Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 14 de 14
Filtrar
1.
J Nucl Med ; 2024 Jun 27.
Artículo en Inglés | MEDLINE | ID: mdl-38936975

RESUMEN

Internal dosimetry supports safe and effective patient management during radionuclide therapy. Yet, it is associated with high clinical workload, costs, and patient burden, as patient scans at multiple time points (MTPs) must be acquired. Dosimetry based on imaging at a single time point (STP) has continuously gained popularity. However, MTP protocols, used as a reference to judge the validity of STP dosimetry, differ depending on local requirements and deviate from the unknown patient-specific ground truth pharmacokinetics. The aim of this study was to compare the error and optimum time point for different STP approaches using different reference MTP protocols. Methods: Whole-body SPECT/CT scans of 7 patients (7.4-8.9 GBq of [177Lu]Lu-PSMA-I&T) were scheduled at 24, 48, 72, and 168 h after injection. Sixty lesions, 14 kidneys, and 10 submandibular glands were delineated in the SPECT/CT data. Two curve models, that is, a mono- and a biexponential model, were fitted to the MTP data, in accordance with goodness-of-fit analysis (coefficients of variation, sum of squared errors). Three population-based STP approaches were compared: one method published by Hänscheid et al., one by Jackson et al., and one using population-based effective half-lives in the mono- or biexponential curve models. Percentage differences between STP and MTP dosimetry were evaluated. Results: Goodness-of-fit parameters show that a monoexponential function and a biexponential function with shared population-based parameters and physical tail are reasonable reference models. When comparing both reference models, we observed maximum differences of -44%, -19%, and -28% in the estimated absorbed doses for lesions, kidneys, and salivary glands, respectively. STP dosimetry with an average deviation of less than 10% from MTP dosimetry may be feasible; however, this deviation and the optimum imaging time point showed a dependence on the chosen reference protocol. Conclusion: STP dosimetry for [177Lu]Lu-PSMA therapy is promising to boost the integration of dosimetry into clinical routine. According to our patient cohort, 48 h after injection may be regarded as a compromise for STP dosimetry for lesions and at-risk organs. The results from this analysis show that a common gold standard for dosimetry is desirable to allow for reliable and comparable STP dosimetry.

2.
Eur Radiol ; 34(2): 1157-1166, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-37624414

RESUMEN

OBJECTIVES: As structured reporting is increasingly used in the evaluation of prostate-specific membrane antigen positron emission tomography/computed tomography (PSMA-PET/CT) for prostate cancer, there is a need to assess the reliability of these frameworks. This study aimed to evaluate the intra- and interreader agreement among readers with varying levels of experience using PSMA-RADS 1.0 for interpreting PSMA-PET/CT scans, even when blinded to clinical data, and therefore to determine the feasibility of implementing this reporting system in clinical practice. METHODS: PSMA-PET/CT scans of 103 patients were independently evaluated by 4 readers with different levels of experience according to the reporting and data system (RADS) for PSMA-PET/CT imaging PSMA-RADS 1.0 at 2 time points within 6 weeks. For each scan, a maximum of five target lesions were freely chosen and stratified according to PSMA-RADS 1.0. Overall scan score and compartment-based scores were assessed. Intra- and interreader agreement was determined using the intraclass correlation coefficient (ICC). RESULTS: PSMA-RADS 1.0 demonstrated excellent interreader agreement for both overall scan scores (ICC ≥ 0.91) and compartment-based scores (ICC ≥ 0.93) across all four readers. The framework showed excellent intrareader agreement for overall scan scores (ICC ≥ 0.86) and compartment-based scores (ICC ≥ 0.95), even among readers with varying levels of experience. CONCLUSIONS: PSMA-RADS 1.0 is a reliable method for assessing PSMA-PET/CT with strong consistency and agreement among readers. It shows great potential for establishing a standard approach to diagnosing and planning treatment for prostate cancer patients, and can be used confidently even by readers with less experience. CLINICAL RELEVANCE STATEMENT: This study underlines that PSMA-RADS 1.0 is a valuable and highly reliable scoring system for PSMA-PET/CT scans of prostate cancer patients and can be used confidently by radiologists with different levels of experience in routine clinical practice. KEY POINTS: PSMA-RADS version 1.0 is a scoring system for PSMA-PET/CT scans. Its reproducibility needs to be analyzed in order to make it applicable to clinical practice. Excellent interreader and intrareader agreement for overall scan scores and compartment-based scores using PSMA-RADS 1.0 were seen in readers with varying levels of experience. PSMA-RADS 1.0 is a reliable tool for accurately diagnosing and planning treatment for prostate cancer patients, and can be used confidently in clinical routine.


Asunto(s)
Tomografía Computarizada por Tomografía de Emisión de Positrones , Neoplasias de la Próstata , Humanos , Masculino , Tomografía Computarizada por Tomografía de Emisión de Positrones/métodos , Reproducibilidad de los Resultados , Neoplasias de la Próstata/diagnóstico por imagen , Neoplasias de la Próstata/patología , Diagnóstico por Imagen , Radiólogos , Radioisótopos de Galio
3.
Cancers (Basel) ; 15(14)2023 Jul 13.
Artículo en Inglés | MEDLINE | ID: mdl-37509258

RESUMEN

BACKGROUND: Given the dismal prognosis of small cell lung cancer (SCLC), novel therapeutic targets are urgently needed. We aimed to evaluate whether SSTR expression, as assessed by positron emission tomography (PET), can be applied as a prognostic image biomarker and determined subjects eligible for peptide receptor radionuclide therapy (PRRT). METHODS: A total of 67 patients (26 females; age, 41-80 years) with advanced SCLC underwent SSTR-directed PET/computed tomography (somatostatin receptor imaging, SRI). SRI-avid tumor burden was quantified by maximum standardized uptake values (SUVmax) and tumor-to-liver ratios (T/L) of the most intense SCLC lesion. Scan findings were correlated with progression-free (PFS) and overall survival (OS). In addition, subjects eligible for SSTR-directed radioligand therapy were identified, and treatment outcome and toxicity profile were recorded. RESULTS: On a patient basis, 36/67 (53.7%) subjects presented with mainly SSTR-positive SCLC lesions (>50% lesions positive); in 10/67 patients (14.9%), all lesions were positive. The median SUVmax was found to be 8.5, while the median T/L was 1.12. SRI-uptake was not associated with PFS or OS, respectively (SUVmax vs. PFS, ρ = 0.13 with p = 0.30 and vs. OS, ρ = 0.00 with p = 0.97; T/L vs. PFS, ρ = 0.07 with p = 0.58 and vs. OS, ρ = -0.05 with p = 0.70). PRRT was performed in 14 patients. One patient succumbed to treatment-independent infectious complications immediately after PRRT. In the remaining 13 subjects, disease control was achieved in 5/13 (38.5%) with a single patient achieving a partial response (stable disease in the remainder). In the sub-group of responding patients, PFS and OS were 357 days and 480 days, respectively. CONCLUSIONS: SSTR expression as detected by SRI is not predictive of outcome in patients with advanced SCLC. However, it might serve as a therapeutic target in selected patients.

4.
Eur Radiol ; 33(5): 3416-3424, 2023 May.
Artículo en Inglés | MEDLINE | ID: mdl-36964768

RESUMEN

OBJECTIVES: The recently proposed standardized reporting and data system for somatostatin receptor (SSTR)-targeted PET/CT SSTR-RADS 1.0 showed promising first results in the assessment of diagnosis and treatment planning with peptide receptor radionuclide therapy (PRRT) in neuroendocrine tumors (NET). This study aimed to determine the intra- and interreader agreement of SSTR-RADS 1.0. METHODS: SSTR-PET/CT scans of 100 patients were independently evaluated by 4 readers with different levels of expertise according to the SSTR-RADS 1.0 criteria at 2 time points within 6 weeks. For each scan, a maximum of five target lesions were freely chosen by each reader (not more than three lesions per organ) and stratified according to the SSTR-RADS 1.0 criteria. Overall scan score and binary decision on PRRT were assessed. Intra- and interreader agreement was determined using the intraclass correlation coefficient (ICC). RESULTS: Interreader agreement using SSTR-RADS 1.0 for identical target lesions (ICC ≥ 0.91) and overall scan score (ICC ≥ 0.93) was excellent. The decision to state "functional imaging fulfills requirements for PRRT and qualifies patient as potential candidate for PRRT" also demonstrated excellent agreement among all readers (ICC ≥ 0.86). Intrareader agreement was excellent even among different experience levels when comparing target lesion-based scores (ICC ≥ 0.98), overall scan score (ICC ≥ 0.93), and decision for PRRT (ICC ≥ 0.88). CONCLUSION: SSTR-RADS 1.0 represents a highly reproducible and accurate system for stratifying SSTR-targeted PET/CT scans with high intra- and interreader agreement. The system is a promising approach to standardize the diagnosis and treatment planning in NET patients. KEY POINTS: • SSTR-RADS 1.0 offers high reproducibility and accuracy. • SSTR-RADS 1.0 is a promising method to standardize diagnosis and treatment planning for patients with NET.


Asunto(s)
Tumores Neuroendocrinos , Tomografía Computarizada por Tomografía de Emisión de Positrones , Humanos , Receptores de Somatostatina , Tumores Neuroendocrinos/diagnóstico por imagen , Tumores Neuroendocrinos/terapia , Tumores Neuroendocrinos/patología , Reproducibilidad de los Resultados , Cintigrafía
5.
J Nucl Med ; 64(6): 918-923, 2023 06.
Artículo en Inglés | MEDLINE | ID: mdl-36732055

RESUMEN

Salvage elective nodal radiotherapy (ENRT) is a treatment option for patients with biochemically persistent or recurrent prostate cancer who have lymph node metastases (LNs) after prostatectomy. Possible ENRT templates were proposed by the Radiation Therapy Oncology Group (RTOG; 2009), the PIVOTAL trialists (2015), and the NRG Oncology Group (2021). The goal of this study was to analyze the distribution of prostate-specific membrane antigen (PSMA) PET/CT-positive LNs and to compare the templates regarding their LN coverage. Methods: We analyzed the PSMA PET/CT scans of 105 patients with PET-positive LNs treated with salvage ENRT from 2014 to 2019. All LNs were mapped in an exemplary dataset, classified by region, and assessed with regard to their potential coverage by the 3 ENRT templates. The primary endpoint was the number of missed LNs. The secondary endpoint was the number of patients with full coverage. To compare the templates, a t test and McNemar test were used. Results: Three hundred thirty-five LNs were contoured (3.19 per patient; 95% CI, 2.43-3.95). Most frequently, LNs were seen in the internal iliac (n = 94, 28.1%), external iliac (n = 60, 17.9%), periaortic (n = 58, 17.3%), common iliac (n = 55, 16.4%), perirectal (n = 26, 7.8%), and presacral (n = 19, 5.7%) regions. The NRG template missed fewer LNs per patient (1.01, 31.7%) than the RTOG (1.28, 40.1%, P < 0.001) and PIVOTAL templates (1.19, 37.3%, P = 0.003). No difference was observed in the number of patients with full coverage of all LNs: 52 (49.5%) with the NRG template versus 50 (47.6%) with the RTOG (P = 0.625) and 49 (46.7%) with the PIVOTAL template (P = 0.250). Conclusion: The NRG template showed better coverage than the RTOG and PIVOTAL templates. Nevertheless, in this cohort, it would have missed almost one third of all contoured LNs and would have resulted in incomplete coverage in half the patients. This result underlines the importance of advanced imaging, such as PSMA PET/CT scans, before salvage ENRT and shows the need for further individualization of ENRT fields.


Asunto(s)
Tomografía Computarizada por Tomografía de Emisión de Positrones , Neoplasias de la Próstata , Masculino , Humanos , Tomografía Computarizada por Tomografía de Emisión de Positrones/métodos , Isótopos de Galio , Radioisótopos de Galio , Recurrencia Local de Neoplasia/diagnóstico por imagen , Neoplasias de la Próstata/diagnóstico por imagen , Neoplasias de la Próstata/radioterapia , Neoplasias de la Próstata/cirugía , Prostatectomía , Ganglios Linfáticos/patología
6.
Front Oncol ; 13: 992316, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-36793617

RESUMEN

Purpose: Somatostatin analogues (SSA) are frequently used in the treatment of neuroendocrine tumours. Recently, [18F]SiTATE entered the field of somatostatin receptor (SSR) positron emission tomography (PET)/computed tomography (CT) imaging. The purpose of this study was to compare the SSR-expression of differentiated gastroentero-pancreatic neuroendocrine tumours (GEP-NET) measured by [18F]SiTATE-PET/CT in patients with and without previous treatment with long-acting SSAs to evaluate if SSA treatment needs to be paused prior to [18F]SiTATE-PET/CT. Methods: 77 patients were examined with standardised [18F]SiTATE-PET/CT within clinical routine: 40 patients with long-acting SSAs up to 28 days prior to PET/CT examination and 37 patients without pre-treatment with SSAs. Maximum and mean standardized uptake values (SUVmax and SUVmean) of tumours and metastases (liver, lymphnode, mesenteric/peritoneal and bones) as well as representative background tissues (liver, spleen, adrenal gland, blood pool, small intestine, lung, bone) were measured, SUV ratios (SUVR) were calculated between tumours/metastases and liver, likewise between tumours/metastases and corresponding specific background, and compared between the two groups. Results: SUVmean of liver (5.4 ± 1.5 vs. 6.8 ± 1.8) and spleen (17.5 ± 6.8 vs. 36.7 ± 10.3) were significantly lower (p < 0.001) and SUVmean of blood pool (1.7 ± 0.6 vs. 1.3 ± 0.3) was significantly higher (p < 0.001) in patients with SSA pre-treatment compared to patients without. No significant differences between tumour-to-liver and specific tumour-to-background SUVRs were observed between both groups (all p > 0.05). Conclusion: In patients previously treated with SSAs, a significantly lower SSR expression ([18F]SiTATE uptake) in normal liver and spleen tissue was observed, as previously reported for 68Ga-labelled SSAs, without significant reduction of tumour-to-background contrast. Therefore, there is no evidence that SSA treatment needs to be paused prior to [18F]SiTATE-PET/CT.

7.
EJNMMI Phys ; 10(1): 11, 2023 Feb 09.
Artículo en Inglés | MEDLINE | ID: mdl-36757516

RESUMEN

BACKGROUND: 177Lu-PSMA therapy has been successfully used to prolong the survival of patients with metastatic castration-resistant prostate cancer. Patient-specific dosimetry based on serial quantitative SPECT/CT imaging can support the understanding of dose-effect relationships. However, multiple SPECT/CT measurements can be challenging for patients, which motivates the investigation of efficient sampling schedules and their impact on dosimetry. In this study, different time samplings with respect to the number and timing of SPECT/CT acquisitions with and without a late measurement were investigated. MATERIALS AND METHODS: In total, 43 lesions and 10 kidneys of 5 patients receiving 177Lu-PSMA-I&T therapy were investigated. Whole-body SPECT/CT measurements were performed at 1, 2, 3 and 7 days post-injection. For both lesions (isocontour-based segmentation) and kidneys (CT-based segmentation), a reference model was employed including all four time points. To identify the best-matching fit function out of a pre-defined set of models, visual inspection, coefficients of variation and sum of squared errors were considered as goodness-of-fit criteria. Biologically effective doses (BEDs) calculated with different time samplings (days 1, 2, 3/1, 2, 7/1, 3, 7/2, 3, 7 and 1, 2/1, 3/1, 7) were compared to the reference. RESULTS: The best-fit function was found to be a mono-exponential model for lesions and a bi-exponential model with a population-based parameter and two free parameters for kidneys. The BEDs calculated with the time sampling 1, 3, 7 days showed the lowest deviations from the reference for lesions with 4 ± 5%. Without day 7, still 86% of all lesions showed deviations from the reference < 10%. The outlier deviations showed a positive correlation with the effective half-life of the respective lesions. For kidneys, including days 1, 2, 3 achieved the best results with 0 ± 1%. Generally, deviations for kidneys were found to be small for all time samplings (max. 13%). CONCLUSIONS: For combined optimization of the SPECT/CT time sampling for kidney and lesion dosimetry during 177Lu-PSMA-I&T therapy, the sampling with days 1, 3, 7 showed the smallest deviation from the reference. Without a late acquisition, using the schedule with days 1, 2, 3 is likewise feasible.

8.
Clin Nucl Med ; 48(3): 207-212, 2023 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-36723879

RESUMEN

BACKGROUND: Recommended by current guidelines, prostate-specific membrane antigen (PSMA)-directed PET/CT is increasingly used in men with prostate cancer (PC). We aimed to provide concordance rates using the PSMA reporting and data system (RADS) for scan interpretation and also determine whether such agreement rates are affected by available patient characteristics at time of scan. PATIENTS AND METHODS: Sixty men with PC, who all underwent 68Ga-PSMA-11 PET/CT, were included. Three independent, experienced readers indicated general scan parameters (including overall scan result, organ or lymph node [LN] involvement, and appropriateness of radioligand therapy). Applying PSMA-RADS 1.0, observers also had to conduct RADS scoring on a target lesion (TL) and overall scan level. During the first read, observers were masked to all relevant clinical information, whereas on a second read, relevant patient characteristics were displayed, thereby allowing for determination of impact of available clinical information for scan interpretation. We used intraclass correlation coefficients (ICCs; with 95% confidence intervals [CIs]), which were then rated according to Cicchetti (0.4-0.59 fair, 0.6-0.74 good, and 0.75-1 excellent agreement). RESULTS: For general parameters, agreement rates were excellent, including an overall scan result (ICC, 0.85; 95% CI, 0.76-0.90), LN metastases (ICC, 0.89; 95% CI, 0.83-0.93), organ involvement (ICC, 0.82; 95% CI, 0.72-0.89), and indication for radioligand therapy (ICC, 0.94; 95% CI, 0.90-0.96). Overall RADS scoring was also excellent with an ICC of 0.91 (95% CI, 0.96-09.4). On a TL-based level, 251 different lesions were selected by the 3 observers (with 73 chosen by all 3 readers). RADS-based concordance rates were fair to excellent: all lesions, ICC of 0.78 (95% CI, 0.67-0.85); LN, ICC of 0.81 (95% CI, 0.63-0.92); skeleton, ICC of 0.55 (95% CI, 0-0.84); and prostate, ICC of 0.48 (95% CI, 0.17-0.78). When performing a second read displaying patient's characteristics, there were only minor modifications to the previously applied RADS scoring on a TL-based level (overall, n = 8): each reader 1 and 2 in 3/60 (5%) instances, and reader 3 in 2/60 (3.3%) instances. The main reason for recategorization (mainly upstaging) was provided information on PSA levels (4/8, 50%). CONCLUSIONS: Applying PSMA-RADS, concordance rates were fair to excellent, whereas relevant modifications were rarely observed after providing clinical data. As such, even in the absence of patient information, standardized frameworks still provide guidance for reading PSMA PETs. Those findings may have implications for a high throughput in a busy PET practice, where patient details cannot always be retrieved at time of scan interpretation or in the context of clinical trials or central reviews in which readers may be blinded to clinical data.


Asunto(s)
Tomografía Computarizada por Tomografía de Emisión de Positrones , Neoplasias de la Próstata , Masculino , Humanos , Variaciones Dependientes del Observador , Neoplasias de la Próstata/patología , Radioisótopos de Galio
9.
Biomedicines ; 10(5)2022 Apr 20.
Artículo en Inglés | MEDLINE | ID: mdl-35625683

RESUMEN

Background: PSMA-based alpha therapy using 225Ac-PSMA-I&T provides treatment for metastatic castration-resistant prostate cancer (mCRPC), even after the failure of 177Lu-PSMA radioligand therapy (RLT). In clinical routine, the total tumor volume (TTV) on PSMA PET impacts therapy outcomes and plays an increasing role in mCRPC patients. Hence, we aimed to assess TTV and its changes during 225Ac-PSMA-I&T RLT. Methods: mCRPC patients undergoing RLT with 225Ac-PSMA-I&T with available 18F-PSMA-1007 PET/CT prior to therapy initiation were included. TTV was assessed in all patients using established cut-off values. Image derived, clinical and biochemistry parameters (PSA, LDH, AP, pain score) were analyzed prior to and after two cycles of 225Ac-PSMA. Changes in TTV and further parameters were directly compared and then correlated with established response criteria, such as RECIST 1.1 or mPERCIST. Results: 13 mCRPC patients were included. The median overall survival (OS) was 10 months. Prior to 225Ac-PSMA RLT, there was no significant correlation between TTV with other clinical parameters (p > 0.05 each). Between short-term survivors (STS, <10 months OS) and long-term survivors (LTS, ≥10 months OS), TTV and PSA were comparable (p = 0.592 & p = 0.286, respectively), whereas AP was significantly lower in the LTS (p = 0.029). A total of 7/13 patients completed two cycles and underwent a follow-up 18F-PSMA-1007 PET/CT. Among these patients, there was a significant decrease in TTV (median 835 vs. 201 mL, p = 0.028) and PSA (median 687 ng/dL vs. 178 ng/dL, p = 0.018) after two cycles of 225Ac-PSMA RLT. Here, percentage changes of TTV after two cycles showed no direct correlation to all other clinical parameters (p > 0.05 each). In two patients, new PET-avid lesions were detected on 18F-PSMA-1007 PET/CT. However, TTV and PSA were decreasing or stable. Conclusion: PET-derived assessment of TTV is an easily applicable imaging biomarker independent of other established parameters prior to 225Ac-PSMA RLT in these preliminary follow-up data. Even after the failure of 177Lu-PSMA, patients with extensive TTV seem to profit from RLT. All but one patient who was eligible for ≥2 cycles of 225Ac-PSMA-RLT demonstrated drastic TTV decreases without direct correlation to other biomarkers, such as serum PSA changes. Changes in TTV might hence improve the response assessment compared to standard classifiers by reflecting the current tumor load independent of the occurrence of new lesions.

10.
J Nucl Med ; 62(4): 514-520, 2021 04.
Artículo en Inglés | MEDLINE | ID: mdl-32859702

RESUMEN

Recently, a standardized framework system for interpreting somatostatin receptor (SSTR)-targeted PET/CT, termed the SSTR reporting and data system (RADS) 1.0, was introduced, providing reliable standards and criteria for SSTR-targeted imaging. We determined the interobserver reliability of SSTR-RADS for interpretation of 68Ga-DOTATOC PET/CT scans in a multicentric, randomized setting. Methods: A set of 51 randomized 68Ga-DOTATOC PET/CT scans was independently assessed by 4 masked readers with different levels of experience (2 experienced readers and 2 inexperienced readers) trained on the SSTR-RADS 1.0 criteria (based on a 5-point scale from 1 [definitively benign] to 5 [high certainty that neuroendocrine neoplasia is present]). For each scan, SSTR-RADS scores were assigned to a maximum of 5 target lesions (TLs). An overall scan impression based on SSTR-RADS was indicated, and interobserver agreement rates on a TL-based, on an organ-based, and on an overall SSTR-RADS score-based level were computed. The readers were also asked to decide whether peptide receptor radionuclide therapy (PRRT) should be considered on the basis of the assigned RADS scores. Results: Among the selected TLs, 153 were chosen by at least 2 readers (all 4 readers selected the same TLs in 58 of 153 [37.9%] instances). The interobserver agreement for SSTR-RADS scoring among identical TLs was good (intraclass correlation coefficient [ICC] ≥ 0.73 for 4, 3, and 2 identical TLs). For lymph node and liver lesions, excellent interobserver agreement rates were derived (ICC, 0.91 and 0.77, respectively). Moreover, the interobserver agreement for an overall scan impression based on SSTR-RADS was excellent (ICC, 0.88). The SSTR-RADS-based decision to use PRRT also demonstrated excellent agreement, with an ICC of 0.80. No significant differences between experienced and inexperienced readers for an overall scan impression and TL-based SSTR-RADS scoring were observed (P ≥ 0.18), thereby suggesting that SSTR-RADS seems to be readily applicable even for less experienced readers. Conclusion: SSTR-RADS-guided assessment demonstrated a high concordance rate, even among readers with different levels of experience, supporting the adoption of SSTR-RADS for trials, clinical routine, or outcome studies.


Asunto(s)
Octreótido/análogos & derivados , Compuestos Organometálicos , Tomografía Computarizada por Tomografía de Emisión de Positrones , Receptores de Somatostatina/metabolismo , Proyectos de Investigación/normas , Femenino , Humanos , Procesamiento de Imagen Asistido por Computador , Masculino , Persona de Mediana Edad , Variaciones Dependientes del Observador , Estándares de Referencia
11.
Cardiovasc Intervent Radiol ; 43(2): 231-237, 2020 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-31531692

RESUMEN

PURPOSE: To assess the detectability and frequency of the different types of utero-ovarian anastomosis, the correlation between type of anastomosis and ovarian failure after UAE, as well as the impact of coiling as a strategy for the prevention of ovarian failure. MATERIALS AND METHODS: We retrospectively studied a population of 92 women treated with uterine artery embolization at our institution between 2007 and 2017. Utero-ovarian anastomoses were categorized on angiographic sequences by two radiologists based on the classification published by Razavi et al. (Radiology 224(3):707-712, 2002), and Cohen's kappa was calculated. Ovarian failure was defined as an increase in serum FSH above 27 mIU/ml three months after embolization. RESULTS: Out of a total of 184 anastomoses, 27% were classified as type Ia, 45% as type Ib, 1% as type II and 24% as type III. Three percent of anastomoses could not be determined. There was very good inter-observer reliability on the classification of utero-ovarian anastomoses (κ = 0.847). Ovarian failure occurred in six out of 92 women (7%). Each had at least one type Ib (n = 4) or type III (n = 1) anastomosis, with the exception of one patient in whom the type of anastomosis could not be determined. All women presenting with ovarian failure were 45 years of age or older. No patient with protective coiling developed ovarian failure. CONCLUSION: Utero-ovarian anastomoses are more common than previously expected and can be reliably classified with very good inter-observer reliability. Patients with type Ib and type III anastomoses carry the risk of ovarian failure after uterine artery embolization. Protective coiling seems to be an adequate strategy for avoiding ovarian failure in those types of anastomoses.


Asunto(s)
Enfermedades del Ovario/prevención & control , Ovario/irrigación sanguínea , Embolización de la Arteria Uterina/métodos , Arteria Uterina/anatomía & histología , Arteria Uterina/diagnóstico por imagen , Adulto , Angiografía/métodos , Arterias/diagnóstico por imagen , Femenino , Humanos , Persona de Mediana Edad , Ovario/diagnóstico por imagen , Reproducibilidad de los Resultados , Estudios Retrospectivos , Resultado del Tratamiento
12.
Rofo ; 191(11): 1010-1014, 2019 Nov.
Artículo en Inglés, Alemán | MEDLINE | ID: mdl-30947350

RESUMEN

AIM: Segmental arterial mediolysis (SAM) is a rare non-atherosclerotic, non-inflammatory, non-infectious arteriopathy in middle-aged patients that tends to affect medium-sized splanchnic arteries typically leading to dissecting aneurysms which in case of rupture have a high mortality. Treatment options include watchful waiting and endovascular or surgical intervention. There are no official treatment guidelines and to the best of our knowledge, there has not been any report of extensive exclusion of multiple splanchnic vessel regions in affected patients to date. MATERIALS AND METHODS: We retrospectively examined the outcome of extensive splanchnic embolization in four patients suffering from SAM between 2011 and 2016 with follow-up periods of up to 7 years. RESULTS: One patient presented with abdominal pain due to rupture of aneurysms of the pancreaticoduodenal arcade, one with abdominal pain due to dissection, and two were clinically asymptomatic but displayed rapidly progressing disease over the course of 12 months. All patients were treated with complete exclusion of the diseased vessel segments by coiling all branches to and from the diseased segment. In three cases the main hepatic artery was excluded completely. In one case, the complete vascular bed of the celiac axis was excluded by coiling the distal vessel branches and placing a stent graft over the orifice of the celiac trunk. During a follow-up period of a minimum of 2 and a maximum of 7 years after intervention, there were no immediate or long-term complications except for a temporary arterio-portal fistula. Interestingly, no new diseased areas of SAM were detected afterwards. CONCLUSION: Extensive endovascular exclusion of the entire diseased arterial segment with coils seems to be a safe and effective treatment option in patients with SAM presenting with ruptured or rapidly growing aneurysms. Provided that patients have normal liver function and proper portal venous flow, risk of hepatobiliary complications seems to be low even after extensive embolization. KEY POINTS: · An asymptomatic SAM can be followed up.. · In case of disease progression or suspicion of aneurysm rupture, an endovascular approach is indicated where the whole pathological vessel bed should be excluded with coils.. · It seems that exclusion of even extensive vessel areas is tolerated.. CITATION FORMAT: · Najafi A, Sheikh GT, Binkert C. Extensive Embolization of Splanchnic Artery Aneurysms due to Segmental Arterial Mediolysis. Fortschr Röntgenstr 2019; 191: 1010 - 1014.


Asunto(s)
Aneurisma Roto/terapia , Aneurisma/terapia , Disección Aórtica/terapia , Embolización Terapéutica/métodos , Arterias Mesentéricas , Dolor Abdominal/etiología , Anciano , Anciano de 80 o más Años , Progresión de la Enfermedad , Procedimientos Endovasculares , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Resultado del Tratamiento , Túnica Media
13.
CVIR Endovasc ; 2(1): 13, 2019 Apr 23.
Artículo en Inglés | MEDLINE | ID: mdl-32025997

RESUMEN

BACKGROUND: Endovascular aortic sealing (EVAS) using the Nellix system was a new approach to reduce the frequency of type II endoleaks after endovascular aortic repair. We analyzed the mid-term results, specifically looking at device migration, endoleaks and subsequent necessary secondary interventions. RESULTS: Ten patients underwent elective EVAS treatment during our study period. 7 patients were within the IFU while 3 patients had a proximal neck shorter than 10 mm. Technical success rate was 100% and there were no short-term vascular complications. One patient died from urosepsis 14 days after the procedure and was excluded from further analysis. A total of 6 out of 9 patients (67%) experienced device complications such as proximal graft kinking, limb separation or caudal migration. 5 also showed type Ia endoleak. DISCUSSION: While no complication occurred short-term (up to 12 months), the Nellix system showed a high percentage of limb separation, caudal graft migration, and type Ia endoleak on mid-term follow-up, likely due to insufficient proximal anchoring of the device. Possible salvage treatments are discussed.

14.
CVIR Endovasc ; 2(1): 23, 2019 Jul 18.
Artículo en Inglés | MEDLINE | ID: mdl-32026995

RESUMEN

BACKGROUND: The standard approach for crossing peripheral CTOs is to use a combination of hydrophilic guidewires and catheters. The path is either intraluminally or in most cases at least partially subintimal. This standard approach with a guidewire-tip as leading point ("wire first") to cross CTOs has a success rate of about 80%. We hypothesize that a "catheter first" approach, using the catheter alone for the entire recanalization till re-entering the vessel is less traumatic and might lead to a longer intraluminal recanalization due to a softer leading point. Based on this assumption we analyzed the success and duration of this approach with a gradual step-up approach from catheter tip to guidewire front-end to guidewire back-end. To the best of our knowledge, no studies measuring the time of recanalization of lower extremity CTOs using conventional devices were published yet. RESULTS: Data of 46 consecutive chronic total iliaco-femoro-popliteal occlusions in 43 symptomatic patients treated by percutaneous transluminal angioplasty were collected prospectively between May 1st 2014 and June 30th 2016 and evaluated retrospectively. Chronic occlusion was defined as clinical symptoms or imaging features lasting more than 1 month. Patient age and gender, diabetes status, localization of occlusion, occlusion length, duration of symptoms, severity of vessel calcification, and recanalization time were assessed. Technical success was defined as placement of a catheter beyond the distal end of the lesion into the true lumen, confirmed by contrast injection. All 46 CTOs were successfully recanalized. In 22 cases (47.8%) recanalization was successful with the catheter tip only without the use of a guide wire. In 17 cases (36.9%) the guide wire was used in addition to the catheter. Localization of occlusion did not have an effect on the recanalization technique (p = 0.915). The mean rank for length of occlusion was not significant for different recanalization techniques (p = 0.095). The success rate for the catheter only approach was lower for higher grades of calcification (p = 0.008). There was no correlation between time of recanalization and length of occlusion (Pearson's r = 0.004; adjusted R square = - 0.024; p = 0.980), diabetes (p = 1.000), sex (p = 0.244), or grade of calcification (p = 0.621). Recanalization time is significantly right-skewed with most recanalizations being successful under 30 min. CONCLUSION: This "catheter first" approach is somewhat contradictory to the prevailing dogma of "wire first". The concept to use the catheter to start a recanalization is well known, but to perform the entire recanalization including the re-entry seems possible and potentially less traumatic, likely leading to a longer intraluminal course. Our data shows that recanalization of occluded lower extremity arteries between the aortic bifurcation and the popliteal artery can be achieved in the majority of cases (84.7%) solely by using an angled angiographic catheter +/- glide wire. We suggest a "5 min - 15 min - 30 min" rule on how long to attempt each recanalization technique. More precisely, we suggest trying 5 min with the catheter alone, then 10 min with the soft end of the guidewire and then switching to the stiffer back-end of the guidewire for another 15 min.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...