Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 16 de 16
Filtrar
1.
Khirurgiia (Mosk) ; (12): 66-73, 2019.
Artículo en Ruso | MEDLINE | ID: mdl-31825345

RESUMEN

RELEVANCE: The leveling of postoperative pain, early activation of patients are the leading components of the fast-track program, providing fast recovery with good quality of life, minimizing postoperative problems. In colorectal surgery, the most important factor determining the early recovery of patients is the normalization of bowel function, the restoration of defecation rhythm. AIM: To assess the possibility of using dietary fiber (arabinogalactan) in combination with lactoferrin (the drug Fibraxin, Alfa Sigma) in the complex postoperative therapy of proctologic patients, as well as to determine the effectiveness of their influence on the dynamics of rehabilitation. MATERIAL AND METHODS: A non-randomized cohort comparative prospective study was conducted in two clinical groups of 100 patients operated on for proctological pathology. In the first (control) group, after the operation, venotonics were prescribed for 2-3 weeks, as well as topical preparations - for 2.5 weeks. In the second (main) group, this treatment is supplemented with the use of Fibraxin, at a dosage of 6g 1 time per day, the observation period is 4 weeks. A comparative analysis of the rates of relief of postoperative defecation disorders, as well as the effect of the drug on the dynamics of the relief of leading postoperative complaints, has been carried out. RESULTS: In the main group, the best results were obtained for the main parameters analyzed, early normalization of the frequency and rhythm of bowel movements was achieved, with adequate relief of complaints of pain during bowel movements and after it. Intolerance to the drug and pathological reactions associated with its use was not. The positive effect of Fibraxin in patients with concomitant diseases of the colon, including colitis, irritable bowel syndrome, diverticular disease and chronic colonic stasis, was noted. CONCLUSION: The use of the drug Fibraxin at a dose of 6g per day allows a significant influence on the course of the postoperative period in proctological patients. The inclusion of Fibraxin in the scheme of rehabilitation treatment allows to stabilize the immediate results of treatment and reliably improve long-term, due to the correction of rectal dysfunction, elimination of dysbiosis, normalization of motility, as well as potentiation of reparative and restorative processes.


Asunto(s)
Defecación/fisiología , Galactanos/administración & dosificación , Fármacos Gastrointestinales/administración & dosificación , Intestinos/fisiopatología , Lactoferrina/administración & dosificación , Proctectomía/rehabilitación , Protocolos Clínicos , Estreñimiento/etiología , Estreñimiento/terapia , Humanos , Intestinos/cirugía , Laxativos/administración & dosificación , Proctectomía/efectos adversos , Estudios Prospectivos , Calidad de Vida , Factores de Tiempo , Resultado del Tratamiento
2.
Khirurgiia (Mosk) ; (8. Vyp. 2): 32-39, 2019.
Artículo en Ruso | MEDLINE | ID: mdl-31502591

RESUMEN

AIM: To objectify the criteria for choosing the method of treatment of anal fissures, to determine the indications for surgery and sphincterotomy. MATERIAL AND METHODS: The results of treatment of 206 patients with chronic and acute anal fissures between the ages of 17 to 75 years are analyzed. The posterior anal fissure was detected in 175 (84.9%) patients, the front - in 18 (8.7%), the combination of fissures was noted 13 (6.3%) times. The history of the disease - from 1 month to 12 years. The examination included analysis of clinical data, indicators of pre- and postoperative anorectal manometry, endorectal ultrasound. The period of postoperative monitoring is from 6 to 12 months, control examinations with a functional study of the anal sphincters were carried out 1 and 2 months after healing. Concomitant hemorrhoids were noted in 65 (31.5%) patients, of which 20 (9.7%) patients were simultaneously hemorrhoidectomized. In 11 (5.3%) patients, simultaneous operations were performed in the presence of paraproctitis, rectal fistula. RESULTS: In 77.8% of patients with acute fissures, the use of conservative therapy, which included myotropic antispasmodics and local application of glycerol trinitrate made it possible to achieve healing of fissures without surgery. Operated 185 (89.8%) patients. With an increase in the basal anal pressure at the level of the internal sphincter, an increase in the average pressure in the anal canal, a decrease in the amplitude and duration of the rectoanal reflex, the indications for dosed sphincterotomy were determined in 167 patients. At the same time, in 117 persons, the excision of fissures was supplemented with a lateral 'closed' sphincterotomy, in 50 cases the posterior 'open' dosed sphincterotomy was performed. In 18 (9.7% of the operated ones) patients in the absence of sphincter hypertonus, the fissures were excised without sphincterotomy. The best functional results were obtained after performing the lateral 'closed' subcutaneous sphincterotomy. It was noticed that in the absence of characteristic complaints and clinical manifestations of incontinence, in 14 patients there was a decrease in the average pressure in the anal canal at rest and with volitional contraction. At the same time, 6 patients out of 14 belonged to the older age groups, and in 9 women there was a rectocele, pelvic floor prolapse. Postoperative incontinence was not observed. Recovery with complete epithelialization of the anoderm defect and the absence of complaints was achieved in 191 (92.7%) patients, satisfactory results (healing of fissures in the presence of pain or proctitis) - in 8 (3.9%) and in 7 (3.4%) patients relapse of the disease was noted with the ineffectiveness of therapy. CONCLUSION: The ineffectiveness of complex conservative treatment for more than two weeks, with a history of more than 3 months, is an indication for surgical treatment. Preoperative functional and clinical and physiological examination of patients allows the formation of surgical tactics. A differentiated approach to the choice of treatment method, as well as individual determination of indications for surgery and sphincterotomy can improve long-term results. The technique of simultaneous operations with the combination of anal fissure and other proctological diseases needs to be improved.


Asunto(s)
Canal Anal/cirugía , Fisura Anal/tratamiento farmacológico , Fisura Anal/cirugía , Enfermedad Aguda , Adolescente , Adulto , Anciano , Enfermedad Crónica , Femenino , Fisura Anal/terapia , Humanos , Persona de Mediana Edad , Esfinterotomía , Resultado del Tratamiento , Cicatrización de Heridas , Adulto Joven
3.
Astrobiology ; 17(6-7): 585-594, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-28731818

RESUMEN

This overview presents the physical principles, design, measurement capabilities, and summary of planned operations of the autonomous detector of radiation of neutrons onboard rover at Mars (ADRON-RM) on the surface of Mars. ADRON-RM is a Russian project selected for the joint European Space Agency-Roscosmos ExoMars 2020 landing mission. A compact passive neutron spectrometer, ADRON-RM, was designed to study the abundance and distribution of water and neutron absorption elements (such as Cl, Fe, and others) in the martian subsurface along the path of the ExoMars rover. Key Words: Mars exploration-Surface-Neutron Spectroscopy-Water. Astrobiology 17, 585-594.

4.
Rev Sci Instrum ; 87(8): 085112, 2016 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-27587165

RESUMEN

The recent availability of large volume cerium bromide crystals raises the possibility of substantially improving gamma-ray spectrometer limiting flux sensitivities over current systems based on the lanthanum tri-halides, e.g., lanthanum bromide and lanthanum chloride, especially for remote sensing, low-level counting applications or any type of measurement characterized by poor signal to noise ratios. The Russian Space Research Institute has developed and manufactured a highly sensitive gamma-ray spectrometer for remote sensing observations of the planet Mercury from the Mercury Polar Orbiter (MPO), which forms part of ESA's BepiColombo mission. The Flight Model (FM) gamma-ray spectrometer is based on a 3-in. single crystal of LaBr3(Ce(3+)) produced in a separate crystal development programme specifically for this mission. During the spectrometers development, manufacturing, and qualification phases, large crystals of CeBr3 became available in a subsequent phase of the same crystal development programme. Consequently, the Flight Spare Model (FSM) gamma-ray spectrometer was retrofitted with a 3-in. CeBr3 crystal and qualified for space. Except for the crystals, the two systems are essentially identical. In this paper, we report on a comparative assessment of the two systems, in terms of their respective spectral properties, as well as their suitability for use in planetary mission with respect to radiation tolerance and their propensity for activation. We also contrast their performance with a Ge detector representative of that flown on MESSENGER and show that: (a) both LaBr3(Ce(3+)) and CeBr3 provide superior detection systems over HPGe in the context of minimally resourced spacecraft and (b) CeBr3 is a more attractive system than LaBr3(Ce(3+)) in terms of sensitivities at lower gamma fluxes. Based on the tests, the FM has now been replaced by the FSM on the BepiColombo spacecraft. Thus, CeBr3 now forms the central gamma-ray detection element on the MPO spacecraft.

5.
Appl Radiat Isot ; 69(7): 965-8, 2011 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-21440450

RESUMEN

A method to produce (117m)Sn radionuclide using accelerator production route is described. A new method is proposed to separate the (117m)Sn. Specific activities and thick target yield for (116)Cd(α,3n)(117m)Sn reaction at E(α)=35MeV bombarding energy were determined. The estimated production yield of (117m)Sn was 37.5kBq/µAh for 13.16 mg/cm(2) natural cadmium-oxide target and 410 kBq/µAh for 11.07 mg/cm(2) highly enriched (95%) (116)CdO target. The method developed for separation of (117m)Sn from Cd using anion-exchange resin (Dowex -1×8, fluorine form, 400 mesh) can achieve 98% radiochemical yield of (117m)Sn with more than 99% radionuclidic purity. The estimated specific activity is 2.4 GBq/mg that can be reached with the used irradiation conditions.

6.
Science ; 330(6003): 483-6, 2010 Oct 22.
Artículo en Inglés | MEDLINE | ID: mdl-20966247

RESUMEN

Hydrogen has been inferred to occur in enhanced concentrations within permanently shadowed regions and, hence, the coldest areas of the lunar poles. The Lunar Crater Observation and Sensing Satellite (LCROSS) mission was designed to detect hydrogen-bearing volatiles directly. Neutron flux measurements of the Moon's south polar region from the Lunar Exploration Neutron Detector (LEND) on the Lunar Reconnaissance Orbiter (LRO) spacecraft were used to select the optimal impact site for LCROSS. LEND data show several regions where the epithermal neutron flux from the surface is suppressed, which is indicative of enhanced hydrogen content. These regions are not spatially coincident with permanently shadowed regions of the Moon. The LCROSS impact site inside the Cabeus crater demonstrates the highest hydrogen concentration in the lunar south polar region, corresponding to an estimated content of 0.5 to 4.0% water ice by weight, depending on the thickness of any overlying dry regolith layer. The distribution of hydrogen across the region is consistent with buried water ice from cometary impacts, hydrogen implantation from the solar wind, and/or other as yet unknown sources.


Asunto(s)
Luna , Medio Ambiente Extraterrestre , Hidrógeno , Análisis Espectral
7.
Astrobiology ; 8(4): 793-804, 2008 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-18844457

RESUMEN

The scientific objectives of neutron mapping of the Moon are presented as 3 investigation tasks of NASA's Lunar Reconnaissance Orbiter mission. Two tasks focus on mapping hydrogen content over the entire Moon and on testing the presence of water-ice deposits at the bottom of permanently shadowed craters at the lunar poles. The third task corresponds to the determination of neutron contribution to the total radiation dose at an altitude of 50 km above the Moon. We show that the Lunar Exploration Neutron Detector (LEND) will be capable of carrying out all 3 investigations. The design concept of LEND is presented together with results of numerical simulations of the instrument's sensitivity for hydrogen detection. The sensitivity of LEND is shown to be characterized by a hydrogen detection limit of about 100 ppm for a polar reference area with a radius of 5 km. If the presence of ice deposits in polar "cold traps" is confirmed, a unique record of many millions of years of lunar history would be obtained, by which the history of lunar impacts could be discerned from the layers of water ice and dust. Future applications of a LEND-type instrument for Mars orbital observations are also discussed.


Asunto(s)
Luna , Neutrones , Frío , Diseño de Equipo , Medio Ambiente Extraterrestre , Hidrógeno , Hielo , Modelos Teóricos , Vuelo Espacial/instrumentación , Nave Espacial/instrumentación , Estados Unidos , United States National Aeronautics and Space Administration
8.
Astrobiology ; 8(3): 605-12, 2008 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-18598140

RESUMEN

We present a summary of the physical principles and design of the Dynamic Albedo of Neutrons (DAN) instrument onboard NASA's 2009 Mars Science Laboratory (MSL) mission. The DAN instrument will use the method of neutron-neutron activation analysis in a space application to study the abundance and depth distribution of water in the martian subsurface along the path of the MSL rover.


Asunto(s)
Laboratorios , Marte , Neutrones , Vuelo Espacial/instrumentación , United States National Aeronautics and Space Administration , Hidrógeno/análisis , Análisis Numérico Asistido por Computador , Suelo/análisis , Estados Unidos
9.
Radiat Prot Dosimetry ; 116(1-4 Pt 2): 449-53, 2005.
Artículo en Inglés | MEDLINE | ID: mdl-16604676

RESUMEN

The radiation fields outside the planned experimental Sub-critical Assembly in Dubna (SAD) have been studied in order to provide a basis for the design of the concrete shielding that cover the reactor core. The effective doses around the reactor, induced by leakage of neutrons and photons through the shielding, have been determined for a shielding thickness varying from 100 to 200 cm. It was shown that the neutron flux and the effective dose is higher above the shielding than at the side of it, owing to the higher fraction of high-energy spallation neutrons emitted in the direction of the incident beam protons. At the top, the effective dose was found to be -150 microSv s(-1) for a concrete thickness of 100 cm, while -2.5 microSv s(-1) for a concrete thickness of 200 cm. It was also shown that the high-energy neutrons (> 10 MeV), which are created in the proton-induced spallation interactions in the target, contribute for the major part of the effective doses outside the reactor.


Asunto(s)
Materiales de Construcción/análisis , Modelos Estadísticos , Reactores Nucleares/instrumentación , Aceleradores de Partículas/instrumentación , Monitoreo de Radiación/métodos , Protección Radiológica/instrumentación , Protección Radiológica/métodos , Simulación por Computador , Diseño Asistido por Computadora , Análisis de Falla de Equipo , Método de Montecarlo , Dosis de Radiación , Federación de Rusia
10.
J Res Natl Inst Stand Technol ; 110(3): 225-30, 2005.
Artículo en Inglés | MEDLINE | ID: mdl-27308126

RESUMEN

Although crucial for resolving the issue of charge symmetry in the nuclear force, direct measurement of nn-scattering by colliding free neutrons has never been performed. At present the Russian pulsed reactor YAGUAR is the best neutron source for performing such a measurement. It has a through channel where the neutron moderator is installed. The neutrons are counted by a neutron detector located 12 m from the reactor. In preliminary experiments an instantaneous value of 1.1 × 10(18)/cm(2)s was obtained for the thermal neutron flux density. The experiment will be performed by the DIANNA Collaboration as International Science & Technology Center (ISTC) project No. 2286.

11.
Science ; 297(5578): 78-81, 2002 Jul 05.
Artículo en Inglés | MEDLINE | ID: mdl-12040089

RESUMEN

After 55 days of mapping by the High Energy Neutron Detector onboard Mars Odyssey, we found deficits of high-energy neutrons in the southern highlands and northern lowlands of Mars. These deficits indicate that hydrogen is concentrated in the subsurface. Modeling suggests that water ice-rich layers that are tens of centimeters in thickness provide one possible fit to the data.


Asunto(s)
Hidrógeno , Hielo , Marte , Neutrones , Atmósfera , Radiación Cósmica , Medio Ambiente Extraterrestre , Modelos Teóricos , Nave Espacial , Espectrometría gamma , Análisis Espectral , Temperatura
12.
Artículo en Inglés | MEDLINE | ID: mdl-11969617

RESUMEN

We present a macroscopic model of mixed multilane freeway traffic that can be easily calibrated to empirical traffic data, as is shown for Dutch highway data. The model is derived from a gas-kinetic level of description, including effects of vehicular space requirements and velocity correlations between successive vehicles. We also give a derivation of the lane-changing rates. The resulting dynamic velocity equations contain nonlocal and anisotropic interaction terms which allow a robust and efficient numerical simulation of multilane traffic. As demonstrated by various examples, this facilitates the investigation of synchronization patterns among lanes and effects of on ramps, off ramps, lane closures, or accidents.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA