1.
Int J Implant Dent ; 4(1): 33, 2018 Nov 02.
Artículo en Inglés | MEDLINE | ID: mdl-30386925

RESUMEN

BACKGROUND: The performance of dental implants in controlled clinical studies is often investigated in homogenous populations. Observational studies are necessary to evaluate the outcome of implant restorations placed in real-life situations, according to standard practice, and to assess the needs of the patients. The aim of this non-interventional study was to reveal the survival, success, and general performance of CAMLOG SCREW-LINE implants and their restorations in daily dental practice. METHODS: Seventeen private practices across five countries participated in this prospective multicenter study. Patients received implants in the maxilla and mandible which were restored either with platform-matching or platform-switching abutments. Patients were followed-up for up to 5 years post-loading. Radiographs and clinical parameters were evaluated and patient satisfaction was evaluated. RESULTS: From a total of 196 patients planned, 185 patients with 271 implants were restored with abutments and fulfilled the follow-up inclusion criteria. Three implant failures were recorded, resulting in a cumulative survival rate of 98.6% after 5 years post-loading. One persistent complication of peri-implantitis occurred. The soft tissue health remained stable, and the papilla height improved after loading. At 5-year follow-up, the mean crestal bone loss was - 0.28 ± 0.60 mm; over 99% of patients reported satisfaction with the restoration as excellent or good. CONCLUSIONS: Implants placed and restored with both platform-matching and platform-switching abutments in daily dental private practice achieved excellent clinical outcomes with highly satisfied patients after 5 years of function, confirming the results obtained in well-controlled clinical trials.

2.
Clin Oral Implants Res ; 20(11): 1231-9, 2009 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-19709060

RESUMEN

OBJECTIVES: Although implants with a roughened surface are widely used today, little is known about the long-term effect of a roughened surface compared with the conventional machined surface on clinical and radiographic parameters. The purpose of this study is to investigate the long-term differences between moderately rough (tioblasted) titanium implants and minimally rough machined/turned surfaces with respect to marginal bone resorption and the peri-implant soft tissues in the same patient. MATERIAL AND METHODS: In 20 fully edentulous patients, with severely resorbed mandibles, a total of 80 Astra Tech dental implants were placed in the mandible to support a bar construction with a full overdenture. In each patient two minimally rough-surfaced (turned) and two moderately rough-surfaced (tioblast) implants were placed alternately. Clinical evaluation was carried out at base line (prosthetic installation), 6 months, 1, 2, 3, 4, 5 and 12 years. Radiographic evaluation using standardized individual filmholders was carried out at base line (prosthetic installation), 6 months, 1, 5 and 12 years. RESULTS: In two patients, during the abutment surgery, one turned implant showed insufficient osseointegration and was replaced. One implant showed an abutment fracture after 9 years and was kept as a sleeper. From base line up to 12 years, no implant was lost. No significant differences were found between both implant surfaces concerning the clinical parameters such as plaque, calculus, bleeding and probing pocket depth. The mean (SD) marginal bone changes up to 12 years varied between -0.11 and +0.01 mm for the turned and -0.2 and +0.01 mm for the tioblast implants. No significant difference in marginal bone loss was found between both implant surfaces. CONCLUSION: We conclude that after 12 years of follow-up, no differences could be found between the turned and the tioblasted implants, both for soft and for hard tissue parameters.


Asunto(s)
Pilares Dentales , Implantes Dentales , Diseño de Prótesis Dental , Prótesis Dental de Soporte Implantado , Arcada Edéntula/rehabilitación , Adulto , Anciano , Pérdida de Hueso Alveolar/complicaciones , Pilares Dentales/efectos adversos , Implantes Dentales/efectos adversos , Índice de Placa Dental , Fracaso de la Restauración Dental , Retención de Dentadura/instrumentación , Dentadura Completa Inferior , Prótesis de Recubrimiento , Método Doble Ciego , Femenino , Humanos , Análisis de Intención de Tratar , Arcada Edéntula/complicaciones , Estudios Longitudinales , Masculino , Mandíbula/diagnóstico por imagen , Persona de Mediana Edad , Oseointegración , Índice Periodontal , Radiografía , Estadísticas no Paramétricas , Propiedades de Superficie , Titanio
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA