1.
J Pharm Biomed Anal ; 44(5): 1100-5, 2007 Sep 03.
Artículo en Inglés | MEDLINE | ID: mdl-17553649

RESUMEN

A novel precolumn derivatization method is described for the quantitative determination of amantadine, rimantadine and memantine in biological samples by HPLC with UV detection. The derivatization was performed at room temperature using anthraquinone-2-sulfonyl chloride (ASC) as reagent for only 10 min and without postderivatization treatment to inactivate excess reagent. The derivatives were analyzed by isocratic HPLC with a UV detector at 256 nm on a Lichrosper C18 column. The linear range for the determination of three drugs spiked in plasma (0.2 ml) was 0.05-5.0 microg/ml for amantadine and rimantadine, 0.05-2.0 microg/ml for memantine, respectively. The limits of detection and quantification were 20 and 50 ng/ml for the analytes, respectively. Application of the method to the analysis of amantadine, rimantadine and memantine in rat plasma and pharmacokinetic studies are demonstrated and proved feasible.


Asunto(s)
Amantadina/sangre , Antivirales/sangre , Cromatografía Líquida de Alta Presión/métodos , Memantina/sangre , Rimantadina/sangre , Amantadina/química , Animales , Antivirales/química , Calibración , Estabilidad de Medicamentos , Estudios de Factibilidad , Masculino , Memantina/química , Estructura Molecular , Ratas , Ratas Sprague-Dawley , Rimantadina/química , Sensibilidad y Especificidad , Espectrofotometría Ultravioleta , Temperatura , Factores de Tiempo