1.
Medicina (Kaunas) ; 58(9)2022 Aug 29.
Artículo en Inglés | MEDLINE | ID: mdl-36143849

RESUMEN

Background: Loss of lumbar lordosis caused by single level degenerative spondylolisthesis can trigger significant sagittal plane imbalance and failure to correct lumbopelvic parameters during lumbar fusion can lead to poor outcome or worsening deformity. Anterior column release (ACR) through a pre-psoas approach allows the placement of a hyperlordotic cage (HLC) to improve lumbar lordosis, but it is unclear if the amount of cage lordosis affects radiological outcomes in real-life patient conditions. Methods: Three patients were treated with ACR and 30° expandable HLC for positive sagittal imbalance secondary to single-level spondylolisthesis. Patients reported baseline and post-operative Oswestry Disability Index (ODI) and Numeric Pain Score (NRS). Radiographic parameters of sagittal balance included lumbar lordosis (LL), sagittal vertical axis (SVA) and pelvic incidence-lumbar lordosis mismatch (PI-LL). Results: Surgical indications were sagittal plane imbalance caused by L4-L5 degenerative spondylolisthesis (n = 2) and L3-L4 spondylolisthesis secondary to adjacent segmental degeneration (n = 1). Average post-operative length of stay was 3 days (range 2-4) and estimated blood loss was 266 mL (range 200-300). NRS and ODI improved in all patients. All experienced improvements in LL (x¯preop = 33°, x¯postop = 56°), SVA (x¯preop = 180 mm, x¯postop = 61 mm) and PI-LL (x¯preop = 26°, x¯postop = 5°). Conclusion: ACR with expandable HLC can restore sagittal plane balance associated with single-level spondylolisthesis. Failure to perform ACR with HLC placement during pre-psoas interbody fusion may result in under correction of lordosis and poorer outcome for these patients.


Asunto(s)
Lordosis , Fusión Vertebral , Espondilolistesis , Humanos , Lordosis/etiología , Lordosis/cirugía , Vértebras Lumbares/cirugía , Estudios Retrospectivos , Espondilolistesis/complicaciones , Espondilolistesis/cirugía , Resultado del Tratamiento
2.
Clin Neurol Neurosurg ; 222: 107413, 2022 11.
Artículo en Inglés | MEDLINE | ID: mdl-36049402

RESUMEN

BACKGROUND: Spontaneous resolution of syringomyelia has rarely been reported in the literature. Rarer still are cases wherein this process is associated with pregnancy and parturition. We review theories on syringomyelia development and spontaneous resolution to better understand the role pregnancy and parturition may play in both processes. METHODS: We present a 30-year-old female with MRI-confirmed spontaneous syrinx regression following caesarean delivery of a full-term pregnancy. We additionally review the literature to identify previously reported cases of spontaneous syrinx regression both independent of and associated with pregnancy. RESULTS: Including the present case, 39 cases describing spontaneous regression of syringomyelia have been reported in the literature, of which only four are associated with pregnancy and parturition. 75% of all reported cases were associated with type I Chiari malformation, though several disorders of the craniocervical junction and spinal canal were implicated. Complete syrinx regression was achieved in 33.3% of cases and 5% of cases described recurrence of syringomyelia following the spontaneous resolution. CONCLUSION: Syringomyelia likely develops due to disturbance of the physiologic flow of cerebrospinal fluid around the craniocervical junction and the obex. Several mechanisms including fissuring of the spinal cord parenchyma and reduction of subarachnoid scarring are likely involved in this process. In the setting of pregnancy, additional mechanisms surrounding the increased intraabdominal forces imparted by a growing fetus, Valsalva-like strain experienced during labor, and hemodynamic changes that occur to accommodate gestation are likely implicated. Nevertheless, patients should continue to be monitored periodically for syrinx recurrence.


Asunto(s)
Malformación de Arnold-Chiari , Siringomielia , Embarazo , Femenino , Humanos , Adulto , Siringomielia/complicaciones , Siringomielia/diagnóstico por imagen , Malformación de Arnold-Chiari/complicaciones , Malformación de Arnold-Chiari/diagnóstico por imagen , Espacio Subaracnoideo , Imagen por Resonancia Magnética , Parto
3.
Asian Spine J ; 16(5): 615-624, 2022 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-35263829

RESUMEN

STUDY DESIGN: This study compares four cervical endplate removal procedures, validated by finite element models. PURPOSE: To characterize the effect of biomechanical strength and increased contact area on the maximum von Mises stress, migration, and subsidence between the cancellous bone, endplate, and implanted cage. OVERVIEW OF LITERATURE: Anterior cervical discectomy and fusion (ACDF) has been widely used for treating patients with degenerative spondylosis. However, no direct correlations have been drawn that incorporate the impact of the contact area between the cage and the vertebra/endplate. METHODS: Model 1 (M1) was an intact C2C6 model with a 0.5 mm endplate. In model 2 (M2), a cage was implanted after removal of the C4-C5 and C5-C6 discs with preservation of the osseous endplate. In model 3 (M3), 1 mm of the osseous endplate was removed at the upper endplate. Model 4 (M4) resembles M3, except that 3 mm of the osseous endplate was removed. RESULTS: The range of motion (ROM) at C2C6 in the M2-M4 models was reduced by at least 9º compared to the M1 model. The von Mises stress results in the C2C3 and C3C4 interbody discs were significantly smaller in the M1 model and slightly increased in the M2-M3 and M3-M4 models. Migration and subsidence decreased from the M2-M3 model, whereas further endplate removal increased the migration and subsidence as shown in the transition from M3 to M4. CONCLUSIONS: The M3 model had the least subsidence and migration. The ROM was higher in the M3 model than the M2 and M4 models. Endplate preparation created small stress differences in the healthy intervertebral discs above the ACDF site. A 1 mm embedding depth created the best balance of mechanical strength and contact area, resulting in the most favorable stability of the construct.

4.
World Neurosurg ; 163: e43-e52, 2022 07.
Artículo en Inglés | MEDLINE | ID: mdl-35176523

RESUMEN

BACKGROUND: The limitations of anterior cervical discectomy and fusion (ACDF) are related to mechanical failure of the construct after recurring subsidence and migration. In the present study, we evaluated the effect of the maximum rotation of variable angle screws on the range of motion (ROM), cage migration, and subsidence. METHODS: Five finite element models were developed from a C2-C7 cervical spine model. The first model was an intact C2-C7 spine model, and the second model was an altered C2-C7 model with C4-C6 cage insertion and a 2-level static plate. The other three models were altered C2-C7 models with the same C4-C6 cage insertion and a 2-level dynamic plate. RESULTS: The ROM of C4-C6 in the static plate model was reduced by ∼14° from the intact model but only reduced by ∼9° in the dynamic plate models. The maximum migration and subsidence at the cage-endplate interface in the dynamic plate models were lower than those in the static plate model for all moments. The von Mises stress of the C3-C4 and C6-C7 discs in the dynamic plate models was lower than that in the static plate model. CONCLUSIONS: Our results indicate that dynamic plating has promising potential (greater ROM and lower von Mises stress of discs) for stabilization in multilevel anterior cervical discectomy and fusion than static plating, although both dynamic and static plates showed lower ROM than the intact model. A lower screw rotational angle resulted in superior biomechanical performance (lower incidence of migration and subsidence) compared with a higher rotational angle in multilevel applications, regardless of loading.


Asunto(s)
Discectomía , Fusión Vertebral , Fenómenos Biomecánicos , Vértebras Cervicales/diagnóstico por imagen , Vértebras Cervicales/cirugía , Discectomía/métodos , Análisis de Elementos Finitos , Humanos , Rango del Movimiento Articular , Fusión Vertebral/métodos
5.
Spine J ; 21(5): 874-882, 2021 05.
Artículo en Inglés | MEDLINE | ID: mdl-33460810

RESUMEN

BACKGROUND CONTEXT: Anterior cervical discectomy and fusion (ACDF) is widely used to treat patients with spinal disorders, where the cage is a critical component to achieve satisfactory fusion results. However, it is still not clear whether a cage with screws or without screws will be the best choice for long-term fusion as the micromotion (sliding distance) and subsidence (penetration) of the cage still take place repeatedly. PURPOSE: This study aims to examine the effect of cage-screws on the biomechanical characteristics of the human spine, implanted cage, and associate hardware by comparing the micromotion and subsidence. STUDY DESIGN: A finite element (FE) analysis study. METHODS: A FE model of a C3-C5 cervical spine with ACDF was developed. The spinal segment was modeled with the removal of the anterior longitudinal ligament (ALL), posterior longitudinal ligament (PLL), and discectomy was then implanted with a cage-screw system. Three models were analyzed: the first was the original spine (S1 model), the second, S2, was implanted with cages and anterior plating, and the third, S3, was implanted with a cage-screw system in addition to the anterior plate. All investigations were under 1 N•m in flexion, extension, lateral bending, and axial rotation situations. RESULTS: Finite element analysis (FEA) demonstrated that range of motion (ROM) at C3-C4 in the S2 model was significantly reduced more than that in the S3 model, while the ROM at both C4-C5 in the S3 model was reduced more than that in the S2 model in all simulations. The ROM at C3-C5 in the S1 model was reduced by over 5° in the S2 and S3 models in all loading conditions. The micromotion and subsidence at all contacts of C3-C5 in the S3 model were lower than that in the S2 model in all flexion, extension, bending, and axial simulations. The subsidence and micromotion could be seen in the barrier area of the S2 model, while they occurred near the edge of the screw in the S3 model. CONCLUSIONS: These results showed that the cage-screw and anterior plating combination has promising potential to reduce the risk of micromotion and subsidence of implanted cages in two or more level ACDFs. CLINICAL SIGNIFICANCE: The use of double segmental fixation with cage-screw anterior plating combination constructs may increase the stiffness of the construct and reduce the incidence of clinical and radiographic pseudarthrosis following multilevel ACDF, which in turn, could decrease the need for revision surgeries or supplemental posterior fixation.


Asunto(s)
Fusión Vertebral , Fenómenos Biomecánicos , Tornillos Óseos , Vértebras Cervicales/diagnóstico por imagen , Vértebras Cervicales/cirugía , Discectomía , Análisis de Elementos Finitos , Humanos , Rango del Movimiento Articular
6.
World Neurosurg ; 133: 283-290, 2020 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-31505282

RESUMEN

BACKGROUND: Traditional manual retraction to access deep-seated brain lesions has been associated with complications related to vascular compromise of cerebral tissue. Various techniques have been developed over time to minimize injury, such as self-sustaining retractors, neuronavigation, and endoscopic approaches. Recently, tubular retractors, such as the ViewSite Brain Access System (VBAS), have been developed to reduce mechanical damage from retraction by dispersing the force of the retractor radially over the parenchyma. Therefore, we sought to review the current literature to accurately assess the indications, benefits, and complications associated with use of VBAS retractors. METHODS: A literature search for English articles published between 2005 and 2019 was performed using the MEDLINE database archive with the search terminology "Vycor OR ViewSite OR Brain-Access-System NOT glass." The VBAS website was also examined. Only articles detailing neurosurgical procedures using the VBAS tubular retractor system alone, or in combination with other retractors, were included. Postoperative morbidity and mortality were analyzed to estimate complications linked to using the retractor. RESULTS: Twelve publications (106 patients) met the inclusion criteria. The VBAS retractor was used for tumor resections, hematoma evacuations, cyst removal, foreign body extractions, and lesion resection in toxoplasmosis and multiple sclerosis. These cases were subdivided into groups based on lesion location, size, and resection volume for further analysis. Gross total resection was achieved in 63% of tumor excisions, and subtotal resection was achieved in 37%. Hematoma evacuation was successful in all cases. There were 3 short-term postoperative complications linked to the retractor, with an overall complication rate of 2.8%. CONCLUSIONS: This report is the first formal assessment of the VBAS, highlighting technical considerations of the retractor from the surgeon's perspective, patient outcomes, and complications. The retractor is a safe and efficacious tubular retraction system that can be used for tumor biopsy and resection, colloid cyst removal, hematoma evacuation, and removal of foreign bodies. However, further randomized controlled trials are indicated to accurately assess complication rates and outcomes.


Asunto(s)
Neoplasias Encefálicas/cirugía , Microcirugia/instrumentación , Procedimientos Neuroquirúrgicos/instrumentación , Instrumentos Quirúrgicos , Humanos
7.
Cureus ; 11(8): e5420, 2019 Aug 18.
Artículo en Inglés | MEDLINE | ID: mdl-31632873

RESUMEN

Sensorineural hearing loss (SNHL) is a common finding in cases of the congenital internal acoustic canal (IAC) stenosis. Previous reports reveal a relationship between IAC stenosis and facial palsy as well as vestibular dysfunction. This case identifies a patient with bilateral profound SNHL, bilateral IAC stenosis, and temporary unilateral facial palsy who went on to receive bilateral cochlear implants (CI). The facial nerve synkinesis that was found in this patient with hypoplastic IACs occurred after a cochlear implant activation. The synkinesis was ipsilateral to prior transient facial palsy after salmonella infection. Patients with IAC stenosis and cochlear nerve hypoplasia may respond well to cochlear implantation, but caution should be used when considering CI with an emphasis on counseling for possible facial nerve complications.

8.
Int J Pediatr Otorhinolaryngol ; 117: 127-130, 2019 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-30579066

RESUMEN

INTRODUCTION: Although injection laryngoplasty (IL) is a well-accepted treatment strategy in older children and adults with unilateral vocal fold immobility (UVFI), its efficacy and safety have not been well studied in neonates and young children. OBJECTIVES: The main objective of this study was to evaluate the clinical and radiographic effects of IL on aspiration & dysphagia in neonates and young children with UVFI. METHODS: This was a retrospective chart review of infants and children who underwent IL at a tertiary children's hospital. The primary endpoints were improved aspiration and avoidance of gastrostomy tube placement. Additional endpoints included adverse airway and swallowing effects of IL. RESULTS: Eight patients were included in this case series. A total of 10 injection laryngoplasties were performed. Average corrected age of patients undergoing IL was 1.22 years(range 0.5-3.6 y). Seven out of 8 patients had preoperative modified barium swallow (MBS). Five out of seven showed improvement in aspiration. Three out of six (50%) patients who did not have gastrostomy tube preoperatively, were able to avoid gastrostomy tube. No adverse effects were noted following IL. One patient with severe tracheomalacia ultimately required tracheostomy 5 months after IL. CONCLUSION: Injection laryngoplasty appears to be a safe and effective therapeutic option in neonates and young children with unilateral vocal cord immobility and associated aspiration. It may be an effective treatment to improve aspiration and avoid gastrostomy tube placement. Further investigation is warranted. LEVEL OF EVIDENCE: 4.


Asunto(s)
Trastornos de Deglución/cirugía , Laringoplastia/métodos , Aspiración Respiratoria/cirugía , Parálisis de los Pliegues Vocales/cirugía , Preescolar , Deglución , Trastornos de Deglución/diagnóstico por imagen , Trastornos de Deglución/etiología , Femenino , Gastrostomía , Humanos , Lactante , Recién Nacido , Laringoplastia/efectos adversos , Masculino , Aspiración Respiratoria/etiología , Estudios Retrospectivos , Resultado del Tratamiento , Parálisis de los Pliegues Vocales/complicaciones , Parálisis de los Pliegues Vocales/diagnóstico por imagen
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...