Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 27
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Nanomaterials (Basel) ; 14(9)2024 Apr 23.
Artículo en Inglés | MEDLINE | ID: mdl-38727332

RESUMEN

Spectroscopy is a powerful tool to identify the specific fingerprints of analytes in a label-free way. However, conventional sensing methods face unavoidable barriers in analyzing trace-amount target molecules due to the difficulties of enhancing the broadband molecular absorption. Here, we propose a sensing scheme to achieve strong fingerprint absorption based on the angular-scanning strategy on an all-silicon metasurface. By integrating the mid-infrared and terahertz sensing units into a single metasurface, the sensor can efficiently identify 2,4-DNT with high sensitivity. The results reveal that the fingerprint peak in the enhanced fingerprint spectrum is formed by the linked envelope. It exhibits a significant enhancement factor exceeding 64-fold in the terahertz region and more than 55-fold in the mid-infrared region. Particularly, the corresponding identification limit of 2,4-DNT is 1.32 µg cm-2, respectively. Our study will provide a novel research idea in identifying trace-amount explosives and advance practical applications of absorption spectroscopy enhancement identification in civil and military security industries.

2.
Nanomaterials (Basel) ; 14(10)2024 May 19.
Artículo en Inglés | MEDLINE | ID: mdl-38786839

RESUMEN

Prohibited additives in infant formula severely affect the health of infants. Terahertz (THz) spectroscopy has enormous application potential in analyte detection due to its rich fingerprint information content. However, there is limited research on the mixtures of multiple analytes. In this study, we propose a split ring metasurface that supports magnetic dipole bound states in the continuum (BIC). By breaking the symmetry, quasi-BIC with a high quality (Q) factor can be generated. Utilizing an angle-scanning strategy, the frequency of the resonance dip can be shifted, resulting in the plotting of an envelope curve which can reflect the molecular fingerprint of the analytes. Two prohibited additives found in infant formula, melamine and vanillin, can be identified in different proportions. Furthermore, a metric similar to the resolution in chromatographic analysis is introduced and calculated to be 0.61, indicating that these two additives can be detected simultaneously. Our research provides a new solution for detecting additives in infant formula.

3.
Nanomaterials (Basel) ; 14(8)2024 Apr 19.
Artículo en Inglés | MEDLINE | ID: mdl-38668207

RESUMEN

Tightly coupled meta-atoms (TCMAs) are densely packed metamaterials with unnatural refractive indexes. Actively modulated TCMAs with tunable optical properties have found many applications in beam shaping, holography, and enhanced light-matter interactions. Typically, TCMAs are studied in the classic Bloch theory. Here, tightly coupled H-shaped meta-atoms are proposed with an ultra-high permittivity of ~6000, and their active modulation with graphene is designed by using the tightly coupled dipole array (TCDA) theory. The H-shaped meta-atoms are used as dipole arms, and the graphene strips function as the dipole loads. By tuning the chemical potential of graphene, the resonant amplitude, frequency, and permittivity are dynamically modulated. The simulations indicate that the real and imaginary parts of permittivity change from 6854 to 1522 and from 7356 to 2870, respectively. The experimental validation demonstrates a modulation depth of 11.6% in the resonant frequency, i.e., from 219.4 to 195 GHz, and a substantial 52.5% modulation depth in transmittance under a bias voltage of less than 1.5 V.

4.
Heliyon ; 9(11): e21711, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-38027853

RESUMEN

Ischemic acute kidney injury (AKI) is a prevalent disorder among hospitalized patients worldwide. Astragaloside IV (AS-IV) has been shown to protect against ischemic AKI. However, the specific effects and mechanisms of AS-IV on alleviating kidney ischemia-reperfusion (I/R) injury remain unclear. The objective of this research was to elucidate the regulatory targets and mechanisms through which AS-IV protects kidney I/R injury. A combination of network pharmacology, molecular docking, molecular dynamics (MD) simulation, pharmacodynamic study and Western blot were employed to explore the underlying mechanisms. Network pharmacology revealed that ferroptosis was a potential mechanism of AS-IV against kidney I/R injury. Molecular docking and MD simulations demonstrated strong binding affinity between the GPX4/SLC7A11 and AS-IV. The experimental verification demonstrated that AS-IV improved cell proliferation, decreased the level of ROS and Fe2+, and increased the expressions of GPX4 and SLC7A11 as same as Ferrostatin-1 in OGD/R-injured HUVECs. In conclusion, AS-IV had a significant inhibition on ferroptosis in kidney I/R injury, providing a new perspective for drug development on kidney I/R injury. Definitely, further exploration in vivo is necessary to fully understand whether AS-IV alleviates kidney I/R injury through inhibiting endothelial ferroptosis.

5.
Sensors (Basel) ; 23(20)2023 Oct 22.
Artículo en Inglés | MEDLINE | ID: mdl-37896724

RESUMEN

This paper proposes an adaptive distributed hybrid control approach to investigate the output containment tracking problem of heterogeneous wide-area networks with intermittent communication. First, a clustered network is modeled for a wide-area scenario. An aperiodic intermittent communication mechanism is exerted on the clusters such that clusters only communicate through leaders. Second, in order to remove the assumption that each follower must know the system matrix of the leaders and achieve output containment, a distributed adaptive hybrid control strategy is proposed for each agent under the internal model and adaptive estimation mechanism. Third, sufficient conditions based on average dwell-time are provided for the output containment achievement using a Lyapunov function method, from which the exponential stability of the closed-loop system is analyzed. Finally, simulation results are presented to demonstrate the effectiveness of the proposed adaptive distributed intermittent control strategy.

6.
Materials (Basel) ; 16(17)2023 Aug 24.
Artículo en Inglés | MEDLINE | ID: mdl-37687479

RESUMEN

In this paper, we propose a dual-mode frequency selective rasorber (FSR) with tunable transmission and absorption windows at the X-band, which shows a broad passband in each transmission window. The proposed tunable FSR consists of a lossy absorption layer, a lossless transmission layer, and an air gap between them. The top frequency selective surface (FSS) layer is a cross-shaped meandering line with resistors and varactors for tunable absorption, and the bottom layer is a cross-shaped gap with varactors to achieve tunable bandpass. The equivalent circuit model (ECM) is investigated, and the 3D full wave simulation is performed. The results are based on simulations, and the simulation results show that the passband can be tuned from 12 to 8 GHz with an insertion loss between 0.5 and 1.4 dB by sweeping the capacitance of the varactors. The proposed design decreases the chances of detection by adversary devices and assures spectrum-safe communication, thereby creating new avenues for radar stealth and target concealment.

7.
Nanomaterials (Basel) ; 13(13)2023 Jun 25.
Artículo en Inglés | MEDLINE | ID: mdl-37446450

RESUMEN

In this work, we demonstrate a novel structure that can generate extraordinary optical transmission with a silicon hemisphere placed on a conventional bull's eye structure. There is a single subwavelength aperture surrounded by concentric periodic grooves on a substrate. The extraordinary optical transmission in this work is realized by the coupling of the surface plasmon polaritons in the periodic grooves and the localized electromagnetic field generated by the Mie resonance in the silicon hemisphere. The maximum normalized-to-area transmission peak can reach up to 662 with a decreasing device area and size. The electromagnetic field distribution at different geometry parameters is analyzed to clarify the mechanisms of the work in this paper. Additionally, the use of dielectric material in the aperture can avoid ohmic losses of metal material compared with the conventional one, which may suggest that a wider range of bull's-eye-structure applications is possible.

8.
Front Public Health ; 10: 999095, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36203661

RESUMEN

Fluorescent lamp manufacturing workers have been extensively exposed to mercury (Hg). Our aim was to assess their health risks using several approved occupational health risk assessment methods, and to find out which method was more suitable for identification of occupational health risks. Work locations, and air and urine samples were collected from 530 exposed workers in Zhejiang, China. Based on the calculated exposure doses, health risks and risk ratios (RRs) as health risk indices, were evaluated using: Environmental Protection Agency (EPA), Australian, Romanian, Singaporean, International Council on Mining and Metals (ICMM), and Control of Substances Hazardous to Health (COSHH) methods. Among the workers, 86.0% had higher Hg levels than the Chinese occupational exposure limits of 0.02 mg/m3, and 16.7% urine samples were higher than the biological exposure limits of 35.0 µg/g·creatinine. Among workers at the injection, etc. locations, their average RRs, evaluated by the EPA, COSHH and Singaporean methods were 0.97, 0.76, and 0.60, respectively, and were significantly higher than the ICMM (0.39), Australian (0.30) and Romanian (0.29) methods. The RRs from the Singaporean method showed significant correlations with the urinary Hg levels (P < 0.01). In conclusion, the Singaporean method was more appropriate than the others for health risk evaluation because the excessive risks were significantly associated with urinary Hg levels among the workers.


Asunto(s)
Mercurio , Exposición Profesional , Salud Laboral , Australia/epidemiología , Creatinina , Humanos , Mercurio/orina , Exposición Profesional/efectos adversos , Exposición Profesional/análisis
9.
Nanoscale Adv ; 4(11): 2494-2500, 2022 May 31.
Artículo en Inglés | MEDLINE | ID: mdl-36134131

RESUMEN

By using Mie resonance coupling effects, low-loss silicon particles as receiving or transmitting antennas can strongly localize the electromagnetic field. Enhanced extraordinary optical transmission (EEOT) is generated by placing two such silicon particles symmetrically on both sides of subwavelength hole arrays in the terahertz (THz) region. When the hole radius r is 17 times smaller than the resonance wavelength λ (r/λ = 0.06), the enhancement factors of the resonator-hole and the resonator-resonator coupling structures are 154- and 629-fold compared to that of the hole-only structure, respectively. The current distribution, magnetic field and Poynting vector are numerically simulated to reveal the mechanism of the proposed structure. Moreover, the Mie resonance coupling and the induced THz EEOT can be tuned in a wide frequency range. Our results provide a reference for the miniaturization of THz systems.

10.
RSC Adv ; 12(32): 20765-20770, 2022 Jul 14.
Artículo en Inglés | MEDLINE | ID: mdl-35919140

RESUMEN

A single metamaterial (MM) is generally designed to operate in only one band, and the MMs with different dimensions of meta-atoms are required to be integrated to achieve multi-spectral responses simultaneously. In this study, an all-dielectric synthetic multi-spectral metamaterial (SMM) that can efficiently operate in the visible and terahertz (THz) ranges by incorporating nanoscale features into microscale unit cells is demonstrated and investigated numerically. The resonant frequency of the proposed SMM in both regimes can be tuned independently by changing the geometric parameters such as diameter, gap, width and height of unit cells functional in two different regions, whilst maintaining high reflectance efficiency. Results show that a variety of colors can be produced from red to purple in the visible range with maximal reflectance as high as 83% while the peak frequency of the SMM can be adjusted from 8.12 to 2.13 THz in the THz range with maximum reflectance up to 94%. The reflection characteristics of the SMM mainly originate from the electric dipole (ED) and magnetic dipole (MD) resonances via Mie scattering in both regions. The strategy of this research offers the possibility of applications in bio/chemical sensing, multi-spectral imaging, filtering, detection, modulation and so on.

11.
Molecules ; 27(4)2022 Feb 16.
Artículo en Inglés | MEDLINE | ID: mdl-35209131

RESUMEN

With the emergence of fifth-generation (5G) cellular networks, millimeter-wave (mmW) and terahertz (THz) frequencies have attracted ever-growing interest for advanced wireless applications. The traditional printed circuit board materials have become uncompetitive at such high frequencies due to their high dielectric loss and large water absorption rates. As a promising high-frequency alternative, liquid crystal polymers (LCPs) have been widely investigated for use in circuit devices, chip integration, and module packaging over the last decade due to their low loss tangent up to 1.8 THz and good hermeticity. The previous review articles have summarized the chemical properties of LCP films, flexible LCP antennas, and LCP-based antenna-in-package and system-in-package technologies for 5G applications, although these articles did not discuss synthetic LCP technologies. In addition to wireless applications, the attractive mechanical, chemical, and thermal properties of LCP films enable interesting applications in micro-electro-mechanical systems (MEMS), biomedical electronics, and microfluidics, which have not been summarized to date. Here, a comprehensive review of flexible LCP technologies covering electric circuits, antennas, integration and packaging technologies, front-end modules, MEMS, biomedical devices, and microfluidics from microwave to THz frequencies is presented for the first time, which gives a broad introduction for those outside or just entering the field and provides perspective and breadth for those who are well established in the field.

12.
ACS Omega ; 6(44): 29746-29751, 2021 Nov 09.
Artículo en Inglés | MEDLINE | ID: mdl-34778646

RESUMEN

Tunable extraordinary optical transmission (EOT) with graphene is realized using a novel metallic ring-rod nested structure in the terahertz frequency regime. The generated double-enhanced transmission peaks primarily originate from the excitation of localized surface plasmon resonances (LSPRs). On using graphene, the resonating surface plasmon distribution changes in the reaction plane, which disturbs the generation of LSPRs. By regulating the Fermi energy (E f) of the graphene to reach a certain level, an adjustment from bimodal EOT to unimodal EOT is obtained. As the E f of the graphene integrated beneath the rod increases to 0.5 eV, the transmittance of the peak at 2.42 THz decreases to 6%. Moreover, the transmission peak at 1.77 THz virtually disappears due to the E f increasing to 0.7 eV when the graphene is placed beneath the ring. The significant tuning capabilities of the bimodal EOT indicate its promising application prospects in frequency-selective surfaces, communication, filtering, and radar.

13.
Bioanalysis ; 13(20): 1569-1584, 2021 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-34696600

RESUMEN

Quantification of hippuric acid and methylhippuric acid in human urine matrices provides information on the toluene and xylene exposure conditions. High performance liquid chromatography coupled with UV detection is the preferable technique for hippuric acid and methylhippuric acid detection in human urine. This study was conducted to present analytical techniques developed for monitoring of hippuric acid and methylhippuric acid in human urine matrices during 2016-2021.


Asunto(s)
Hipuratos
14.
Viral Immunol ; 34(8): 522-530, 2021 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-34550784

RESUMEN

Rabies is an almost invariably fatal disease. According to the World Health Organization (WHO), rabies virus neutralizing antibody (RVNA) titers of ≥0.5 IU/mL are considered adequate for rabies protection. Therefore, detection and quantification of RABV antibodies are important. Many methods have been developed for detecting RABV antibodies. In the present study, we reviewed several methods of detecting RABV antibodies in human and animal samples and evaluated and compared their performance. Of 34 methods, 5 demonstrated unsatisfactory sensitivity or specificity. The others exhibited sensitivity and specificity of ≥75%. The correlation coefficient for five of eight methods was >0.8. The Bland-Altman mean bias of five of five methods was <±2.0. The kappa values of 25 of 28 methods were higher than 0.4, demonstrating at least moderate agreement. Analysis of the performance of these methods emphasized that any new technology should be considered carefully and objectively before being used as an appropriate and applicable alternative.


Asunto(s)
Virus de la Rabia , Rabia , Animales , Anticuerpos Neutralizantes , Anticuerpos Antivirales , Pruebas de Neutralización/métodos , Rabia/prevención & control
15.
J Mol Recognit ; 34(11): e2930, 2021 11.
Artículo en Inglés | MEDLINE | ID: mdl-34432338

RESUMEN

In this study, magnetic molecularly imprinted polymers (MMIPs) were prepared and used as sorbents for extraction of S-phenylmercapturic acid (S-PMA) from urine samples, followed by high-performance liquid chromatography ultraviolet-visible (HPLC-UV/Vis) analysis. The MMIPs were synthesized by the copolymerization reaction of (phenylthio) acetic acid (template molecule), methacrylic acid (functional monomers) and ethylene glycol dimethacrylate (cross-linkers). The morphology, structure property and surface groups of the prepared MMIPs were characterized by scan electron microscopy, transmission electron microscopy, infrared spectroscopy, X-ray diffraction pattern, thermogravimetric analyses, Brunauer-Emmett-Teller and vibrating sample magnetometer. The selectivity of the MMIPs was investigated in the presence of interferents. Various parameters affecting the S-PMA extraction efficiency were investigated, including MMIPs amount, pH, sample volume, desorption solvent, as well as extraction and desorption time. The obtained optimal parameters were as follows: MMIPs amount (20 mg), pH (3.0), sample volume (5 mL), desorption solvent (methanol/acetic acid [9/1, v/v]), extraction time (30 minutes) and desorption time (2 minutes). The method was validated according to the Food and Drug Administration Guidance for Industry on Bioanalytical Method Validation. The calibration curve for the analyte was linear in the concentration range of 0.030-1.0 mg/L (r = 0.9995). The LOD and LOQ of the method were 0.0080 and 0.0267 mg/L, respectively. The enrichment factor of the MMIPs was 5. The relative standard deviations of intra- and inter-day tests were in the range of 3.8-5.1% and 3.9-6.3%, respectively. The recoveries at three different concentrations of 0.10, 0.50 and 0.80 mg/L ranged between 95.2% and 98.6%. In addition, the MMIPs could be reused for at least eight times. The proposed method was successfully applied to the determination of S-PMA in urine samples. In addition, this developed method could be used as a tool in the early screening and clinical diagnosis of benzene intoxication.


Asunto(s)
Acetilcisteína/análogos & derivados , Cromatografía Líquida de Alta Presión/métodos , Nanopartículas de Magnetita/química , Polímeros Impresos Molecularmente/química , Extracción en Fase Sólida/métodos , Orina/química , Acetilcisteína/aislamiento & purificación , Acetilcisteína/orina , Humanos
16.
ACS Omega ; 6(6): 4480-4484, 2021 Feb 16.
Artículo en Inglés | MEDLINE | ID: mdl-33644557

RESUMEN

In this work, an analogue of electromagnetically induced transparency (EIT) is excited by a periodic unit consisting of a silicon rectangular bar resonator and a silicon ring resonator in terahertz (THz). The analogue of the EIT effect can be well excited by coupling of the "bright mode" and the "dark mode" supported by the bar and the ring, respectively. Using the semimetallic properties of graphene, active control of the EIT-like effect can be realized by integrating a monolayer graphene into THz metamaterials. By adjusting the Fermi energy of graphene, the resonating electron distribution changes in the dielectric structures, resulting in the varying of the EIT-like effect. The transmission can be modulated from 0.9 to 0.3 with the Fermi energy of graphene placed under the ring resonator mold varying from 0 to 0.6 eV, while a modulation range of 0.9-0.3 corresponds to Fermi energy from 0 to 0.3 eV when graphene is placed under the rectangular bar resonator. Our results may provide potential applications in slow light devices and an ultrafast optical signal.

17.
J Nanosci Nanotechnol ; 21(3): 1439-1445, 2021 03 01.
Artículo en Inglés | MEDLINE | ID: mdl-33404406

RESUMEN

Herein, a facile and low-cost method for the preparation of activated carbon from peanut shell was developed for the first time for the fast extraction and determination of Bisphenol A in human urine. Bisphenol A was separated by EC-C18 column (250 mm×4.6 mm, 4 µm) and was detected by VWD, with retention time for qualitative analysis and peak area for quantitation. The parameters, pH values of the urine, adsorbent dose, adsorption time and so on, were optimized to achieve the excellent extraction performance. The detection limit of Bisphenol A in human urine was 1.0 ng · mL-1 (S/N = 3), and the standard curve was linear in the range of 5.0 ng · mL-1˜200.0 ng · mL-1 (r = 0.9993). The average recovery of Bisphenol A was 78.5˜96.2% at three spiked levels in the range of 5.00 ng · mL-1˜200.00 ng·mL-1. The method was proved simple, practical and highly sensitive, which could satisfy the request for the determination of Bisphenol A in human urine.


Asunto(s)
Arachis , Carbón Orgánico , Compuestos de Bencidrilo , Cromatografía Líquida de Alta Presión , Humanos , Fenoles
18.
Nanoscale Adv ; 3(14): 4072-4078, 2021 Jul 13.
Artículo en Inglés | MEDLINE | ID: mdl-36132834

RESUMEN

A kind of near-perfect metamaterial absorber, made of only Au and Si, has been presented in the terahertz band with extremely high absorptance. A flexible design method is proposed, which could create absorbers with four independent functions as follows. First, selective perfect absorption is achieved at a single frequency, which means the absorptance is more than 99.9% at the required frequency and almost 0% at adjacent frequencies. Second, nearly 100% perfect absorption is realized at more frequencies, which can be changed by simply adjusting the geometric parameters. Third, broadband absorption with a controllable band is gained, and the average absorptance exceeds 99% from 1.2 to 2 THz. Finally, the combination of single-frequency absorption and broadband absorption is accomplished, which greatly expands the application prospects of the proposed absorber. Besides, the absorber exhibits high performance over a wide range of incident angles from 0° to 60°. Meanwhile, it is insensitive to both TE and TM waves. The aforementioned design idea can be extended to other bands.

19.
Biomed Chromatogr ; 34(7): e4834, 2020 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-32203622

RESUMEN

In this study, activated carbon/diatomite-based magnetic nancomposites (denoted as AC/DBMNs) were synthesized and applied as an adsorbent for magnetic solid-phase extraction of S-phenylmercapturic acid (S-PMA) from human urine prior to high-performance liquid chromatography. The surface morphologies and structures of AC/DBMNs were characterized by Fourier transform infrared spectroscopy, transmission and scanning electron microscopy, X-ray diffraction, Brunauer-Emmett-Teller surface area, vibrating sample magnetometer and ζ-potential measurements. The experimental parameters including sample volume, sample pH, adsorbent amount, extraction time, elution solvent and desorption time were investigated in detail. Under the optimum conditions, the method exhibited good linearity (r > 0.9993) within the concentration ranges of 0.03-1.0 mg/L. Moreover, the limits of detection and quantification were 0.01 and 0.03 mg/L, respectively. The enrichment factor was 5, and good recoveries (88.9-97.3%) with relative standard deviations in the range of 5.6-6.8% (n = 6) for inter-day and 6.3-8.1% (n = 6) for intra-day were achieved. The developed method was successfully applied to the analysis of S-PMA in urine samples. In addition, this accurate and sensitive method has great potential to be applied in the early screening and clinical diagnosis of the workers exposed to benzene.


Asunto(s)
Acetilcisteína/análogos & derivados , Carbón Orgánico/química , Tierra de Diatomeas/química , Nanopartículas de Magnetita/química , Extracción en Fase Sólida/métodos , Acetilcisteína/aislamiento & purificación , Acetilcisteína/orina , Humanos , Límite de Detección , Modelos Lineales , Nanocompuestos/química , Reproducibilidad de los Resultados
20.
ACS Omega ; 5(6): 3000-3005, 2020 Feb 18.
Artículo en Inglés | MEDLINE | ID: mdl-32095723

RESUMEN

In this work, we propose using periodic Au nanoparticles (NPs) in indium selenide-based optoelectronic devices to tune the optical absorption of indium selenide. Electromagnetic simulations show that optical absorption of indium selenide can be manipulated by tuning plasmonic resonance. The effect on the plasmonic resonance of the size, period of NPs, the thickness of silicon oxide, and the insulator spacer is systematically analyzed. A high absorption enhancement over the visible spectrum is achieved through systematic optimization of nanostructures.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...