J Am Soc Mass Spectrom ; 35(1): 40-49, 2024 Jan 03.
Artículo en Inglés | MEDLINE | ID: mdl-38109269

RESUMEN

A new, rapid, and automated method for the quantitation of 21 synthetic cathinones in urine was established using magnetic dispersive solid-phase extraction (MDSPE) in combination with direct analysis in real time-high-resolution mass spectrometry (DART-HRMS). Sample preparation and quantitation were verified by liquid chromatography-tandem mass spectrometry (LC-MS/MS). Methcathinone-D3, α-PVP-D8, and proadifen (SKF525A) were used as internal standards. Magnetic HLB extractant and NaH2PO4/NaOH buffer (0.2 M, pH 7) were used in automatic MDSPE. All 21 synthetic cathinones could be detected and analyzed by DART-HRMS in under 1 min. It was proven that the linearities of 21 synthetic cathinones were suitable (R2 > 0.99) in the concentration ranges of 0.5-100 ng/mL or 1-100 ng/mL. The precision and accuracy values were all within ±15%, and the samples were stable under various conditions. The average time of each sample from preprocessing to completion of detection was approximately 2 min, allowing for rapid sample analysis. The relative error (RE) of the concentrations obtained by DART-HRMS and LC-MS/MS were within ±13.61%, and the linear coefficient (R) was 0.9964. The results of DART-HRMS and LC-MS/MS provided equivalent values at the 95% confidence level. In summary, a simple, fast, and convenient quantitation method via DART-HRMS was established. This application can be utilized to reduce backlogs and promote rapid case processing.


Asunto(s)
Cathinona Sintética , Espectrometría de Masas en Tándem , Cromatografía Liquida/métodos , Extracción en Fase Sólida , Estándares de Referencia
2.
J Sep Sci ; 43(19): 3735-3747, 2020 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-32725936

RESUMEN

A method for separation and determination of 32 fentanyl-related substances, including seven sets of isomeric fentanyl analogues, was developed using ultra-high-performance liquid chromatography coupled with quadrupole-orbitrap high-resolution mass spectrometry. The collision energy, chromatographic column, and mobile phase were optimized. All compounds were efficiently flushed out of a universal C18 column with a soft gradient consisting of solvent A (2 mM ammonium formate and 0.1% formic acid in water) and solvent B (2 mM ammonium formate and 0.1% formic acid in methanol) in only 20 min, achieving excellent resolution. Detection and analysis were carried out simultaneously in the positive ion mode using the full scan and data-dependent tandem mass spectrometry modes with a normalized collision energy of 40. The method was validated in terms of limit of detection, limit of quantification, linearity, accuracy, and precision. For all fentanyl-related substances, the limit of detection (0.5 ng/mL) and limit of quantification (1 ng/mL) were adequate for screening and quantification in daily drug control. Calibration curves for all compounds were established in the range of 1-500 ng/mL. The intra- and interday precision (RSD%) were within 0.4-2.3 and 0.7-2.7%, respectively. The accuracy ranged from 99 to 106%. The method was applied to analyze seized drug samples.


Asunto(s)
Cromatografía Líquida de Alta Presión/métodos , Fentanilo/análisis , Espectrometría de Masas/métodos , Calibración , Isomerismo , Narcóticos/análisis
3.
J Anal Toxicol ; 44(1): 22-28, 2020 Jan 07.
Artículo en Inglés | MEDLINE | ID: mdl-31095707

RESUMEN

Heroin abuse is a serious problem that endangers human health and affects social stability. Though often being used as confirmation of heroin use, 6-monoacetylmorphine (6-MAM) has limitations due to its short detection window. To compare the detection windows of heroin metabolites (morphine (MOR), 6-MAM, morphine-3-glucuronide (M3G) and morphine-6-glucuronide (M6G)) in human urine, an automated online solid phase extraction (SPE) and liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was developed and fully validated. The limits of detections (LODs) of the four metabolites were in the range of 1.25-5 ng/mL. Intra and inter-day precision for all the metabolites was 0.4-6.7% and 1.8-7.3%, respectively. Accuracy ranged from 92.9 to 101.7%. This method was then applied to the analysis of urine samples of 20 male heroin abusers. M3G was detected 9-11 days after admission to the drug rehabilitation institute in 40% of heroin users while MOR or M6G was not always detected. The detection window of M3G was thus the longest. Furthermore, M3G had a much higher concentration than MOR and M6G. Therefore, M3G could provide diagnostic information with regard to heroin exposure in the combination with other clues (e.g., heroin seizures at the scene).


Asunto(s)
Dependencia de Heroína/orina , Derivados de la Morfina/orina , Detección de Abuso de Sustancias/métodos , Cromatografía Líquida de Alta Presión , Cromatografía Liquida , Heroína , Humanos , Límite de Detección , Extracción en Fase Sólida , Espectrometría de Masas en Tándem