Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
1.
Laeknabladid ; 107(11): 529-533, 2021 Nov.
Artículo en Islandés | MEDLINE | ID: mdl-34704966

RESUMEN

Spontaneous subarachnoid haemorrhage is characterized by extravasation of blood into the subarachnoid space without a preceding trauma. The leading cause is a ruptured intracranial aneurysm. Serious neurologic complications can occur, such as rebleeding, cerebral vasospasm and delayed cerebral ischemia. Subarachnoid haemorrhage is a serious condition with a high mortality rate and those who survive often suffer long-term consequences. Prevention of rebleeding by aneurysm repair is essential and guidelines recommend this procedure should be done as soon as possible or within 72 hours. Management requires intensive care with emphasis on accurate blood pressure control, maintaining normal fluid and electrolyte balance and monitoring the level of consciousness. All patients should be treated with the calcium channel blocker nimodipine to reduce the risk of vasospasm and delayed cerebral ischemia which are among the most serious complications of subarachnoid haemorrhage.


Asunto(s)
Aneurisma Roto , Aneurisma Intracraneal , Hemorragia Subaracnoidea , Vasoespasmo Intracraneal , Cuidados Críticos , Humanos , Hemorragia Subaracnoidea/diagnóstico , Hemorragia Subaracnoidea/terapia , Vasoespasmo Intracraneal/diagnóstico , Vasoespasmo Intracraneal/etiología , Vasoespasmo Intracraneal/prevención & control
2.
Diagnostics (Basel) ; 11(8)2021 Aug 04.
Artículo en Inglés | MEDLINE | ID: mdl-34441347

RESUMEN

In emergency settings, fast access to medical imaging for diagnostic is pivotal for clinical decision making. Hence, a need has emerged for solutions that allow rapid access to images on small mobile devices (SMD) without local data storage. Our objective was to evaluate access times to full quality anonymized DICOM datasets, comparing standard access through an authorized hospital computer (AHC) to a zero-footprint teleradiology technology (ZTT) used on a personal computer (PC) or SMD using national and international networks at a regional neurosurgical center. Image datasets were sent to a senior neurosurgeon, outside the hospital network using either an AHC and a VPN connection or a ZTT (Image Over Globe (IOG)), on a PC or an SMD. Time to access DICOM images was measured using both solutions. The mean time using AHC and VPN was 250 ± 10 s (median 249 s (233-274)) while the same procedure using IOG took 50 ± 8 s (median 49 s (42-60)) on a PC and 47 ± 20 s (median 39 (33-88)) on a SMD. Similarly, an international consultation was performed requiring 23 ± 5 s (median 21 (16-33)) and 27 ± 1 s (median 27 (25-29)) for PC and SMD respectively. IOG is a secure, rapid and easy to use telemedicine technology facilitating efficient clinical decision making and remote consultations.

3.
Sci Rep ; 10(1): 7522, 2020 05 05.
Artículo en Inglés | MEDLINE | ID: mdl-32371880

RESUMEN

The combination of navigation and robotics in spine surgery has the potential to accurately identify and maintain bone entry position and planned trajectory. The goal of this study was to examine the feasibility, accuracy and efficacy of a new robot-guided system for semi-automated, minimally invasive, pedicle screw placement. A custom robotic arm was integrated into a hybrid operating room (OR) equipped with an augmented reality surgical navigation system (ARSN). The robot was mounted on the OR-table and used to assist in placing Jamshidi needles in 113 pedicles in four cadavers. The ARSN system was used for planning screw paths and directing the robot. The robot arm autonomously aligned with the planned screw trajectory, and the surgeon inserted the Jamshidi needle into the pedicle. Accuracy measurements were performed on verification cone beam computed tomographies with the planned paths superimposed. To provide a clinical grading according to the Gertzbein scale, pedicle screw diameters were simulated on the placed Jamshidi needles. A technical accuracy at bone entry point of 0.48 ± 0.44 mm and 0.68 ± 0.58 mm was achieved in the axial and sagittal views, respectively. The corresponding angular errors were 0.94 ± 0.83° and 0.87 ± 0.82°. The accuracy was statistically superior (p < 0.001) to ARSN without robotic assistance. Simulated pedicle screw grading resulted in a clinical accuracy of 100%. This study demonstrates that the use of a semi-automated surgical robot for pedicle screw placement provides an accuracy well above what is clinically acceptable.


Asunto(s)
Procedimientos Quirúrgicos Robotizados/métodos , Columna Vertebral/cirugía , Anciano , Anciano de 80 o más Años , Realidad Aumentada , Cadáver , Tomografía Computarizada de Haz Cónico , Estudios de Factibilidad , Femenino , Humanos , Masculino , Persona de Mediana Edad , Quirófanos , Tornillos Pediculares , Reproducibilidad de los Resultados , Procedimientos Quirúrgicos Robotizados/instrumentación , Columna Vertebral/diagnóstico por imagen
4.
Biomed Opt Express ; 10(11): 5905-5920, 2019 Nov 01.
Artículo en Inglés | MEDLINE | ID: mdl-31799054

RESUMEN

Pedicle screw placement accuracy during spinal fixation surgery varies greatly and severe misplacement has been reported in 1-6.5% of screws. Diffuse reflectance (DR) spectroscopy has previously been shown to reliably discriminate between tissues in the human body. We postulate that it could be used to discriminate between cancellous and cortical bone. Therefore, the purpose of this study is to validate DR spectroscopy as a warning system to detect impending pedicle screw breach in a cadaveric surgical setting using typical clinical breach scenarios. DR spectroscopy was incorporated at the tip of an integrated pedicle screw and screw driver used for tissue probing during pedicle screw insertions on six cadavers. Measurements were collected in the wavelength range of 400-1600 nm and each insertion was planned to result in a breach. Measurements were labelled as cancellous, cortical or representing a pre-cortical zone (PCZ) in between, based on information from cone beam computed tomographies at corresponding positions. In addition, DR spectroscopy data was recorded after breach. Four typical pedicle breach types were performed, and a total of 45 pedicle breaches were recorded. For each breach direction, the technology was able to detect the transition of the screw tip from the cancellous bone to the PCZ (P < 0.001), to cortical bone (P < 0.001), and to a subsequent breach (P < 0.001). Using support vector machine (SVM) classification, breach could reliably be detected with a sensitivity of 98.3 % [94.3-100 %] and a specificity of 97.7 % [91.0-100 %]. We conclude that DR spectroscopy reliably identifies the area of transition from cancellous to cortical bone in typical breach scenarios and can warn the surgeon of impending pedicle breach, thereby resulting in safer spinal fixation surgeries.

5.
Spine (Phila Pa 1976) ; 44(7): 517-525, 2019 04 01.
Artículo en Inglés | MEDLINE | ID: mdl-30234816

RESUMEN

STUDY DESIGN: Prospective observational study. OBJECTIVE: The aim of this study was to evaluate the accuracy of pedicle screw placement using augmented reality surgical navigation (ARSN) in a clinical trial. SUMMARY OF BACKGROUND DATA: Recent cadaveric studies have shown improved accuracy for pedicle screw placement in the thoracic spine using ARSN with intraoperative 3D imaging, without the need for periprocedural x-ray. In this clinical study, we used the same system to place pedicle screws in the thoracic and lumbosacral spine of 20 patients. METHODS: The study was performed in a hybrid operating room with an integrated ARSN system encompassing a surgical table, a motorized flat detector C-arm with intraoperative 2D/3D capabilities, integrated optical cameras for augmented reality navigation, and noninvasive patient motion tracking. Three independent reviewers assessed screw placement accuracy using the Gertzbein grading on 3D scans obtained before wound closure. In addition, the navigation time per screw placement was measured. RESULTS: One orthopedic spinal surgeon placed 253 lumbosacral and thoracic pedicle screws on 20 consenting patients scheduled for spinal fixation surgery. An overall accuracy of 94.1% of primarily thoracic pedicle screws was achieved. No screws were deemed severely misplaced (Gertzbein grade 3). Fifteen (5.9%) screws had 2 to 4 mm breach (Gertzbein grade 2), occurring in scoliosis patients only. Thirteen of those 15 screws were larger than the pedicle in which they were placed. Two medial breaches were observed and 13 were lateral. Thirteen of the grade 2 breaches were in the thoracic spine. The average screw placement time was 5.2 ±â€Š4.1 minutes. During the study, no device-related adverse event occurred. CONCLUSION: ARSN can be clinically used to place thoracic and lumbosacral pedicle screws with high accuracy and with acceptable navigation time. Consequently, the risk for revision surgery and complications could be minimized. LEVEL OF EVIDENCE: 3.


Asunto(s)
Realidad Aumentada , Tornillos Pediculares , Implantación de Prótesis/métodos , Cirugía Asistida por Computador/métodos , Adolescente , Adulto , Anciano , Femenino , Humanos , Imagenología Tridimensional/métodos , Vértebras Lumbares , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Sacro , Enfermedades de la Columna Vertebral/cirugía , Fusión Vertebral/métodos , Cirugía Asistida por Computador/instrumentación , Vértebras Torácicas , Tomografía Computarizada por Rayos X/métodos , Adulto Joven
6.
Spine (Phila Pa 1976) ; 43(14): 1018-1023, 2018 07 15.
Artículo en Inglés | MEDLINE | ID: mdl-29215500

RESUMEN

STUDY DESIGN: Cadaveric laboratory study. OBJECTIVE: To assess the feasibility and accuracy of minimally invasive thoracolumbar pedicle screw placement using augmented reality (AR) surgical navigation. SUMMARY OF BACKGROUND DATA: Minimally invasive spine (MIS) surgery has increasingly become the method of choice for a wide variety of spine pathologies. Navigation technology based on AR has been shown to be feasible, accurate, and safe in open procedures. AR technology may also be used for MIS surgery. METHODS: The AR surgical navigation was installed in a hybrid operating room (OR). The hybrid OR includes a surgical table, a motorized flat detector C-arm with intraoperative 2D/3D imaging capabilities, integrated optical cameras for AR navigation, and patient motion tracking using optical markers on the skin. Navigation and screw placement was without any x-ray guidance. Two neurosurgeons placed 66 Jamshidi needles (two cadavers) and 18 cannulated pedicle screws (one cadaver) in the thoracolumbar spine. Technical accuracy was evaluated by measuring the distance between the tip of the actual needle position and the corresponding planned path as well as the angles between the needle and the desired path. Time needed for navigation along the virtual planned path was measured. An independent reviewer assessed the postoperative scans for the pedicle screws' clinical accuracy. RESULTS: Navigation time per insertion was 90 ±â€Š53 seconds with an accuracy of 2.2 ±â€Š1.3 mm. Accuracy was not dependent on operator. There was no correlation between navigation time and accuracy. The mean error angle between the Jamshidi needles and planned paths was 0.9°â€Š±â€Š0.8°. No screw was misplaced outside the pedicle. Two screws breached 2 to 4 mm yielding an overall accuracy of 89% (16/18). CONCLUSION: MIS screw placement directed by AR with intraoperative 3D imaging in a hybrid OR is accurate and efficient, without any fluoroscopy or x-ray imaging during the procedure. LEVEL OF EVIDENCE: N/A.


Asunto(s)
Vértebras Lumbares/cirugía , Procedimientos Quirúrgicos Mínimamente Invasivos/normas , Neuronavegación/normas , Tornillos Pediculares/normas , Cirugía Asistida por Computador/normas , Vértebras Torácicas/cirugía , Cadáver , Estudios de Factibilidad , Humanos , Vértebras Lumbares/diagnóstico por imagen , Procedimientos Quirúrgicos Mínimamente Invasivos/métodos , Neuronavegación/métodos , Cirugía Asistida por Computador/métodos , Vértebras Torácicas/diagnóstico por imagen
7.
Spine (Phila Pa 1976) ; 41(21): E1303-E1311, 2016 Nov 01.
Artículo en Inglés | MEDLINE | ID: mdl-27513166

RESUMEN

STUDY DESIGN: A cadaveric laboratory study. OBJECTIVE: The aim of this study was to assess the feasibility and accuracy of thoracic pedicle screw placement using augmented reality surgical navigation (ARSN). SUMMARY OF BACKGROUND DATA: Recent advances in spinal navigation have shown improved accuracy in lumbosacral pedicle screw placement but limited benefits in the thoracic spine. 3D intraoperative imaging and instrument navigation may allow improved accuracy in pedicle screw placement, without the use of x-ray fluoroscopy, and thus opens the route to image-guided minimally invasive therapy in the thoracic spine. METHODS: ARSN encompasses a surgical table, a motorized flat detector C-arm with intraoperative 2D/3D capabilities, integrated optical cameras for augmented reality navigation, and noninvasive patient motion tracking. Two neurosurgeons placed 94 pedicle screws in the thoracic spine of four cadavers using ARSN on one side of the spine (47 screws) and free-hand technique on the contralateral side. X-ray fluoroscopy was not used for either technique. Four independent reviewers assessed the postoperative scans, using the Gertzbein grading. Morphometric measurements of the pedicles axial and sagittal widths and angles, as well as the vertebrae axial and sagittal rotations were performed to identify risk factors for breaches. RESULTS: ARSN was feasible and superior to free-hand technique with respect to overall accuracy (85% vs. 64%, P < 0.05), specifically significant increases of perfectly placed screws (51% vs. 30%, P < 0.05) and reductions in breaches beyond 4 mm (2% vs. 25%, P < 0.05). All morphometric dimensions, except for vertebral body axial rotation, were risk factors for larger breaches when performed with the free-hand method. CONCLUSION: ARSN without fluoroscopy was feasible and demonstrated higher accuracy than free-hand technique for thoracic pedicle screw placement. LEVEL OF EVIDENCE: N/A.


Asunto(s)
Imagenología Tridimensional/métodos , Vértebras Lumbares/cirugía , Procedimientos Ortopédicos/métodos , Cirugía Asistida por Computador/métodos , Vértebras Torácicas/cirugía , Estudios de Factibilidad , Humanos , Tornillos Pediculares
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...