Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
Transfus Med ; 29(6): 381-388, 2019 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-31576629

RESUMEN

OBJECTIVES: We hypothesised that there was inappropriate group AB plasma used in our hospital, identifiable by a novel key quality indicator (KQI) and mitigable through massive transfusion protocol (MTP) modification. BACKGROUND: Group AB plasma is a scarce resource strained by increasing usage worldwide when used as universal donor plasma in non-group AB patients. To reduce inappropriate use and to promote benchmarking to the best practice, we developed the AB plasma appropriateness index (ABAI). ABAI is the ratio of AB plasma transfused to group AB or unknown blood group patients to all AB plasma utilised, where values closer to 1 are better. METHODS: Data collected included AB plasma disposition by blood group, indications for transfusion, total blood utilisation, patient clinical characteristics and outcomes. ABAI during a 12-month period was retrospectively assessed, which led to implementation of pre-thawed group A plasma instead of group AB plasma for trauma patients starting in July 2017. RESULTS: The ABAI retrospectively showed inappropriate use in non-group AB patients in our hospital, the majority used to avoid expiry after thaw. When comparing 1-year pre- and post-implementation periods, ABAI improved from 0·464 to 0·900 (P < 0·0001). After exclusion of therapeutic plasma exchange, ABAI still improved (0·486-0·720, P < 0·0001). No differences in the length of stay or mortality associated in 32 patients receiving group A plasma for emergency release were observed. CONCLUSION: The ABAI is a novel KQI to indicate inappropriate AB plasma usage for quality improvement. This led to thawed A plasma use for MTPs, reducing inappropriate AB plasma usage.


Asunto(s)
Sistema del Grupo Sanguíneo ABO , Transfusión de Componentes Sanguíneos , Plasma , Heridas y Lesiones/terapia , Adulto , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Heridas y Lesiones/sangre
3.
Vox Sang ; 113(7): 701-706, 2018 10.
Artículo en Inglés | MEDLINE | ID: mdl-30144091

RESUMEN

While specific practices and transported blood products vary around the world, most of the respondents in this International Forum transported at least one blood product for the transfusion to bleeding patients en route to the hospital. The most commonly carried product was RBCs, while the use of whole blood will likely increase given the recent reports of its successful use in the civilian setting, and because of the change in the AABB's Standards regulating its use. It will be interesting to see if plasma use in the prehospital setting becomes more widely used given today's enhanced appreciated of the coagulopathy of trauma and plasma's beneficial effect in reversing it, and if blood products are transported to the scene of injury by more vehicles, that is, not just predominantly in helicopters. It was not surprising that TXA is being widely administered as close to the time of injury as possible given its potential benefit in these patients. This International Forum highlights the importance of focusing attention on prehospital transfusion management with a need to further high­quality research in this area to guide optimal resuscitation strategies.


Asunto(s)
Transfusión Sanguínea/métodos , Congresos como Asunto , Servicios Médicos de Urgencia/métodos , Hemorragia/terapia , Sustitutos Sanguíneos/uso terapéutico , Humanos
4.
Transfus Med ; 27(2): 122-131, 2017 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-28144996

RESUMEN

OBJECTIVE: Retrospective audit of IVIG Request Forms in four Ontario tertiary care centres: to determine the case mix of new IVIG requests, to authenticate information provided, and to determine documentation of clinical efficacy. AIMS: To understand contributors to increases in IVIG utilisation and to determine whether IVIG is being used and monitored appropriately. INTRODUCTION: Intravenous immunoglobulin (IVIG) use in Canada is high compared with other developed countries. We performed a retrospective audit of new IVIG Request Forms across four tertiary care centres in Ontario, one with an active surveillance programme, to determine the case mix, authenticate information provided and assess documentation of efficacy. METHODS: Consecutive adult patients with a first-time IVIG request in 2014 were included. The ordering physician specialty, form completeness, documentation of diagnostic criteria for the medical condition and indication for IVIG use and documentation of efficacy were assessed by form and chart review. RESULTS: Of 178 patients, the most common indications for IVIG were immune thrombocytopenia (24.2%) and secondary immune deficiency (20.2%). The most frequent prescribers were haematologists (37.6%) and neurologists (10.7%). Other conditions not listed on the form represented 24.2% of cases, with most not indicated in current guidelines. A total of 32.6% of cases overall lacked verification of diagnostic criteria and 51.7% lacked verification for IVIG utilisation criteria, with the number of cases meeting criteria based on documentation being higher at the active surveillance site (P = 0.005). A total of 19.1% of cases had a discrepancy between the indication written on the form and the documented clinical diagnosis. A total of 18.7% of clinic notes following IVIG had no mention of efficacy. CONCLUSION: Our audit demonstrates a lack of compliance with IVIG Request Form requirements, a lack of documentation of diagnostic criteria and efficacy, and suggests inappropriate use of IVIG. Current implementation of the form may not be sufficient as a strategy for improving appropriate IVIG use.


Asunto(s)
Inmunoglobulinas Intravenosas , Auditoría Médica , Registros Médicos , Centros de Atención Terciaria , Adulto , Femenino , Humanos , Masculino , Ontario , Estudios Retrospectivos
5.
Vox Sang ; 108(3): 274-80, 2015 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-25556889

RESUMEN

BACKGROUND: Prothrombin complex concentrates (PCCs) can be used instead of frozen plasma (FP) transfusion to reverse the effect of warfarin. Audits have demonstrated over usage of FP transfusions even before the introduction of PCC. The objective of this study was to determine the appropriateness of current FP transfusion practice in the current era since the introduction of PCCs. METHODS: A retrospective cohort study of consecutive patients receiving FP over 3 months was carried out. Each episode of FP use over a 24-h period was adjudicated independently by two reviewers as appropriate (consistent with Canadian/AABB guidelines), appropriate but inconsistent with guidelines or inappropriate. Discrepancies were resolved by a third reviewer. Use of FP to reverse warfarin was considered inappropriate. FP usage from previous years was assessed as baseline. RESULTS: During the study period, 111 FP transfusions were administered. 74.8% of FP usage occurred in the ICU. The proportion of FP transfusions that were deemed appropriate, inconsistent yet appropriate or inappropriate were 33/89 (37.1%), 16/89 (18.0%) and 40/89 (44.9%), respectively, when use of FP for therapeutic plasma exchange was excluded. The most common reasons for inappropriate use were the absence of bleeding with an increased INR or warfarin reversal. CONCLUSION: Our study is the first to audit FP transfusions in the post-PCC era in Canada. FP usage remains inappropriately high in INR prolongation without another indication or to reverse warfarin. Targeted interventions to reduce FP usage in the future should focus on the ICU and on education about warfarin reversal.


Asunto(s)
Factores de Coagulación Sanguínea/efectos adversos , Transfusión de Componentes Sanguíneos/métodos , Plasma , Adulto , Anciano , Anciano de 80 o más Años , Factores de Coagulación Sanguínea/uso terapéutico , Transfusión de Componentes Sanguíneos/normas , Transfusión de Componentes Sanguíneos/estadística & datos numéricos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...