Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Environ Sci Process Impacts ; 25(9): 1491-1504, 2023 Sep 20.
Artículo en Inglés | MEDLINE | ID: mdl-37584085

RESUMEN

Exposures to metals from industrial emissions can pose important health risks. The Chester-Trainer-Marcus Hook area of southeastern Pennsylvania is home to multiple petrochemical plants, a refinery, and a waste incinerator, most abutting socio-economically disadvantaged residential communities. Existing information on fenceline community exposures is based on monitoring data with low temporal and spatial resolution and EPA models that incorporate industry self-reporting. During a 3 week sampling campaign in September 2021, size-resolved particulate matter (PM) metals concentrations were obtained at a fixed site in Chester and on-line mobile aerosol measurements were conducted around Chester-Trainer-Marcus Hook. Fixed-site arsenic, lead, antimony, cobalt, and manganese concentrations in total PM were higher (p < 0.001) than EPA model estimates, and arsenic, lead, and cadmium were predominantly observed in fine PM (<2.5 µm), the PM fraction which can penetrate deeply into the lungs. Hazard index analysis suggests adverse effects are not expected from exposures at the observed levels; however, additional chemical exposures, PM size fraction, and non-chemical stressors should be considered in future studies for accurate assessment of risk. Fixed-site MOUDI and nearby mobile aerosol measurements were moderately correlated (r ≥ 0.5) for aluminum, potassium and selenium. Source apportionment analyses suggested the presence of four major emissions sources (sea salt, mineral dust, general combustion, and non-exhaust vehicle emissions) in the study area. Elevated levels of combustion-related elements of health concern (e.g., arsenic, cadmium, antimony, and vanadium) were observed near the waste incinerator and other industrial facilities by mobile monitoring, as well as in residential-zoned areas in Chester. These results suggest potential co-exposures to harmful atmospheric metal/metalloids in communities surrounding the Chester-Trainer-Marcus Hook industrial area at levels that may exceed previous estimates from EPA modeling.


Asunto(s)
Contaminantes Atmosféricos , Contaminación del Aire , Arsénico , Metales Pesados , Selenio , Contaminantes Atmosféricos/análisis , Contaminación del Aire/análisis , Monitoreo del Ambiente/métodos , Antimonio/análisis , Arsénico/análisis , Cadmio/análisis , Material Particulado/análisis , Polvo/análisis , Selenio/análisis , Vanadio/análisis , Aerosoles/análisis , Metalurgia , Metales Pesados/análisis
2.
Environ Sci Technol ; 55(15): 10255-10267, 2021 08 03.
Artículo en Inglés | MEDLINE | ID: mdl-34270218

RESUMEN

Detailed offline speciation of gas- and particle-phase organic compounds was conducted using gas/liquid chromatography with traditional and high-resolution mass spectrometers in a hybrid targeted/nontargeted analysis. Observations were focused on an unoccupied home and were compared to two other indoor sites. Observed gas-phase organic compounds span the volatile to semivolatile range, while functionalized organic aerosols extend from intermediate volatility to ultra-low volatility, including a mix of oxygen, nitrogen, and sulfur-containing species. Total gas-phase abundances of hydrocarbon and oxygenated gas-phase complex mixtures were elevated indoors and strongly correlated in the unoccupied home. While gas-phase concentrations of individual compounds generally decreased slightly with greater ventilation, their elevated ratios relative to controlled emissions of tracer species suggest that the dilution of gas-phase concentrations increases off-gassing from surfaces and other indoor reservoirs, with volatility-dependent responses to dynamically changing environmental factors. Indoor-outdoor emissions of gas-phase intermediate-volatility/semivolatile organic hydrocarbons from the unoccupied home averaged 6-11 mg h-1, doubling with ventilation. While the largest single-compound emissions observed were furfural (61-275 mg h-1) and acetic acid, observations spanned a wide range of individual volatile chemical products (e.g., terpenoids, glycol ethers, phthalates, other oxygenates), highlighting the abundance of long-lived reservoirs resulting from prior indoor use or materials, and their gradual transport outdoors.


Asunto(s)
Contaminantes Atmosféricos , Contaminación del Aire Interior , Compuestos Orgánicos Volátiles , Aerosoles/análisis , Contaminantes Atmosféricos/análisis , Contaminación del Aire Interior/análisis , Monitoreo del Ambiente , Cromatografía de Gases y Espectrometría de Masas , Espectrometría de Masas , Compuestos Orgánicos Volátiles/análisis
3.
Sci Adv ; 6(10): eaay4109, 2020 03.
Artículo en Inglés | MEDLINE | ID: mdl-32181345

RESUMEN

The contamination of indoor nonsmoking environments with thirdhand smoke (THS) is an important, poorly understood public health concern. Real-time THS off-gassing from smokers into a nonsmoking movie theater was observed with online and offline high-resolution mass spectrometry. Prominent emission events of THS tracers (e.g., 2,5-dimethylfuran, 2-methylfuran, and acetonitrile) and other tobacco-related volatile organic compounds (VOCs) coincided with the arrival of certain moviegoers and left residual contamination. These VOC emission events exposed occupants to the equivalent of 1 to 10 cigarettes of secondhand smoke, including multiple hazardous air pollutants (e.g., benzene and formaldehyde) at parts-per-billion concentrations. Nicotine and related intermediate-volatility nitrogen-containing compounds, which vaporized from clothes/bodies and recondensed onto aerosol, comprised 34% of observed functionalized organic aerosol abundance. Exposure to THS VOC emission events will be considerably enhanced in poorly ventilated or smaller spaces in contrast with a large, well-ventilated theater-amplifying concentrations and potential impacts on health and indoor chemistry.


Asunto(s)
Contaminación del Aire Interior/análisis , Benceno/análisis , Furanos/análisis , Nicotina/análisis , Contaminación por Humo de Tabaco/análisis , Compuestos Orgánicos Volátiles/análisis , Acetonitrilos/análisis , Acetonitrilos/química , Aerosoles , Benceno/química , Formaldehído/análisis , Formaldehído/química , Furanos/química , Alemania , Humanos , Espectrometría de Masas , Películas Cinematográficas , Nicotina/química , Compuestos Orgánicos Volátiles/clasificación
4.
Environ Sci Technol ; 53(22): 13009-13018, 2019 Nov 19.
Artículo en Inglés | MEDLINE | ID: mdl-31525033

RESUMEN

The molecular-level composition and structure of organic aerosol (OA) affect its chemical/physical properties, transformations, and impacts. Here, we use the molecular-level chemical composition of functionalized OA from three diverse field sites to evaluate the effect of molecular-level compositional variability on OA phase state and thermodynamic mixing favorability. For these ambient sites, modeled aerosol phase state ranges from liquid to semisolid. The observed variability in OA composition has some effect on resulting phase state, but other factors like the presence of inorganic ions, aerosol liquid water, and internal versus external mixing with water are determining factors in whether these particles exist as liquids, semisolids, or solids. Organic molecular composition plays a more important role in determining phase state for phase-separated (verus well-mixed) systems. Similarly, despite the observed OA compositional differences, the thermodynamic mixing favorability for OA samples with aerosol liquid water, isoprene oxidation products, or monoterpene oxidation products remains fairly consistent within each campaign. Mixing of filter-sampled OA and isoprene or monoterpene oxidation products is often favorable in both seasons, while mixing with water is generally unfavorable.


Asunto(s)
Agua , Aerosoles , Oxidación-Reducción , Estaciones del Año , Termodinámica
5.
J Chromatogr A ; 1598: 163-174, 2019 Aug 02.
Artículo en Inglés | MEDLINE | ID: mdl-30928166

RESUMEN

Complex airborne mixtures of organic compounds can contain 10,000's of diverse compounds at trace concentrations. Here, we incorporate high-resolution mass spectrometry into our integrated offline sampling-to-analysis measurement system for routine molecular-level speciation of complex mixtures in gas- or particle-phase samples with detection limits of 2-20 pg L-1 (i.e. 0.2-1.9 ppt in 6 L samples). Analytes desorbed from custom adsorbent tubes (or filter extracts) were separated via gas chromatography (GC) and simultaneously analyzed by an electron ionization quadrupole mass spectrometer (EI-MS), and by atmospheric pressure chemical ionization (APCI) combined with a high-resolution quadrupole time-of-flight mass spectrometer (Q-TOF) with a resolution of 25,000-40,000 M/ΔM in HR-TOF and MS/MS modes. We demonstrated our system with simple standards, a Macondo crude oil standard as a reference for complex mixtures of common airborne compounds, and ambient samples using GC-TOF and GC-MS/MS. We speciated complex mixtures at mass accuracy error (i.e. mass tolerance) down to 8 ± 2 ppm (e.g. resolving analytes of mass 270.000 u with 0.003 u accuracy) using a targeted approach with 3000 molecular formulas, including hydrocarbons and functionalized analytes containing oxygen, sulfur, nitrogen, or phosphorous. This extended from compounds with 10 to 32 carbon atoms and up to 16 hydrocarbon formulas per carbon number, and a similar range for functionalized compound classes. We also demonstrated our MS/MS capabilities to differentiate structural isomers and determine the presence of specific functional groups; and our direct-TOF capability, which bypasses high-temperature chromatographic separation to preserve functionalized analytes.


Asunto(s)
Mezclas Complejas/química , Gases/química , Compuestos Orgánicos/análisis , Espectrometría de Masas en Tándem , Ionización del Aire , Presión Atmosférica , Cromatografía de Gases y Espectrometría de Masas , Límite de Detección
6.
J Chromatogr A ; 1575: 80-90, 2018 Nov 09.
Artículo en Inglés | MEDLINE | ID: mdl-30292521

RESUMEN

Gas-phase organic compounds across a range of volatilities, including volatile organic compounds (VOCs), are key components of outdoor air, indoor spaces, and a variety of other anthropogenic and biogenic systems. The collection of offline samples on adsorbent-packed tubes for analysis on laboratory instrumentation has been in use for decades, but with limited sensitivities and compound coverage. We present and evaluate our integrated sampling-to-analysis system that enables offline detailed chemical characterization of multi-faceted organic mixtures at trace concentrations. Its capabilities extend across a diverse variety of VOCs with different molecular features, as well as intermediate and semivolatile organic compounds (I/SVOCs). Samples can be collected manually or via automated devices that have been applied in chamber, field, and aircraft platforms. The laboratory instrumentation can be coupled to both a high resolution mass spectrometer (MS) and a traditional quadrupole MS, though performance metrics presented in this study are determined via the traditional MS. We demonstrate capabilities for detailed chemical characterization and routine performance for a wide range of compound functionalities at sub-part per trillion (ppt) concentrations, and as low as <100 parts per quadrillion (ppq), yielding 3300 observed unique compound peaks in a single indoor air sample. These limits of detection and compound coverage were accomplished through a holistic optimization of the entire system and lifecycle of adsorbent tubes. We present our best practices for all aspects of tube production, handling, sampling, and analysis, and an examination of commercially-available materials and our custom adsorbent tubes using a diverse mix of VOC, IVOC, and SVOC standards, including difficult to measure analytes across a range of polarities and functionalities. In many aspects, the commercially-available materials and tube conditioners tested were insufficient for achieving low-ppt measurements.


Asunto(s)
Monitoreo del Ambiente/métodos , Contaminantes Ambientales/análisis , Compuestos Orgánicos Volátiles/análisis , Monitoreo del Ambiente/instrumentación
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA