Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Biosens Bioelectron ; 254: 116222, 2024 Jun 15.
Artículo en Inglés | MEDLINE | ID: mdl-38518560

RESUMEN

Materials that have the ability to manipulate shapes in response to stimuli such as heat, light, humidity and magnetism offer a means for versatile, sophisticated functions in soft robotics or biomedical implants, while such a reactive transformation has certain drawbacks including high operating temperatures, inherent rigidity and biological hazard. Herein, we introduce biodegradable, self-adhesive, shape-transformable poly (L-lactide-co-ε-caprolactone) (BSS-PLCL) that can be triggered via thermal stimulation near physiological temperature (∼38 °C). Chemical inspections confirm the fundamental properties of the synthetic materials in diverse aspects, and study on mechanical and biochemical characteristics validates exceptional stretchability up to 800 % and tunable dissolution behaviors under biological conditions. The integration of the functional polymer with a bioresorbable electronic system highlights potential for a wide range of biomedical applications.


Asunto(s)
Técnicas Biosensibles , Elastómeros , Elastómeros/química , Materiales Biocompatibles/química , Implantes Absorbibles , Polímeros/química , Poliésteres/química
3.
Nanomicro Lett ; 16(1): 102, 2024 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-38300387

RESUMEN

Substrates or encapsulants in soft and stretchable formats are key components for transient, bioresorbable electronic systems; however, elastomeric polymers with desired mechanical and biochemical properties are very limited compared to non-transient counterparts. Here, we introduce a bioresorbable elastomer, poly(glycolide-co-ε-caprolactone) (PGCL), that contains excellent material properties including high elongation-at-break (< 1300%), resilience and toughness, and tunable dissolution behaviors. Exploitation of PGCLs as polymer matrices, in combination with conducing polymers, yields stretchable, conductive composites for degradable interconnects, sensors, and actuators, which can reliably function under external strains. Integration of device components with wireless modules demonstrates elastic, transient electronic suture system with on-demand drug delivery for rapid recovery of post-surgical wounds in soft, time-dynamic tissues.

4.
Adv Mater ; 36(11): e2307391, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-37770105

RESUMEN

Current research in the area of surgical mesh implants is somewhat limited to traditional designs and synthesis of various mesh materials, whereas meshes with multiple functions may be an effective approach to address long-standing challenges including postoperative complications. Herein, a bioresorbable electronic surgical mesh is presented that offers high mechanical strength over extended timeframes, wireless post-operative pressure monitoring, and on-demand drug delivery for the restoration of tissue structure and function. The study of materials and mesh layouts provides a wide range of tunability of mechanical and biochemical properties. Dissolvable dielectric composite with porous structure in a pyramidal shape enhances sensitivity of a wireless capacitive pressure sensor, and resistive microheaters integrated with inductive coils provide thermo-responsive drug delivery system for an antibacterial agent. In vivo evaluations demonstrate reliable, long-lived operation, and effective treatment for abdominal hernia defects, by clear evidence of suppressed complications such as adhesion formation and infections.


Asunto(s)
Implantes Absorbibles , Hernia Abdominal , Humanos , Mallas Quirúrgicas , Hernia Abdominal/cirugía , Sistemas de Liberación de Medicamentos , Electrónica
5.
ACS Nano ; 17(15): 14822-14830, 2023 Aug 08.
Artículo en Inglés | MEDLINE | ID: mdl-37497757

RESUMEN

Although biodegradable, transient electronic devices must dissolve or decompose via environmental factors, an effective waterproofing or encapsulation system is essential for reliable, durable operation for a desired period of time. Existing protection approaches use multiple or alternate layers of electrically inactive organic/inorganic elements combined with polymers; however, their high mechanical stiffness is not suitable for soft, time-dynamic biological tissues/skins/organs. Here, we introduce a stretchable, bioresorbable encapsulant using nanoparticle-incorporated elastomeric composites with modifications of surface morphology. Nature-inspired micropatterns reduce the diffusion area for water molecules, and embedded nanoparticles impede water permeation, which synergistically enhances the water-barrier performance. Empirical and theoretical evaluations validate the encapsulation mechanisms under strains. Demonstration of a soft, degradable shield with an optical component under a biological solution highlights the potential applicability of the proposed encapsulation strategy.

6.
ACS Nano ; 17(9): 8511-8520, 2023 05 09.
Artículo en Inglés | MEDLINE | ID: mdl-37070621

RESUMEN

Current standard clinical options for patients with detrusor underactivity (DUA) or underactive bladder─the inability to release urine naturally─include the use of medications, voiding techniques, and intermittent catheterization, for which the patient inserts a tube directly into the urethra to eliminate urine. Although those are life-saving techniques, there are still unfavorable side effects, including urinary tract infection (UTI), urethritis, irritation, and discomfort. Here, we report a wireless, fully implantable, and expandable electronic complex that enables elaborate management of abnormal bladder function via seamless integrations with the urinary bladder. Such electronics can not only record multiple physiological parameters simultaneously but also provide direct electrical stimulation based on a feedback control system. Uniform distribution of multiple stimulation electrodes via mesh-type geometry realizes low-impedance characteristics, which improves voiding/urination efficiency at the desired times. In vivo evaluations using live, free-moving animal models demonstrate system-level functionality.


Asunto(s)
Vejiga Urinaria de Baja Actividad , Vejiga Urinaria , Animales
7.
Nat Commun ; 14(1): 2263, 2023 04 20.
Artículo en Inglés | MEDLINE | ID: mdl-37081012

RESUMEN

As rubber-like elastomers have led to scientific breakthroughs in soft, stretchable characteristics-based wearable, implantable electronic devices or relevant research fields, developments of degradable elastomers with comparable mechanical properties could bring similar technological innovations in transient, bioresorbable electronics or expansion into unexplored areas. Here, we introduce ultra-stretchable, biodegradable elastomers capable of stretching up to ~1600% with outstanding properties in toughness, tear-tolerance, and storage stability, all of which are validated by comprehensive mechanical and biochemical studies. The facile formation of thin films enables the integration of almost any type of electronic device with tunable, suitable adhesive strengths. Conductive elastomers tolerant/sensitive to mechanical deformations highlight possibilities for versatile monitoring/sensing components, particularly the strain-tolerant composites retain high levels of conductivities even under tensile strains of ~550%. Demonstrations of soft electronic grippers and transient, suture-free cardiac jackets could be the cornerstone for sophisticated, multifunctional biodegradable electronics in the fields of soft robots and biomedical implants.


Asunto(s)
Robótica , Dispositivos Electrónicos Vestibles , Elastómeros/química , Electrónica , Prótesis e Implantes
8.
Sci Adv ; 9(5): eadf5883, 2023 Feb 03.
Artículo en Inglés | MEDLINE | ID: mdl-36724224

RESUMEN

Recent advances in passive radiative cooling systems describe a variety of strategies to enhance cooling efficiency, while the integration of such technology with a bioinspired design using biodegradable materials can offer a research opportunity to generate energy in a sustainable manner, favorable for the temperature/climate system of the planet. Here, we introduce stretchable and ecoresorbable radiative cooling/heating systems engineered with zebra stripe-like patterns that enable the generation of a large in-plane temperature gradient for thermoelectric generation. A comprehensive study of materials with theoretical evaluations validates the ability to accomplish the target performances even under external mechanical strains, while all systems eventually disappear under physiological conditions. Use of the zebra print for selective radiative heating demonstrates an unexpected level of temperature difference compared to use of radiative cooling emitters alone, which enables producing energy through resorbable silicon-based thermoelectric devices. The overall result suggests the potential of scalable, ecofriendly renewable energy systems.

9.
Adv Mater ; 34(14): e2108203, 2022 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-35073597

RESUMEN

Although neurotransmitters are key substances closely related to evaluating degenerative brain diseases as well as regulating essential functions in the body, many research efforts have not been focused on direct observation of such biochemical messengers, rather on monitoring relatively associated physical, mechanical, and electrophysiological parameters. Here, a bioresorbable silicon-based neurochemical analyzer incorporated with 2D transition metal dichalcogenides is introduced as a completely implantable brain-integrated system that can wirelessly monitor time-dynamic behaviors of dopamine and relevant parameters in a simultaneous mode. An extensive range of examinations of molybdenum/tungsten disulfide (MoS2 /WS2 ) nanosheets and catalytic iron nanoparticles (Fe NPs) highlights the underlying mechanisms of strong chemical and target-specific responses to the neurotransmitters, along with theoretical modeling tools. Systematic characterizations demonstrate reversible, stable, and long-term operational performances of the degradable bioelectronics with excellent sensitivity and selectivity over those of non-dissolvable counterparts. A complete set of in vivo experiments with comparative analysis using carbon-fiber electrodes illustrates the capability for potential use as a clinically accessible tool to associated neurodegenerative diseases.


Asunto(s)
Silicio , Compuestos de Tungsteno , Implantes Absorbibles , Electrodos , Silicio/química , Sulfuros
10.
ACS Nano ; 15(12): 19310-19320, 2021 12 28.
Artículo en Inglés | MEDLINE | ID: mdl-34843199

RESUMEN

The lifetime of transient electronic components can be programmed via the use of encapsulation/passivation layers or of on-demand, stimuli-responsive polymers (heat, light, or chemicals), but yet most research is limited to slow dissolution rate, hazardous constituents, or byproducts, or complicated synthesis of reactants. Here we present a physicochemical destruction system with dissolvable, nontoxic materials as an efficient, multipurpose platform, where chemically produced bubbles rapidly collapse device structures and acidic molecules accelerate dissolution of functional traces. Extensive studies of composites based on biodegradable polymers (gelatin and poly(lactic-co-glycolic acid)) and harmless blowing agents (organic acid and bicarbonate salt) validate the capability for the desired system. Integration with wearable/recyclable electronic components, fast-degradable device layouts, and wireless microfluidic devices highlights potential applicability toward versatile/multifunctional transient systems. In vivo toxicity tests demonstrate biological safety of the proposed system.


Asunto(s)
Electrónica , Polímeros
11.
Adv Mater ; 32(51): e2002211, 2020 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-32974973

RESUMEN

Transient electronics refers to an emerging class of advanced technology, defined by an ability to chemically or physically dissolve, disintegrate, and degrade in actively or passively controlled fashions to leave environmentally and physiologically harmless by-products in environments, particularly in bio-fluids or aqueous solutions. The unusual properties that are opposite to operational modes in conventional electronics for a nearly infinite time frame offer unprecedented opportunities in research areas of eco-friendly electronics, temporary biomedical implants, data-secure hardware systems, and others. This review highlights the developments of transient electronics, including materials, manufacturing strategies, electronic components, and transient kinetics, along with various potential applications.


Asunto(s)
Materiales Biocompatibles , Equipos y Suministros Eléctricos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...