Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros










Intervalo de año de publicación
1.
Acta Cir Bras ; 33(9): 792-798, 2018 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-30328911

RESUMEN

PURPOSE: To evaluate the fibrosis induced by four different meshes: Marlex®, Parietex Composite®, Vicryl® and Ultrapro®. METHODS: Histological cutouts of abdominal wall were analyzed with polarized light 28 days after the meshes implants and colorized by picrosirius to identify the intensity of collagen types I and III, and their maturation index. RESULTS: When the four groups were compared, the total collagen area analyzed was bigger in groups A and D, with no difference between them. The collagen type I density was bigger in group A, with an average of 9.62 ± 1.0, and smaller in group C, with an average of 3.86 ± 0.59. The collagen type III density was similar in groups A, B and C, and bigger in group D. The collagen maturation index was different in each of the four groups, bigger in group A with 0.87, group B with 0.66, group D with 0.57 and group C with 0.33 (p = 0.0000). CONCLUSION: The most prominent fibrosis promotion in the given meshes was found on Marlex® (polypropylene mesh) and the Parietex Composite® (non-biodegradable polyester); the collagen maturation index was higher in the Marlex® mesh, followed by Ultrapro®, Parietex Composite® and Vicryl® meshes.


Asunto(s)
Pared Abdominal/patología , Colágeno/efectos adversos , Poliésteres/efectos adversos , Poliglactina 910/efectos adversos , Polipropilenos/efectos adversos , Mallas Quirúrgicas/efectos adversos , Pared Abdominal/cirugía , Animales , Colágeno/administración & dosificación , Fibrosis/etiología , Fibrosis/patología , Ensayo de Materiales , Modelos Animales , Poliésteres/administración & dosificación , Poliglactina 910/administración & dosificación , Polipropilenos/administración & dosificación , Factores de Tiempo , Adherencias Tisulares/etiología , Adherencias Tisulares/patología
2.
Acta cir. bras ; 33(9): 792-798, Sept. 2018. graf
Artículo en Inglés | LILACS | ID: biblio-973505

RESUMEN

Abstract Purpose: To evaluate the fibrosis induced by four different meshes: Marlex®, Parietex Composite®, Vicryl® and Ultrapro®. Methods: Histological cutouts of abdominal wall were analyzed with polarized light 28 days after the meshes implants and colorized by picrosirius to identify the intensity of collagen types I and III, and their maturation index. Results: When the four groups were compared, the total collagen area analyzed was bigger in groups A and D, with no difference between them. The collagen type I density was bigger in group A, with an average of 9.62 ± 1.0, and smaller in group C, with an average of 3.86 ± 0.59. The collagen type III density was similar in groups A, B and C, and bigger in group D. The collagen maturation index was different in each of the four groups, bigger in group A with 0.87, group B with 0.66, group D with 0.57 and group C with 0.33 (p = 0.0000). Conclusion: The most prominent fibrosis promotion in the given meshes was found on Marlex® (polypropylene mesh) and the Parietex Composite® (non-biodegradable polyester); the collagen maturation index was higher in the Marlex® mesh, followed by Ultrapro®, Parietex Composite® and Vicryl® meshes.


Asunto(s)
Animales , Poliésteres/efectos adversos , Poliglactina 910/efectos adversos , Polipropilenos/efectos adversos , Mallas Quirúrgicas/efectos adversos , Colágeno/efectos adversos , Pared Abdominal/patología , Poliésteres/administración & dosificación , Poliglactina 910/administración & dosificación , Polipropilenos/administración & dosificación , Factores de Tiempo , Fibrosis/etiología , Fibrosis/patología , Ensayo de Materiales , Adherencias Tisulares/etiología , Adherencias Tisulares/patología , Colágeno/administración & dosificación , Modelos Animales , Pared Abdominal/cirugía
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...