Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Sci Rep ; 8(1): 14894, 2018 10 05.
Artículo en Inglés | MEDLINE | ID: mdl-30291261

RESUMEN

Intraoperative image-guided surgical navigation for craniospinal procedures has significantly improved accuracy by providing an avenue for the surgeon to visualize underlying internal structures corresponding to the exposed surface anatomy. Despite the obvious benefits of surgical navigation, surgeon adoption remains relatively low due to long setup and registration times, steep learning curves, and workflow disruptions. We introduce an experimental navigation system utilizing optical topographical imaging (OTI) to acquire the 3D surface anatomy of the surgical cavity, enabling visualization of internal structures relative to exposed surface anatomy from registered preoperative images. Our OTI approach includes near instantaneous and accurate optical measurement of >250,000 surface points, computed at >52,000 points-per-second for considerably faster patient registration than commercially available benchmark systems without compromising spatial accuracy. Our experience of 171 human craniospinal surgical procedures, demonstrated significant workflow improvement (41 s vs. 258 s and 794 s, p < 0.05) relative to benchmark navigation systems without compromising surgical accuracy. Our advancements provide the cornerstone for widespread adoption of image guidance technologies for faster and safer surgeries without intraoperative CT or MRI scans. This work represents a major workflow improvement for navigated craniospinal procedures with possible extension to other image-guided applications.


Asunto(s)
Encéfalo , Interpretación de Imagen Asistida por Computador/métodos , Imagenología Tridimensional , Imagen por Resonancia Magnética/métodos , Médula Espinal , Cirugía Asistida por Computador , Animales , Encéfalo/diagnóstico por imagen , Encéfalo/cirugía , Humanos , Imagenología Tridimensional/instrumentación , Imagenología Tridimensional/métodos , Curva de Aprendizaje , Neurocirujanos/educación , Médula Espinal/diagnóstico por imagen , Médula Espinal/cirugía , Cirugía Asistida por Computador/instrumentación , Cirugía Asistida por Computador/métodos , Porcinos
2.
Biomed Opt Express ; 5(3): 895-906, 2014 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-24688822

RESUMEN

In this work, we explored the potential of measuring shear wave propagation using optical coherence elastography (OCE) in an inhomogeneous phantom and carotid artery samples based on a swept-source optical coherence tomography (OCT) system. Shear waves were generated using a piezoelectric transducer transmitting sine-wave bursts of 400 µs duration, applying acoustic radiation force (ARF) to inhomogeneous phantoms and carotid artery samples, synchronized with a swept-source OCT (SS-OCT) imaging system. The phantoms were composed of gelatin and titanium dioxide whereas the carotid artery samples were embedded in gel. Differential OCT phase maps, measured with and without the ARF, detected the microscopic displacement generated by shear wave propagation in these phantoms and samples of different stiffness. We present the technique for calculating tissue mechanical properties by propagating shear waves in inhomogeneous tissue equivalent phantoms and carotid artery samples using the ARF of an ultrasound transducer, and measuring the shear wave speed and its associated properties in the different layers with OCT phase maps. This method lays the foundation for future in-vitro and in-vivo studies of mechanical property measurements of biological tissues such as vascular tissues, where normal and pathological structures may exhibit significant contrast in the shear modulus.

3.
Phys Med Biol ; 59(7): 1589-605, 2014 Apr 07.
Artículo en Inglés | MEDLINE | ID: mdl-24614540

RESUMEN

Breast MRI is frequently performed prior to breast conserving surgery in order to assess the location and extent of the lesion. Ideally, the surgeon should also be able to use the image information during surgery to guide the excision and this requires that the MR image is co-registered to conform to the patient's position on the operating table. Recent progress in MR imaging techniques has made it possible to obtain high quality images of the patient in the supine position which significantly reduces the complexity of the registration task. Surface markers placed on the breast during imaging can be located during surgery using an external tracking device and this information can be used to co-register the images to the patient. There remains the problem that in most clinical MR scanners the arm of the patient has to be placed parallel to the body whereas the arm is placed perpendicular to the patient during surgery. The aim of this study is to determine the accuracy of co-registration based on a surface marker approach and, in particular, to determine what effect the difference in a patient's arm position makes on the accuracy of tumour localization. Obtaining a second MRI of the patient where the patient's arm is perpendicular to body axes (operating room position) is not possible. Instead we obtain a secondary MRI scan where the patient's arm is above the patient's head to validate the registration. Five patients with enhancing lesions ranging from 1.5 to 80 cm(3) in size were imaged using contrast enhanced MRI with their arms in two positions. A thin-plate spline registration scheme was used to match these two configurations. The registration algorithm uses the surface markers only and does not employ the image intensities. Tumour outlines were segmented and centre of mass (COM) displacement and Dice measures of lesion overlap were calculated. The relationship between the number of markers used and the COM-displacement was also studied. The lesion COM-displacements ranged from 0.9 to 9.3 mm and the Dice overlap score ranged from 20% to 80%. The registration procedure took less than 1 min to run on a standard PC. Alignment of pre-surgical supine MR images to the patient using surface markers on the breast for co-registration therefore appears to be feasible.


Asunto(s)
Marcadores Fiduciales , Imagen por Resonancia Magnética/normas , Mastectomía Segmentaria , Cirugía Asistida por Computador , Neoplasias de la Mama/cirugía , Estudios de Factibilidad , Humanos , Procesamiento de Imagen Asistido por Computador
6.
J Magn Reson Imaging ; 34(5): 1212-7, 2011 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-21928381

RESUMEN

PURPOSE: To achieve high-quality unilateral supine breast magnetic resonance imaging (MRI) as a step to facilitate image aiding of clinical applications, which are often performed in the supine position. Contrast-enhanced breast MRI is a powerful tool for the diagnosis of cancer. However, prone patient positioning typically used for breast MRI hinders its use for image aiding. MATERIALS AND METHODS: A fixture and a flexible four-element receive coil were designed for patient-specific shaping and placement of the coil in close conformity to the supine breast. A 3D spoiled gradient sequence was modified to incorporate compensation of respiratory motion. The entire setup was tested in volunteer experiments and in a pilot patient study. RESULTS: The flexible coil design and the motion compensation produced supine breast MR images of high diagnostic value. Variations in breast shape and in tissue morphology within the breast were observed between a supine and a diagnostic prone MRI of a patient. CONCLUSION: The presented supine breast MRI achieved an image quality comparable to diagnostic breast MRI. Since supine positioning is common in many clinical applications such as ultrasound-guided breast biopsy or breast-conserving surgery, the registration of the supine images will aid these applications.


Asunto(s)
Neoplasias de la Mama/patología , Mama/patología , Procesamiento de Imagen Asistido por Computador/métodos , Imagen por Resonancia Magnética/métodos , Neoplasias de la Mama/diagnóstico , Medios de Contraste/farmacología , Femenino , Humanos , Imagenología Tridimensional/métodos , Modelos Estadísticos , Movimiento (Física) , Proyectos Piloto , Reproducibilidad de los Resultados , Respiración , Posición Supina
7.
J Magn Reson Imaging ; 31(2): 328-38, 2010 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-20099345

RESUMEN

PURPOSE: To evaluate three multicoil breast arrays for both conventional and SENSE-accelerated imaging. MATERIALS AND METHODS: Two commercially available 8-element coils and a prototype 16-element coil were compared. One 8-element array had adjustable coils located next to the breast tissue and the other had a fixed coil arrangement; both were designed to allow parallel imaging in the left-right direction. The 16-element coil was designed to have coil sensitivity variation in both the left-right and superior-inferior directions, and also had adjustable coils. Their performance was assessed in terms of signal-to-noise ratio (SNR), g-factor, and uniformity with a custom-built phantom. RESULTS: The 16-element array with adjustable coils provided the highest SNR, while the 8-element coil with a fixed coil arrangement had the best uniformity. All coils performed well for SENSE acceleration in the left-right direction. The 8-element coils did not have the capability for acceleration in the superior-inferior direction across the whole volume. The 16-element coil enabled acceleration in the superior-inferior direction in addition to the left-right direction. CONCLUSION: Smaller, adjustable coil elements located next to breast tissue can provide greater SNR than larger, fixed coil elements. A multicoil breast array with high intrinsic SNR and low g-factors enables high-quality parallel imaging.


Asunto(s)
Mama/anatomía & histología , Aumento de la Imagen/instrumentación , Imagen por Resonancia Magnética/instrumentación , Magnetismo/instrumentación , Transductores , Diseño de Equipo , Análisis de Falla de Equipo , Femenino , Humanos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
8.
Z Med Phys ; 17(2): 118-26, 2007.
Artículo en Alemán | MEDLINE | ID: mdl-17665734

RESUMEN

In static magnetic resonance elastography, the elasticity of an object is determined by measuring the internal displacement between two compression states. To reduce signal loss during the long time delay between application of external deformation and the static compression state, a STEAM sequence with a long mixing time is used This results in long scan times. The aim of this work was the development of a STEAM sequence with a multi-echo-readout, which allows the reduction of scan time and number of necessary external deformations. This new sequence was compared to the standard STEAM sequence on an agarose gel phantom with a hard inclusion. In addition, the elasticity of thermal tissue lesions was investigated, which were induced using high-intensity focused ultrasound (HIFU). During a given measurement time, more acquisitions per image can be taken using the multi-echo-readout. As a result the signal-to-noise ratio is increased and errors in the data become clearly smaller. Drawbacks of. the new sequence are its higher signal loss due to T2-decay and its greater sensitivity against ghosting artefacts caused by k-space segmentation. During the investigation of the thermally-induced lesions, a clear contrast in elasticity between normal tissue and the treated region was observed. Taking advantage of the greater accuracy of the new STEAM sequence, it was shown, that this contrast is significantly larger than the one in conventional MR parameters.


Asunto(s)
Imagen por Resonancia Magnética/métodos , Fantasmas de Imagen , Agar , Elasticidad , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
9.
Invest Radiol ; 41(3): 222-8, 2006 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-16481904

RESUMEN

OBJECTIVES: Exogenous magnetic resonance (MR) contrast media (CM) are used to improve detection and delineation of physiological and pathologic structures. Temporary binding between CM and proteins such as human serum albumin (HSA) may alter the relaxation-enhancing properties of specific contrast agents. In this study, the presence and strength of HSA interaction with different CM was investigated. MATERIAL AND METHODS: Three contrast agents were chosen: Gd-DTPA, Gd-BT-DO3A, and Gd-BOPTA, each of which is known to have a different protein interaction. Samples were prepared using 7 different HSA concentrations, all at a constant CM concentration of 0.5 mmol/L. The relaxation rates, R1 and R2, of each sample were measured at 1.5 T. Virtual docking studies were performed to estimate the number of high affinity-binding sites of Gd-BOPTA and the surface of the HSA dimer. RESULTS: Gd-BOPTA caused the greatest increase in R1 and R2, which followed an exponential dependency with increasing HSA concentration. Between the range of 0 and 7 g/dL of HSA, Gd-DTPA and Gd-BT-DO3A showed a relative change in both relaxation rates of approximately 13% and 22% for R1 and 26% and 30% for R2, respectively. In contrast, Gd-BOPTA demonstrated a relative increase of approximately 108% and 363% for R1 and R2, respectively. Changes of HSA concentration within physiological range (3.5-5.5 g/dL) resulted in an increase of R1 and R2 of approximately 40% when using Gd-BOPTA. The docking study revealed that approximately 10 small hydrophobic pockets exist on the HSA surface where the aromatic tail of Gd-BOPTA can fit in and a stronger noncovalent binding can occur compared with Gd-DTPA and Gd-BT-DO3A. CONCLUSION: Relaxation rates of Gd-BOPTA showed a strong dependency on HSA. In contrast, Gd-DTPA and Gd-BT-DO3A demonstrated little or no relevant dependency. On the basis of these results, the influence of serum protein concentration should be considered in both research studies and in clinical use.


Asunto(s)
Medios de Contraste/farmacocinética , Gadolinio DTPA/farmacocinética , Imagen por Resonancia Magnética/métodos , Meglumina/análogos & derivados , Compuestos Organometálicos/farmacocinética , Albúmina Sérica/farmacocinética , Humanos , Meglumina/farmacocinética , Modelos Moleculares
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...