1.
Sensors (Basel) ; 19(15)2019 07 26.
Artículo en Inglés | MEDLINE | ID: mdl-31357545

RESUMEN

The goal of this work is to further improve positron emission tomography (PET) attenuation correction and magnetic resonance (MR) sensitivity for head and neck applications of PET/MR. A dedicated 24-channel receive-only array, fully-integrated with a hydraulic system to move a transmission source helically around the patient and radiofrequency (RF) coil array, is designed, implemented, and evaluated. The device enables the calculation of attenuation coefficients from PET measurements at 511 keV including the RF coil and the particular patient. The RF coil design is PET-optimized by minimizing photon attenuation from coil components and housing. The functionality of the presented device is successfully demonstrated by calculating the attenuation map of a water bottle based on PET transmission measurements; results are in excellent agreement with reference values. It is shown that the device itself has marginal influence on the static magnetic field B0 and the radiofrequency transmit field B1 of the 3T PET/MR system. Furthermore, the developed RF array is shown to outperform a standard commercial 16-channel head and neck coil in terms of signal-to-noise ratio (SNR) and parallel imaging performance. In conclusion, the presented hardware enables accurate calculation of attenuation maps for PET/MR systems while improving the SNR of corresponding MR images in a single device without degrading the B0 and B1 homogeneity of the scanner.


Asunto(s)
Cabeza/diagnóstico por imagen , Imagen por Resonancia Magnética/métodos , Cuello/diagnóstico por imagen , Tomografía de Emisión de Positrones/métodos , Humanos , Procesamiento de Imagen Asistido por Computador , Imagen Multimodal , Fantasmas de Imagen , Ondas de Radio , Relación Señal-Ruido
2.
PLoS One ; 13(11): e0206963, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-30383832

RESUMEN

PURPOSE: The purpose of this work is the design, implementation and evaluation of a mechanically flexible receive-only coil array for magnetic resonance imaging (MRI) at 3 T that can be applied to various target organs and provides high parallel imaging performance. METHODS: A 23-channel array was designed based on a rigid-flex printed circuit board (PCB). The flexible multi-layer part contains the copper traces forming the coil elements. The rigid part of the PCB houses the solder joints and lumped elements. The coil housing consists of rigid caps mounted above the rigid parts. Adhesive PTFE sheets cover all flexible parts. The developed array was tested on the bench as well as in phantom and in vivo MRI experiments employing parallel imaging acceleration factors up to six. RESULTS: Efficient mutual decoupling between receive elements and detuning between receive array and body coil was achieved. An increased signal-to-noise ratio in comparison to commercial reference coils is demonstrated, especially in regions close to the developed array and for high parallel imaging acceleration factors. Exemplary in vivo images of head, ankle, knee, shoulder and hand are presented. CONCLUSION: Based on high sensitivity close to the array and low g-factors, this flexible coil is well suited for studies of occipital and temporal cortex, as well as musculoskeletal targets like knee, ankle, elbow and wrist.


Asunto(s)
Diseño de Equipo , Imagen por Resonancia Magnética , Encéfalo/diagnóstico por imagen , Humanos , Articulaciones/diagnóstico por imagen , Imagen por Resonancia Magnética/métodos , Imagen por Resonancia Magnética/normas , Fantasmas de Imagen
3.
J Magn Reson ; 296: 47-59, 2018 11.
Artículo en Inglés | MEDLINE | ID: mdl-30205313

RESUMEN

A flexible transceiver array based on transmission line resonators (TLRs) combining the advantages of coil arrays with the possibility of form-fitting targeting cardiac MRI at 7 T is presented. The design contains 12 elements which are fabricated on a flexible substrate with rigid PCBs attached on the center of each element to place the interface components, i.e. transmit/receive (T/R) switch, power splitter, pre-amplifier and capacitive tuning/matching circuitry. The mutual coupling between elements is cancelled using a decoupling ring-based technique. The performance of the developed array is evaluated by 3D electromagnetic simulations, bench tests, and MR measurements using phantoms. Efficient inter-element decoupling is demonstrated in flat configuration on a box-shaped phantom (Sij < -19 dB), and bent on a human torso phantom (Sij < -16 dB). Acceleration factors up to 3 can be employed in bent configuration with reasonable g-factors (<1.7) in an ROI at the position of the heart. The array enables geometrical conformity to bodies within a large range of size and shape and is compatible with parallel imaging and parallel transmission techniques.


Asunto(s)
Imagen por Resonancia Magnética/instrumentación , Simulación por Computador , Campos Electromagnéticos , Corazón/diagnóstico por imagen , Humanos , Aumento de la Imagen , Fantasmas de Imagen , Ondas de Radio , Relación Señal-Ruido , Torso/diagnóstico por imagen
4.
Sci Rep ; 8(1): 6211, 2018 04 18.
Artículo en Inglés | MEDLINE | ID: mdl-29670177

RESUMEN

13C magnetic resonance spectroscopy is a viable, non-invasive method to study cell metabolism in skeletal muscles. However, MR sensitivity of 13C is inherently low, which can be overcome by applying a higher static magnetic field strength together with radiofrequency coil arrays instead of single loop coils or large volume coils, and 1H decoupling, which leads to a simplified spectral pattern. 1H-decoupled 13C-MRS requires RF coils which support both, 1H and 13C, Larmor frequencies with sufficient electromagnetic isolation between the pathways of the two frequencies. We present the development, evaluation, and first in vivo measurement with a 7 T 3-channel 13C and 4-channel 1H transceiver array optimized for 1H-decoupled 13C-MRS in the posterior human calf muscles. To ensure minimal cross-coupling between 13C and 1H arrays, several strategies were combined: mutual magnetic flux was minimized by coil geometry, two LCC traps were inserted into each 13C element, and band-pass and low-pass filters were integrated along the signal pathways. The developed coil array was successfully tested in phantom and in vivo MR experiments, showing a simplified spectral pattern and increase in signal-to-noise ratio of approximately a factor 2 between non-decoupled and 1H-decoupled spectra in a glucose phantom and the human calf muscle.


Asunto(s)
Espectroscopía de Resonancia Magnética con Carbono-13 , Músculo Esquelético/química , Espectroscopía de Protones por Resonancia Magnética , Ondas de Radio , Espectroscopía de Resonancia Magnética con Carbono-13/métodos , Campos Electromagnéticos , Fenómenos Electromagnéticos , Glucógeno/análisis , Glucógeno/química , Humanos , Fantasmas de Imagen , Espectroscopía de Protones por Resonancia Magnética/métodos
5.
Magn Reson Med ; 79(1): 588-592, 2018 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-28295563

RESUMEN

PURPOSE: To demonstrate a dedicated setup for ultrahigh resolution MR imaging of the human finger in vivo. METHODS: A radiofrequency coil was designed for optimized signal homogeneity and sensitivity in the finger at ultrahigh magnetic field strength (7 T), providing high measurement sensitivity. Imaging sequences (2D turbo-spin echo (TSE) and 3D magnetization-prepared rapid acquisition gradient echo (MPRAGE)) were adapted for high spatial resolution and good contrast of different tissues in the finger, while keeping acquisition time below 10 minutes. Data was postprocessed to display finger structures in three dimensions. RESULTS: 3D MPRAGE data with isotropic resolution of 200 µm, along with 2D TSE images with in-plane resolutions of 58 × 78 µm2 and 100 × 97 µm2 , allowed clear identification of various anatomical features such as bone and bone marrow, tendons and annular ligaments, cartilage, arteries and veins, nerves, and Pacinian corpuscles. CONCLUSION: Using this dedicated finger coil at 7 T, together with adapted acquisition sequences, it is possible to depict the internal structures of the human finger in vivo within patient-compatible measurement time. It may serve as a tool for diagnosis and treatment monitoring in pathologies ranging from inflammatory or erosive joint diseases to injuries of tendons and ligaments to nervous or vascular disorders in the finger. Magn Reson Med 79:588-592, 2018. © 2017 The Authors Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine. This is an open access article under the terms of the Creative Commons Attribution License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.


Asunto(s)
Dedos/diagnóstico por imagen , Imagen por Resonancia Magnética , Simulación por Computador , Humanos , Imagenología Tridimensional , Espectroscopía de Resonancia Magnética , Modelos Anatómicos , Fantasmas de Imagen , Ondas de Radio , Relación Señal-Ruido
6.
Magn Reson Med ; 74(5): 1492-501, 2015 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-25421603

RESUMEN

PURPOSE: To overcome current limitations in combined transcranial magnetic stimulation (TMS) and functional magnetic resonance imaging (fMRI) studies by employing a dedicated coil array design for 3 Tesla. METHODS: The state-of-the-art setup for concurrent TMS/fMRI is to use a large birdcage head coil, with the TMS between the subject's head and the MR coil. This setup has drawbacks in sensitivity, positioning, and available imaging techniques. In this study, an ultraslim 7-channel receive-only coil array for 3 T, which can be placed between the subject's head and the TMS, is presented. Interactions between the devices are investigated and the performance of the new setup is evaluated in comparison to the state-of-the-art setup. RESULTS: MR sensitivity obtained at the depth of the TMS stimulation is increased by a factor of five. Parallel imaging with an acceleration factor of two is feasible with low g-factors. Possible interactions between TMS and the novel hardware were investigated and were found negligible. CONCLUSION: The novel coil array is safe, strongly improves signal-to-noise ratio in concurrent TMS/fMRI experiments, enables parallel imaging, and allows for flexible positioning of the TMS on the head while ensuring efficient TMS stimulation due to its ultraslim design.


Asunto(s)
Imagen por Resonancia Magnética/instrumentación , Imagen por Resonancia Magnética/métodos , Estimulación Magnética Transcraneal/instrumentación , Estimulación Magnética Transcraneal/métodos , Adulto , Simulación por Computador , Diseño de Equipo , Femenino , Cabeza/anatomía & histología , Humanos , Masculino , Fantasmas de Imagen
SELECCIÓN DE REFERENCIAS