Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Más filtros










Intervalo de año de publicación
1.
Artículo en Chino | WPRIM (Pacífico Occidental) | ID: wpr-1009220

RESUMEN

OBJECTIVE@#To observe the cage subsidence after oblique lateral interbody fusion (OLIF) for lumbar spondylosis, summarize the characteristics of the cage subsidence, analyze causes, and propose preventive measures.@*METHODS@#The data of 144 patients of lumbar spine lesions admitted to our hospital from October 2015 to December 2018 were retrospectively analyzed. There were 43 males and 101 females, and the age ranged from 20 to 81 years old, with an average of (60.90±10.06) years old. Disease types:17 patients of lumbar intervertebral disc degenerative disease, 12 patients of giant lumbar disc herniation, 5 patients of discogenic low back pain, 33 patients of lumbar spinal stenosis, 26 patients of lumbar degenerative spondylolisthesis, 28 patients of lumbar spondylolisthesis with spondylolisthesis, 11 patients of adjacent vertebral disease after lumbar internal fixation, 7 patients of primary spondylitis in the inflammatory outcome stage, and 5 patients of lumbar degenerative scoliosis. Preoperative dual-energy X-ray bone mineral density examination showed 57 patients of osteopenia or osteoporosis, and 87 patients of normal bone density. The number of fusion segments:124 patients of single-segment, 11 patients of two-segment, 8 patients of three-segment, four-segment 1 patient. There were 40 patients treated by stand-alone OLIF, and 104 patients by OLIF combined with posterior pedicle screw. Observed the occurrence of fusion cage settlement after operation, conducted monofactor analysis on possible risk factors, and observed the influence of fusion cage settlement on clinical results.@*RESULTS@#All operations were successfully completed, the median operation time was 99 min, and the median intraoperative blood loss was 106 ml. Intraoperative endplate injury occurred in 30 patients and vertebral fracture occurred in 5 patients. The mean follow-up was (14.57±7.14) months from 6 to 30 months. During the follow-up, except for the patients of primary lumbar interstitial inflammation and some patients of lumbar spondylolisthesis with spondylolisthesis, the others all had different degrees of cage subsidence. Cage subsidence classification:119 patients were normal subsidence, and 25 patients were abnormal subsidence (23 patients were gradeⅠ, and 2 patients were gradeⅡ). There was no loosening or rupture of the pedicle screw system. The height of the intervertebral space recovered from the preoperative average (9.48±1.84) mm to the postoperative average (12.65±2.03) mm, and the average (10.51±1.81) mm at the last follow-up. There were statistical differences between postoperative and preoperative, and between the last follow-up and postoperative. The interbody fusion rate was 94.4%. The low back pain VAS decreased from the preoperative average (6.55±2.2 9) to the last follow-up (1.40±0.82), and there was statistically significant different. The leg pain VAS decreased from the preoperative average (4.72±1.49) to the final follow-up (0.60±0.03), and the difference was statistically significant (t=9.13, P<0.000 1). The ODI index recovered from the preoperative average (38.50±6.98)% to the latest follow-up (11.30±3.27)%, and there was statistically significant different. The complication rate was 31.3%(45/144), and the reoperation rate was 9.72%(14/144). Among them, 8 patients were reoperated due to fusion cage subsidence or displacement, accounting for 57.14%(8/14) of reoperation. The fusion cage subsidence in this group had obvious characteristics. The monofactor analysis showed that the number of abnormal subsidence patients in the osteopenia or osteoporosis group, Stand-alone OLIF group, 2 or more segments fusion group, and endplate injury group was higher than that in the normal bone mass group, OLIF combined with pedicle screw fixation group, single segment fusion group, and no endplate injury group, and the comparison had statistical differences.@*CONCLUSION@#Cage subsidence is a common phenomenon after OLIF surgery. Preoperative osteopenia or osteoporosis, Stand-alone OLIF, 2 or more segments of fusion and intraoperative endplate injury may be important factors for postoperative fusion cage subsidence. Although there is no significant correlation between the degree of cage subsidence and clinical symptoms, there is a risk of cage migration, and prevention needs to be strengthened to reduce serious complications caused by fusion of cage subsidence, including reoperation.


Asunto(s)
Masculino , Femenino , Humanos , Adulto Joven , Adulto , Persona de Mediana Edad , Anciano , Anciano de 80 o más Años , Espondilolistesis/cirugía , Estudios Retrospectivos , Dolor de la Región Lumbar/etiología , Escoliosis , Vértebras Lumbares/cirugía , Fusión Vertebral/métodos , Enfermedades Óseas Metabólicas , Osteoporosis/etiología , Resultado del Tratamiento , Desplazamiento del Disco Intervertebral , Degeneración del Disco Intervertebral
2.
Artículo en Chino | WPRIM (Pacífico Occidental) | ID: wpr-970815

RESUMEN

OBJECTIVE@#To explore the feasibility and clinical effect of Stand-alone oblique lateral interbody fusion (OLIF) in the treatment of lumbar intervertebral disc degeneration with Modic changes and endplate sclerosis.@*METHODS@#A retrospective analysis was performed on 16 cases with lumbar intervertebral disc degeneration with Modic changes and endplate sclerosis admitted to three medical centers from January 2015 to December 2018. There were 6 males and 10 females, the age ranged from 45 to 67 years old with an average of (55.48±8.07) years old, the medical history ranged from 36 to 240 months with an average of (82.40±47.68) months. The lesion sites included L2,3 in 2 cases, L3,4 in 5 cases, and L4,5 in 9 cases. All patients presented with chronic low back pain with lower limb neurological symptoms in 3 cases. All patients were treated by Stand-alone oblique lateral lumbar interbody fusion. Clinical and radiological findings and complications were observed.@*RESULTS@#There was no vascular injury, endplate injury and vertebral fracture during the operation. The mean incision length, operation time, and intraoperative blood loss were(4.06±0.42) cm, (45.12±5.43) min, (33.40±7.29) ml, respectively. The mean visual analogue scale (VAS) of the incision pain was (1.14±0.47) at 72 hours after operation. There was no incision skin necrosis, poor incision healing or infection in patients. Sympathetic chain injury occurred in 1 case, anterolateral pain and numbness of the left thigh in 2 cases, and weakness of the left iliopsoas muscle in 1 case, all of which were transient injuries with a complication rate of 25%(4/16). All 16 patients were followed up from 12 to 36 months with an average of (20.80±5.46) months. The intervertebral space height was significantly recovered after operation, with slight lost during the follow-up. Coronal and sagittal balance of the lumbar spine showed good improvement at the final follow-up. There was no obvious subsidence or displacement of the cage, and the interbody fusion was obtained. At the final follow-up, Japanese Orthopaedic Association(JOA) score and Oswestry disability index(ODI) were significantly improved.@*CONCLUSION@#As long as the selection of case is strict enough and the preoperative examination is sufficients, the use of Stand-alone OLIF in the treatment of lumbar intervertebral disc degeneration with Modic changes and endplate sclerosis has a good results, with obvious clinical advantages and is a better surgical choice.


Asunto(s)
Masculino , Femenino , Humanos , Preescolar , Degeneración del Disco Intervertebral/cirugía , Estudios Retrospectivos , Esclerosis , Resultado del Tratamiento , Vértebras Lumbares/cirugía , Fusión Vertebral/métodos
3.
Artículo en Chino | WPRIM (Pacífico Occidental) | ID: wpr-981706

RESUMEN

OBJECTIVE@#To analyze the causes of vertebral fracture during oblique lateral interbody fusion in the treatment of lumbar spondylopathy, summarize the clinical results, and propose preventive measures.@*METHODS@#Retrospective analysis was made on the data of 8 cases of lumbar spondylopathy and vertebral fracture treated by oblique lateral interbody fusion in three medical centers from October 2014 to December 2018. All were female, aged from 50 to 81 years with an average of 66.4 years. Disease types included 1 case of lumbar degenerative disease, 3 cases of lumbar spinal stenosis, 2 cases of lumbar degenerative spondylolisthesis and 2 cases of lumbar degenerative scoliosis. Preoperative dual energy X-ray bone mineral density test showed that 2 cases had T-value >-1 SD, 2 cases had T-value -1 to -2.5 SD, and 4 cases had T-value <-2.5 SD. Single segment fusion was in 5 cases, two segment fusion in 1 case and three segment fusion in 2 cases. Four cases were treated with OLIF Stand-alone and 4 cases were treated with OLIF combined with posterior pedicle screw fixation. Postoperative imaging examination showed vertebral fracture, and all of them were single vertebral fracture. There were 2 cases of right lower edge fracture of upper vertebral body at fusion segment, 6 cases of lower vertebral body fracture at fusion segment, and 6 cases with endplate injury and fusion cage partially embedded in vertebral body. Three cases of OLIF Stand-alone were treated with pedicle screw fixation via posterior intermuscular approach, while one case of OLIF Stand-alone and four cases of OLIF combined with posterior pedicle screw fixation were not treated specially.@*RESULTS@#The 5 cases of initial operation and 3 cases of reoperation did not show wound skin necrosis or wound infection. The follow-up time was from 12 to 48 months with an average of 22.8 months. Visual analogue scale (VAS) of low back pain was preoperative decreased from 4 to 8 points (averagely 6.3 points) and postoperative 1 to 3 points (averagely 1.7 points) at the final follow-up. Oswestry disability index (ODI) was preoperative 39.7% to 52.4% (averagely 40.2%), and postoperative 7.9% to 11.2% (averagely 9.5%) at the final follow-up. During the follow-up, there was no loosening or fracture of the pedicle screw system, and no lateral displacement of the fusion cage;however, the fusion cage at the vertebral fracture segment had obvious subsidence. The intervertebral space height of vertebral fracture segment was preoperaive 6.7 to 9.2 mm (averagely 8.1 mm), and postoperative 10.5 to 12.8 mm (averagely 11.2 mm). The improvement rate after operation was 37.98% compared to preoperative. The intervertebral space height at final follow-up was 8.4 to 10.9 mm (averagely 9.3 mm), and the loss rate was 16.71% compared with that after operation. At the final follow-up, interbody fusion was achieved in all cases except for one that could not be identified.@*CONCLUSION@#The incidence of vertebral fracture during oblique lateral interbody fusion in the treatment of lumbar spondylopathy is lower, and there are many reasons for fracture, including preoperative bone loss or osteoporosis, endplate injury, irregular shape of endplate, excessive selection of fusion cage, and osteophyte hyperplasia at the affected segment. As long as vertebral fracture is found in time and handled properly, the prognosis is well. However, it still needs to strengthen prevention.


Asunto(s)
Humanos , Femenino , Masculino , Fracturas de la Columna Vertebral/cirugía , Estudios Retrospectivos , Resultado del Tratamiento , Vértebras Lumbares/cirugía , Espondilolistesis/cirugía , Escoliosis , Fusión Vertebral/métodos
4.
Inorg Chem ; 61(40): 15921-15935, 2022 Oct 10.
Artículo en Inglés | MEDLINE | ID: mdl-36170648

RESUMEN

Chiral drugs are of great significance in drug development and life science because one pair of enantiomers has a different combination mode with target biological active sites, leading to a vast difference in physical activity. Metal-organic framework (MOF)-based chiral hybrid materials with specific chiral sites have excellent applications in the highly effective sensing of drug enantiomers. Sitagliptin and clonidine are effective curing drugs for controlling diabetes and hypertension, while insulin and norepinephrine are the biomarkers of these two diseases. Excessive use of sitagliptin and clonidine can cause side effects such as stomach pain, nausea, and headaches. Herein, through post-synthetic strategy, MOF-based chiral hybrid material Eu-BTB@d-carnitine (H3BTB = 1,3,5-benzenetrisbenzoic acid) was synthesized. Eu-BTB@d-carnitine has dual emission peaks at 417 and 616 nm when excited at 330 nm. Eu-BTB@d-carnitine can be applied in luminescent recognition toward sitagliptin and clonidine with high sensitivity and low detection limit (for sitagliptin detection, Ksv is 7.43 × 106 [M-1]; for clonidine detection, Ksv is 9.09 × 106 [M-1]; limit of detection (LOD) for sitagliptin is 10.21 nM, and LOD of clonidine is 8.34 nM). In addition, Eu-BTB@d-carnitine can further realize highly sensitive detection of insulin in human fluids with a high Ksv (2.08 × 106 [M-1]) and a low LOD (15.48 nM). On the other hand, norepinephrine also can be successfully discriminated by the hybrid luminescent platform of Eu-BTB@d-carnitine and clonidine with a high Ksv value of 4.79 × 106 [M-1] and a low LOD of 8.37 nM. As a result, the chiral hybrid material Eu-BTB@d-carnitine can be successfully applied in the highly effective ratiometric sensing of curing drugs and biomarkers for diabetes and hypertension.


Asunto(s)
Diabetes Mellitus , Hipertensión , Insulinas , Estructuras Metalorgánicas , Biomarcadores , Carnitina , Clonidina , Europio/química , Humanos , Estructuras Metalorgánicas/química , Norepinefrina , Fosfato de Sitagliptina
5.
Spectrochim Acta A Mol Biomol Spectrosc ; 254: 119655, 2021 Jun 05.
Artículo en Inglés | MEDLINE | ID: mdl-33744702

RESUMEN

Metal-organic framework (MOFs), also known as porous coordination polymers (PCPs), is a new kind of crystalline porous materials, which has received extensive attention in the past few decades. As a new type of sensing material, MOFs stand out from many other traditional fluorescence sensors because of its crystal characteristics, structural diversity, stable porosity and adjustable functional characteristics. In this work, the bi-functional building block containing aromatic carboxylic acid and triazole moieties, namely 3-(1H-1,3,4-triazol-1-yl) benzoic acid, was selected as the linker to synthesize {[Cd(µ5-L)⋅I}n (1, HL = 3-(1H-1,3,4-triazol-1-yl)benzoic acid) by hydrothermal method with transition CdII metal centers. Firstly, the preliminary characterization of 1 was carried out by means of PXRD, FT-IR, and then the UV and fluorescence tests were conducted to study the fluorescence properties of 1. The crystal structure analysis indicates that CdII is the center and the ligand is bridged to form a two-dimensional porous structure. In addition, 1 has good selectivity for Fe3+ and Cr2O72-, meanwhile, it has high detection sensitivity (Ksv quenching efficiency for Fe3+: 1.2 × 104 M-1 and Cr2O72- 1.85 × 104 M-1) and low detection limit (Fe3+: 19.21 µM and Cr2O72-: 12.46 µM). The results of photoluminescence test show that 1 can detect cations and anions with high sensitivity, resist the interference of other ions, and have good reusability. As far as we know, 1 is the first example of ultra-stable two-dimensional (2D) Cadmium (II) microporous coordination material as a fluorescence sensor for Fe3+ and Cr2O72-.

6.
Spectrochim Acta A Mol Biomol Spectrosc ; 249: 119214, 2021 Mar 15.
Artículo en Inglés | MEDLINE | ID: mdl-33257240

RESUMEN

In industry, over usage of Cu2+ and Al3+ will lead to toxic wastewater, which further to give serious pollution for the environment. On the other hand, L-lysine can enhance serotonin release in the amygdala, with subsequent changes in psychobehavioral responses to stress. Therefore it is the urgent problem to design a method for detecting the amount of Cu2+, Al3+, and L-lysine. In this work, through the solvothermal synthesis method, two new coordination complexes based on the new bifunctional building block 4'-(1H-1,2,4-triazole-1-yl)- [1,1'-biphenyl]-4-carboxylic acid (HL) have been synthesized, namely, [Zn(L)2·4H2O] (complex 1) and [Cd(L)2·4H2O] (complex 2). X-ray single-crystal diffractometer was used to analyze its structure, powder X-ray diffraction (PXRD) patterns confirmed that 1 and 2 powder's purity and 1 can keep stable during the detection process of Cu2+, Al3+, and L-lysine, respectively. Elemental analysis, thermogravimetric analysis, infrared analysis, ultraviolet analysis and fluorescent spectrum have been used to characterize these complexes. The photo-luminescent test showed that 1 can accurately recognize Al3+ and Cu2+ among various cations. On the other hand, 1 can distinguish L-lysine among amino acid molecules. Therefore, 1 can be utilized as a multifunctional fluorescent probe for Al3+(Ksv = 1.5570 × 104 [M]-1), Cu2+(Ksv = 1.4948 × 104 [M]-1) and L-lysine (Ksv = 4.9118 × 104 [M]-1) with low detection limits (17.5 µM, 18.2 µM, 5.6 µM) respectively.


Asunto(s)
Complejos de Coordinación , Cadmio , Cobre , Cristalografía por Rayos X , Lisina , Zinc
7.
Spectrochim Acta A Mol Biomol Spectrosc ; 247: 119092, 2021 Feb 15.
Artículo en Inglés | MEDLINE | ID: mdl-33120122

RESUMEN

In recent years, a new type of micro-porous material, namely metal organic framework material, has received more and more attention from many basic and industrial fields because these materials possess unique advantages. In this work, through the powerful sonochemical preparation method, a three-dimensional cluster-based CdII-MOFs, {[Cd(abtz)2(H2O)2]·(ClO4)2·H2O}n (1, abtz = 1-(4-aminobenzyl)-1H-1,2,4-triazole) can be quickly synthesized in the facile ultrasonic method. Powder X-ray diffraction (PXRD) measurement confirms that these bulky samples 1 (synthesized on different ultrasonic powers and ultrasonic time conditions) were pure. In addition, ultrasonic chemical time and irradiation power did not change the structure of composites materials 1. SEM and morphological changes of 1 in the ultrasonic synthesis are also determined. Moreover, 1 exhibits good stability, the structure of 1 can be maintained not just in various solvents, and in aqueous environments with pH values from 2 to 12. Photo-luminescent experiment also reveals that complex 1 has the excellent application prospect as highly sensitive sensing material for the biomarker DPA (2,6-pyridine dicarboxylic acid) and 5-HT (5-hydroxytryptamine) through the photo-luminescence "turn-on" and "turn-off" effect, respectively. Further photo-luminescent measurements also show that different ultrasonic powers and ultrasonic time can effectively induce fluorescent sensing enhancement for biomarkers DPA and 5-HT based on the water stable clustered-based cadmium(II) coordination framework.


Asunto(s)
Biomarcadores , Cadmio , Serotonina , Ultrasonido , Biomarcadores/análisis , Serotonina/análisis , Agua
8.
Artículo en Chino | WPRIM (Pacífico Occidental) | ID: wpr-879434

RESUMEN

OBJECTIVE@#To explore the clinical value and safety of unilateral pedicle screw fixation combined with contralateral translaminar facet screw fixation and interbody fusion by muscle-splitting approach treatment of recurrent lumbar disc herniation.@*METHODS@#The clinical data of 51 patients with recurrent lumbar disc herniation treated from June 2012 to December 2017 were retrospectively analyzed. There were 32 males and 19 females, aged 34 to 64 years with an average of (51.11± 7.28) years. Lesions invoved L@*RESULTS@#There was no statistical difference in operation time between two groups (@*CONCLUSION@#Muscle-splitting approach is feasible for thetreatment of recurrent lumbar disc herniation with pedicle screw fixation combined with contralateral translaminar facet screw fixation and interbody fusion. Compared with the median incision approach, the muscle-splitting approach has the advantages of small incision, less trauma, less bleeding, rapid recovery. Also it can protect multifidus and do not increase the incidence of serious complications. Thus, it can be used as a choice for fixation and fusion of recurrent lumbar disc herniation.


Asunto(s)
Adulto , Femenino , Humanos , Masculino , Persona de Mediana Edad , Degeneración del Disco Intervertebral , Desplazamiento del Disco Intervertebral/cirugía , Vértebras Lumbares/cirugía , Músculos , Tornillos Pediculares , Estudios Retrospectivos , Fusión Vertebral , Resultado del Tratamiento
9.
Artículo en Chino | WPRIM (Pacífico Occidental) | ID: wpr-879369

RESUMEN

OBJECTIVE@#To analyze the causes of vascular injury occurred in oblique lateral interbody fusion for treating lumbar degenerative diseases, and put forward preventive measures.@*METHODS@#There were 235 patients analyzed from October 2014 to May 2017 in five hospitals, who were treated with oblique lateral interbody fusion with or without posterior pedicle screw fixation. There were 79 males and 156 females with an average age of (61.9±13.5) years old (ranged from 32 to 83 years). There were 7 cases of vascular injury, including 4 cases of segmental vessel injury, 1 case of left common iliac artery injury, 1 case of left common iliac veininjury and 1 case of ovarian vein injury.@*RESULTS@#The follow up time ranged from 6 to 36 months, averagely (15.6±7.5) months. There was no pedicle screw loosen or fracture. The low back pain VAS decreased from preoperative 6.7±2.3 to 1.4±0.8 at the latest follow-up, which was statistically difference(@*CONCLUSION@#Oblique lateral interbody fusion technique provides a new method for minimally invasive fusion of lumbar internal fixation. However, it has a risk of vascular injury. In order to effectively prevent the occurrence of vascular injury, the operative indications and careful and meticulous operation should be strictly grasped.


Asunto(s)
Adulto , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Persona de Mediana Edad , Vértebras Lumbares/cirugía , Región Lumbosacra , Tornillos Pediculares , Estudios Retrospectivos , Fusión Vertebral/efectos adversos , Resultado del Tratamiento , Lesiones del Sistema Vascular/cirugía
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...