Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Sensors (Basel) ; 24(18)2024 Sep 19.
Artículo en Inglés | MEDLINE | ID: mdl-39338816

RESUMEN

In technology and industrial production, many applications require wide-bandwidth current measurements. In this paper, a signal fusion scheme for a current sensor comprising tunneling magnetoresistance and a current transformer is proposed, achieving a flat frequency response in the DC to MHz range. The measurement principles in different cases of the scheme are introduced, and the total transfer function of the entire scheme is derived by analyzing each section separately. Furthermore, the feasibility and selected parameters of the scheme are verified through a systematic simulation utilizing the MATLAB software. Based on the proposed scheme, a group of principal prototypes are built to experimentally evaluate the bandwidth, amplitude and phase flatness, accuracy, sensitivity, and impulse response. The relative amplitude variation in the passband of the fusion sensor is less than 4%, and the estimated bandwidth of the fusion sensor is close to 17 MHz. The accuracy is better than 0.6%, even when measuring the current at 1 MHz, and the relative standard deviation is 5% when measuring the impulse signal. The sensors developed using this scheme, with a low financial cost, have advantages in many wide-bandwidth current measuring scenarios.

2.
Sensors (Basel) ; 17(7)2017 Jul 03.
Artículo en Inglés | MEDLINE | ID: mdl-28671621

RESUMEN

In this work, a linear birefringence measurement method is proposed for an optical fiber current sensor (OFCS). First, the optical configuration of the measurement system is presented. Then, the elimination method of the effect of the azimuth angles between the sensing fiber and the two polarizers is demonstrated. Moreover, the relationship of the linear birefringence, the Faraday rotation angle and the final output is determined. On these bases, the multi-valued problem on the linear birefringence is simulated and its solution is illustrated when the linear birefringence is unknown. Finally, the experiments are conducted to prove the feasibility of the proposed method. When the numbers of turns of the sensing fiber in the OFCS are about 15, 19, 23, 27, 31, 35, and 39, the measured linear birefringence obtained by the proposed method are about 1.3577, 1.8425, 2.0983, 2.5914, 2.7891, 3.2003 and 3.5198 rad. Two typical methods provide the references for the proposed method. The proposed method is proven to be suitable for the linear birefringence measurement in the full range without the limitation that the linear birefringence must be smaller than π/2.

3.
Sensors (Basel) ; 17(6)2017 May 26.
Artículo en Inglés | MEDLINE | ID: mdl-28587137

RESUMEN

Applying shielding coils is a practical way to protect current transformers (CTs) for large-capacity generators from the intensive magnetic interference produced by adjacent bus-bars. The aim of this study is to build a simple analytical model for the shielding coils, from which the optimization of the shielding coils can be calculated effectively. Based on an existing stray flux model, a new analytical model for the leakage flux of partial coils is presented, and finite element method-based simulations are carried out to develop empirical equations for the core-pickup factors of the models. Using the flux models, a model of the common four-segment shielding coils is derived. Furthermore, a theoretical analysis is carried out on the optimal performance of the four-segment shielding coils in a typical six-bus-bars scenario. It turns out that the "all parallel" shielding coils with a 45° starting position have the best shielding performance, whereas the "separated loop" shielding coils with a 0° starting position feature the lowest heating value. Physical experiments were performed, which verified all the models and the conclusions proposed in the paper. In addition, for shielding coils with other than the four-segment configuration, the analysis process will generally be the same.

4.
Artículo en Chino | MEDLINE | ID: mdl-24804476

RESUMEN

Electric and electronic products are required to pass through the certification on electrical safety performance before entering into the market in order to reduce electrical shock and electrical fire so as to protect the safety of people and property. The leakage current is the most important factor in testing the electrical safety performance and the test theory is based on the perception current effect and threshold. The traditional method testing the current threshold for perception only depends on the sensing of the human body and is affected by psychological factors. Some authors filter the effect of subjective sensation by using physiological and psychological statistical algorithm in recent years and the reliability and consistency of the experiment data are improved. We established an experiment system of testing the human hody's current threshold for perception based on EEG feature analysis, and obtained 967 groups of data. We used wavelet packet analysis to detect a wave from EEG, and used FFT to do spectral analysis on alpha wave before and after the current flew through the human body. The study has shown that about 97.72% alpha wave energy changes significantly when electrical stimulation occurs. It is well proved that when the EEG feature identification is applied to test the human body current threshold for perception, and meanwhile alpha wave energy change and human body sensing are used together to confirm if the current flowing through the human body reaches the perception threshold, the measurement of the human body current threshold for perception could be carried out objectively and accurately.


Asunto(s)
Electroencefalografía , Umbral Sensorial/fisiología , Análisis de Ondículas , Algoritmos , Estimulación Eléctrica , Humanos , Reproducibilidad de los Resultados
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA