Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
J Dent Sci ; 17(2): 1030-1034, 2022 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-35756796

RESUMEN

Background/purpose: Bioceramic tetracalcium phosphate (TTCP) is used as a surface modifier on the implant surface and the clinical studies on this surface modification are still limited. The objective of this clinical study was to investigate short-term implant stability of titanium implant surfaces being modified through sandblasting and acid etching (SLA), followed by TTCP sintered bioceramic anchoring. Materials and methods: A total of 20 patients who had single tooth space were included in this study. Surface modification by SLA plus with TTCP on Ti implants with a diameter of 4.0 mm and lengths of 10 and 11.5 mm were placed. Implant stability quotient (ISQ) value was measured immediately (ISQ0) and one month (ISQ1), two months (ISQ2), three months (ISQ3), and four months (ISQ4) after implantation. Subgroup analysis was defined to location (maxilla, mandible) and bone density (soft or hard bone). Statistical analysis was performed using Friedman test and Mann-Whitney U test. Results: The mean ISQ values with standard deviation at the different time points of ISQ0 to ISQ4 were 60.03 ± 14.12, 53.48 ± 15.24, 58.91 ± 14.43, 63.14 ± 12.22, and 63.50 ± 13.61, respectively. The results showed significant differences between the ISQ1 and ISQ3 groups and between the ISQ1 and ISQ4 groups. On the other hand, there was no statistical differences between the maxilla and mandible as well as between soft and hard bone types in all implant groups. Conclusion: TTCP/titanium implant showed favorable stability in short-term ISQ values over 4 months. The locations and bone types demonstrated no effect on implant stability.

2.
Clin Implant Dent Relat Res ; 23(4): 635-643, 2021 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-34288341

RESUMEN

BACKGROUND: Different designs of surgical drilling systems have been developed for the purpose of static Computer-Assisted Implant Surgery (sCAIS), but there is at present little understanding of how design principles affect the accuracy of implant placement. PURPOSE: The aim of this in vitro study was to compare the accuracy of implant placement among five drilling systems of sCAIS in a controlled experimental setting. MATERIALS AND METHODS: Twenty-five 3D printed models with two edentulous bilateral premolar spaces were allocated to five different drilling systems: group A: sleeve-in-sleeve, group B: sleeve-in-sleeve with self-locking, group C: mounted sleeve-on-drill, group D: integrated sleeve-on-drill with metal sleeve in the guide, group E: integrated sleeve-on-drill without metal sleeve. Models were scanned with CBCT and optical scanner. All implants were digitally planned and 10 implants placed with sCAIS in each group. Postoperative 3D deviation of placed vs planned position was measured by means of platform, apex and angular deviation. Data was analyzed using Kruskal-Wallis test (P ≤ .05). Pairwise comparisons were tested with Dunn's test with adjusted P values. RESULTS: The overall platform deviation ranged from 0.42 ± 0.12 mm (group B) to 1.18 ± 0.19 mm (group C). The overall apex deviation ranged from 0.76 ± 0.22 mm (group B) to 1.95 ± 0.48 mm (group D). The overall angular deviation ranged from 2.50 ± 0.89 degree (group B) to 5.30 ± 1.04 degree (group E). Group A and B showed significantly less angular deviation than groups D and E (P < .05). There was no statistically significant differences in all parameters between group A and B, as well as between group D and E (P > .05). CONCLUSIONS: Significant differences were found with regards to accuracy among the five sCAIS systems tested, suggesting that the drilling protocol, the devices used and the design principles of the guides could influence the accuracy of implant placement.


Asunto(s)
Implantes Dentales , Cirugía Asistida por Computador , Diseño Asistido por Computadora , Computadores , Tomografía Computarizada de Haz Cónico , Implantación Dental Endoósea , Imagenología Tridimensional
3.
Nutr Cancer ; 69(6): 862-872, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-28718681

RESUMEN

Suitable diet for cancer survivors remains an unresolved challenge. Increased glucose utilization is a hallmark of various cancers. Therefore, alternative carbohydrate supplying normal tissue but retarding cancer growth is needed. This study investigated the effect of sugar alcohols on the proliferation of oral cancer cells compared to nontransformed cells and explored the mechanism. Six oral squamous cell carcinoma (CAL-27, FaDu, SCC4, SCC9, SCC15, and SCC25) and one nontransformed oral keratinocyte (OKF6/TERT2) lines were cultured in media containing 1 mg/ml glucose and 5.8 mg/ml xylitol or sorbitol, yielding equal energy input to control group (4.5 mg/ml glucose). Partial substitution of glucose with sugar alcohols especially xylitol significantly suppressed proliferation of oral cancer but not nontransformed cells. Despite the addition of isocaloric quantities of the sugars, cancer cells exposed to low glucose plus xylitol had retarded ATP generation and decreased activity of phosphofructokinase (PFK), the rate-limiting enzyme in glycolysis. Furthermore, D-xylulose, its key metabolic intermediate, enhanced the anticancer effect of xylitol. These findings suggested a selective anticancer activity of xylitol and the potential mechanism involving inhibition of glucose utilization. Partial substitution of glucose with xylitol may be a proper nutrient for oral cancer survivors, deserving further investigation in animal and clinical settings.


Asunto(s)
Proliferación Celular/efectos de los fármacos , Glucosa/farmacología , Glucólisis/efectos de los fármacos , Xilitol/farmacología , Animales , Línea Celular Tumoral , Medios de Cultivo/química , Humanos , Ácido Láctico/metabolismo , Ratones , Neoplasias de la Boca , Fosfofructoquinasas/genética , Fosfofructoquinasas/metabolismo , Sorbitol/farmacología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA