Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Phys Med ; 102: 88-95, 2022 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-36150316

RESUMEN

PURPOSE: Clinical procedures in a Nuclear Medicine Department produce radioactive liquid and solid waste. Regarding waste release into the environment from an authorised hospital, it is mandatory to verify the compliance with European Directive 2013/59/EURATOM, adopted by the Italian Government via the Legislative Decree 101/2020. METHODS: Different activity release pathways into the environment from Trieste Nuclear Medicine Department have been analysed: liquid waste from patients' excreta discharged by sewage treatment system into the sea, and atmospheric releases following solid waste incineration. Reference models, provided by NCRP and IAEA guidelines, have been implemented to assess the impact of the discharged radioactivity for coastal waters and atmospheric transport conditions. Finally, an accidental fire event occurring in Radiopharmacy Laboratories has been simulated by HotSpot software. RESULTS: Advanced screening models give an effective dose to population of 5.3 · 10-3 µSv/y and 1.4 · 10-4 µSv/y for introduction by sewage system into coastal waters and atmospheric releases by the incinerator, respectively. Workers involved in the maintenance of the sewage treatment plant receive a total annual effective dose of 3.8 µSv/y, while for incinerator staff the total annual exposure is 5.9 · 10-8 µSv/y. For the accidental fire event the maximum total effective dose to an individual results 3.8 · 10-8 Sv with mild wind, and 4.1 · 10-7 Sv with strong wind. CONCLUSIONS: The total annual effective doses estimated to representative person, due to both Nuclear Medicine authorised clinical practices and in case of an accidental fire event, are in compliance with regulatory stipulations provided by Directives.


Asunto(s)
Medicina Nuclear , Aguas del Alcantarillado , Hospitales , Humanos , Dosis de Radiación , Residuos Sólidos
2.
Phys Med ; 91: 28-42, 2021 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-34710789

RESUMEN

PURPOSE: The assessment of low-contrast-details is a part of the quality control (QC) program in digital radiology. It generally consists of evaluating the threshold contrast (Cth) detectability details for different-sized inserts, appropriately located in dedicated QC test tools. This work aims to propose a simplified method, based on a statistical model approach for threshold contrast estimation, suitable for different modalities in digital radiology. METHODS: A home-madelow-contrast phantom, made of a central aluminium insert with a step-wedge, was assembled and tested. The reliability and robustness of the method were investigated for Mammography, Digital Radiography, Fluoroscopy and Angiography. Imageswere analysed using our dedicated software developed on Matlab®. TheCth is expressed in the same unit (mmAl) for all studied modalities. RESULTS: This method allows the collection of Cthinformation from different modalities and equipment by different vendors, and it could be used to define typical values. Results are summarized in detail. For 0.5 diameter detail, Cthresults are in the range of: 0.018-0.023 mmAl for 2D mammography and 0.26-0.34 mmAl DR images. For angiographic images, for 2.5 mm diameter detail, the Cths median values are 0.55, 0.4, 0.06, 0.12 mmAl for low dose fluoroscopy, coronary fluorography, cerebral and abdominal DSA, respectively. CONCLUSIONS: The statistical method proposed in this study gives a simple approach for Low-Contrast-Details assessment, and the typical values proposed can be implemented in a QA program for digital radiology modalities.


Asunto(s)
Mamografía , Intensificación de Imagen Radiográfica , Fantasmas de Imagen , Control de Calidad , Reproducibilidad de los Resultados
3.
Phys Med ; 64: 89-97, 2019 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-31515040

RESUMEN

PURPOSE: To evaluate the feasibility of spatio-temporal generalisation of mathematical methods for protocol optimisation in interventional radiology. MATERIALS AND METHODS: Two model observers were considered:Furthermore, Low Contrast Detectability (LCD) was evaluated with a generalised statistical method by taking into account the noise integration capability of the human eye. A series of two alternative force choices (2AFC) experiments performed by four observers were used to evaluate the reliability of the proposed models. The evaluation of the mathematical methods was performed by comparing their results to the human observer performances in two steps: 1. Firstly, a series of simulated images were used to tune the models 2. In the second phase, tuned models were applied both to simulated images and actual images obtained with a commercial phantom to evaluate detectability scores. RESULTS: Evaluation with simulated images shows a good agreement with 2AFC results (RMSE < 10%). Phantom-based evaluations show a general decrease of such agreement, characterized by an RMSE lower than 16%. CONCLUSIONS: The agreement with human observer experiments supports the feasibility of the proposed generalisations. Thus, they could be introduced in quality control programmes for a deeper protocol-characterisation or for clinical protocol-optimization when dynamic images are involved.


Asunto(s)
Angiografía , Relación Señal-Ruido , Estudios de Factibilidad , Procesamiento de Imagen Asistido por Computador , Fantasmas de Imagen
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA