diagnóstico , Neoplasias Hepáticas/patología , Hígado/patología , Adenoma de Células Hepáticas/diagnóstico , Adenoma de Células Hepáticas/patología , Adulto , Anciano , Anciano de 80 o más Años , Diagnóstico Diferencial , Diagnóstico por Imagen de Elasticidad/métodos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Sensibilidad y Especificidad , Adulto Joven
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...