Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Med J Malaysia ; 76(1): 98-100, 2021 01.
Artículo en Inglés | MEDLINE | ID: mdl-33510117

RESUMEN

Around June 2020, many institutions restarted full operating schedules to clear the backlog of postponed surgeries because of the first wave in the COVID-19 pandemic. In an online survey distributed among anaesthestists in Asian countries at that time, most of them described their safety concerns and recommendations related to the supply of personal protective equipment and its usage. The second concern was related to pre-operative screening for all elective surgical cases and its related issues. The new norm in practice was found to be non-standardized and involved untested devices or workflow that have since been phased out with growing evidence. Subsequent months after reinstating full elective surgeries tested the ability of many hospitals in handling the workload of non-COVID surgical cases together with rising COVID-19 positive cases in the second and third waves when stay-at-home orders eased.


Asunto(s)
Anestesistas , COVID-19/diagnóstico , COVID-19/prevención & control , Exposición Profesional/prevención & control , Salud Laboral , Equipo de Protección Personal/provisión & distribución , Procedimientos Quirúrgicos Electivos , Humanos , Periodo Preoperatorio , SARS-CoV-2 , Encuestas y Cuestionarios , Flujo de Trabajo
2.
BMC Anesthesiol ; 18(1): 3, 2018 01 05.
Artículo en Inglés | MEDLINE | ID: mdl-29304735

RESUMEN

BACKGROUND: Ambulatory surgery has recently gain popularity, as it is a good method of optimizinghospital resources utilization. To support ambulatory surgery, anaesthetic goals nowrevolve around patients' early recovery with minimal pain and nausea, expedientdischarge home and prompt resumption of activities of daily living. In this study, weevaluated the effect of a single pre-induction dose of dexmedetomidine on anaestheticrequirements, postoperative pain and clinical recovery after ambulatory ureteroscopy andureteric stenting under general anaesthesia. METHODS: Sixty patients were randomised to receive IV dexmedetomidine 0.5 µg.kg-1 (Group DEX, n = 30) or IV saline (Group P, n = 30). General anaesthesia was maintained with Sevoflurane: oxygen: air, titrated to BIS 40-60. Pain intensity, sedation, rescue analgesics, nausea/vomiting and resumption of daily activities were recorded at 1 h, and postoperative day (POD) 1-5. RESULTS: Group DEX patients had significant reduction in sevoflurane minimum alveolar concentration (MAC), mean (SD) DEX vs. Placebo 0.6 (0.2) vs. 0.9 (0.1), p = 0.037; reduced postoperative resting pain at 1 h (VAS 0-10) (mean (SD) 1.00 (1.84) vs. 2.63 (2.78), p = 0.004), POD 1 (mean (SD) 1.50 (1.48) vs. 2.87 (2.72), p = 0.002), POD 2 (0.53 (0.97) vs. 1.73 (1.96), p = 0.001) and POD 3 (0.30 (0.75) vs. 0.89 (1.49), p = 0.001). DEX patients also had less pain on movement POD 1 (3.00 (2.12) vs. 4.30 (3.10), p = 0.043) and POD 2 (2.10 (1.98) vs. 3.10 (2.46), p = 0.040), with higher resumption of daily activities by 48 h compared to placebo, 87% vs. 63%, p = 0.04. CONCLUSIONS: We conclude that a single dose of dexmedetomidine was a useful adjuvant in reducing MAC and postoperative pain (at 1 h and POD 1-3), facilitating faster return to daily activities by 48 h. TRIAL REGISTRATION: The Australian New Zealand Clinical Trials Registry (ANZCTR), ACTRN12617001120369 , 31st July 2017, retrospectively registered.


Asunto(s)
Procedimientos Quirúrgicos Ambulatorios/métodos , Dexmedetomidina/administración & dosificación , Dexmedetomidina/farmacología , Dolor Postoperatorio/prevención & control , Náusea y Vómito Posoperatorios/prevención & control , Uréter/cirugía , Ureteroscopía/efectos adversos , Ureteroscopía/métodos , Actividades Cotidianas , Administración Intravenosa , Adolescente , Adulto , Anciano , Analgésicos no Narcóticos/administración & dosificación , Analgésicos no Narcóticos/farmacología , Método Doble Ciego , Femenino , Humanos , Masculino , Persona de Mediana Edad , Stents , Adulto Joven
3.
Anaesth Intensive Care ; 45(2): 244-250, 2017 03.
Artículo en Inglés | MEDLINE | ID: mdl-28267947

RESUMEN

Newer second generation supraglottic airway devices may perform differently in vivo due to material and design modifications. We compared performance characteristics of the Ambu® AuraGain™ and LMA Supreme™ Second Seal™ in 100 spontaneously breathing anaesthetised patients in this randomised controlled study. We studied oropharyngeal leak pressures (OLP) (primary outcome) and secondarily, ease of insertion, success rates, haemodynamic response, time to insertion, and complications of usage. We found no significant difference in OLP between the AuraGain versus the LMA Supreme, mean (standard deviation, SD) 24.1 (7.4) versus 23.6 (6.2) cmH2O, P=0.720. First-attempt placement rates of the AuraGain were comparable to the LMA Supreme, 43/50 (86%) versus 39/50 (78%), P=0.906, with an overall 98% insertion success rate for the AuraGain and 88% for the LMA Supreme after three attempts, P=0.112. However, the AuraGain was deemed subjectively harder to insert, with only 24/50 (48%) versus 37/50 (74%) of AuraGain insertions being scored 1 = easy (on a 5 point scale), P=0.013, and also took longer to insert, 33.4 (SD 10.9) versus 27.3 (SD 11.4) seconds, P=0.010. The AuraGain needed a smaller volume of air (16.4 [SD 6.8] versus 23.0 [SD 7.4] ml, P <0.001) to attain intracuff pressures of 60 cmH2O, facilitated more successful gastric tube insertion (100% versus 90.9%, P=0.046), and had significantly decreased sore throat incidence (10% versus 38%, P=0.020). One AuraGain and six LMA Supremes failed to be placed within the stipulated 120 seconds trial definition of 'success'; these patients had risk factors for failed supraglottic insertion. In conclusion, both devices had similar OLPs and performed satisfactorily. However, the AuraGain resulted in less postoperative sore throat despite being harder to and taking longer to, insert.


Asunto(s)
Manejo de la Vía Aérea/instrumentación , Máscaras Laríngeas , Respiración , Adulto , Anciano , Manejo de la Vía Aérea/efectos adversos , Femenino , Humanos , Máscaras Laríngeas/efectos adversos , Masculino , Persona de Mediana Edad , Faringitis/prevención & control , Faringe , Presión
4.
Anaesthesia ; 67(11): 1210-6, 2012 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-22950484

RESUMEN

We compared sedation levels in children following administration of intranasal dexmedetomidine. One hundred and sixteen children aged between 1 and 8 years were enrolled in this prospective, randomised trial. Children were assigned to receive either intranasal dexmedetomidine 1 µg.kg(-1) (Group 1) or 2 µg.kg(-1) (Group 2). Thirty-one (53%) patients from Group 1 and 38 (66%) patients from Group 2 were satisfactorily sedated at the time of anaesthetic induction. Logistic regression showed a significant interaction effect (p=0.049), with the odds ratio between Group 2 over Group 1 estimated as 1.1 (95% CI 0.5-2.7) for the 1-4 year age group, and 10.5 (95% CI 1.4-80.2) for the 5-8 year age group. Both doses produced a similar level of satisfactory sedation in children aged 1-4 years, whereas 2 µg.kg(-1) resulted in a higher proportion of satisfactory sedation in children aged 5-8 years. There were no adverse haemodynamic effects. We conclude that intranasal dexmedetomidine in a premedication dose of 2 µg.kg(-1) resulted in excellent sedation in children.


Asunto(s)
Dexmedetomidina/administración & dosificación , Dexmedetomidina/farmacología , Hipnóticos y Sedantes/administración & dosificación , Hipnóticos y Sedantes/farmacología , Medicación Preanestésica , Administración Intranasal , Conducta , Niño , Preescolar , Relación Dosis-Respuesta a Droga , Método Doble Ciego , Femenino , Hemodinámica/efectos de los fármacos , Humanos , Lactante , Modelos Logísticos , Masculino , Estudios Prospectivos
5.
Anaesthesia ; 63(1): 82-5, 2008 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-18086075

RESUMEN

We compared the performance of the Ambu AuraOnce Laryngeal Mask with that of the LMA Classic laryngeal mask airway during controlled anaesthesia. Forty patients requiring intermittent positive pressure ventilation were studied using a randomised crossover design. The mean (SD) oropharyngeal leak pressure for the Ambu device (19 (7.5) cmH2O) was significantly greater than for the LMA Classic (15 (5.2) cmH2O; p = 0.004), and the number of attempts for successful insertions was significantly less (39 (50%) vs 45 (56%), respectively; p = 0.02). There was one failure to obtain a patent airway with the Ambu Laryngeal Mask and none with the LMA Classic. Insertion of the Ambu Laryngeal Mask required more manipulations to achieve a patent airway than did the LMA Classic (6 (15%) vs 1 (2.5%), respectively; p = 0.045), but the time taken for insertion was similar between the two groups. The incidence of trauma, grade of fibreoptic view, peak airway pressure and quality of ventilation during maintenance of anaesthesia were similar in both groups.


Asunto(s)
Anestesia General/métodos , Máscaras Laríngeas , Adolescente , Adulto , Anciano , Estudios Cruzados , Equipos Desechables , Equipo Reutilizado , Femenino , Humanos , Ventilación con Presión Positiva Intermitente , Intubación Intratraqueal/instrumentación , Intubación Intratraqueal/métodos , Masculino , Persona de Mediana Edad , Factores de Tiempo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...