Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 82
Filtrar
1.
Indian J Radiol Imaging ; 30(3): 253-262, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-33273757

RESUMEN

BACKGROUND: Sacro-pelvic morphology and orientation are usually described in terms of pelvic incidence (PI), pelvic tilt (PT), and sacral slope (SS). Orientation and morphology of pelvis can affect degenerative changes in the lumbar spine. Thus, here we investigated the relationships between various sagittal spinopelvic parameters and the degree of disc degeneration in young adults. MATERIAL AND METHODS: A hospital-based cross-sectional study with a total of 60 cases was done. Patients presenting with back or leg pain having prolapsed disc on magnetic resonance imaging (MRI) were included in the study. A standing X-ray of LS spine from dorso-lumbar junction to mid-thigh was taken. Various spinopelvic parameters were assessed from the scannogram using the software. RESULTS: The mean age was 39.27 years. L5S1 was the most common level. Mean SS, PT, PI, and LL were 37.78°, 13.52°, 51.33°, and 41.01°. Disc pathologies at L1L2, L2L3, and L4L5 level showed a positive correlation with PT, PI, and LL. Disc pathology at the L5S1 level shows a positive correlation with PT and LL. A statistically significant correlation between SS and degenerative spondylolisthesis at L4L5 was found from data with P = 0.023. DISCUSSION: An increase in SS statistically significantly increases the chance of development of degenerative spondylolisthesis at L4L5. An increase in PT, PI, and LL will cause an increase in disc pathology at L1L2. An increase in SS, PT, PI, and LL will cause an increase in disc pathology at L2L3. An increase in SS, PT, PI, and LL will cause an increase in disc pathology at L4L5. An increase in PT and LL will cause an increase in disc pathology at L5S1. CONCLUSION: Standing lateral view radiograph from dorso-lumbar junction to the mid-thigh is as good as standing whole spine radiograph for measurement of spinopelvic parameters. Degenerative spondylolisthesis at L4L5 has a statistically significant correlation with an increase in SS.

2.
Infect Genet Evol ; 54: 47-53, 2017 10.
Artículo en Inglés | MEDLINE | ID: mdl-28625543

RESUMEN

Vibrio cholerae O1 is the etiological agent of the severe diarrheal disease cholera. The bacterium has recently been causing outbreaks in Haiti with catastrophic effects. Numerous mutations have been reported in V. cholerae O1 strains associated with the Haitian outbreak. These mutations encompass among other the genes encoding virulence factors such as the pilin subunit of the toxin-co-regulated pilus (tcpA), cholera toxin B subunit (ctxB), repeat in toxins (rtxA), and other genes such as the quinolone resistance-determining region (QRDR) of gyrase A (gyrA), rstB of RS element along with the alteration in the number of repeat sequences at the promoter region of ctxAB. Given the numerous genetic changes in those Haitian isolates, we decided to investigate the possible origins of those variations in the Indian subcontinent. Thus, we determined the genetic traits among V. cholerae O1 strains in Delhi, India. A total of 175 strains isolated from cholera patients during 2004 to 2012 were analysed in the present study. Our results showed that all the tested strains carried Haitian type tcpA (tcpACIRS) and variant gyrA indicating their first appearance before 2004 in Delhi. The Haitian variant rtxA and ctxB7 were first detected in Delhi during 2004 and 2006, respectively. Interestingly, not a single strain with the combination of El Tor rtxA and ctxB7 was detected in this study. The Delhi strains carried four heptad repeats (TTTTGAT) in the CT promoter region whereas Haitian strains carried 5 such repeats. Delhi strains did not have any deletion mutations in the rstB like Haitian strains. Overall, our study demonstrates the sequential accumulation of Haitian-like genetic traits among V. cholerae O1 strains in Delhi at different time points prior to the Haitian cholera outbreak.


Asunto(s)
Cólera/microbiología , Genes Bacterianos/genética , Vibrio cholerae O1/genética , Cólera/epidemiología , Haití/epidemiología , Humanos , Epidemiología Molecular , Regiones Promotoras Genéticas/genética
3.
Plant Physiol Biochem ; 110: 59-69, 2017 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-27622846

RESUMEN

The present study describes the role of zinc oxide nanoparticles (ZnONPs) in reversing oxidative stress symptoms induced by heavy metal (Cd and Pb) exposure in Leucaena leucocephala (Lam.) de Wit. Seedling growth was significantly enhanced with the augmentation of ZnONPs following Cd and Pb exposure. Heavy metal accumulations were recorded as 1253.1 mg Cd per kg DW and 1026.8 mg Pb per kg DW for the respective treatments. Results demonstrated that ZnONPs augmentation caused an increase in photosynthetic pigment and total soluble protein contents while a significant decrease in malondialdehyde (MDA-lipid peroxidation) content in leaves. Antioxidative enzymes such as superoxide dismutase (SOD), catalase (CAT) and peroxidase (POX) were, in turn, elevated in heavy metal-exposed leaves amended with ZnONPs. The ameliorating effect of ZnO nanoparticles on oxidative stress induced toxicity was also confirmed by the reduced MDA content and the elevated level of antioxidative enzyme activities in leaf tissues of L. leucocephala seedlings. Further, addition of ZnONPs in combination with Cd and Pb metals induced distinct genomic alterations such as presence of new DNA bands and/or absence of normal bands in the RAPD pattern of the exposed plants. This study uniquely suggests a potential role of zinc oxide nanoparticles in the remediation of heavy metal contaminated media.


Asunto(s)
Fabaceae/efectos de los fármacos , Nanopartículas del Metal/administración & dosificación , Metales Pesados/toxicidad , Plantones/efectos de los fármacos , Óxido de Zinc/química , Antioxidantes/administración & dosificación , Antioxidantes/química , Antioxidantes/farmacología , Cadmio/metabolismo , Cadmio/toxicidad , Carotenoides/metabolismo , Catalasa/metabolismo , Clorofila/metabolismo , ADN de Plantas/genética , ADN de Plantas/metabolismo , Fabaceae/crecimiento & desarrollo , Fabaceae/metabolismo , Plomo/metabolismo , Plomo/toxicidad , Malondialdehído/metabolismo , Nanopartículas del Metal/química , Metales Pesados/metabolismo , Estrés Oxidativo/efectos de los fármacos , Peroxidasa/metabolismo , Fotosíntesis/efectos de los fármacos , Hojas de la Planta/efectos de los fármacos , Hojas de la Planta/crecimiento & desarrollo , Hojas de la Planta/metabolismo , Proteínas de Plantas/metabolismo , Técnica del ADN Polimorfo Amplificado Aleatorio , Plantones/crecimiento & desarrollo , Plantones/metabolismo , Superóxido Dismutasa/metabolismo
4.
Curr Oncol ; 22(4): e237-45, 2015 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-26300673

RESUMEN

BACKGROUND: Advance care planning (acp) is an important process in health care today. How to prospectively identify potential local barriers and facilitators to uptake of acp across a complex, multi-sector, publicly funded health care system and how to develop specific mitigating strategies have not been well characterized. METHODS: We surveyed a convenience sample of clinical and administrative health care opinion leaders across the province of Alberta to characterize system-specific barriers and facilitators to uptake of acp. The survey was based on published literature about the barriers to and facilitators of acp and on the Michie Theoretical Domains Framework. RESULTS: Of 88 surveys, 51 (58%) were returned. The survey identified system-specific barriers that could challenge uptake of acp. The factors were categorized into four main domains. Three examples of individual system-specific barriers were "insufficient public engagement and misunderstanding," "conflict among different provincial health service initiatives," and "lack of infrastructure." Local system-specific barriers and facilitators were subsequently explored through a semi-structured informal discussion group involving key informants. The group identified approaches to mitigate specific barriers. CONCLUSIONS: Uptake of acp is a priority for many health care systems, but bringing about change in multi-sector health care systems is complex. Identifying system-specific barriers and facilitators to the uptake of innovation are important elements of successful knowledge translation. We developed and successfully used a simple and inexpensive process to identify local system-specific barriers and enablers to uptake of acp, and to identify specific mitigating strategies.

5.
J Clin Dent ; 23(3): 80-5, 2012.
Artículo en Inglés | MEDLINE | ID: mdl-23210418

RESUMEN

OBJECTIVE: The purpose of this study was to evaluate the anti-gingivitis effectiveness of a 0.454% stannous fluoride test dentifrice relative to a marketed positive-control triclosan-containing dentifrice in adults with gingivitis. METHODS: This was a two-month, randomized and controlled, double-blind, parallel group, single-center investigation involving 150 adults with existing mild to moderate gingivitis. Pre-treatment gingivitis levels were assessed at baseline using the Lobene Modified Gingival Index (MGI) and the Gingival Bleeding Index (GBI). Qualified subjects were randomly assigned to either a 0.454% stannous fluoride test dentifrice or a marketed, positive-control 0.30% triclosan/copolymer dentifrice. Subjects then brushed for two months unsupervised in the home setting with their assigned dentifrice per manufacturer's instructions. At Month 2, subjects were re-evaluated for gingivitis via MGI and GBI examinations. RESULTS: All 150 enrolled subjects completed the trial and were evaluable. Both the stannous fluoride test and triclosan/copolymer control dentifrices provided statistically significant reductions in average MGI, GBI, and number of bleeding sites relative to pre-treatment (p < 0.0001) at Month 2. The adjusted mean improvement from baseline at Month 2 for the stannous fluoride test dentifrice group was 65% greater for number of bleeding sites, 62% greater for GBI, and 45% greater for MGI compared to the triclosan/copolymer positive-control group, with groups differing significantly (p < 0.0001) via each of the three gingivitis measures. Both dentifrices were well-tolerated. CONCLUSION: An advanced stannous fluoride test dentifrice provided superior reductions in gingival inflammation and gingival bleeding compared to a commercially available triclosan/copolymer positive-control dentifrice after two months of tooth brushing.


Asunto(s)
Dentífricos/uso terapéutico , Gingivitis/prevención & control , Fosfatos/uso terapéutico , Fluoruros de Estaño/uso terapéutico , Adolescente , Adulto , Anciano , Análisis de Varianza , Dentífricos/química , Método Doble Ciego , Combinación de Medicamentos , Femenino , Humanos , Masculino , Maleatos/uso terapéutico , Persona de Mediana Edad , Índice Periodontal , Polivinilos/uso terapéutico , Estudios Prospectivos , Ácido Silícico/uso terapéutico , Pastas de Dientes/uso terapéutico , Triclosán/uso terapéutico , Adulto Joven
6.
J Clin Dent ; 22(1): 19-22, 2011.
Artículo en Inglés | MEDLINE | ID: mdl-21290982

RESUMEN

OBJECTIVE: To assess the plaque removal efficacy of an oscillating/rotating power toothbrush with novel brush head (Oral-B Precision Clean) in comparison to an American Dental Association (ADA) reference manual toothbrush. METHODS: This was a replicate-use, single-brushing, two-treatment, examiner-blind, randomized, four-period (visit) study with a crossover design. At each visit, subjects disclosed their plaque with disclosing solution for one minute, and an examiner performed a baseline (pre-brushing) plaque examination (Rustogi, et al. Modification of the Navy Plaque Index). Subjects were then instructed to brush for two minutes (according to manufacturer's instructions) with their assigned power toothbrush or as they normally do with the ADA manual brush under supervision, after which they again disclosed their plaque and were given a post-brushing plaque examination. RESULTS: Both the power brush and manual brush showed statistically significant plaque reductions from baseline for the whole mouth, along the gingival margin, and on approximal surfaces. The power brush showed statistically significant advantages (p < 0.001) over the manual brush in plaque reduction for whole mouth (28.8%), gingival margin (44.3%), and approximal surfaces (20.7%). CONCLUSION: The oscillating/rotating power toothbrush with a novel brush head showed statistically significantly superior plaque reduction (whole mouth, gingival margin, and approximal surfaces) compared to a manual toothbrush.


Asunto(s)
Placa Dental/terapia , Cepillado Dental/instrumentación , Adulto , Anciano , Colorantes , Estudios Cruzados , Dispositivos para el Autocuidado Bucal , Placa Dental/diagnóstico , Índice de Placa Dental , Equipos y Suministros Eléctricos , Diseño de Equipo , Femenino , Encía/patología , Humanos , Masculino , Persona de Mediana Edad , Método Simple Ciego , Corona del Diente/patología , Adulto Joven
7.
J Clin Dent ; 21(1): 8-12, 2010.
Artículo en Inglés | MEDLINE | ID: mdl-20527506

RESUMEN

OBJECTIVE: To assess and compare the plaque removal efficacy of five different Oral-B manual toothbrushes: CrossAction Pro-Health (CAPH), CrossAction (CA), Exceed (EX), Advantage 123 (ADV 123), and Indicator (IND). METHODS: This was a single-use, five-treatment, examiner-blind, randomized, five-period (visit) crossover study, with 10 different treatment sequences (groups) that determined the order in which the five toothbrushes were assigned at study visits. Three toothbrushes had an advanced CrissCross bristle design (CAPH, CA, EX), while two had more standard designs with straight bristles (ADV 123 and IND). At the first visit, subjects disclosed their plaque with disclosing solution, and an examiner performed a baseline plaque examination using the Rustogi, et al. Modification of the Navy Plaque Index (RMNPI). Subjects brushed for one minute with their assigned toothbrush under supervision, after which they again disclosed their plaque and were given a second plaque examination. The same procedure was followed for each of the visits in turn. RESULTS: All five manual toothbrushes showed a statistically significant (p < 0.0001) reduction in plaque from baseline for the whole mouth (84% to 93%), gingival margin (74% to 88%), and approximal surfaces (95% to 99%). For pair-wise treatment comparisons for all three plaque measures, CAPH, CA, and EX demonstrated statistically significantly better plaque removal than ADV 123 and IND (all p < 0.018). No other treatment comparisons were statistically significant. CONCLUSION: All five manual toothbrushes showed highly effective plaque reduction for whole mouth, gingival margin, and approximal surfaces. Comparisons between brushes showed consistent advantages for CAPH, CA, and EX compared to ADV 123 and IND for all three plaque measures, indicating that advances in toothbrush design can further enhance plaque removal.


Asunto(s)
Placa Dental/prevención & control , Cepillado Dental/instrumentación , Adolescente , Adulto , Anciano , Estudios Cruzados , Índice de Placa Dental , Diseño de Equipo , Eritrosina , Femenino , Colorantes Fluorescentes , Encía/patología , Humanos , Masculino , Persona de Mediana Edad , Método Simple Ciego , Diente/patología , Resultado del Tratamiento , Adulto Joven
8.
Indian J Radiol Imaging ; 19(2): 148-50, 2009.
Artículo en Inglés | MEDLINE | ID: mdl-19881072

RESUMEN

A 30-year-old man presented with a fairly large intramedullary mass lesion involving virtually the entire spinal cord. It was hyperintense on both T1W and T2W sequences, with signal suppression on fat-saturation images. Subsequent noncontrast CT scan of the spine confirmed the presence of fat and calcification within the lesion, thus leading to the diagnosis of an intramedullary dermoid.

9.
Indian J Med Res ; 125(5): 633-40, 2007 May.
Artículo en Inglés | MEDLINE | ID: mdl-17642498

RESUMEN

BACKGROUND & OBJECTIVE: Cholera caused by either Vibrio cholerae O1 or O139 is endemic in Delhi and its peripheral areas. The present study was carried out to understand the changing epidemiology of V. cholerae in terms of prevalence of serotypes, antibiogram pattern and phage types. METHODS: A total of 9858 stool samples from the admitted diarrhoea patients were used for the isolation of V. cholerae O1 and O139. Subsets of isolates were tested against thirteen antimicrobials and phage typed. RESULTS: Among 4251 (43.1%) confirmed cases, 41.6 per cent were V. cholerae O1 and rest (1.5 %) V. cholerae O139. Detection of V. cholerae O1 serotype Inaba was 87.7 per cent during 2005 and rest were serotype Ogawa. Majority of cases (93.1%) were from Delhi. Male:Female ratio remained 1.5:1.0. Children below 5 yr age group constituted 32.7 per cent cases. Shift in the age groups and seasonal incidence were recorded. All 226 strains of V. cholerae O1 and O139 were resistant to nalidixic acid; 96 per cent V. cholerae O1 isolates were multidrug resistant (FX NA SXT). Phage type 27 (98.7%) was the most prevalent and the new phage types were 4, 16 and 25 in this area. INTERPRETATION & CONCLUSION: Enhanced surveillance helped in bringing down cases from 47.7 per cent in 2003 to 36.8 per cent in 2005. Additionally, the changing epidemiology of V. cholerae O1 and O139 infections and drug resistance need regular monitoring.


Asunto(s)
Cólera/epidemiología , Vibrio cholerae O1/aislamiento & purificación , Adolescente , Adulto , Anciano , Niño , Preescolar , Cólera/microbiología , Femenino , Humanos , India/epidemiología , Lactante , Recién Nacido , Masculino , Persona de Mediana Edad , Factores de Tiempo
10.
Appl Opt ; 46(15): 2922-9, 2007 May 20.
Artículo en Inglés | MEDLINE | ID: mdl-17514239

RESUMEN

Atmospheric aerosols have been profiled using a simple, imaging, bistatic lidar system. A vertical laser beam is imaged onto a charge-coupled-device camera from the ground to the zenith with a wide-angle lens (CLidar). The altitudes are derived geometrically from the position of the camera and laser with submeter resolution near the ground. The system requires no overlap correction needed in monostatic lidar systems and needs a much smaller dynamic range. Nighttime measurements of both molecular and aerosol scattering were made at Mauna Loa Observatory. The CLidar aerosol total scatter compares very well with a nephelometer measuring at 10 m above the ground. The results build on earlier work that compared purely molecular scattered light to theory, and detail instrument improvements.

11.
Indian J Med Res ; 126(6): 545-52, 2007 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-18219082

RESUMEN

BACKGROUND & OBJECTIVE: Diphtheria infections caused by the different toxigenic biotypes of Corynebacterium diphtheriae are endemic in Delhi. Information on biochemical identification, toxigenicity and antimicrobial susceptibility to this bacterium is scanty. This retrospective study was carried out to identify isolated Corynebacteria biochemically, determine their toxigenicity, drug sensitivity and some epidemiological characteristics of diphtheria cases from Delhi and adjoining States for the period 1998-2004. METHODS: A total of 1118 throat and 585 nasal swabs were used to detect human pathogenic corynebacteria. WHO recommended methods were used for the detection, screening, toxigenicity and antibiogram pattern of the isolates. RESULTS: Among 493 (44.1%) cases detected positive for corynebacteria 71.8 per cent were pharyngeal, 20.9 per cent nasopharyngeal and rest 7.3 per cent nasal diphtheria cases. Biochemical identification revealed two species i.e., C. diphtheriae and C. pseudodiphtheriticum. In C. diphtheriae three biotypes were detected viz., intermedius (95.5%), gravis (3.4%) and mitis (1.1%). Toxin was expressed by 96 per cent isolates of C. diphtheriae. Cases were recorded from Delhi and four adjoining States. Sex ratio among male to female was 1.6:1. Prime victims were less than 9 yr old children (93.3%). Unvaccinated children (70.2%) were the main sufferers. Fatality rate was highest in Delhi cases (16.8%) followed by UP (14.6%) and Haryana (5.9%). INTERPRETATION & CONCLUSION: Standard methods revealed the replacement of C. diphtheriae var mitis with var intermedius and occurrence of diphtheria infections due to other human pathogenic corynebacteria. It is imperative to have good bacteriological facilities to have better surveillance with regular monitoring in the endemic areas to keep the disease under control.


Asunto(s)
Difteria/epidemiología , Difteria/microbiología , Niño , Preescolar , Corynebacterium/clasificación , Corynebacterium/aislamiento & purificación , Corynebacterium/patogenicidad , Corynebacterium diphtheriae/clasificación , Corynebacterium diphtheriae/aislamiento & purificación , Corynebacterium diphtheriae/patogenicidad , Difteria/prevención & control , Femenino , Humanos , India/epidemiología , Lactante , Masculino , Estudios Retrospectivos , Estaciones del Año
12.
J Clin Microbiol ; 44(9): 3391-3, 2006 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-16954282

RESUMEN

During 2004 and 2005, cholera was recorded in 15 states of India, with 7 outbreaks. The newly emerged Vibrio cholerae O1 Inaba had a different antibiogram and ribotype, different pulsotypes, and different mutations in the wbeT gene. Due to the absence of serogroup O139, the Inaba serotype may have acquired the potential to affect the population at large.


Asunto(s)
Cólera/transmisión , Brotes de Enfermedades , Vibrio cholerae O1/clasificación , Vibrio cholerae O1/genética , Antibacterianos/farmacología , Proteínas Bacterianas/genética , Cólera/epidemiología , Cólera/microbiología , Humanos , India/epidemiología , Pruebas de Sensibilidad Microbiana , Datos de Secuencia Molecular , Ribotipificación , Análisis de Secuencia de ADN , Serotipificación , Vibrio cholerae O1/efectos de los fármacos
13.
J Dent ; 33S1: 11-15, 2005 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-16253750

RESUMEN

OBJECTIVES.: To compare the safety and plaque removal efficacy of two oscillating/rotating/pulsating toothbrushes (Oral-B ProfessionalCaretrade mark 7000 [PC 7000] and Oral-B 3D Excel [3DE]) and a high-frequency toothbrush (Sonicare(R) Advance, Philips Oral Healthcare; SA) in a single-use, examiner-blind, three period crossover study. METHODS.: After refraining from all oral hygiene procedures for 23-25 hours, subjects received an oral tissue examination and those with pre-brushing whole mouth mean plaque scores 0.6 based on the Rustogi et al. Modified Navy Plaque Index were randomly assigned to treatment sequence. After brushing with the assigned toothbrush and a commercially available dentifrice for 2 minutes, oral tissues were then re-examined and post-brushing plaque scores recorded. Following a brief washout period between two additional visits, the above procedures were repeated with the two alternate toothbrushes. One examiner, blinded to the treatment sequence, performed all clinical measurements. RESULTS.: A total of 79 subjects (28 males and 51 females) were enrolled and completed the study. Each toothbrush was found to be safe and significantly reduced plaque levels after a single brushing. The PC 7000 and 3DE were equally more effective in plaque removal than the SA, at all tooth areas, reducing plaque by 59.0%, 59.7% and 51.8%, respectively on whole mouth surfaces, and by 67.5%, 67.8% and 59.4%, respectively on approximal surfaces. CONCLUSIONS.: The action of the oscillating/rotating/pulsating toothbrushes (Oral-B ProfessionalCare 7000 and Oral-B 3D Excel) was more effective in plaque removal than the high-frequency toothbrush (Sonicare Advance).

14.
J Dent ; 33S1: 17-21, 2005 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-16253751

RESUMEN

OBJECTIVES.: To compare the safety and plaque removal efficacy of two electric toothbrushes, one a rechargeable oscillating/pulsating toothbrush with a small round brush head (Oral-B ProfessionalCaretrade mark 7000; PC 7000), the other a battery-operated toothbrush with a dual moving brush head (Crest(R) SpinBrushtrade mark Pro; SBP). METHODS.: The study had a randomised, examiner-blind, two-arm crossover design. All subjects received an oral prophylaxis and used both toothbrushes on alternating days for a two-week practice period. After abstaining from all oral hygiene procedures for 23-25 hours, subjects received an oral tissue examination and those with pre-brushing whole mouth mean plaque scores >/=0.60 measured by the Rustogi et al. Modified Navy Plaque Index were randomly assigned to treatment sequence. Subjects brushed with their assigned toothbrush for 2 minutes using a commercially available dentifrice. Oral tissues were then re-examined and post-brushing plaque scores recorded. After a brief washout period, the above procedures were repeated with the alternate toothbrush. One examiner, blinded to the treatment sequence, performed all clinical measurements. RESULTS.: A total of 70 subjects (24 males and 46 females) were enrolled and completed the study. Each toothbrush was found to be safe and significantly reduced plaque levels after a single brushing. The PC 7000 was significantly more effective in plaque removal than the SBP at all tooth areas, reducing whole mouth plaque by 61% versus 58% and plaque from approximal surfaces by 69% versus 65%, respectively. CONCLUSIONS.: The action of the oscillating/pulsating toothbrush with a small round brush head, Oral-B ProfessionalCare 7000, is more effective in plaque removal than the battery-operated Crest SpinBrush Pro toothbrush with a larger dual moving brush head.

15.
J Dent ; 33S1: 37-43, 2005 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-16253754

RESUMEN

OBJECTIVES.: To compare the safety and efficacy of an oscillating/pulsating power toothbrush (Oral-B ProfessionalCaretrade mark 7000; PC 7000) fitted with either the standard FlexiSoft (PC 7000/EB17) brush head or the novel Pro Polisher (PC 7000/EB-Prophy) and a high-frequency toothbrush (Philips Sonicare(R) Elite(R); SE), in their relative ability to remove plaque and naturally occurring extrinsic dental stain over a six-week period. METHODS.: This randomised, examiner-blind, parallel group study involved 90 healthy subjects from a general population. All subjects received a baseline plaque (Turesky et al. modified Quigley-Hein Plaque Index), stain (Lobene Stain Index) and tooth shade (VITAPAN(R) Shade Guide) [Vita] assessment and an oral tissue examination. After training in the use of their randomly assigned device, subjects were instructed to brush twice daily for 2 min and returned after 3, 4 and 6 weeks of product use for a repeat of each clinical assessment. RESULTS.: Reductions from baseline in mean plaque and extrinsic dental stain scores were significant at Weeks 3, 4 and 6 in all three treatment groups. By Week 6, mean reductions from baseline in whole mouth plaque scores were 32%, 27% and 14% in the PC 7000/EB-Prophy, PC 7000/EB17 and SE groups, respectively. For the body of the tooth, mean reductions from baseline at Week 6 in total stain were 89%, 89% and 80%, respectively. Between treatment group comparisons consistently revealed that the PC 7000 toothbrush plus the EB-Prophy or EB17 brush head removed significantly more plaque and extrinsic stain (total stain, stain area and stain intensity) than the SE toothbrush at 3, 4 and 6 weeks. The EB-Prophy group had a greater proportion of subjects showing a 2-3+ change in Vita shade scores at each time point compared to the other two brushes; at Week 6 the proportions were 67% in the PC 7000/EB-Prophy group, 30% in the PC 7000/EB17 group, and 7% in the SE group. The PC 7000/EB17, PC 7000/EB-Prophy and the SE were found to be safe as used in the study. CONCLUSIONS.: The oscillating/rotating/pulsating PC 7000 (fitted with either the standard EB17 or novel EB-Prophy brush head) is more effective at removal of plaque and naturally occurring extrinsic tooth stain, and the PC 7000 plus EB-Prophy in the improvement of tooth shade, than the high-frequency SE toothbrush.

16.
J Dent ; 33 Suppl 1: 11-5, 2005 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-16208798

RESUMEN

OBJECTIVES: To compare the safety and plaque removal efficacy of two oscillating/rotating/pulsating toothbrushes (Oral-B ProfessionalCare 7000 [PC 7000] and Oral-B 3D Excel [3DE]) and a high-frequency toothbrush (Sonicare Advance, Philips Oral Healthcare; SA) in a single-use, examiner-blind, three period crossover study. METHODS: After refraining from all oral hygiene procedures for 23-25 hours, subjects received an oral tissue examination and those with pre-brushing whole mouth mean plaque scores > or = 0.6 based on the Rustogi et al. Modified Navy Plaque Index were randomly assigned to treatment sequence. After brushing with the assigned toothbrush and a commercially available dentifrice for 2 minutes, oral tissues were then re-examined and post-brushing plaque scores recorded. Following a brief washout period between two additional visits, the above procedures were repeated with the two alternate toothbrushes. One examiner, blinded to the treatment sequence, performed all clinical measurements. RESULTS: A total of 79 subjects (28 males and 51 females) were enrolled and completed the study. Each toothbrush was found to be safe and significantly reduced plaque levels after a single brushing. The PC 7000 and 3DE were equally more effective in plaque removal than the SA, at all tooth areas, reducing plaque by 59.0%, 59.7% and 51.8%, respectively on whole mouth surfaces, and by 67.5%, 67.8% and 59.4%, respectively on approximal surfaces. CONCLUSIONS: The action of the oscillating/rotating/pulsating toothbrushes (Oral-B ProfessionalCare 7000 and Oral-B 3D Excel) was more effective in plaque removal than the high-frequency toothbrush (Sonicare Advance).


Asunto(s)
Placa Dental/terapia , Cepillado Dental/instrumentación , Adolescente , Adulto , Electricidad , Métodos Epidemiológicos , Diseño de Equipo , Femenino , Humanos , Masculino , Persona de Mediana Edad , Rotación
17.
J Dent ; 33 Suppl 1: 17-21, 2005 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-16208799

RESUMEN

OBJECTIVES: To compare the safety and plaque removal efficacy of two electric toothbrushes, one a rechargeable oscillating/pulsating toothbrush with a small round brush head (Oral-B ProfessionalCare 7000; PC 7000), the other a battery-operated toothbrush with a dual moving brush head (Crest SpinBrush Pro; SBP). METHODS: The study had a randomised, examiner-blind, two-arm crossover design. All subjects received an oral prophylaxis and used both toothbrushes on alternating days for a two-week practice period. After abstaining from all oral hygiene procedures for 23-25 hours, subjects received an oral tissue examination and those with pre-brushing whole mouth mean plaque scores > or = 0.60 measured by the Rustogi et al. Modified Navy Plaque Index were randomly assigned to treatment sequence. Subjects brushed with their assigned toothbrush for 2 minutes using a commercially available dentifrice. Oral tissues were then re-examined and post-brushing plaque scores recorded. After a brief washout period, the above procedures were repeated with the alternate toothbrush. One examiner, blinded to the treatment sequence, performed all clinical measurements. RESULTS: A total of 70 subjects (24 males and 46 females) were enrolled and completed the study. Each toothbrush was found to be safe and significantly reduced plaque levels after a single brushing. The PC 7000 was significantly more effective in plaque removal than the SBP at all tooth areas, reducing whole mouth plaque by 61% versus 58% and plaque from approximal surfaces by 69% versus 65%, respectively. CONCLUSIONS: The action of the oscillating/pulsating toothbrush with a small round brush head, Oral-B ProfessionalCare 7000, is more effective in plaque removal than the battery-operated Crest SpinBrush Pro toothbrush with a larger dual moving brush head.


Asunto(s)
Placa Dental/terapia , Cepillado Dental/instrumentación , Adolescente , Adulto , Anciano , Electricidad , Métodos Epidemiológicos , Diseño de Equipo , Femenino , Humanos , Masculino , Persona de Mediana Edad
18.
J Dent ; 33 Suppl 1: 37-43, 2005 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-16208802

RESUMEN

OBJECTIVES: To compare the safety and efficacy of an oscillating/pulsating power toothbrush (Oral-B ProfessionalCareTM 7000; PC 7000) fitted with either the standard FlexiSoft (PC 7000/EB17) brush head or the novel Pro Polisher (PC 7000/ EB-Prophy) and a high-frequency toothbrush (Philips Sonicare Elite; SE), in their relative ability to remove plaque and naturally occurring extrinsic dental stain over a six-week period. METHODS: This randomised, examiner-blind, parallel group study involved 90 healthy subjects from a general population. All subjects received a baseline plaque (Turesky et al. modified Quigley-Hein Plaque Index), stain (Lobene Stain Index) and tooth shade (VITAPAN Shade Guide) [Vita] assessment and an oral tissue examination. After training in the use of their randomly assigned device, subjects were instructed to brush twice daily for 2 min and returned after 3, 4 and 6 weeks of product use for a repeat of each clinical assessment. RESULTS: Reductions from baseline in mean plaque and extrinsic dental stain scores were significant at Weeks 3, 4 and 6 in all three treatment groups. By Week 6, mean reductions from baseline in whole mouth plaque scores were 32%, 27% and 14% in the PC 7000/EB-Prophy, PC 7000/EB17 and SE groups, respectivety. For the body of the tooth, mean reductions from baseline at Week 6 in total stain were 89%, 89% and 80%, respectively. Between treatment group comparisons consistently revealed that the PC 7000 toothbrush plus the EB-Prophy or EB17 brush head removed significantly more plaque and extrinsic stain (total stain, stain area and stain intensity) than the SE toothbrush at 3, 4 and 6 weeks. The EB-Prophy group had a greater proportion of subjects showing a 2-3+ change in Vita shade scores at each time point compared to the other two brushes; at Week 6 the proportions were 67% in the PC 7000/EB-Prophy group, 30% in the PC 7000/EB17 group, and 7% in the SE group. The PC 7000/EB17, PC 7000/EB-Prophy and the SE were found to be safe as used in the study. CONCLUSIONS: The oscillating/rotating/pulsating PC 7000 (fitted with either the standard EB17 or novel EB-Prophy brush head) is more effective at removal of plaque and naturally occurring extrinsic tooth stain, and the PC 7000 plus EB-Prophy in the improvement of tooth shade, than the high-frequency SE toothbrush.


Asunto(s)
Placa Dental/terapia , Decoloración de Dientes/terapia , Cepillado Dental/instrumentación , Adolescente , Adulto , Anciano , Análisis de Varianza , Índice de Placa Dental , Electricidad , Femenino , Humanos , Masculino , Persona de Mediana Edad , Método Simple Ciego
19.
Int Dent J ; 55(3): 151-6, 2005 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-15997965

RESUMEN

AIM: To compare the safety and plaque removal efficacy of an oscillating/ pulsating toothbrush (Professional Care Series, Oral-B Laboratories; PCS) and a high frequency toothbrush (Sonicare Elite, Philips Oral Healthcare; SE). METHODS: The study had a randomised, examiner-blind, crossover design. Sixty-one subjects aged 19-64 years were enrolled. After 23-25 hours of no oral hygiene, subjects received an oral tissue examination and those with pre-brushing whole mouth mean plaque scores > or = 0.60 measured by the Rustogi modified Navy Plaque Index were randomly assigned to treatment sequence. Subjects brushed with their assigned toothbrush for 2 minutes using a commercially available dentifrice. Oral tissues were then re-examined and post-brushing plaque scores recorded. After a brief washout period, the above procedures were repeated with the alternate toothbrush. One examiner blinded to the treatment sequence performed all clinical measurements. RESULTS: All 61 subjects completed the study. Both toothbrushes significantly reduced plaque levels after a single brushing (t-test, p < 0.0001). However, the PCS was significantly more effective than the SE in whole mouth plaque removal and in reducing plaque from marginal, buccal, lingual and approximal surfaces (ANOVA, p < 0.0001). Whole mouth plaque was reduced by 88% versus 61% and approximal plaque by 97% versus 73% for the PCS and SE toothbrushes, respectively. There was no evidence of hard or soft tissue trauma after a single-use of either toothbrush. CONCLUSION: Based on the findings of this single-use clinical evaluation, the action of the oscillating/ pulsating power toothbrush is more effective at plaque removal than a high frequency power toothbrush.


Asunto(s)
Cepillado Dental/instrumentación , Adulto , Estudios Cruzados , Placa Dental/patología , Placa Dental/terapia , Índice de Placa Dental , Dentífricos/uso terapéutico , Diseño de Equipo , Femenino , Humanos , Masculino , Persona de Mediana Edad , Seguridad , Método Simple Ciego , Corona del Diente/patología , Resultado del Tratamiento
20.
J Clin Periodontol ; 30(7): 590-4, 2003 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-12834495

RESUMEN

OBJECTIVE: To assess the antiplaque/antigingivitis efficacy of a hexetidine-containing mouthwash. METHODS: This examiner-blind, parallel group, controlled clinical study examined the effectiveness of a hexetidine (0.1%) mouthwash both in inhibiting the development of supragingival plaque and in reducing gingivitis. One hundred and thirty-four adult subjects completed the 2-week experimental gingivitis model study. Following baseline examinations, which included plaque index, modified gingival index and gingival bleeding index, subjects received a full dental prophylaxis. Subjects were randomly assigned to one of three mouthwashes (hexetidine 0.1%, chlorhexidine 0.12% (positive control) or a 5% hydroalcohol negative control) and commenced three times daily supervised rinsing as their sole method of oral hygiene. All indices were rescored after 2 weeks. RESULTS: Compared to the negative control group, the hexetidine group demonstrated a statistically significant inhibition and reduction of supragingival plaque and gingival inflammation with reductions of 6.3%, 33.5% and 56% for gingivitis, plaque and gingival bleeding, respectively. The results of the chlorhexidine group were used to validate the study. CONCLUSION: The study confirms the efficacy of a hexetidine rinse in reducing supragingival plaque and gingival inflammation.


Asunto(s)
Antiinfecciosos Locales/uso terapéutico , Placa Dental/prevención & control , Gingivitis/prevención & control , Hexetidina/uso terapéutico , Antisépticos Bucales/uso terapéutico , Adolescente , Adulto , Análisis de Varianza , Clorhexidina/uso terapéutico , Índice de Placa Dental , Femenino , Humanos , Masculino , Persona de Mediana Edad , Índice Periodontal , Método Simple Ciego , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...