Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Cardiovasc Interv Ther ; 38(1): 96-103, 2023 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-35943717

RESUMEN

Percutaneous coronary intervention (PCI) requires multiple staff members, including interventional cardiologists, with the physical burden of heavy protective measures to minimize radiation exposure. Here, we aimed to investigate the safety of task sharing with clinical engineers (CEs) working as 1st assistant during ad hoc PCI. We retrospectively included 286 patients who underwent ad hoc PCI following diagnostic catheterization for coronary artery disease between April 2019 and March 2021. Procedural complications including coronary perforation or rupture, myocardial infarction, cerebral embolism, cardiovascular death, decreased kidney function, and radiation parameters were compared between the two clinical settings [CE group, CEs as the 1st assistant from the beginning of diagnostic coronary angiography to the end of PCI vs. doctor (DR) group, others]. There was no increase in the ratio of procedural complications in the CE group (1.7%) versus the DR group (1.2%). Fluorescence time and radiation exposure dose were significantly reduced in the CE group {25 min [interquartile range (IQR), 19-35 min] vs. 28 min (IQR, 20-39 min), P = 0.036; 908 mGy (IQR, 654-1326 mGy) vs. 1062 mGy (IQR, 732-1594 mGy), P = 0.049}. The median amount of contrast medium was significantly reduced in the CE group [100 mL (IQR, 80-119 mL) vs. 110 mL (IQR 90-140 mL), P < 0.001]. After propensity matching, fluorescence time, radiation exposure dose, and contrast medium amount were similar between groups. Task sharing with CEs as the 1st assistant during ad hoc PCI could contribute to clinical safety in patients with coronary artery disease.


Asunto(s)
Enfermedad de la Arteria Coronaria , Infarto del Miocardio , Intervención Coronaria Percutánea , Humanos , Enfermedad de la Arteria Coronaria/diagnóstico , Enfermedad de la Arteria Coronaria/cirugía , Intervención Coronaria Percutánea/efectos adversos , Estudios Retrospectivos , Angiografía Coronaria/efectos adversos , Medios de Contraste , Resultado del Tratamiento , Factores de Riesgo
2.
Heart Vessels ; 37(3): 476-488, 2022 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-34432100

RESUMEN

P-wave morphology reflects atrial remodeling and indicates prognosis after radiofrequency catheter ablation (RFCA) for atrial fibrillation (AF). The impact of p-wave morphology after excluding the effect of pulmonary vein (PV) substrate on outcomes is unknown. We evaluated the p-wave morphology on electrocardiography immediately after PV isolation for clinical outcomes. Eighty-four consecutive patients (47 with paroxysmal AF and 37 with persistent AF) who underwent RFCA were included. P-wave duration (PWD) and amplitude in all leads were examined during sinus rhythm immediately after PV isolation. We evaluated the relationship between electrocardiogram parameters and AF recurrence, according to the type of AF and following ablation, and the correlation with left atrial (LA) volume, low voltage ratio, and fixed conduction time. During 12 months of follow-up, 20 patients experienced recurrence. The cut-off value of PWD > 120 ms in lead I showed a sensitivity of 75% and specificity of 69% for predicting recurrence. PWD was significantly correlated with LA volume, low voltage, and conduction velocity. Significantly higher recurrence rates were observed in patients with PWD > 120 ms than in those with PWD ≤ 120 ms (p < 0.001), and the difference was more pronounced in patients with persistent AF. Multivariate analysis demonstrated that PWD > 120 ms was independently associated with recurrence in the total population (hazard ratio 2.00; 95% confidence interval 1.27-3.22; p = 0.003) and in patients with persistent AF. In conclusion, long PWD after PV isolation predicts AF recurrence, which might be associated with the extent of the LA substrate in persistent AF.


Asunto(s)
Fibrilación Atrial , Remodelación Atrial , Ablación por Catéter , Venas Pulmonares , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/etiología , Fibrilación Atrial/cirugía , Ablación por Catéter/efectos adversos , Electrocardiografía , Humanos , Venas Pulmonares/cirugía , Recurrencia , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...