1.
Polymers (Basel) ; 16(11)2024 May 25.
Artículo en Inglés | MEDLINE | ID: mdl-38891449

RESUMEN

BACKGROUND: A critical-sized bone defect (CsBD) is considered one that will not heal spontaneously and requires reconstruction. This study aims to compare the results of using different bone reconstructive techniques and to study the potential of platelet-rich fibrin (PRF) to enhance the healing properties of a bone substitute (BS). METHODS: In this experimental study on rats, the treatment of critical-sized bone defects was carried out by analysing four groups: a control group in which the bone defect was left empty; a group treated with Bio-Gen®; another group in which the defect was treated with PRF in combination with Bio-Gen®; and the last that was treated with autologous bone graft (ABG). The defects were evaluated by microcomputed tomography (µCT) and then histomorphometrically. RESULTS: From both the histological and imagistic point of view, the best results were registered in the ABG group, followed by the group treated with Bio-Gen® with PRF, Bio-Gen® group, and control group, with statistically significant differences. CONCLUSIONS: A 5 mm defect in the rat radius can be considered critical. ABG showed the best results in treating the bone defect. PRF significantly enhanced the efficacy of Bio-Gen®.

2.
J Pers Med ; 13(12)2023 Dec 13.
Artículo en Inglés | MEDLINE | ID: mdl-38138932

RESUMEN

Numerous studies report the success and outcomes of the total knee arthroplasty (TKA); however, few papers present patients with knee osteoarthritis and ipsilateral hip fusion. One controversy when treating patients requiring a TKA with prior ipsilateral hip fusion is whether to first perform a total hip arthroplasty (THA) of the fused hip, followed by the ipsilateral TKA, or to proceed with the TKA without replacing the hip; studies suggest that the position of the fused hip is a key factor when making this therapeutical decision. In addition, performing a TKA in patients with an ipsilateral fused hip may require modifications to the surgical technique generated by the lack of joint mobility in the hip. We identified 12 studies encompassing 30 patients with hip fusion and ipsilateral TKA in current orthopedic literature, but only six offered insights on patient positioning on the operating table during surgery. This study aims to review the current literature on patients with knee osteoarthritis and prior ipsilateral hip fusion and to present some technical considerations when performing a TKA on a 75-year-old patient with hip ankylosis who underwent a total ipsilateral knee arthroplasty in our clinic.

3.
Arch Clin Cases ; 10(3): 114-118, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37655164

RESUMEN

Peri-implant fractures have gained increasing importance in orthopedics as the number of surgical procedures involving orthopedic implants rises globally. These fractures pose a significant challenge in terms of diagnosis, treatment, and postoperative management. They manifest as stress fractures distal to the implant site. Developing an effective treatment strategy involves evaluating multiple influencing factors. This article presents a rare case of a peri-implant distal radius fracture in a 63-year-old man, with no comorbidities, resulting from a car accident, classified as C1U in the Michele D'Arienzo system. The surgical intervention included plate fixation for the radius and wire fixation for the ulna. The wire was used for ulna instead of a plate, due to skin injuries, with good results. As life expectancy rises and individuals remain active in their elder years, the incidence of peri-implant fractures is expected to increase. Factors such as the implant type, surgeon's approach, and patient-specific elements may influence peri-implant fracture occurrence. The widespread use of plate fixation for distal radius fractures may also contribute to a parallel increase in such fractures. Providing detailed context and specific case presentation allows better understanding and implications for clinical practice.

4.
Polymers (Basel) ; 15(15)2023 Aug 02.
Artículo en Inglés | MEDLINE | ID: mdl-37571172

RESUMEN

One of the most popular and effective orthopedic surgical interventions for treating a variety of hip diseases is total hip arthroplasty. Despite being a radical procedure that involves replacing bone and cartilaginous surfaces with biomaterials, it produces excellent outcomes that significantly increase the patient's quality of life. Patient factors and surgical technique, as well as biomaterials, play a role in prosthetic survival, with aseptic loosening (one of the most common causes of total hip arthroplasty failure) being linked to the quality of biomaterials utilized. Over the years, various biomaterials have been developed to limit the amount of wear particles generated over time by friction between the prosthetic head (metal alloys or ceramic) and the insert fixed in the acetabular component (polyethylene or ceramic). An ideal biomaterial must be biocompatible, have a low coefficient of friction, be corrosion resistant, and have great mechanical power. Comprehensive knowledge regarding what causes hip arthroplasty failure, as well as improvements in biomaterial quality and surgical technique, will influence the survivability of the prosthetic implant. The purpose of this article was to assess the benefits and drawbacks of various biomaterial and friction couples used in total hip arthroplasties by reviewing the scientific literature published over the last 10 years.

5.
J Pers Med ; 13(4)2023 Mar 27.
Artículo en Inglés | MEDLINE | ID: mdl-37108973

RESUMEN

The C-Nail® system is a novel intramedullary fixation method for displaced intra-articular calcaneal fractures. The aim of this study was to evaluate the biomechanical performance of the C-Nail® system and compare it with conventional plate fixation for the treatment of displaced intra-articular calcaneal fractures using finite element analysis. The geometry of a Sanders type-IIB fracture was constructed using the computer-aided design software Ansys SpaceClaim. The C-Nail® system (Medin, Nové Mesto n. Morave, Czech Republic) and the calcaneal locking plate (Auxein Inc., 35 Doral, Florida) and screws were designed according to the manufacturer specifications. Vertical loading of 350 N and 700 N were applied to the subtalar joint surfaces to simulate partial weight bearing and full weight bearing. Construct stiffness, total deformation, and von Mises stress were assessed. The maximum stress on the C-Nail® system was lower compared with the plate (110 MPa vs. 360 MPa). At the bone level the stress was found to have higher values in the case of the plate compared to the C-Nail® system. The study suggests that the C-Nail® system can provide sufficient stability, making it a viable option for the treatment of displaced intra-articular calcaneal fractures.

6.
J Clin Med ; 11(24)2022 Dec 08.
Artículo en Inglés | MEDLINE | ID: mdl-36555918

RESUMEN

Background: Knee osteoarthritis (KOA) is a chronic degenerative pathology that is associated with multiple risk factors such as age, sex, obesity, or metabolic syndrome (MetS). The present clinical trial aimed to investigate the influence of the environment of origin, body mass index (BMI), and MetS parameters on the KOA differentiated degrees. Methods: 85 patients were admitted for the clinical study. The KOA presence was investigated using X-rays analysis. The Kellgren−Lawrence classification (KL) of the KOA severity and the MetS characteristic parameters using freshly collected blood were performed for each patient. All data collected were used for ANOVA statistic interpretation. Results: The total cholesterol and glycemia were found to be statistically significant (p < 0.028, and p < 0.03, respectively), with a high level in patients with severe KOA compared to healthy ones. Patients from rural regions are 5.18 times more prone to develop severe KOA when compared to ones from urban areas. Conclusions: The results of the statistical analysis confirmed the correlation between the incidence and severity of KOA and the influence of increased values of BMI, glycemia, triglycerides, and total cholesterol. The investigations revealed a statistically significant influence of the environment of origin on the KOA degree of the patients.

7.
Healthcare (Basel) ; 10(6)2022 May 27.
Artículo en Inglés | MEDLINE | ID: mdl-35742044

RESUMEN

Thrombophilia, also called hypercoagulability or prothrombotic condition, usually reflects a certain imbalance that occurs either in the coagulation cascade or in the anticoagulation/fibrinolytic system. A similar imbalance may be induced by severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). Thrombotic complications are associated with multiorgan failure and increased mortality. In this context, activation of coagulation and thrombocytopenia appeared as prognostic markers in COVID-19. Our work provides a structured and updated analysis of inherited thrombophilia and its involvement in COVID-19, emphasizing the importance of diagnosing and initiating thromboprophylaxis. Since the state of hypercoagulation is directly correlated with COVID-19, we consider that studies on the genetic profiles of proteins involved in thrombophilia in patients who have had COVID-19 and thrombotic events are of great importance, both in treating and in preventing deaths due to COVID-19.

8.
Exp Ther Med ; 23(3): 198, 2022 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-35126701

RESUMEN

Bicondylar tibial plateau fractures pose many challenges in surgical treatment. The aim of the present study was to analyze three methods of reduction, single medial, single lateral, and dual plating, for the treatment of a bicondylar tibial plateau fracture, through finite element analysis (FEA). A simple metaphyseal fracture, type C1.1 (AO-41) was modeled on a CT-derived 3D model of the knee. Lateral and medial proximal tibial polyaxial plates with screws were modeled and placed accordingly for the three methods of reduction. Simulation of physiological type loading corresponding to the maximal weight acceptance phase during a slow walking gait cycle was performed using FEA. Values of stress and strain were recorded near the fracture lines. Dual plating provided a decrease of stress and strain in the tibial plateau area. However, the differences in the values among the three cases were small. The stress concentration areas were located in the vicinity of the fracture, predominantly in the area of the tibial plateau. Considering the limitations of the present study, the results revealed that dual plating leads to smaller stress and strain values near the fracture lines in the tibial plateau area. However, values obtained for single lateral plating are close in range. Considering the complexity of the surgical approach for dual plating, single lateral plating may be a solution for good reduction with fewer surgical risks and complications. Further studies on the C1.1 fracture (AO-41) are needed to analyze the complex issue of reducing and stabilizing such a fracture and to characterize the postoperative state while providing predictable parameters for an optimal result.

9.
Exp Ther Med ; 23(3): 202, 2022 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-35126705

RESUMEN

Biomechanical testing is a necessity given the development of novel implants used in the osteosynthesis of hip fractures. The purpose of biomechanical testing is to recreate realistic conditions similar to the in vivo conditions. Although biomechanical testing of hip arthroplasty has been standardized since the 1970s, there is no consensus at present on testing methodology for osteosynthesis of hip fractures. Most biomechanical studies examining the fractures of the proximal femur in order to optimize implants opt for loading the bone-implant ensemble directly on the femoral head or using a metallic loading part. This loading technique fails to perform a mechanical stress distribution similar to in vivo conditions, which could alter the outcome. The present study aimed to design loading/unloading cups with mechanical properties that resemble those of the cartilage at the hip level. Through the impression and scanning of the cast models obtained, a digital 3D model was created in STL format and this was processed in order to obtain the computer numerical control (CNC) trajectories of the printing head. For prototyping using additive manufacturing technology, a thermoplastic polymer with biochemical properties, such as tensile strength, that resemble those of the adult hip and a Stratasys FORTUS 250 mc CNC machine were used. Loading/unloading cups with similar anatomy and biomechanical forces compared with those of the adult hip were created, which allowed the experimental simulation of the conditions during walking.

10.
Diagnostics (Basel) ; 13(1)2022 Dec 21.
Artículo en Inglés | MEDLINE | ID: mdl-36611305

RESUMEN

Haemophilia is a rare genetic disorder, that results from various degrees of deficiency of coagulation factor VIII (haemophilia A), or factor IX (haemophilia B), with an X-linked transmission. The patients affected are in the majority of cases males (who inherit the affected X-chromosome from the maternal side), with rare cases of females with haemophilia (FVIII or FIX < 40 IU/dL), situations in which both X-chromosomes are affected, or one is affected, and the other one is inactive (known as carrier). The hypocoagulable state due to the deficiency of clotting factors, manifests as an excessive, recurrent tendency to bleeding, which positively correlates with plasmatic levels. Severe haemophilia results in hemarthrosis, although recent data have shown that moderate or even mild disease can lead to joint bleeding. Recurrent episodes of haemorrhages, usually affecting large joints such as knees, elbows, or ankles, lead to joint remodelling and subsequent haemophilic arthropathy, which may require arthroplasty as a last therapeutic option. Orthopaedic patients have the highest risk among all for deep vein thrombosis (DVT) and venous thromboembolism (VTE) with morbid and potentially fatal consequences. While for the rest of the population thromboprophylaxis in orthopaedic surgery is efficient, relatively safe, and widely used, for patients with haemophilia who are considered to have a low thromboembolic risk, there is great controversy. The great heterogeneity of this particular population, and the lack of clinical trials, with only case reports or observational studies, makes thromboprophylaxis in major orthopaedic surgery a tool to be used by every clinician based on experience and case particularities. This review aims to briefly summarise the latest clinical data and to offer an insight into the current recommendations that readers would find useful in daily practice.

11.
Exp Ther Med ; 22(5): 1315, 2021 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-34630669

RESUMEN

Biocompatibility is one of the mandatory requirements for the clinical use of biomaterials in orthopedics. It refers to the ability of a biomaterial to perform its function without eliciting toxic or injurious effects on biological systems but producing an appropriate host response in a specific case. Today, the biocompatibility concept includes not only bio-inertia, but also biofunctionality and biostability. High biocompatibility and functional properties are highly desirable for new biomaterials. The chemical, mechanical, structural properties of biomaterials, their interaction with biological environment or even the methodology of assessment can influence the biocompatibility. The biological evaluation of biomaterials includes a broad spectrum of in vitro and in vivo tests related to the cytocompatibility, genotoxicity, sensitization, irritation, acute and chronic toxicity, hemocompatibility, reproductive and developmental toxicitity, carcinogenicity, implantation and degradation as specified in different international standards. A brief review of the main assays used in the biocompatibility testing of orthopedic biomaterials is presented. In addition, their main biocompatibility issues are overviewed.

12.
Exp Ther Med ; 22(3): 995, 2021 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-34345277

RESUMEN

Hemophilia is a hereditary coagulopathy caused by factor VIII (hemophilia type A) or by coagulation factor IX (hemophilia type B) dysfunction, characterized by an increased bleeding predisposition, which is either spontaneous or secondary to minimal trauma. Currently, hemophilia may also be considered an 'orthopedic' condition, due to the fact that it affects the musculoskeletal system of most hemophilic patients. In recent years, constant prophylaxis using coagulation factors has led to a significant improvement in the hemophilic patient's quality of life, by reducing both life-threatening hemorrhagic phenomena, as well as the occurrence of chronic complications. Nevertheless, progressive joint bleeding remains unavoidable in this category of patients, and the onset of chronic arthropathy with secondary motor deficiency remains the main complication with an invalidating character. In such cases, orthopedic management is imperative; osteoarticular complications being managed most often with the help of conservative or surgical techniques. The purpose of this review is to provide an overview of modern orthopedic practices which are useful in the management of hemophilic patients suffering from osteoarticular disorders.

13.
Exp Ther Med ; 20(6): 207, 2020 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-33123236

RESUMEN

Haemophilia is an inherited disease that requires a different approach in order to evaluate, monitor and treat patients. Despite the great advances in therapeutic agents that have emerged, reports on the impact of monitoring outcomes on treatment decisions are rarely presented. Haemophilia A and haemophilia B are inherited bleeding disorders caused by deficiencies in blood clotting factor proteins. A systematic review was performed to identify literature reports on the current practices in haemophilic patients undergoing orthopedic surgery. The best therapy for haemophilic patients consists in performing primary prophylaxis to prevent joint bleeding and other complications. Besides the primary prophylaxis, thromboprophylaxis is used to prevent venous thrombosis in patients with hemophilia who undergo surgical orthopedic procedures. Further research is needed to better manage the pharmacologic approaches in haemophilic patients undergoing orthopedic surgery. Although patients with haemophilia present low risk for thromboembolic complications, such events have been reported in surgical procedures. The recommendations in patients with haemophilia are considerably variable in the current guidelines and clinical practice. The best therapy for haemophilic patients consists in performing primary prophylaxis to prevent joint bleeding and other complications.

14.
Int Orthop ; 37(4): 729-33, 2013 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-23361936

RESUMEN

Pigmented villonodular synovitis (PVNS) is a rare, benign proliferative disease of the synovial tissue that affects a single joint or a tendon sheath. Data from the literature present only a few cases of multifocal PVNS. This paper presents multifocal PVNS in the adult. This disease can affect bilateral shoulders, hips and knees. The diagnosis may be delayed by the slow evolution of the disease (up to ten years); some patients may be seen with late-stage degenerative joints, serious complications, painful and functionally uncompensated, with significant locomotion deficit. PVNS requires a radical treatment with prosthetic arthroplasty associated with synovectomy. Complex imaging (X-Rays, magnetic resonance imaging (MRI), ultrasound) and macroscopic appearance of the lesions during surgery confirms the clinical diagnosis of multifocal PVNS with secondary bone lesions. Histology marks the final diagnosis of multifocal PVNS. The postoperative results are good, with recovery in functional parameters of the joints with endoprosthesis.


Asunto(s)
Sinovitis Pigmentada Vellonodular/patología , Sinovitis Pigmentada Vellonodular/cirugía , Adulto , Artroplastia , Humanos , Imagen por Resonancia Magnética , Sinovectomía , Membrana Sinovial/diagnóstico por imagen , Membrana Sinovial/patología , Sinovitis Pigmentada Vellonodular/diagnóstico , Ultrasonografía