Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
2.
Sci Rep ; 12(1): 2993, 2022 02 22.
Artículo en Inglés | MEDLINE | ID: mdl-35194070

RESUMEN

The aim of this study was to evaluate influence of baseline imaging features on visual and anatomical outcomes in eyes with PCV treated with anti-VEGF monotherapy. In this prospective study we enrolled participants with treatment-naïve PCV who followed a treat-and-extend protocol using intravitreal aflibercept (IVA) monotherapy. Baseline clinical features evaluatedincluded best corrected visual acuity (BCVA), traditional features such as lesion size, fluid-related OCT parameters and novel parameters using automated software. This included quantitative and qualitative pigment epithelium detachment (PED) parameters [height, volume]; and choroidal parameters. [choroidal thickness (CT), choroidal volume (CV) and choroidal vascularity index (CVI). We evaluated the predictive value of each parameter on visual and anatomical outcome at month 12. We additionally evaluated initial treatment response after 3 monthly injections with respect to month 12 outcomes. Fifty-two eyes from 52 participants were included in the study. The BCVA increased from 61.1 ± 13.2 to 69.6 ± 13.2 early treatment diabetic retinopathy study (ETDRS) letters (p < 0.01) and CRT reduced from 455.7 ± 182.4 µm to 272.7 ± 86.2 (p < 0.01) from baseline to month 12. The proportion of eyes with PED decreased significant from 100% at baseline to 80% at month 12 (p < 0.01). Reduction in the mean maximum height of PED (from 381.3 ± 236.3 µm to 206.8 vs ± 146.4 µm) and PED volume (from 1322 ± 853 nl to 686 ± 593 nl) (p < 0.01) was also noted from baseline to month12. Baseline features associated with better month 12 BCVA included baseline BCVA (ß = - 0.98, 95%CI - 3.38 to - 1.61, p = 0.02) and baseline CRT (ß = - 0.98, 95%CI - 1.56 to - 0.40, p = 0.04) while the disease activity at month12 was significantly associated with lower baseline CRT (366.0 ± 129.5 vs 612.0 ± 188.0 , p < 0.001), lower baseline PED height (242.0 ± 150.0 vs 542.0 ± 298.0 µm, p < 0.01), lower baseline PED volume (0.6 ± 0.3 mm3 vs 2.2 ± 1.3 mm3 vs, p < 0.01), lower proportion with marked CVH (17.9% vs 46.2%, p = 0.02) and lower mean CVI (61.8 ± 1.4 vs 63.0 ± 1.4, p < 0.02). Additionally, a larger decrease in CRT (per 100 nm) and larger PED volume reduction (per 100 nl) at month 3 from baseline were associated with greater BCVA gain and inactive disease. PED-related volumetric parameters have an additional predictive value to traditional biomarkers of disease activity in eyes with PCV undergoing anti-VEGF monotherapy. With increasingly precise quantification, PEDs can be a crucial biomarker in addition to traditional parameters and may aid in retreatment decisions.


Asunto(s)
Neovascularización Coroidal/diagnóstico por imagen , Degeneración Macular/diagnóstico por imagen , Tomografía de Coherencia Óptica/métodos , Anciano , Biomarcadores , Neovascularización Coroidal/tratamiento farmacológico , Femenino , Humanos , Inyecciones Intravítreas , Degeneración Macular/tratamiento farmacológico , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Receptores de Factores de Crecimiento Endotelial Vascular/administración & dosificación , Proteínas Recombinantes de Fusión/administración & dosificación , Desprendimiento de Retina/patología , Epitelio Pigmentado de la Retina/patología
8.
Asia Pac J Ophthalmol (Phila) ; 10(1): 39-48, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-33512827

RESUMEN

PURPOSE: The COVID-19 pandemic has put strain on healthcare systems and the availability and allocation of healthcare manpower, resources and infrastructure. With immediate priorities to protect the health and safety of both patients and healthcare service providers, ophthalmologists globally were advised to defer nonurgent cases, while at the same time managing sight-threatening conditions such as neovascular Age-related Macular Degeneration (AMD). The management of AMD patients both from a monitoring and treatment perspective presents a particular challenge for ophthalmologists. This review looks at how these pressures have encouraged the acceptance and speed of adoption of digitalization. DESIGN AND METHODS: A literature review was conducted on the use of digital technology during COVID-19 pandemic, and on the transformation of medicine, ophthalmology and AMD screening through digitalization. RESULTS: In the management of AMD, the implementation of artificial intelligence and "virtual clinics" have provided assistance in screening, diagnosis, monitoring of the progression and the treatment of AMD. In addition, hardware and software developments in home monitoring devices has assisted in self-monitoring approaches. CONCLUSIONS: Digitalization strategies and developments are currently ongoing and underway to ensure early detection, stability and visual improvement in patients suffering from AMD in this COVID-19 era. This may set a precedence for the post COVID-19 new normal where digital platforms may be routine, standard and expected in healthcare delivery.


Asunto(s)
COVID-19/epidemiología , Atención a la Salud/métodos , Técnicas de Diagnóstico Oftalmológico , Degeneración Macular/diagnóstico , SARS-CoV-2 , Telemedicina/métodos , Tecnología Digital , Humanos , Degeneración Macular/terapia
9.
Eye (Lond) ; 35(8): 2254-2259, 2021 08.
Artículo en Inglés | MEDLINE | ID: mdl-33116263

RESUMEN

AIM: The aim of this study is to evaluate the frequency and types of anti-retinal autoantibodies (ARAs) in highly myopic patients and to explore any association between ARAs and the severity of myopic macular degeneration (MMD). METHODS: This was a clinic-based study of 16 patients with high myopia (spherical equivalent worse than -6 dioptres or axial length (AL) ≥ 26.5 mm) recruited from the High Myopia clinic of the Singapore National Eye Centre. MMD was graded from fundus photographs according to the Meta-analysis for Pathologic Myopia (META-PM) classification. Severe MMD was defined as META-PM category 3 or 4. AL and logarithm of the minimal angle of resolution (logMAR) best corrected visual acuity (BCVA) were measured. Sera were obtained from subjects and analysed for the presence of ARAs with the western blot technique. RESULTS: The mean AL was significantly longer in patients with severe MMD (n = 8) than those without severe MMD (n = 8) (31.50 vs. 28.51, p = 0.005). There was at least one ARA identified in all patients. The most common ARA was anti-carbonic anhydrase II (anti-CAII), present in nine patients (56.3%). Anti-CAII was detected in more patients with severe MMD than those without (75 vs. 37.5%, p = 0.32). LogMar BCVA was also worse in subjects with anti-CAII (0.5 ± 0.38 vs. 0.22 ± 0.08, p = 0.06). The number of ARAs significantly correlated with increasing AL (r = 0.61, p = 0.012). CONCLUSIONS: ARAs are prevalent in patients with high myopia, and this increases with increasing AL. In particular, anti-CAII antibodies were highly prevalent in patients with severe MMD, suggesting that ARAs may be associated with MMD. Further studies are necessary to confirm these observations in larger cohorts.


Asunto(s)
Degeneración Macular , Miopía Degenerativa , Autoanticuerpos , Humanos , Proyectos Piloto , Estudios Retrospectivos , Agudeza Visual
10.
Int J Ophthalmol ; 9(6): 920-4, 2016.
Artículo en Inglés | MEDLINE | ID: mdl-27366698

RESUMEN

This is a review education paper on the current ophthalmology simulators utilized worldwide for undergraduate and postgraduate training. At present, various simulators such as the EYE Exam Simulator (Kyoto Kagaku Co. Ltd., Kyoto, Japan), Eyesi direct ophthalmoscope simulator (VRmagic, GmbH, Mannheim, Germany), Eyesi indirect ophthalmoscope simulator (VRmagic, GmbH, Mannheim, Germany) and Eyesi cataract simulators (VRmagic, GmbH, Mannheim, Germany). These simulators are thought to be able to reduce the initial learning curve for the ophthalmology training but further research will need to be conducted to assess the effectiveness of the simulation-assisted Ophthalmology training. Future research will be of great value to assess the medical students and residents' responses and performance regarding the usefulness of the individual eye simulator.

11.
J Diabetes Sci Technol ; 10(2): 282-94, 2016 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-26830491

RESUMEN

Due to the increasing prevalence of diabetes mellitus, demand for diabetic retinopathy (DR) screening platforms is steeply increasing. Early detection and treatment of DR are key public health interventions that can greatly reduce the likelihood of vision loss. Current DR screening programs typically employ retinal fundus photography, which relies on skilled readers for manual DR assessment. However, this is labor-intensive and suffers from inconsistency across sites. Hence, there has been a recent proliferation of automated retinal image analysis software that may potentially alleviate this burden cost-effectively. Furthermore, current screening programs based on 2-dimensional fundus photography do not effectively screen for diabetic macular edema (DME). Optical coherence tomography is becoming increasingly recognized as the reference standard for DME assessment and can potentially provide a cost-effective solution for improving DME detection in large-scale DR screening programs. Current screening techniques are also unable to image the peripheral retina and require pharmacological pupil dilation; ultra-widefield imaging and confocal scanning laser ophthalmoscopy, which address these drawbacks, possess great potential. In this review, we summarize the current DR screening methods using various retinal imaging techniques, and also outline future possibilities. Advances in retinal imaging techniques can potentially transform the management of patients with diabetes, providing savings in health care costs and resources.


Asunto(s)
Retinopatía Diabética/diagnóstico por imagen , Técnicas de Diagnóstico Oftalmológico , Femenino , Humanos , Masculino , Tamizaje Masivo/métodos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...